1RU CPL Power System
PRODUCT OVERVIEW
Overview
The Compact Power Line platform is
designed to provide highly reliable
DC power for 48V distributed power
architectures. A single shelf conguration
provides up to 11kW of 48V output
power in 1U high and mounts in 19-inch
or 23-inch wide frames. The CPL product
platform is easily expandable for future
growth. CPL is a reliable DC power
solution for mission-critical enterprise and
telecommunications network equipment.
Shelf Options
The CP product line provides several shelf
options with common or split DC output
congurations. J85480S1 shelves have
four slots for rectiers or converters (PEMs).
CPL shelves are primarily used without a
controller or with a customer’s controller
using I2C communications. J2007001
shelves have four slots with space for a full-
feature Pulsar Edge Controller. The Pulsar
Edge controller has Ethernet connectivity
to facilitate remote network management
to monitor and control rectiers, batteries,
and distribution. CPL is ideal for a broad
range of applications requiring highly
efcient 48V DC power.
Rectier Options
CP2000 and CP2725 rectiers are single
phase, constant power rectiers that
provide 2000 Watts and 2725 Watts
(respectively) of highly reliable DC
power. The constant output power
characteristics, extended temperature
range, universal AC input, and compact
size are key attributes that make this
rectier the right choice for your
power needs.
Pulsar Edge Controller
CPL features the Pulsar Edge controller
delivering large system intelligence in
a small system form factor. Ethernet
connectivity with SNMP facilitates remote
network management.
Benets
Reliability
Proven eld performance
Advanced alarming
N+1 modularity
Intelligence
Industry leading controller features
Ethernet interface for remote access
Centralized network management
Investment Protection
Minimal space requirements
Versatile congurations
Efcient operation
On Time Delivery
Standard building blocks
4 - 6 week availability
24/7 support
Total Efciency
The Lineage Power Total Efciency™
(TE) architecture reduces energy loss
and lowers cooling costs by 50-70%.
TE products will prioritize sustainable
energy sources like solar, wind, water
and fuel cells over traditional utility grid
or diesel generator sources – and they
will intelligently respond to smart grid
information to reduce consumption
during peak demand periods. Active
Rectier Management (ARM) and
Battery Charging Optimization (BCO)
features increase efciency on current
and legacy power infrastructures. The
Total Efciency architecture addresses
issues end-to-end based on our proven
experience and expertise in batteries,
power distribution, DC energy systems,
AC/DC power supplies, and DC/DC
board mounted power to deliver a
solution that is more safe, reliable and
energy efcient than alternatives from
our competitors.
Compact 48V DC distributed
power system
Efciency approaching 97%
Maximum power in minimal space
Scalable to 80 kW
Powering enterprise and
telecommunications networks
Compact Power Line
48V DC Critical Power Solution
Compact Power Line Brochure © 2010 Lineage Power. All rights reserved.1/10
Page 2
CPL 2725 Total Efciency™ Rectier
Applications
Key Features
Specications
The CP2725 TE rectier provides signicantly improved operational efciency and is fully
backwards compatible with currently deployed CPL energy systems. This high-density
front-to-back airow rectier is designed for minimal space utilization and is highly
expandable for future growth.
The power module is available with many features including PoE isolation, RS485
communications bus for use with Lineage Power battery-plant controllers in forming an
energy reserve system and redundant I2C communications bus for use with a customer’s
controller. This exible and sophisticated feature set makes this front-end power supply an
excellent choice for power in a variety of application spaces.
Enterprise networks
Telecom equipment
Power over Ethernet
VoIP/soft switches
SAN/NAS/iSCSI applications
LAN/WAN/MAN applications
Indoor wireless
Routers and switches
Compact 1RU form factor
PMBus compliant dual
I2C and RS485 serial bus
communications
Front panel LED indicators
Internal variable-speed
fan control
Constant power; 52 58 Vdc
Programmable output
voltage; 44 – 58 Vdc
Universal AC input
PoE compliant
CE marked
RoHS 6 compliant
Hot pluggable
Input
Voltage Range
- Low-Line
- High-Line
90 - 140 Vac (1200W)
185 - 300 Vac (2725)
150 - 185 Vac (2725) derates to 80% full load
Input Frequency 47 – 63 Hz
Input Current 13.3 Arms @ 100Vac
11.2 Arms @ 120Vac
14.2 Arms @ 200Vac
13.1 Arms @ 240Vac
Inrush Transient 25 Apk typical
Input Leakage Current 2.5 mA typical
Total Harmonic Distortion (THD) < 5%
Power Factor 0.98 typical
Holdup Time 15 ms @ 75% full power
20 ms (loads below 1200W)
EMC Conducted FCC and CISPR22
(EN55022) Class A
General
Cooling Internal variable-speed fan cooled
Efciency Approaching 97%
Heat Dissipation 114 W / 387 BTU
Output
Voltage Default 54 Vdc
Voltage Adjust Range
- Hardware set via margin pin
- I2C or RS485 set
44 – 58 Vdc
42 – 58 Vdc
Output Current
- Low-Line
- High-Line
- High-Line
22.2 Adc, 54V
50.5 Adc, 54V
53.4 Adc, 52V
Output Power
- Low-Line
- High-Line
1200 Watts
2725 Watts
Psophometric Noise 2 mVrms max
Ripple (5Hz to 20MHz)
- RMS
- Peak-to-Peak
250 mVrms
500 mVpk-pk
Overvoltage Protection
- Delayed
- Immediate
60 Vdc
65 Vdc
Over Temperature
- Warning
- Shutdown
5°C
20°C
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
TECHNICAL SPECIFICATIONS – RECTIFIER
Page 3
Mechanical
Length (in./mm) 13.85 / 351.2
Width (in./mm) 4 / 101.6
Height (in./mm) 1.63 / 41.4
Weight (lb / kg) 5 / 2.27
Environmental
Operating Temperature -40ºC1 to +75ºC (-40 to 167 °F)
Storage Temperature -40°C to +85°C (-40 to 185 °F)
Power De-Rating > +55°C (derates @ 2% per ° C)
Relative Humidity 95% max, non-condensing
Altitude 4,000m max (13,000 ft)
Audible Noise 55dBA, typical
Safety and Standards Compliance
Zone 4 Per Telcordia GR-63-CORE, all oors when installed
in CPL shelf
Safety CE mark to Low Voltage Directive 2006/95/EC
UL 609501-1 Recognized
CAN/CSA C22.2 No. 60950-1-03 Certied
VDE 0805-1 Licensed to IEC60950-1
RoHS Compliant to RoHS EU Directive 2002/95/EC
EMC FCC and CISPR22 (EN 55022) Class A
ESD EN/IEC 61000-4-2 Level 3
1. Designed to start at an ambient as low as -4C but may not meet
operational limits until above -5°C.
Outline Drawing
Symbol Analog Mode I2C Mode RS485 Mode
On: Input OK
Blinking: Input out of limits
On: Output OK
Blinking: Overload
On: Over-temperature warning On: Over-temperature warning
Blinking: Service
On: Over-temperature warning
On: Fault On: Output OK
Blinking: Overload
Dimensions
Front Panel LEDs
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
TECHNICAL SPECIFICATIONS – RECTIFIER
Page 4
CPL 2000 Rectiers
Applications
Key Features
Specications
The CPL 2000 rectiers are specically designed to operate as an integral part of a
complete distributed power system. The high-density, front-to-back airow rectier is
designed for minimal space utilization and is highly expandable for future growth.
The power modules are available with many features including PoE isolation, RS485
communications bus for use with Lineage Power battery plant controllers in forming an
energy reserve system and redundant I2C communications bus for use with a customer’s
controller. This exible and sophisticated feature set makes this front-end power supply an
excellent choice for power in a variety of application spaces.
Enterprise networks
Telecom equipment
Power over Ethernet
VoIP/soft switches
SAN/NAS/iSCSI applications
LAN/WAN/MAN applications
Indoor wireless
Routers and switches
Compact 1RU form factor
PMBus compliant dual
I2C and RS485 serial bus
communications
Front panel LED indicators
Internal variable-speed
fan control
Constant power; 52 58 Vdc
Programmable output
voltage; 44 – 58 Vdc
Universal AC input
PoE compliant
CE marked
RoHS 6 compliant
Hot pluggable
Input
Voltage Range
- Low-Line
- High-Line
85 – 175 Vac (1200W)
176 – 275 Vac (2000W)
Input Frequency 47 – 63 Hz
Input Current 13.3 Arms @ 100Vac
11.2 Arms @ 120Vac
11.8 Arms @ 200Vac
13.1 Arms @ 240Vac
Inrush Transient 25 Apk typical
Input Leakage Current – CP2000 1.5 mA
Total Harmonic Distortion (THD) < 5%
Power Factor 0.98 typical
Holdup Time 15 ms @ 75% full power
20 ms (loads below 1200W)
EMC Conducted FCC and CISPR22
(EN55022) Class A
Output
Voltage Default 54 Vdc
Voltage Adjust Range
- Hardware set via margin pin
- I2C or RS485 set
44 – 58 Vdc
42 – 58 Vdc
Rated Output Current – CP2000
- Low-Line
- High-Line
22.2 Adc, 54V
37 Adc, 54V
Rated Output Power CP2000
- Low-Line
- High-Line
1200 Watts
2000 Watts
Psophometric Noise 2 mVrms max
Ripple (5Hz to 20MHz)
- RMS
- Peak-to-Peak
250 mVrms
500 mVpk-pk
Overvoltage Protection
- Delayed
- Immediate
60 Vdc
65 Vdc
Over Temperature
- Warning
- Shutdown
5°C
20°C
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
TECHNICAL SPECIFICATIONS – RECTIFIER
Page 5
Mechanical
Length (in./mm) 13.85 / 351.2
Width (in./mm) 4 / 101.6
Height (in./mm) 1.63 / 41.4
Weight (lb / kg) 5 / 2.27
General
Cooling Internal variable-speed fan cooled
Efciency 90% @ 100 Vac (Vout >52V, Pout >50%
93% @ 230 Vac (Vout >52V, Pout
Heat Dissipation 151W / 514 BTU
Environmental
Operating Temperature -40ºC1 to +75ºC (-40 to 167 °F)
Storage Temperature -40°C to +85°C (-40 to 185 °F)
Power De-Rating > +55°C (derates @ 2% per ° C)
Relative Humidity 95% max, non-condensing
Altitude 4,000m max (13,000 ft)
Audible Noise 55dBA, typical
Safety and Standards Compliance
Zone 4 Per Telcordia GR-63-CORE, all oors when installed
in CPL shelf
Safety CE mark to Low Voltage Directive 2006/95/EC
UL 609501-1 Recognized
CAN/CSA C22.2 No. 60950-1-03 Certied
VDE 0805-1 Licensed to IEC60950-1
RoHS Compliant to RoHS EU Directive 2002/95/EC
EMC FCC and CISPR22 (EN 55022) Class A
ESD EN/IEC 61000-4-2 Level 3
1. Designed to start at an ambient as low as -4C but may not meet
operational limits until above -5°C.
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
Outline Drawing
Symbol Analog Mode I2C Mode RS485 Mode
On: Output OK
Blinking: Overload
On: Output OK
Blinking: Overload
On: Over-temperature warning On: Over-temperature warning
Blinking: Service
On: Over-temperature warning
On: Fault On: Output OK
Blinking: Overload
TECHNICAL SPECIFICATIONS – RECTIFIER
Dimensions
Front Panel LEDs
Page 6
CPL DC/DC Converter
The CPL DC to DC converter is specically
designed to convert a wide range 48V
input voltage to a regulated 48V output
voltage. The high-density, front-to-back
airow power entry module (PEM) is
designed for minimal space utilization and
is highly expandable for future growth.
The DC/DC converter is available with
many features including PoE isolation
and dual-redundant I2C communications
bus for use with a customer’s controller.
Thisexible and sophisticated feature set
makes this DC PEM an excellent choice
for power in a variety of application
spaces requiring modular DC-to-DC bulk
intermediate voltages.
Applications
Key Features
Enterprise networks
Telecom equipment
Power over Ethernet
VoIP/soft switches
SAN/NAS/iSCSI applications
LAN/WAN/MAN applications
Indoor wireless
Routers and switches
Compact 1RU form factor
PMBus compliant dual I2C
serial bus communications
Front panel LED indicators
Internal variable-speed
fan control
Input current < 60A @
40Vdc input
Programmable output
voltage; 44 – 58 Vdc
CE marked
RoHS 5 compliant
Hot pluggable
Input
Operating Voltage -40 to -72 Vdc
Input Current 60 Adc @ input voltage >40Vdc
Cold Start Inrush Current 60 Adc
Low Input Shutdown of Main
Output
-39 Vdc typical
Input Turn-On of Both Outputs -43.5 Vdc typical
Reverse Input Voltage Module not damaged
Idling Power
- Output OFF
- Output ON
35W (5Vdc output @ no load)
60W (Both outputs @ no load)
Holdup Time 8 ms (min Vin = 48Vdc, output @ ½
full load)
Ride Through 8 ms (min Vin = 48Vdc, output @ ½
full load)
Input Capacitance 25 µF max
Output
Maximum Output Power 2000 Watts
Output Voltage Setpoint 54 Vdc
Output Voltage Range 44 – 58 Vdc
Output Current 37A max @ 54Vdc
Active Current Share -5 – 5% FL (single wire connection)
Passive Current Share -15 – +15% FL (without single wire
connection)
Ripple (5Hz to 20MHz)
- RMS
- Peak-to-Peak
250 mVrms
500 mVpk-pk
External Bulk Load Capacitance 5000 µF max
Turn-On
- Delay
- Rise Time
- Overshoot
5 s typical
500 ms typical
5% max
Restart Shutdown Delay 20 s typical
Overload
- Current Limit
- Shutdown
38.9 – 43 Adc
39 Adc max
Overvoltage
- Delayed
- Instantaneous
60 Vdc
65 Vdc
Over Temperature
- Warning
- Shutdown
5°C typical
20°C minimum
General
Cooling Internal variable-speed fan cooled
Efciency 90% typical, 75 – 100% of full load
84% typical, loads > 25% of full load
Heat Dissipation 222W / 758 BTU
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
TECHNICAL SPECIFICATIONS – DC/DC CONVERTER
Page 7
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
Mechanical
Length (in./mm) 13.85 / 351.2
Width (in./mm) 4 / 101.6
Height (in./mm) 1.63 / 41.42
Weight (lb / kg) 4.6 / 2.1
Environmental
Operating Temperature -40°C1 to +75°C (-40 to 167 °F)
Storage Temperature -40°C to +85°C (-40 to 185 °F)
Power Derating > +55°C (derates @ 1% per ° C)
Relative Humidity 95% max, non-condensing
Altitude 4,000m max (13,000 ft)
Audible Noise 55dBA, typical
Safety and Standards Compliance
Zone 4 Per Telcordia GR-63-CORE, all oors when installed
in CPL shelf
Safety CE mark to Low Voltage Directive 2006/95/EC
UL 60950¬1-1 Recognized
CAN/CSA C22.2 No. 60950-¬1
VDE 0805-1 Licensed to IEC60950-1
RoHS Compliant to RoHS EU Directive 2002/95/EC
EMC FCC and CISPR22 (EN 55022) Class A
ESD EN/IEC 61000-4-2
1. Designed to start at an ambient as low as -4C but may not meet
operational limits until above -5°C.
Outline Drawing
Symbol Analog Mode I2C Mode RS485 Mode
On: Input OK
Blinking: Input out of limits
On: Input OK
Blinking: Input out of limits
On: Over-temperature warning On: Over-temperature warning
Blinking: Service
On: Fault
Dimensions
Front Panel LEDs
TECHNICAL SPECIFICATIONS – DC/DC CONVERTER
Page 8
Applications
Key Features
Enterprise Networks - Voice, Data, PoE
Telecommunications networks
Transmission equipment
Fiber in the loop
Routers/switches
Data networks
PBX
Remote Access and Features
Integrated 10/100Base-T Ethernet
Network
- TCP/IP
- SNMP V2c for management
- SMTP for email
- Telnet for command line interface
- DHCP for plug-n-play
- FTP for rapid backup and upgrades
- HTTP for standard web pages and
browsers
- Compatible with Galaxy Manager
and other management packages
- Shielded RJ-45 interface referenced
to chassis ground
Password protected security levels: User,
Super-User, Administrator for all access
Ground-referenced RS232 system port
ANSI T1.317 command-line interface
Modem access support
- Remote via external modem
- Callback security
EasyView2, Windows-based GUI
software for local terminal or
Modem access
Standard System Features
Monitor and control of more than 40
connected devices
- Maximum of 32 rectiers
- Maximum of 6 distribution control cards
- Robust RS485 system bus
Standard and user dened system alarms
- Alarm test
- Assignable alarm severity: Critical,
Major, Minor, Warning, and
Record-only
Rectier management features
- Automatic rectier restart
- Active Rectier Management
(energy efciency)
- Remote rectier (on/off)
- Reserve Operation
- Automatic rectier sequence control
- N + X redundancy check
Multiple Low Voltage Load and Low
Voltage Battery Disconnect thresholds (4)
Conguration, statistics, and history
- All stored in non-volatile memory
- Remote/local backup and restore of
conguration data
Industry standard defaults
- Customer specic congurations
available
Remote/ local software upgrade
Basic, busy hour, and trend statistics
Detailed event history
User dened events and derived channels
Standard Battery Management Features
Float/boost mode control
- Manual boost
- Manual timed boost locally, T1.317,
and remotely initiated
- Auto boost terminated by time
or current
Battery discharge testing
- Manual (local/remote)
- Periodic
- Plant Battery Test (PBT) input driven
- Congurable threshold or
20% algorithm
- Graphical discharge data
- Rectiers on-line during test
Slope thermal compensation
- High temperature
- Low temperature
- Step temperature
- STC Enable/Disable, low temperature
Enable/Disable
- Congurable mV/°C slopes
State of charge indication
High temperature disconnect setting
Reserve-time prediction
Recharge current limit
Emergency Power-Off input
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
Pulsar Edge Controller
The CPL Pulsar Edge controller delivers large system intelligence in a small system form factor. This
family of controllers functions asa network interface controller (NIC) and as a full-featured battery
plant controller to the Compact Power Line (CPL) platform. Its thin modular plug-in form factor
minimizes shelf space consumption allowing maximum power module and distribution capabilities yet
provides nearly all the features found in controllers used in much larger power systems.
The Pulsar Edge CP841A controller is utilized in bulk power applications in data centers and enterprise
applications. Ethernet connectivity with SNMP facilitates remote network management access
through its front-accessible RS232 or USB port and is aided by the EasyView2 graphical user interface.
As a battery plant controller, it provides a complete set of features to monitor and control rectiers,
batteries, and distribution. Aexible set of congurable inputs allow the CP841A to monitor a wide variety of system equipment and
incorporate appropriate state information enabling a centralized point of management.
The controller utilizes standard network management protocols allowing for advanced network supervision. Lineage Power Galaxy
Manager™ software is the centralized visibility and control component of a comprehensive power management system designed to
meet engineering, operations, and maintenance needs. The Galaxy Manager client-server architecture enables remote access to
system controllers across the power network.
TECHNICAL SPECIFICATIONS - CONTROLLER
Page 9
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
TECHNICAL SPECIFICATIONS - CONTROLLER
General
Operating Voltage ±24 Vdc, ±48 Vdc
(Range: ±18 to ±60 Vdc)
Input Power Less than 7W
Operating Temperature Range -40°C to +75 °C (-40 to 167 °F)
Storage Temperature Range -40°C to +85°C (-40 to 185 °F)
Operating Relative Humidity 0 - 95% (non-condensing)
Physical Specications 1.75 in. H, 0.75 in. W, 8.00 in. D; 0.5lb
45mm H, 20mm W, 204mm D; 227g
Display 8-line by 40-character backlit LCD
Agency Certications
Radiated Emissions FCC, Class B; EN 55022, Class B
Safety UL Unlisted Component as Part of CPL or SPS
Power System
RoHS Compliant to RoHS EU Directive 2002/95/EC
EMC FCC/EN55022 Class B, CISPR22 Level B
ESD EN 61000-4-2 level 4
Integrated Monitoring Inputs/Outputs
System plant voltage (accuracy ±0.5%, resolution 0.01V)
One system shunt (accuracy ±1% full scale, resolution 1A)
- Battery or load
- Mounted in the return side of DC bus
Up to 15 binary inputs
- Six inputs close/open to battery
- 9 input close/open to return (number is dependent upon
number of output alarms)
- User assignable
Up to 5 user assignable Form-C output alarms (50VDC @ .3A)
1-Wire™ bus devices
- Up to 16 temperature probes (QS873)
- Up to 6 mid-string monitors (ES771)
Galaxy Manager Compatible
Centralized web server and database with multiple user access
to live or managed data with drill down to problem details
Monitor and control of more than 40 connected devices
Management information from polling or alarms received from
alarm traps from multiple sites are available on one screen via
the inter/intranet
Trend user selected data over time
Automatic or manual report generation
Standard engineering tools like reserve time calculators and
cable voltage drop analyzer
Page 10
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
Notes:
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
Page 11
48V DC Critical Power Solution
Features Model J85480S1
Features Model J2007001
The Compact Power Line platform is designed to provide highly
reliable DC power for 48V distributed power architectures. A
single shelf conguration provides up to 11kW of 48V output
power in 1U high and mounts in 19-inch or 23-inch wide frames.
The CPL product platform is easily expandable for future growth.
CPL is a reliable DC power solution for mission-critical enterprise
and telecommunications network equipment.
The CPL product line provides several shelf options. J85480S1
shelves have four slots for either rectiers or converters (PEMs).
These shelves are primarily used without a controller or with
a customer’s controller using I2C communications. J2007001
shelves have four slots with space for a full-feature Pulsar Edge
Network Interface Controller (NIC). The Pulsar Edge controller
has Ethernet connectivity with SNMP to facilitate remote network
management to monitor and control rectiers, batteries, and
distribution. These shelves are used with either shelf mounted
distribution or external distribution panels for small battery plant
applications.
Fits into a standard 19” rack
Two DC Outputs may be common or split. Each output bus is
rated for 100A with two-hole lug landings for 2 AWG wire.
Choose between IEC-320 C13 or C19 AC input connections.
Analog or dual/redundant I2C communications.
Adjustable mounting ears for either ush front or multiple set
back positions.
Fits into a standard 19” rack
Single DC output rated for 200A with two-hole lug landings for
up to 2/0 AWG cable.
Choose between IEC-320 or Molex Mini-Fit SR for AC input.
Single, dual or quad input feeds
RS485 communications.
Adjustable mounting ears with multiple set back positions.
Up to 3 shelves may be interconnected with bus straps for DC
outputs for a 600A system
Plug-N-Play CP841A controller with front access craft port, rear
access LAN and alarm connections
Select Shelves include distribution modules
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
ORDERING INFORMATION – COMPACT POWER LINE
Ordering Information Compact Power Line
Page 12
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
ORDERING INFORMATION – COMPACT POWER LINE
Shelf Line Drawing – J85480S1Shelves
List Max Rectifer
Size AC Input DC Output Rear View of Shelf
20 2725 Watts IEC-320,
C19 Cords
Common Bus
(Lugs)
21 2725 Watts Split Bus (Lugs)
23 2000 Watts IEC-320,
C13 Cords
Common Bus
(Lugs)
27 2000 Watts Split Bus (Lugs)
14 CC109124764 None
DC Input
Split Bus (Lugs)
Converter (PEM) Shelf
J85480S1 Shelf Options
1. CP2725 rectiers not recommended for use with shelves having
C13 AC inputs.
2. J85480S1 shelves communication protocol - Analog (no controller), I2C
(customer supplied controller).
3. List 23 shelf is POE compliant.
4. Split bus shelves cannot be paralleled. Two common bus shelves may be
connected together.
5. Other J85480S1 shelves are stackable up to 8 shelves to accommodate 32
paralleled power supplies. Contact your Lineage Power Sales Representative
for additional information.
6. In controller-less applications, shelves are xed output to ±54Vdc. Contact
your Lineage Power Sales Representative for shelf congurations with ±48Vdc
xed output.
7. Other J85480S1 shelf congurations are available for use with Lineage
Pulsar Plus controllers. Contact your Lineage Power Sales Representative for
additional information.
Notes:
Page 13
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
ORDERING INFORMATION – COMPACT POWER LINE
Description Schematic
Common Output Bus for Terminal Lug Connection
Each Lug Connection rated for 100A with 2 gage
wire (200A for shelf)
Split Output Bus for Terminal Lug Connection
Vdc( - ) has Split buses Vdc( + ) is common to
both sections.
• Each bus may be independently controlled
• Multiple shelves may not be paralleled together.
Each Lug Connection rated for 100A with 2 gage
wire (200A for shelf)
J1 CONNECTOR – Pin Out
Pin Signal Pin Signal
1 POWER_CAP_1 16 SDA_1
2 POWER_CAP_2 17 Fault
3 POWER_CAP_3 18 Alert#_0
4 POWER_CAP_4 19 Enable side B
5 MOD_PRES_1 20 Logic_GRD
6 MOD_PRES_2 21 Enable Side A
7 MOD_PRES_3 22 Logic_GRD
8 MOD_PRES_4 23 Alert#_1
9 PFW_1 24 5VA
10 PFW_2 25 OTW
11 PFW_3 26 Reset
12 PFW_4 27 Iso. barrier n/c
13 SCL_0 28 Iso. barrier n/c
14 SCL_1 29 Shelf_Addr_B
15 SDA_0 30 Shelf_Addr_A
J2 CONNECTOR – Pin Out
Pin Signal Pin Signal
1 SCL_0 8 Alert#_1
2 SCL_1 9 Isolation n/c
3 SDA_0 10 Isolation n/c
4 SDA_1 11 Ishare - B
5 Alert#_0 12 Ishare - A
6 5VA 13 8V_INT - B
7 Logic_GRD 14 8V_INT - A
DC Output Types – J85480S1 Shelves
Communication Signals – J85480S1 Shelves
Page 14
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
ORDERING INFORMATION – COMPACT POWER LINE
Shelf Line Drawing – J2007001 Shelves
List Max
Rectifer Size AC Input DC Output Rear View of Shelf
3 2725 Watts Single AC feed
(terminal blocks
for 6ga wire
and ¾” conduit
tting)
DC output bus
is rated for 200A
for two 2ga or
one 2/0 gage
two-hole lugs
(¼-20 studs on
5/8” centers).
DC Output Bus AC Signal
4 2725 Watts Individual feed
(Molex Mini-Fit SR)
5 2725 Watts Dual feed (Molex
Mini-Fit SR)
6 2725 Watts Individual feed
(IEC-320 C19
Cords)
7 2725 Watts Single AC feed
(terminal blocks
for 6ga wire
and ¾” conduit
tting)
2 battery input -
terminal blocks
for 8ga wire, 30A
breakers, LVBD.
Ten load output
– terminal blocks
for 12ga wire, 10
GMT fuses rated
10A each
Bat In DC Out AC Signal
7A 2725 Watts Individual feed
(IEC-320 C19
cords)
J2007001 Shelf Options
1. CP841A Pulsar Edge Controller ships separately.
2. Up to 3 shelves may be interconnected. Up to 8 shelves may be interconnected using the controller’s rectier ID override function.
Notes:
Page 15
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
ORDERING INFORMATION – COMPACT POWER LINE
J2007001 Shelves System Controller
Communication Signals for J2007001 Shelves
Battery Monitoring
J1 CONNECTOR – Pin Out
Pin Signals for SPS841A_3C3R Signals for SPS841A_0I5R
1 ALM1 Input Alarm Relay 3 Rtn
2 ALM2 Input Alarm Relay 2 Rtn
3 Alarm Relay 1 Rtn Alarm Relay 1 Rtn
4 Power Minor Rtn Power Minor Rtn
5 Power Major Rtn Power Major Rtn
6 ALM1, 2, 6C RTNS Alarm Relay 3
7 ALM6 Input Alarm Relay 2
8 Alarm Relay 1 Alarm Relay 1
9 Power Minor Power Minor
10 Power Major Power Major
Several versions of the CP841A Pulsar Edge controller are available. Each offers different alarm input/outputs on the
J1 connector of the shelf.
CP841A_9C0R J1 has 9 alarm inputs with a common return and no output relays
CP841A_3C3R J1 has 3 alarm inputs with a common return and 3 output relays; Power Major, Power Minor, 1 Selectable
CP841A_0I5R J1 has 0 alarm inputs and 5 output relays; Power Major, Power Minor, 3 Selectable
J2 CONNECTOR
Pin Signal
1 ALM6 Input
2 -
3 ALM3 Input
4 ALM4 Input
5 ALM5 Input
6 -48V
7 -48V
8 -48V
J7 CONNECTOR
Pin Signal
1 FAJ
2 Coil Rtn
3 LVD_NC
4 LVD_NO
5 Shunt-
6 OS
7 Coil1
8 Coil2
9 LVD Status Rtn
10 Shunt+
J1 provides alarm outputs and inputs based on the controller installed (see
table below). Inputs are “Dry”, no voltage, contact Closures or Opens to
a common return on pin 6. Outputs are relay contacts. Both input and
output alarms are customer dened on the controller’s web pages.
J2 provides alarm inputs (see table below). Alarm inputs are contact
Closures or Opens to the non-grounded side of the dc bus [-48V]. Pins 6, 7,
8 provide -48V for these alarm inputs.
J3 battery thermal probe (QS873A) or battery mid-string voltage monitor
(ES771) with battery thermal probe.
J4 shelf to shelf communication connection
J5 LAN/Ethernet.
J7 provides distribution control for shelves with external distribution. See
table below.
Temperature/Voltage probes are needed for battery monitoring. They
are connected to each battery or battery string to provide slope thermal
compensation, temperature alarms and voltage imbalance alarms. Refer to
ordering guide for diagram and part numbers.
Page 16
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
ORDERING INFORMATION – COMPACT POWER LINE
AC DC
J85480S1 Rectier Shelf
Ordering Guide
J85480S1 Converter Shelf
Ordering Guide
Communication Cables
10 Communication Cable (J1) CC848854034
Shelf to shelf communication
cable (J2)
CC848848952
Rectier
CP2000AC54PE CC109120722
CP2725AC54Z CC109142873
CP2725AC54HEZ CC109149423
Rectier Slot Filler
Central Ofce White CC848822263
Raven Black CC848781534
Graphite CC848825233
Converter (PEM) Options
CP2000DC54PE CC109146692
Rectier Slot Filler
Central Ofce White CC848822263
Raven Black CC848781534
Graphite CC848825233
Rectier Shelf Options
List 20 CC109147344
List 21 CC109147328
List 23 CC109150447
List 27 CC109155743
Converter Shelf Options
List 14 CC109124764
Mounting Brackets
1U bracket for 23”
frame mount
CC848844803
2U bracket for 23”
frame mount
848683009
Wall mount bracket CC848864504
Mounting Brackets
1U bracket for 23”
frame mount
CC848844803
Wall mount bracket CC848864504
DC Input Cables
DC input cable,
10gage, 4’
CC848794908
DC Output Cables
DC output cable,
2gage 10
848748987
DC Bus for
1/4” Faston
Connections
(2 required)
CC848886192
AC Input, DC Output Cables
C13 plug with 5-15P plug, 10’ CC848776105
C13 plug with L6-20P plug, 10’ CC848820317
C13 plug, unterminated, 10’ 847861192
C19 plug, with 5-15P plug, 8’ CC848850792
C19 plug, with L6-20P plug, 8’ CC848850842
C19 plug, unterminated, 8 CC848847368
DC output cable, 2gage, 10 848748987
DC Bus for 1/4” Faston Connections
(2 required)
CC848886192
Page 17
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
ORDERING INFORMATION – COMPACT POWER LINE
Battery Management Accessories
A: QS873A Thermal Probe CC109142980
B: 10’ probe to controller wireset CC848817024
C: 1’ probe to probe wireset CC848822560
C: 5’ probe to probe wireset 848719803
C: 10’ probe to probe wireset CC848822321
ES771A Voltage Monitor Card 108958422
D: 2 ½ ‘ ES771A to probe wireset CC848791517
D: 6’ ES771A to probe wireset CC848797290
D: 10’ ES771A to probe wireset 848719829
G: 4’ ES771A to ES771A or controller wireset CC848791500
G: 10’ ES771A to ES771A or controller wireset 848652947
AC DC
J2007001 Shelf
Ordering Guide
+
-+
To Controller
To Next ES771
--+ + -
48V battery string #1
+-
+- -+ + -
48V battery string #2
+-
+
--+ + -
48V battery string #3
ES771
Voltage Module
108958422
CC
G
G
D
USE COUPLER 555052-1 TO DAISY CHAIN
G-STYLE CABLES UP TO 150 FEET
VOLTAGE SENSE WIRE
+
-+
USE COUPLER 555052-1 AND G-STYLE CABLE TO
DAISY CHAIN B-STYLE CABLE UP TO 150 FEET
TO CONTROLLER
--+ + -
48V battery string #1
+-
+- -+ + -
48V battery string #2
+-
+
--+ + -
48V battery string #3
C CCB
TRIM BROWN VOLTAGE SENSE
WIRE ON B AND C-STYLE CABLES
MAX 16
PROBES
Alarm and Communication Cables
15 Alarm or distribution cable (J1 or J7) CC848865980
50 Alarm or distribution cable (J1 or J7) CC848817651
150Alarm or distribution cable (J1 or J7) CC848817668
15’ Alarm input cable (J2) CC848853614
Shelf to shelf communication cable
(J3, J4)
CC848847780
Rectier Shelf Options
List 3 CC109147542
List 4 CC109140043
List 5 CC109140051
List 6 (Shown) CC109140027
Rectier Shelves with distribution
List 7 Rectier/Distribution CC109151775
List 7A Rectier/Distribution CC109151841
Rectier
CP2000AC54PE CC109120722
CP2725AC54Z CC109142873
CP2725AC54HEZ CC109149423
Rectier Slot Filler
Central Ofce White CC848822263
Raven Black CC848781534
Graphite CC848825233
Controller
CP841A_9C0R CC109140068
CP841A_3C3R CC109145331
CP841A_0I5R CC109145356
Slot Filler CC848847871
Mounting Brackets
1U bracket for 23”
frame mount
CC848844803
2U bracket for 23”
frame mount
848683009
Wall mount bracket CC848864504
AC Input, DC Output Cables
C19 plug, with 5-15P plug, 8’ CC848850792
C19 plug, with L6-20P plug, 8’ CC848850842
C19 plug, unterminated, 8 CC848847368
Molex Mini-Fit SR, unterminated,
8awg, 10’ (2 cables provided)
848710711
DC output cable, 2ga, 10’ 848748987
DC Bus Bar Strap (2 required) CC848844324
Page 18
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
Power Module Output Power/Input Voltage Output Voltage Protection Physical
CP2000AC54PE 2000W / 200-240VAC
1200W / 100-120VAC
Hardware set
44 - 58Vdc
Software set
42 – 58Vdc
15A breaker, 14 gauge wire
Length: 13.85”/351.8mm
Width: 4.00”/101.6mm
Height: 1.66”/42.2mm
Weight: 4.6lb/2.1kg
CP2725AC54Z 2725W / 200-240VAC
1200W / 100-120VAC
20A breaker, 12 gauge wire
CP2725AC54TEZ 2725W / 200-240VAC
1200W / 100-120VAC
20A breaker, 12 gauge wire
CP2000DC54-PE 2000W / 40-72VDC 60A breaker, 8 gauge wire
20A breaker, 12 gauge wire
Mechanical J85480S-1 J2007001
Height 1.71inches/43.4mm 1.71 inches/43.4mm
Width (with mounting ears) 19 inches/483mm 19 inches/483mm
Depth 16.25 inches/413mm 17.06 inches/433mm
Weight (without rectiers) 9.25lbs/4.2kg 8.75lbs/4.0kg
Environmental J85480S-1 J2007001
Operating Temperature Range List 14: -40°C to 75°C (-40 to 167 °F)
Lists 20, 21:
-40°C to 25°C (-40 to 77 °F)
[Commercial 60°C C19 AC cord]
-40°C to 55°C (-40 to 131 °F)
[High Temp C19 AC cord]*
Lists 23, 27:
-40°C to 25°C (-40 to 77 °F)
[Commercial 60°C C13 AC cord]
-40°C to 55°C (-40 to 131 °F)
[High Temp C13 AC cord]*
Lists 6, 7A:
-40°C to 25°C (-40 to 77 °F)
[Commercial 60°C C19 AC cord]
-40°C to 55°C (-40 to 131 °F)
[High Temp C19 AC cord]*
Lists 3, 4, 5, 7: -40°C to 55°C (-40 to 131 °F)
Operating Relative Humidity 0 - 95% (non-condensing)
Storage Temperature Range -40°C to 85°C (-40 to 185 °F)
EMC FCC, EN 55022, CISPR22, Level A, conducted and radiated
Immunity EN55024 (CISPR24) Class A, conducted and radiated
Safety/Standards Compliance J85480S-1 J2007001
Safety Standards CAN/CSA C22.2 No. 60950-1-03, UL 60950-1, 1st Edition
VDE IEC 60950-1, 1st Edition
Certication Marks Lists 14, 20, 21, 23 VDE
Lists 14 UL Recognized (Canada and U.S.)
Lists 20, 21, 23 UL Listed (Canada and U.S.)
Lists 4, 5, 6 VDE
Lists 4, 5 UL Recognized (Canada and U.S.)
Lists 6 UL Listed (Canada and U.S.)
Specications
Rectiers
Shelves
NOTES: PE sufx denotes PoE compliance. TE sufx denotes total efciency. All CP Rectiers are RoHS 6 compliant.
* All Lineage CP AC cords are High Temperature cords.
ORDERING INFORMATION – COMPACT POWER LINE
Page 19
© 2010 Lineage Power. All rights reserved.1/10 Compact Power Line Brochure
Notes:
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
.........................................................................................................................................................................................................................
© 2010 Lineage Power. All rights reserved.
Lineage Power reserves the right to change specications without notice. Please contact your Lineage
representative to conrm current specications. Please visit www.lineagepower.com/patents for patents and
trademark information.
1/10 Compact Power Line Brochure
Contact Us
For more information, call Lineage Power toll free at 877-LINEAGE (877-546-3243),
or +1 972 244 9288 and visit us on the Web at lineagepower.com
Management Visibility
Galaxy Managersoftware is the centralized visibility and control
component of a comprehensive power management system
designed to meet engineering, operations and maintenance
needs. The Galaxy Manager client-server architecture enables
remote access to system controllers across the power network.
Dashboard display with one-click access to management
information database
Trend analysis
Scheduled or on demand reports
Fault, conguration, asset, and performance management
Training
Lineage Power offers on-site and classroom training options
based on certication curriculum. Technical training can be
tailored to individual customer needs. Training enables customers
and partners to more effectively manage and support the power
infrastructure. We have built our training program on practical
learning objectives that are relevant to specic technologies or
infrastructure design objectives.
Service & Support
Lineage Power eld service and support personnel are trusted
advisors to our customers always available to answer
questions and help with any project, large or small. Our certied
professional services team consists of experts in every aspect of
power conversion with the resources and experience to handle
large turnkey projects along with custom approaches to complex
challenges. Proven systems engineering and installation best
practices are designed to safely deliver results that exceed our
customers’ expectations.
Warranty
Lineage Power is committed to providing quality products and
solutions. We have developed a comprehensive warranty that
protects you and provides a simple way to get your products
repaired or replaced as soon as possible.
CPL comes with a two year hardware warranty.
For full warranty terms and conditions please go to
www.lineagepower.com/warranty.
ORDERING INFORMATION – COMPACT POWER LINE