ACDC
Specification
40100 Watts
•Compact Size
•IT & Medical Approvals
•Convectioncooled
•Class I and II Construction
•DC Input Version Available (DCM Series)
•PoE Isolation Version Available (POE Series)
•3 Year Warranty
ECM Series
Input
Input Voltage • 90-264 VAC (120-370 VDC)
Input Frequency • 47-63 Hz; 440 Hz*
Input Current • 40 W: 0.4 A max at 230 VAC
60 W: 0.6 A max at 230 VAC
100 W: 0.9 A max at 230 VAC
Inrush Current • 40 A max at 230 VAC
Earth Leakage Current • <125 µA at 115 VAC/60 Hz
<210 µA at 230 VAC/50 Hz
Power Factor • EN61000-3-2
Input Protection • Internal T3.15 A, 250 V fuse in line
and neutral
Output
Output Voltage • See tables
Output Voltage Trim • ±5% on 3.3 V & 5 V versions, ±10% on
other single output models and V1 of
multi-output models. (See note 1 for
ECM40/60 models)
Initial Set Accuracy • ±1.0% V1, ±5% V2, V3 & V4
Minimum Load • See tables
Start Up Delay • 1.5 s max
Start Up Rise Time • 10 ms max
Hold Up Time • 16/75 ms min at 115/230 VAC
Line Regulation • ±0.5%
Load Regulation • ±1% single output models;
±3% V1, ±5% V2 & V3 ECM40/60
multi-output models.
±1% V1 & V2, ±5% V3 & V4 ECM100
Cross Regulation • 2% on ECM40/60 only
Over/Undershoot • None at turn on/off
Transient Response • 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise • 1% pk-pk, 20 MHz bandwidth
Overvoltage Protection • 115-135% Vnom, recycle input to reset
Overload Protection • 110-150% on primary power limit,
auto recovery
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature • 0.05%/°C
Coefficient
Peak Load • 120% for 100 ms ECM40/60 (see note 3)
* Safety approvals cover frequency range 47-63 Hz
xppower.com
General
Efficiency • 80-85% depending on model
Isolation • 4000 VAC Input to Output 2 x MOPP
ECM100 single output models, 1 x MOPP
ECM100 multi output and all ECM40/60
models (contact sales for 2 x MOPP),
1500 VAC Input to Ground 1 x MOPP,
500 VAC Output to Ground
Switching Frequency • 70 kHz typical
Power Density • 40 W: 4.2 W/In3
60 W: 6.3 W/In3
100 W: 7.4 W/In3
MTBF • 600 kHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature • 0 °C to +70 °C. Refer to derating curves
for specific operating limitations.
Cooling • Convection & fan-cooled ratings
(see derating curves)
Operating Humidity • 95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Operating Altitude • 3000 m
Shock • 30 g pk, half sine, 6 axes
Vibration • 2 g rms, 5 Hz to 500 Hz, 3 axes
EMC & Safety
Emissions • EN60601-1-2, EN61204-3, FCC 20780,
EN55022 & EN55011, level B conducted
EN55022 Level A radiated
Harmonic Currents • EN61000-3-2, class A
Voltage Flicker • EN61000-3-3
ESD Immunity • EN61000-4-2, level 3 Perf Criteria A
Radiated Immunity • EN61000-4-3, 10 V/m Perf Criteria A
EFT/Burst • EN61000-4-4, level 3 Perf Criteria A
Surge • EN61000-4-5, level 3 Perf Criteria A,
SEMI F47
Conducted Immunity • EN61000-4-6, 10 V Perf Criteria A
Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
EN60601-1, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms,
Perf Criteria A, A (with 50% load), A, B
Safety Approvals • EN60601-1, ANSI/AAMI ES60601-1,
CSA22.2 No.60601-1 per cUL, Including
Risk Management, EN60950-1, UL60950-1