AS168XAC3 Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 OU T Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 3 poles See below: Approvals and Compliances Description - Thermal-magnetic circuit breaker High short circuit performance Availability of AC and DC in the same frame size DIN-Rail Mounting Applications - Industrial appliances References Last order possibility: 31.08.2018 Last delivery date: 30.09.2018 Weblinks Technical Data General data Rated Voltage AC Rated Voltage DC Rated current Conditional short circuit capacity IEC 60934 Conditional short circuit capacity UL 1077 E- pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Detailed request for product, Product News Tripping Type Actuation Type Permissible wire cross section Switched neutral Rated Voltage Rated current Function Add-on modules Add-on modules Positively trip free Manual ON/OFF 1.5 - 25 mm / 16 - 4 AWG AC 277 V AC/DC 65 A The switched neutral closes with manual closure of the poles and opens automatically with thermal magnetic tripping of the poles. Technical data for the additional module see separate data sheet PH AS IEC : 420 V Y / 240 V;50/60 Hz UL/CSA : 480 V Y / 277 V;50/60 Hz 65 V 0.5 - 52 A , see approbations Icn: AC 420 V Y/240 V / DC 65 V: 5 kA (no fuse) Inc: AC 480 V Y/277 V: 10 kA (with fuse class H/J, 4x rated current (min. 15 A)) Icn: AC 480 V Y/277 V: 5 kA (no fuse) Icn: DC 65 V: 2 kA (no fuse) Conditional short circuit capa- Icn: AC 480 V Y/277 V: 5 kA (no fuse) city UL 508 Degree of Protection from front side IP 40 acc. to IEC 60529 Lifetime 1 x Ir 6000 switching cycles Dielectric Strength 50 Hz: > 2 kV Impulse 1.2/50 s Vibration Resistance 0.75 mm @ 5 - 60 Hz acc. to IEC 60068-2-6, test Fc 10 G @ 60 - 500 Hz acc. to IEC 60068-2-6, test Fc Insulation Resistance 250/440 VAC > 5 M Shock Resistance 30 G / 18 ms acc. to IEC 60068-2-27, test Ea Ambient temperature -10 C to 55 C Weight 100 - 130 g Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Circuit Breakers 1 AS168XAC3 Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: AS168X Certification Body Description VDE Approvals VDE VDE Certificate Number: 40005743 UL Approvals UL UL File Number: E216629 / E71572 UL Approvals UL UL File Number: E216629 / E71572 Product standards Product standards that are referenced Organization Design Standard Designed according to IEC 60934 Designed according to UL508, UL1077 Designed according to UL 508 Designed according to CSA C22.2 Application standards Application standards where the product can be used Design Standard Designed for applications acc. Standard for Supplementary Protectors for Use in Electrical Equipment Standard for Industrial Control Equipment Supplementary Protectors Description IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Initiator Description SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. The product complies with following Guide Lines Details CE declaration of conformity PH AS RoHS 2 Circuit-breakers for equipment (CBE) IEC/UL 60950 Compliances Identification Description E- Organization T Certificates OU Approval Logo Circuit Breakers AS168XAC3 Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 Dimension [mm] AS168X 3 pole A) 35 1.9 90 B) T 5.1 26.6 44.4 OU 68.4 61.6 45 52.5 A) 35 mm DIN rail EN 50022 B) Max. torque AS168X 3 pole and switched neutral pole Max. torque 2.5 Nm 3.1 Nm 20 ... 22 lb -in 26 ... 28 lb -in E- Wire crosssection 1.5 ... 10 mm2 16 ... 25 mm2 AWG #16 ... 8 AWG #6 ... 4 68.4 A) 5.1 35 26.6 44.4 61.6 AS 45 70 PH 1.9 90 B) A) 35 mm DIN rail EN 50022 B) Max. torque Wire crosssection 1.5 ... 10 mm2 16 ... 25 mm2 AWG #16 ... 8 AWG #6 ... 4 Max. torque 2.5 Nm 3.1 Nm 20 ... 22 lb -in 26 ... 28 lb -in Circuit Breakers 3 AS168XAC3 Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 Diagrams AS168X-CB1...N OU T AS168X-CB1... AS168X-CB1... / AS168X-ACBS2 AS AS168X-CB1... / AS168X-ACBS1 AS168X-CB1... / AS168X-ACBH2 E- AS168X-CB1... / AS168X-ACBH1 PH AS168X-CB1... / AS168X-ACBA 4 Circuit Breakers AS168XAC3 Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 Standard Rated current Rated voltage AC Conditional short circuit capacity Icn Rated voltage DC Conditional short circuit capacity Icn UL 508 CSA C22.2 no. 14 0.5 - 52 A 480Y/277 V 5 kA - - UL 1077 0.5 - 40 A 480 V 10 kA - - 0.5 - 50 A 480 V 5 kA 0.5 - 30 A 240/420 V 4.5 kA GB 17701 - - - Effect of ambient temperature 65 V 2 kA 65 V 4.5 kA - - T CSA C22.2 no. 235 EN 60934 OU Symbol AC-breaker are calibrated for an ambient temperature of +40C, DC-breakers for +23C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below: Ambient temperature [C] Correction factor AC version Correction factor DC version -20 0.78 0.80 -5 0.82 0 0.83 +10 0.87 +23 0.91 +30 0.95 +40 1.00 +50 1.05 +60 1.11 0.87 0.90 0.95 1.00 1.05 1.10 1.20 E- 1.30 PH AS Example DC version: Rated current = 10 A; Environmental temperature = 50 C; --> Correction factor = 1.2; Resulting current = 12 A Circuit Breakers 5 AS168XAC3 Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 Ampere-Horsepower Horsepower (FLA & LRC Ratings Apply where no HP Rating is given) 110120 AS168X-CB FLA Rating 0.5A 1A 1.5A 2A 3A 4A 5A 6A 7A 8A 9A 10A 12A 13A 15A 16A 18A 20A 23A 25A 27A 30A Starting/ LRC Rating 3 6 9 12A 18A 24A 30A 36A 42A 48A 54A 60A 72A 78A 90A 96A 108A 120A 138A 150A 162A 180A Motor Nameplate FLA Rating 0.5A 1A 1.5A 2A 3A 4A 5A 6A 7A 8A 9A 10A 12A 13A 15A 16A 18A 20A 23A 25A 27A 30A 1/10 1/8 1/6 1/4 1/4 1/3 1/3 1/2 1/2 1/2 3/4 1 1 1 1/2 1 1/2 2 2 2 1/6 1/4 1/3 1/2 1/2 3/4 3/4 1 1 1/2 1 1/2 2 2 2 3 3 3 3 3 1/10 1/8 1/4 1/3 1/2 1/2 3/4 1 1 1 1/2 2 2 2 2 3 3 3 3 3 5 1/6 1/3 1/3 1/2 1/2 3/4 1 1 1 1/2 1 1/2 2 2 2 3 3 3 3 3 1/10 1/6 1/3 1/3 1/2 3/4 1 1 1 1/2 2 2 2 3 3 3 3 3 5 5 5 1/10 1/6 1/4 1/3 1/2 3/4 1 1 1/2 2 2 2 3 3 3 3 5 5 5 5 7 1/2 7 1/2 Starting/ LRC Rating PH 10A 12.5A 20A 25A 32A 32A 32A 46A 46A 46A 63.5A 63.5A 81A 81A 81A 81A 116A 116A 145A 145A 1/2 1/2 3/4 3/4 1 1 1 1/2 1 1/2 2 2 2 3 3 3 3 3 1/2 3/4 1 1 1/2 2 2 2 3 3 3 3 5 5 5 5 7 1/2 7 1/2 1/2 3/4 1 1 1/2 2 2 2 3 3 3 3 5 5 5 7 1/2 7 1/2 7 1/2 Note #1: For AC motor circuit nameplate FLA loads, AC general-use loades, AC resistance loads 6 1/10 1/6 1/4 1/3 1/2 3/4 1 1 1 1 1/2 2 2 3 3 3 3 3 5 5 5 2 pole Horsepower (FLA & LRC Ratings Apply where no HP Rating is given) Nominal Circuit Voltage, VAC 110-120 200 208 220-240 380-415 AS Rated Current (See Note #1) 0.5A 1A 1.5A 2A 3A 4A 5A 6A 7A 8A 9A 10A 12A 13A 15A 16A 18A 20A 23A 25A 27A 30A Circuit Breakers 440480 380415 1 pole E- Rated Current (See Note #1) 0.5A 1A 1.5A 2A 3A 4A 5A 6A 7A 8A 9A 10A 12A 13A 15A 16A 18A 20A 23A 25A 27A 30A 200 Nominal Circuit Voltage, VAC 220208 265 277 240 T Motor Nameplate OU AS168X-CB 1/2 1 1 1/2 2 2 2 3 3 3 3 5 5 5 5 7 1/2 7 1/2 10 10 440-480 3 pole 1/2 3/4 1 1/2 2 2 2 3 3 3 3 5 5 5 7 1/2 7 1/2 7 1/2 10 1/2 3/4 1 1 1/2 2 2 3 3 3 5 5 5 7 1/2 7 1/2 10 10 10 10 15 15 1/2 3/4 1 1/ 2 2 3 3 3 5 5 5 7 1/ 2 7 1/ 2 10 10 10 10 15 15 20 20 AS168XAC3 Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 Time-Current-Curves 1hr 1000s 1000s 100s 100s 10s 10s OU 1hr 1s 0,1s 10ms T Version G / Magnetic 6-10 xln Time in Seconds Time in Seconds Version F / Magnetic 3-5 xln 1s 0,1s 10ms 1ms 1ms 0,1ms 0,1ms 1 10 100 1000 x In Multiple of Rated Current In 1 10 100 1000 x In Multiple of Rated Current In Reference Temperature +23 E- Reference Temperature +23 Version H / Magnetic 12-20 xln 1hr 1000s AS 100s Time in Seconds 10s 1s 0,1s 10ms PH 1ms 0,1ms 1 10 100 1000 x In Multiple of Rated Current In Reference Temperature +23 Config. Code AS168X-CB|1|DG|200|N| The characters are placeholders for the correspondingly keys of selections from the key tables. AS168X-CB| 1 |DG|200|N| = Number of Poles Number of Poles Configuration key 3-pole 3 Circuit Breakers 7 AS168XAC3 Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 AS168X-CB|1| DG |200|N| = Tripping characteristics Configuration key 1.0-1.25xIn / 3-5xIn / 0.5-52 A F 1.0-1.25xIn / 6-10xIn / 0.5-52 A G 1.0-1.25xIn / 12-20xIn / 0.5-52 A H 12.0 A 120 15.0 A 150 16.0 A 160 18.0 A 180 20.0 A 200 23.0 A AS168X-CB|1|DG| 200 |N| = Rated current 230 25.0 A Configuration key 250 27.0 A 270 30.0 A OU Rated current Configuration key T Tripping characteristics Rated current 0.05 A 005 1.0 A 010 1.5 A 015 2.0 A 020 3.0 A 030 4.0 A 040 050 6.0 A 060 7.0 A 070 8.0 A 080 9.0 A 090 10.0 A 100 Other rated currents on request Variants Rated current 1.0-1.25xIn / 3-5xIn / 0.5-52 A 30.0 A 350 40.0 A 400 45.0 A 450 50.0 A 500 52.0 A 520 Other rated currents on request AS168X-CB|1|DG|200| N | = Switched neutral Switched neutral Configuration key Switched neutral pole Switched neutral AS Tripping characteristics 320 35.0 A E- 5.0 A 300 32.0 A Config. Code Order Number AS168X-CB3F300 4420.0742 1.0-1.25xIn / 3-5xIn / 0.5-52 A 35.0 A AS168X-CB3F350 4420.0994 1.0-1.25xIn / 6-10xIn / 0.5-52 A 2.0 A AS168X-CB3G020 4420.0402 1.0-1.25xIn / 6-10xIn / 0.5-52 A 3.0 A AS168X-CB3G030 4420.0400 1.0-1.25xIn / 6-10xIn / 0.5-52 A 4.0 A AS168X-CB3G040 4420.0388 1.0-1.25xIn / 6-10xIn / 0.5-52 A 5.0 A AS168X-CB3G050 4420.0301 N 1.0-1.25xIn / 6-10xIn / 0.5-52 A 10.0 A AS168X-CB3G100 4420.0241 1.0-1.25xIn / 6-10xIn / 0.5-52 A 15.0 A AS168X-CB3G150 4420.0204 1.0-1.25xIn / 6-10xIn / 0.5-52 A 20.0 A AS168X-CB3G200 4420.0198 25.0 A AS168X-CB3G250 4420.0242 30.0 A AS168X-CB3G300 4420.0210 PH 1.0-1.25xIn / 6-10xIn / 0.5-52 A 1.0-1.25xIn / 6-10xIn / 0.5-52 A 1.0-1.25xIn / 6-10xIn / 0.5-52 A 32.0 A AS168X-CB3G320 4420.0323 1.0-1.25xIn / 6-10xIn / 0.5-52 A 40.0 A AS168X-CB3G400 4420.0199 1.0-1.25xIn / 12-20xIn / 0.5-52 A 15.0 A AS168X-CB3H150 4420.0569 1.0-1.25xIn / 12-20xIn / 0.5-52 A 20.0 A AS168X-CB3H200 4420.0308 1.0-1.25xIn / 12-20xIn / 0.5-52 A 25.0 A AS168X-CB3H250 4420.0542 1.0-1.25xIn / 12-20xIn / 0.5-52 A 30.0 A AS168X-CB3H300 4420.0287 1.0-1.25xIn / 12-20xIn / 0.5-52 A 40.0 A AS168X-CB3H400 4420.0372 1.0-1.25xIn / 12-20xIn / 0.5-52 A 50.0 A AS168X-CB3H500 4420.0762 Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER 8 Circuit Breakers AS168XAC3 Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 1 Pcs The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 19.02.2018 PH AS E- OU T Packaging Unit Circuit Breakers 9 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Schurter: 4429.0003