SPECIFICATION
OPERATING ALTITUDE Note.8 5000 meters
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE Note.2
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.6
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING HUMIDITY
WORKING TEMP.
OVER TEMPERATURE
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load
40ms/230VAC 12ms/115VAC at full load
80 ~ 264VAC
47 ~ 440Hz
0.2A/115VAC 0.1A/230VAC
COLD START 25A/115VAC 45A/230VAC
110% ~ 180% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
20 ~ 90% RH non-condensing
-40 ~ +85℃ (Refer to "Derating Curve")
±0.03%/℃ (0 ~ 60℃)
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
1799.5Khrs min. MIL-HDBK-217F (25℃)
45.7*25.4*21.5mm (L*W*H) or 1.8*1.0"0.85" inch
SAFETY STANDARDS
RIPPLE & NOISE (max.) Note.4
VOLTAGE TOLERANCE Note.5
℃
℃ ℃
ENVIRONMENT
SAFETY &
EMC
(Note 9)
PROTECTION
Protection type : Shut off o/p voltage, clamping by zener diode
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
I/P-O/P:4KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
rd
IEC60601-1, EN60601-1, , UL ANSI/AAMI ES60601-1(3.1 version), CAN/CSA-C22 3 Edition approved ; Design EAC TP TC 004
refer to EN60335-1
LEAKAGE CURRENT (max.) Note.7
Touch current <80 A/264VAC
μ
ISOLATION LEVEL Primary-Secondary: 2xMOPP
Parameter
Parameter
Conducted
Radiated
Harmonic Current
Voltage Flicker
Standard
Standard
EN55011 (CISPR11)
EN55011 (CISPR11)
EN61000-3-2
EN61000-3-3
Test Level / Note
Test Level / Note
Class B
Class B
Class A
-----
EMC IMMUNITY
EMC EMISSION
MPM-05-3.3 MPM-05-5 MPM-05-12 MPM-05-15 MPM-05-24
±0.3%
±0.5%
±0.3%
±0.5%
±0.3%
±0.5%
±0.3%
±0.5%
±0.3%
±0.5%
±2.5% ±2.5% ±2.5% ±2.5%±2.5%
100mVp-p100mVp-p 150mVp-p 150mVp-p 180mVp-p
5V3.3V 12V 15V 24V
1A1.25A 0.42A 0.33A 0.23A
0 ~ 1A0 ~ 1.25A 0 ~ 0.42A 0 ~ 0.33A 0 ~ 0.23A
5W4.1W 5W 5W 5.5W
80% 74% 80% 81% 82%
13.8 ~ 16.2V 17.3 ~ 20.3V 27.6 ~ 32.4V
5.8 ~ 6.8V3.8 ~ 5V
SOLDERING TEMPERATURE 260℃±5℃/10sec.max.
PEAK CURRENT 1.38A 1.1A 0.46A 0.36A 0.25A
MPM-05 serie s
0.035Kg; 270pcs/10.5Kg/0.97CUFT
PEAK LOAD(10sec.) Note.3
4.6W 5.5W 5.5W 5.4W 6W
-40 ~ +100℃, 10 ~ 95% RH non-condensing
μ μ
5W High Reliable Green Medical Encapsulated Type
ESD EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11 100% dip 1 periods, 30% dip 25 periods,
100% interruptions 250 periods
Level 4, 15KV air ; Level 4, 8KV contact
Level 3, 1KV/Line-Line
EN60601-1-2
RF field susceptibility
EFT bursts
Surge susceptibility
Conducted susceptibility
Magnetic field immunity Level 4, 30A/m
Level 3, 10V
Level 3, 2KV
Voltage dip, interruption
Level 3, 10V/m( 80MHz~2.7GHz )
Table 9, 9~28V/m( 385MHz~5.78GHz )
File Name:MPM-05-SPEC 2018-01-12