PLA-2
PLA15F
AC-DC Power Supplies Enclosed Type
PL A 15 F -O -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional
*7
C
: with Coating
J
: Connector interface
T
:
Vertical terminal block
-NO : with DIN rail
R
1 2 3 4 5 6
SPECIFICATIONS
MODEL PLA15F-5 PLA15F-12 PLA15F-15 PLA15F-24
INPUT
VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
*3
CURRENT[A]
ACIN 100V
0.4typ (Io=90%)
ACIN 115V
0.4typ (Io=100%)
ACIN 230V
0.25typ (Io=100%)
FREQUENCY[Hz] 50 / 60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
72.5typ (Io=90%) 75.5typ (Io=90%) 77.0typ (Io=90%) 78.0typ (Io=90%)
ACIN 115V
73.5typ (Io=100%) 77.0typ (Io=100%) 78.5typ (Io=100%) 79.0typ (Io=100%)
ACIN 230V
75.5typ (Io=100%) 78.5typ (Io=100%) 79.5typ (Io=100%) 80.0typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
16typ (Io=90%) Ta=25C at cold start
ACIN 115V
16typ (Io=100%) Ta=25C at cold start
ACIN 230V
32typ (Io=100%) Ta=25C at cold start
LEAKAGE CURRENT[mA] 0.30max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
OUTPUT
VOLTAGE[V] 5 12 15 24
CURRENT[A] 3 1.3 1 0.7
WATTAGE[W]
ACIN 85-115V
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V
15.0 15.6 15.0 16.8
LINE REGULATION[mV]
*
4
20max 48max 60max 96max
LOAD REGULATION[mV]
*
4
40max 100max 120max 150max
RIPPLE[mVp-p]
*1
0 to +50C
80max 120max 120max 120max
-10 to 0C
140max 160max 160max 160max
Io=0 to 35%
160max 240max 240max 280max
RIPPLE NOISE[mVp-p]
*1
0 to +50C
120max 150max 150max 150max
-10 to 0C
160max 180max 180max 180max
Io=0 to 35%
240max 300max 300max 320max
TEMPERATURE REGULATION[mV]
0 to +50C
50max 120max 150max 240max
-10 to +50C
60max 150max 180max 290max
DRIFT[mV]
*
2
20max 48max 60max 96max
START-UP TIME[ms] 200typ (ACIN 115V, Io=100%)
*Start-up time is 700 ms typ for less than 1 minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40
OUTPUT VOLTAGE SETTING[V]
5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60
OPERATING INDICATION LED (Green)
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*
5
-20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes
IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
HARMONIC ATTENUATOR
*
8
Complies with IEC61000-3-2 class A
Example recommended EMI/EMC filter
NAC-04-472
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
See 5.1 in Instruction Manual.
PLA-3
PLA15F
External view
Features
*1 This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150
mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-
Giken RM103.
See 1.6 of Instruction Manual for more details.
When the load factor is 0 - 35%, the switching power loss is reduced by burst operation, which will
cause ripple and ripple noise to go beyond the specifications.
*2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
As for DC input, consult us for advice.
*4
Consult us about dynamic load and input response. Measure the output voltage by using the average mode
of the tester to deal with the burst operation at 35% load or less.
*5
Output power derating is required. See 3.2 in Instruction Manual.
*6
See 3.3 in Instruction Manual for more details.
*7
Consult us about safety agency approvals for the models with optional functions.
*8
Consult us about other classes.
*
Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges.
Otherwise the internal components may be damaged.
* Parallel operation is not possible with this mode.
*
Sound noise may be heard from the power supply when used for pulse load.
Block diagram
OTHERS CASE SIZE/WEIGHT 38X80X73mm [1.50X3.15X2.87 inches] (Excluding terminal block and screw) (WXHXD) / 250g max
COOLING METHOD Convection
WARRANTY WARRANTY
*
6
5 years (subject to the operating conditions)
FG
OVER VOLTAGE
PROTECTION
RECTIFIER
AND
FILTER
DC OUT
FUSE
AC250V2.5A
CONTROL
TRANSFORMER
Photocoupler
Photocoupler
CONTROL INVERTER
OVER CURRENT
SENSING
AC IN 85 - 264V NOISE
FILTER
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
-
Compact design (Depth: 73mm 2.87inches)
-
Low power consumption (1.0W typ AC240Vin, no load at standard model)
-
UL508 approved (Except option -J), and complies with SEMI F47
-
Various connection interface options (vertical terminal [-T], AMP connector [-J])
SPECIFICATIONS
Output voltage
adjustable potentiometer
Output terminal(+)
Output terminal(-)
FG( )
AC(N)
AC(L)
M3.5
TB1
[0.49]
[0.32]
[0.37]
[0.24]
[0.67]
[0.5]
[0.26]
Name plate
Terminal cover
8.2
9.56.2
17
±1.5
12.7
±1.5
6.5
±1.5
12.5max
[1.5]
[0.79]
[1.81]
[0.71]
[0.79]
Mounting hole
2-M3
20
20
38
18 46 ±0.5
[2.87]
[1.83]
[3.15]
[1.4]
[0.71]
46.5
80
73
18 35.5 ±0.5
Point A
Mounting hole
(Bottom side)
2-M3
Tolerance : ±1 [±0.04]
Weight
:
250g max
PCB Material/thickness
:
CEM-3 / 1.6mm [0.06inches]
Chassis material
:
Electric galvanizing steel board
Case material : Electric galvanizing steel board
Dimensions in mm, [ ]=inches
Mounting torque
:
0.6N
-m max
Screw tightening torque : 1.0N-m max
V.ADJ
[0.55]
14
±1.5
[0.6]
(LED)15.3
±1.5
[0.46]
(Potentiometer)11.6
±1.5
LED
PLA-4
PLA30F
AC-DC Power Supplies Enclosed Type
PL A 30 F -O -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional
*7
C
: with Coating
J
: Connector interface
T
:
Vertical terminal block
-NO : with DIN rail
R
1 2 3 4 5 6
Example recommended EMI/EMC filter
NAC-04-472
SPECIFICATIONS
MODEL PLA30F-5 PLA30F-12 PLA30F-15 PLA30F-24
INPUT
VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
*3
CURRENT[A]
ACIN 100V
0.7typ (Io=90%)
ACIN 115V
0.7typ (Io=100%)
ACIN 230V
0.4typ (Io=100%)
FREQUENCY[Hz] 50 / 60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
73.0typ (Io=90%) 80.0typ (Io=90%) 81.0typ (Io=90%) 82.5typ (Io=90%)
ACIN 115V
74.0typ (Io=100%) 80.5typ (Io=100%) 81.5typ (Io=100%) 83.0typ (Io=100%)
ACIN 230V
77.0typ (Io=100%) 81.0typ (Io=100%) 82.0typ (Io=100%) 83.5typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
16typ (Io=90%) Ta=25C at cold start
ACIN 115V
16typ (Io=100%) Ta=25C at cold start
ACIN 230V
32typ (Io=100%) Ta=25C at cold start
LEAKAGE CURRENT[mA] 0.65max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
OUTPUT
VOLTAGE[V] 5 12 15 24
CURRENT[A] 6 2.5 2 1.3
WATTAGE[W]
ACIN 85-115V
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V
30.0 30.0 30.0 31.2
LINE REGULATION[mV]
*
4
20max 48max 60max 96max
LOAD REGULATION[mV]
*
4
40max 100max 120max 150max
RIPPLE[mVp-p]
*1
0 to +50C
80max 120max 120max 120max
-10 to 0C
140max 160max 160max 160max
RIPPLE NOISE[mVp-p]
*1
0 to +50C
120max 150max 150max 150max
-10 to 0C
160max 180max 180max 180max
TEMPERATURE REGULATION[mV]
0 to +50C
50max 120max 150max 240max
-10 to +50C
60max 150max 180max 290max
DRIFT[mV]
*
2
20max 48max 60max 96max
START-UP TIME[ms] 150typ (ACIN 115V, Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40
OUTPUT VOLTAGE SETTING[V]
5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60
OPERATING INDICATION LED (Green)
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*
5
-20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes
IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
HARMONIC ATTENUATOR
*
8
Complies with IEC61000-3-2 class A
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
See 5.1 in Instruction Manual.
PLA-5
PLA30F
External view
Features
Block diagram
FG
OVER VOLTAGE
PROTECTION
RECTIFIER
AND
FILTER
DC OUT
FUSE
AC250V3.15A
CONTROL
CONTROL INVERTER
AC IN 85 - 264V
TRANSFORMER
Photocoupler
Photocoupler
OVER CURRENT
SENSING
NOISE
FILTER
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
-
Compact design (Depth: 88mm 3.46inches)
-
UL508 approved (Except option -J), and complies with SEMI F47
-
Various connection interface options (vertical terminal [-T], AMP connector [-J])
*1 This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150
mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-
Giken RM103.
See 1.6 of Instruction Manual for more details.
*2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
As for DC input, consult us for advice.
*4
Consult us about dynamic load and input response.
*5
Output power derating is required. See 3.2 in Instruction Manual.
*6
See 3.3 in Instruction Manual for more details.
*7
Consult us about safety agency approvals for the models with optional functions.
*8
Consult us about other classes.
*
Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges.
Otherwise the internal components may be damaged.
* Parallel operation is not possible with this mode.
*
Sound noise may be heard from the power supply when used for pulse load.
OTHERS CASE SIZE/WEIGHT 38X80X88mm [1.50X3.15X3.46 inches] (Excluding terminal block and screw) (WXHXD) / 330g max
COOLING METHOD Convection
WARRANTY WARRANTY
*
6
5 years (subject to the operating conditions)
SPECIFICATIONS
V.ADJ
TB1
M3.5
AC(L)
AC(N)
FG( )
Output terminal(
-
)
Output terminal(+)
Output voltage
adjustable potentiometer
Name plate
[0.5]
[0.24] [0.37]
[0.32]
6.5
±1.5
12.7
±1.5
17
±1.5
6.2 9.5
8.2
Mounting hole
2-M3
Terminal cover
[0.49]
[0.79]
[1.5] [1.61]
12.5max
20
38 41
±0.5
[1.5]
[0.79]
20
38
Mounting hole
(Bottom side)
2-M3
[1.71]
[3.15]
43.5
80
Point A
[3.46]
[2.46]
[0.75]
62.5
±0.5
88
19
Tolerance : ±1 [±0.04]
Weight
:
330g max
PCB Material/thickness
:
CEM-3 / 1.6mm [0.06inches]
Chassis material
:
Electric galvanizing steel board
Case material : Electric galvanizing steel board
Dimensions in mm, [ ]=inches
Mounting torque
:
0.6N
-m max
Screw tightening torque : 1.0N-m max
[0.67]
[0.26]
[0.46]
(Potentiometer)
11.6
±1.5
[0.6]
(LED)
15.3
±1.5
[0.55]
14
±1.5
LED
PLA-6
PLA50F
AC-DC Power Supplies Enclosed Type
PL A 50 F -O -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional
*7
C
: with Coating
J
: Connector interface
T
:
Vertical terminal block
-NO : with DIN rail
R
1 2 3 4 5 6
Example recommended EMI/EMC filter
NAC-04-472
SPECIFICATIONS
MODEL PLA50F-5 PLA50F-12 PLA50F-15 PLA50F-24
INPUT
VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
*3
CURRENT[A]
ACIN 100V
0.6typ (Io=90%) 0.7typ (Io=90%)
ACIN 115V
0.6typ (Io=100%) 0.7typ (Io=100%)
ACIN 230V
0.3typ (Io=100%) 0.4typ (Io=100%)
FREQUENCY[Hz] 50 / 60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
74.5typ (Io=90%) 80.0typ (Io=90%) 80.0typ (Io=90%) 81.5typ (Io=90%)
ACIN 115V
75.0typ (Io=100%) 80.5typ (Io=100%) 80.5typ (Io=100%) 82.0typ (Io=100%)
ACIN 230V
76.5typ (Io=100%) 82.0typ (Io=100%) 82.0typ (Io=100%) 84.0typ (Io=100%)
POWER FACTOR
ACIN 100V
0.97typ (Io=90%) 0.98typ (Io=90%)
ACIN 115V
0.97typ (Io=100%) 0.98typ (Io=100%)
ACIN 230V
0.85typ (Io=100%) 0.87typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
16typ (Io=90%) Ta=25C at cold start
ACIN 115V
16typ (Io=100%) Ta=25C at cold start
ACIN 230V
32typ (Io=100%) Ta=25C at cold start
LEAKAGE CURRENT[mA] 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
OUTPUT
VOLTAGE[V] 5 12 15 24
CURRENT[A] 8 4.3 3.5 2.2
WATTAGE[W]
ACIN 85-115V
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V
40.0 51.6 52.5 52.8
LINE REGULATION[mV]
*
4
20max 48max 60max 96max
LOAD REGULATION[mV]
*
4
40max 100max 120max 150max
RIPPLE[mVp-p]
*1
0 to +45C
80max 120max 120max 120max
-10 to 0C
140max 160max 160max 160max
RIPPLE NOISE[mVp-p]
*1
0 to +45C
120max 150max 150max 150max
-10 to 0C
160max 180max 180max 180max
TEMPERATURE REGULATION[mV]
0 to +45C
50max 120max 150max 240max
-10 to +45C
60max 150max 180max 290max
DRIFT[mV]
*
2
20max 48max 60max 96max
START-UP TIME[ms] 350typ (ACIN 115V, Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40
OUTPUT VOLTAGE SETTING[V]
5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60
OPERATING INDICATION LED (Green)
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*
5
-20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes
IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
HARMONIC ATTENUATOR
*
8
Complies with IEC61000-3-2 class A
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
See 5.1 in Instruction Manual.
PLA-7
PLA50F
External view
Features
Block diagram
FG
OVER VOLTAGE
PROTECTION
NOISE
FILTER RECTIFIER
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
DC OUT
FUSE
AC250V 2.5A
CONTROL
CONTROL
CONTROL
INVERTER
RECTIFIER
AND
FILTER
INVERTER
BOOSTER
INDUCTOR CURRENT
SENSING
AC IN 85 - 264V
TRANSFORMER
Photocoupler
Photocoupler
OVER CURRENT
SENSING
-
Compact design (Depth: 99mm 3.90inches)
-
UL508 approved (Except option -J), and complies with SEMI F47
-
Various connection interface options (vertical terminal [-T], AMP connector [-J])
*1 This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150
mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-
Giken RM103.
See 1.6 of Instruction Manual for more details.
*2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
As for DC input, consult us for advice.
*4
Consult us about dynamic load and input response.
*5
Output power derating is required. See 3.2 in Instruction Manual.
*6
See 3.3 in Instruction Manual for more details.
*7
Consult us about safety agency approvals for the models with optional functions.
*8
Consult us about other classes.
*
Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges.
Otherwise the internal components may be damaged.
* Parallel operation is not possible with this mode.
*
Sound noise may be heard from the power supply when used for pulse load.
OTHERS CASE SIZE/WEIGHT 38X80X99mm [1.50X3.15X3.90 inches] (Excluding terminal block and screw) (WXHXD) / 400g max
COOLING METHOD Convection
WARRANTY WARRANTY
*
6
5 years (subject to the operating conditions)
SPECIFICATIONS
V.ADJ
Output voltage
adjustable potentiometer
Output terminal(+)
Output terminal(
-
)
FG( )
AC(N)
AC(L)
M3.5
TB1
[0.49]
[0.32]
[0.37]
[0.24]
[0.67]
[0.5]
[0.26]
Name plate
Terminal cover
8.2
9.56.2
17
±1.5
12.7
±1.5
6.5
±1.5
12.5max
[1.5]
[0.79]
[2.05]
[1.5]
[0.79]
Mounting hole
2-M3
38
20
20
38 52
±0.5
[3.15]
[1.75]
[2.99]
[0.75]
[3.9]
Mounting hole
(Bottom side)
2-M3
80
44.5
99
19 76
±0.5
Point A
Tolerance : ±1 [±0.04]
Weight
:
400g max
PCB Material/thickness
:
CEM-3 / 1.6mm [0.06inches]
Chassis material
:
Electric galvanizing steel board
Case material : Electric galvanizing steel board
Dimensions in mm, [ ]=inches
Mounting torque
:
0.6N
-m max
Screw tightening torque : 1.0N-m max
[0.6]
(LED)
15.3
±1.5
[0.46]
(Potentiometer)
11.6
±1.5
[0.55]
14
±1.5
LED
PLA-8
PLA100F
AC-DC Power Supplies Enclosed Type
PL A 100 F -O -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional
*7
C
: with Coating
R
: Remote on/off
(Required external
power source)
J
: Connector interface
T
:
Vertical terminal block
-NO : with DIN rail
See 5.1 in Instruction Manual.
R
1 2 3 4 5 6
SPECIFICATIONS
MODEL PLA100F-12 PLA100F-15 PLA100F-24 PLA100F-36 PLA100F-48
INPUT
VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
*
3
CURRENT[A]
ACIN 100V
1.2typ (Io=90%)
ACIN 115V
1.1typ (Io=100%)
ACIN 230V
0.6typ (Io=100%)
FREQUENCY[Hz] 50 / 60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
82typ (Io=90%) 83typ (Io=90%) 85typ (Io=90%) 86typ (Io=90%) 86typ (Io=90%)
ACIN 115V
82typ (Io=100%) 83typ (Io=100%) 85typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%)
ACIN 230V
85typ (Io=100%) 86typ (Io=100%) 88typ (Io=100%) 89typ (Io=100%) 89typ (Io=100%)
POWER FACTOR
ACIN 100V
0.98typ (Io=90%)
ACIN 115V
0.98typ (Io=100%)
ACIN 230V
0.95typ (Io=100%) * Power factor correction is stopped at AC250V or more.
INRUSH CURRENT[A]
ACIN 100V
16typ (Io=90%) Ta=25C at cold start
ACIN 115V
16typ (Io=100%) Ta=25C at cold start
ACIN 230V
32typ (Io=100%) Ta=25C at cold start
LEAKAGE CURRENT[mA] 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
OUTPUT
VOLTAGE[V] 12 15 24 36 48
CURRENT[A]
ACIN 85-115V
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V
8.4 6.7 4.3 2.8 2.1
WATTAGE[W]
ACIN 85-115V
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V
100.8 100.5 103.2 100.8 100.8
LINE REGULATION[mV]
*
4
48max 60max 96max 144max 192max
LOAD REGULATION
[mV]
*
4
Io=30 to 100%
100max 120max 150max 150max 300max
Io=0 to 30%
Burst operation (Please contact us about detail)
RIPPLE[mVp-p]
*1
Io: load factor
0 to +40C
120max 120max 120max 150max 150max
-10 to 0C
160max 160max 160max 200max 400max
Io=0 to 30%
500max 500max 500max 500max 500max
RIPPLE NOISE[mVp-p]
*1
Io: load factor
0 to +40C
150max 150max 150max 200max 200max
-10 to 0C
180max 180max 180max 240max 500max
Io=0 to 30%
600max 600max 600max 600max 600max
TEMPERATURE REGULATION[mV]
0 to +40C
120max 150max 240max 360max 480max
-10 to +40C
180max 180max 290max 440max 600max
DRIFT[mV]
*
2
48max 60max 96max 144max 192max
START-UP TIME[ms] 500typ (ACIN 115V, Io=100%) Ta=25C
HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80
OUTPUT VOLTAGE SETTING[V]
12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 54.00 to 67.20
OPERATING INDICATION LED (Green)
REMOTE SENSING Not provided
REMOTE ON/OFF Optional (Required external power source. Option -R)
ISOLATION
INPUT-OUTPUT RC
*
9
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
OUTPUT RC-FG
*
9
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
OUTPUT-RC
*
9
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*
5
-20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes
IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
HARMONIC ATTENUATOR
*
8
Complies with IEC61000-3-2 class A
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
Example recommended EMI/EMC filter
NAC-04-472
* Please consider "PBA100F-5-N" about 5V output with case cover.
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
PLA-9
Point A
Mounting hole
(Bottom side)
3-M3
Mounting hole
Terminal cover
2-M3
CN4
Connector for
Remote ON/OFF (option)
2
1
M3.5
Name plate
AC(L)
AC(N)
FG( )
Output terminal(–)
Output terminal(+)
Output voltage
adjustable potentiometer
LED
3.5
3.5
28.5
101
21
41
12 18±0.5
66.5±0.5
33.5
12.5max
97
109
51
19.5 76±0.5
21
4
14.6±1.5
22±1.5
6.2 9.5
8.2
32.8±1.5
[0.77]
[0.49] [4.29]
[2.99]
[0.16] [3.98]
[1.32] [2.62]
[0.32]
[0.86]
[0.24]
[0.83]
[0.83]
[0.47] [0.71]
[1.61]
[2.01]
[3.82]
[0.14]
[0.14]
[1.12]
[1.29]
[0.37]
[0.57]
14±1.5
[0.55]
15.3±1.5 (LED)
[0.6]
11.6±1.5 (potentiometer)
[0.46]
Tolerance : ±1 [±0.04]
Weight
:
500g max
PCB Material/thickness
:
CEM-3 / 1.6mm [0.06inches]
Chassis material
:
Aluminum
Cover material : Electric galvanizing steel board
Dimensions in mm, [ ]=inches
Mounting torque
:
0.49N
-m max
Screw tightening torque : M3.5 1.0N-m max
Connect the input FG to safety earth ground.
PLA100F
External view
Features
*1 This is the result of measurement of the testing board with
capacitors of 22mF and 0.1mF placed at 150 mm from the
output terminals by a 20 MHz oscilloscope or a ripple-noise meter
equivalent to Keisoku-Giken RM103.
See 1.6 of Instruction Manual for more details.
When the load factor is 0 - 30%, the switching power loss is
reduced by burst operation, which will cause ripple and ripple
noise to go beyond the specifications.
*2
Drift is the change in DC output for an eight hour period after a half-
hour warm-up at 25C.
*3
As for DC input, consult us for advice.
*4 Consult us about dynamic load and input response. Measure the output
voltage by using the average mode of the tester to deal with the burst
operation at 30% load or less.
*5
Output power derating is required. See 3.2 in Instruction Manual.
*6
See 3.3 in Instruction Manual for more details.
*7
Consult us about safety agency approvals for the models with optional functions.
*8 Consult us about other classes.
Block diagram
The external size of –R option, –J option, –N1 option and –T option models is different from the standard model. See “5. Options and
Others” in Instruction Manual for more details.
*9 The RC terminal is added to option –R models. The RC terminal is
isolated from input, output, and FG.
*
Do not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be
damaged.
* Parallel operation is not possible with this mode.
* Sound noise may be heard from the power supply when used for
pulse load.
OTHERS CASE SIZE/WEIGHT 41X97X109mm [1.61X3.82X4.29 inches] (Excluding terminal block and screw) (WXHXD) / 500g max
COOLING METHOD Convection
WARRANTY WARRANTY
*
6
5 years (subject to the operating conditions)
AC IN 85 - 264V
FG
DC OUT
RC(
-
R)
RECTIFIER
OVER VOLTAGE
PROTECTION
CURRENT
SENSING
NOISE
FILTER
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
FUSE
250V 3.15A
INVERTER
CONTROL
EXTERNAL
SOURCE
CONTROL
INVERTER
CURRENT
SENSING
RECTIFIER
AND
FILTER
BOOSTER
INDUCTOR
-
Compact design (Depth: 109mm 4.29inches)
-
High efficiency (88%typ PLA100F-24, AC230Vin, 100% load)
-
Low power consumption (1.5W typ AC240Vin, no load at standard model)
-
UL508 approved (Except option -J), and complies with SEMI F47 (see instruction manual 1.1)
-
Various connection interface options (vertical terminal [-T], AMP connector [-J])
SPECIFICATIONS
PLA-10
PLA150F
AC-DC Power Supplies Enclosed Type
PL A 150 F -O -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional
*7
C
: with Coating
R
: Remote on/off
(Required external
power source)
J
: Connector interface
T
:
Vertical terminal block
-NO : with DIN rail
See 5.1 in Instruction Manual.
R
1 2 3 4 5 6
SPECIFICATIONS
MODEL PLA150F-12 PLA150F-15 PLA150F-24 PLA150F-36 PLA150F-48
INPUT
VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
*
3
CURRENT[A]
ACIN 100V
1.7typ (Io=90%)
ACIN 115V
1.6typ (Io=100%)
ACIN 230V
0.8typ (Io=100%)
FREQUENCY[Hz] 50 / 60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
84typ (Io=90%) 84typ (Io=90%) 87typ (Io=90%) 87typ (Io=90%) 87typ (Io=90%)
ACIN 115V
84typ (Io=100%) 84typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%)
ACIN 230V
87typ (Io=100%) 87typ (Io=100%) 90typ (Io=100%) 90typ (Io=100%) 90typ (Io=100%)
POWER FACTOR
ACIN 100V
0.98typ (Io=90%)
ACIN 115V
0.98typ (Io=100%)
ACIN 230V
0.95typ (Io=100%) * Power factor correction is stopped at AC250V or more.
INRUSH CURRENT[A]
ACIN 100V
16typ (Io=90%) Ta=25C at cold start
ACIN 115V
16typ (Io=100%) Ta=25C at cold start
ACIN 230V
32typ (Io=100%) Ta=25C at cold start
LEAKAGE CURRENT[mA] 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
OUTPUT
VOLTAGE[V] 12 15 24 36 48
CURRENT[A]
ACIN 85-115V
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V
12.5 10 6.4 4.2 3.2
WATTAGE[W]
ACIN 85-115V
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V
150.0 150.0 153.6 151.2 153.6
LINE REGULATION[mV]
*
4
48max 60max 96max 144max 192max
LOAD REGULATION
[mV]
*
4
Io=30 to 100%
100max 120max 150max 150max 300max
Io=0 to 30%
Burst operation (Please contact us about detail)
RIPPLE[mVp-p]
*1
Io: load factor
0 to +40C
120max 120max 120max 150max 150max
-10 to 0C
160max 160max 160max 200max 400max
Io=0 to 30%
500max 500max 500max 500max 500max
RIPPLE NOISE[mVp-p]
*1
Io: load factor
0 to +40C
150max 150max 150max 200max 200max
-10 to 0C
180max 180max 180max 240max 500max
Io=0 to 30%
600max 600max 600max 600max 600max
TEMPERATURE REGULATION[mV]
0 to +40C
120max 150max 240max 360max 480max
-10 to +40C
180max 180max 290max 440max 600max
DRIFT[mV]
*
2
48max 60max 96max 144max 192max
START-UP TIME[ms] 500typ (ACIN 115V, Io=100%) Ta=25C
HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80
OUTPUT VOLTAGE SETTING[V]
12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 54.00 to 67.20
OPERATING INDICATION LED (Green)
REMOTE SENSING Not provided
REMOTE ON/OFF Optional (Required external power source. Option -R)
ISOLATION
INPUT-OUTPUT RC
*
9
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
OUTPUT RC-FG
*
9
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
OUTPUT-RC
*
9
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*
5
-20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes
IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
HARMONIC ATTENUATOR
*
8
Complies with IEC61000-3-2 class A
Example recommended EMI/EMC filter
NAC-04-472
* Please consider "PBA150F-5-N" about 5V output with case cover.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
PLA-11
PLA150F
External view
Features
*1 This is the result of measurement of the testing board with capacitors of
22mF and 0.1mF placed at 150 mm from the output terminals by a 20
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken
RM103.
See 1.6 of Instruction Manual for more details.
When the load factor is 0 - 30%, the switching power loss is reduced by
burst operation, which will cause ripple and ripple noise to go beyond
the specifications.
*2
Drift is the change in DC output for an eight hour period after a half-
hour warm-up at 25C.
*3
As for DC input, consult us for advice.
*4
Consult us about dynamic load and input response. Measure the output
voltage by using the average mode of the tester to deal with the burst
operation at 30% load or less.
*5
Output power derating is required. See 3.2 in Instruction Manual.
*6
See 3.3 in Instruction Manual for more details.
*7
Consult us about safety agency approvals for the models with optional functions.
*8 Consult us about other classes.
Block diagram
The external size of –R option, –J option, –N1 option and –T option models is different from the standard model. See “5. Options and
Others” in Instruction Manual for more details.
*9 The RC terminal is added to option –R models. The RC terminal
is isolated from input, output, and FG.
*
D
o not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be
damaged.
* Parallel operation is not possible with this mode.
* Sound noise may be heard from the power supply when used for
pulse load.
OTHERS CASE SIZE/WEIGHT 41X97X129mm [1.61X3.82X5.08 inches] (Excluding terminal block and screw) (WXHXD) / 600g max
COOLING METHOD Convection
WARRANTY WARRANTY
*
6
5 years (subject to the operating conditions)
AC IN 85 - 264V
FG
DC OUT
RC(
-
R)
RECTIFIER
OVER VOLTAGE
PROTECTION
CURRENT
SENSING
NOISE
FILTER
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
FUSE
250V 4A
INVERTER
CONTROL
EXTERNAL
SOURCE
CONTROL
INVERTER
CURRENT
SENSING
RECTIFIER
AND
FILTER
BOOSTER
INDUCTOR
-
Compact design (Depth: 129mm 5.08inches)
-
High efficiency (90%typ PLA150F-24, AC230Vin, 100% load)
-
Low power consumption (1.5W typ AC240Vin, no load at standard model)
-
UL508 approved (Except option -J), and complies with SEMI F47 (see instruction manual 1.1)
-
Various connection interface options (vertical terminal [-T], AMP connector [-J])
SPECIFICATIONS
LED
Output voltage
adjustable potentiometer
Output terminal(+)
Output terminal(–)
FG( )
AC(N)
AC(L)
Name plate
M3.5
2-M3
Mounting hole
3-M3
Mounting hole
(Bottom side)
Point A
B
Point B
2
1
CN4
Connector for
Remote ON/OFF (option)
Terminal cover
8.2
9.56.2
22±1.5
14.6±1.5
96±0.519
49.5
129
97
12.5max
48 70±0.5
18±0.5
12
41
21
121
28.5
3.5
3.5
21
4
32.8±1.5
[0.32]
[0.86]
[0.57]
[0.24]
[1.29]
[0.37]
[0.75]
[0.49] [5.08]
[3.78]
[1.95]
[3.82]
[0.16] [4.76]
[1.89] [2.76]
[0.83]
[0.83]
[0.47] [0.71]
[1.61]
[0.14]
[0.14]
[1.12]
14±1.5
[0.55]
15.3±1.5(LED)
[0.6]
11.6±1.5(potentiometer)
[0.46]
Tolerance : ±1 [±0.04]
Weight
:
600g max
PCB Material/thickness
:
CEM-3 / 1.6mm [0.06inches]
Chassis material
:
Aluminum
Cover material : Electric galvanizing steel board
Dimensions in mm, [ ]=inches
Mounting torque
:
0.49N
-m max
Screw tightening torque : M3.5 1.0N-m max
Connect the input FG to safety earth ground.
PLA-12
PLA300F
AC-DC Power Supplies Enclosed Type
PL A 300 F -O -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional
*7
C
: with Coating
G
: Low leakage current
V
:
External potentiometer for
output voltage adjustment
U
: Low input voltage stop
(Complies with SEMI F-47)
R
: Remote on/off
(Required external power source)
F4: Low speed fan
T2: Horizontal terminal block
(non-screw-hold type)
See 5.1 in Instruction Manual.
R
1 2 3 4 5 6
SPECIFICATIONS
MODEL PLA300F-5 PLA300F-12 PLA300F-15 PLA300F-24 PLA300F-36 PLA300F-48
INPUT
VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
*3
CURRENT[A]
ACIN 100V
3.1typ (Io=90%) 3.4typ (Io=90%)
ACIN 115V
3.0typ (Io=100%) 3.3typ (Io=100%)
ACIN 230V
1.5typ (Io=100%) 1.7typ (Io=100%)
FREQUENCY[Hz] 50 / 60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
73typ (Io=90%) 78typ (Io=90%) 79typ (Io=90%) 81typ (Io=90%) 81typ (Io=90%) 82typ (Io=90%)
ACIN 115V
74typ (Io=100%) 78typ (Io=100%) 80typ (Io=100%) 82typ (Io=100%) 82typ (Io=100%) 83typ (Io=100%)
ACIN 230V
77typ (Io=100%) 81typ (Io=100%) 83typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%)
POWER FACTOR
ACIN 100V
0.98typ (Io=90%)
ACIN 115V
0.98typ (Io=100%)
ACIN 230V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20typ (Io=90%) Ta=25C at cold start
ACIN 115V
20typ (Io=100%) Ta=25C at cold start
ACIN 230V
40typ (Io=100%) Ta=25C at cold start
LEAKAGE CURRENT[mA] 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
OUTPUT
VOLTAGE[V] 5 12 15 24 36 48
CURRENT[A]
ACIN 85-115V
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V
50 25 20 12.5 8.4 6.3
WATTAGE[W]
ACIN 85-115V
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V
250 300 300 300 302.4 302.4
LINE REGULATION[mV]
*
4
20max 48max 60max 96max 144max 192max
LOAD REGULATION[mV]
*
4
40max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]
*1
0 to +50C
80max 120max 120max 120max 150max 150max
-10 to 0C
140max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]
*1
0 to +50C
120max 150max 150max 150max 200max 200max
-10 to 0C
160max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
50max 120max 150max 240max 360max 480max
-10 to +50C
75max 180max 180max 290max 440max 600max
DRIFT[mV]
*
2
20max 48max 60max 96max 144max 192max
START-UP TIME[ms] 300typ (ACIN 115V, Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80
OUTPUT VOLTAGE SETTING[V]
5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20
OPERATING INDICATION LED (Green)
REMOTE SENSING Not provided
REMOTE ON/OFF Optional (Required external power source. Option -R)
ISOLATION
INPUT-OUTPUT RC
*
10
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
OUTPUT RC-FG
*
10
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
OUTPUT-RC
*
10
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*
5
-20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes
IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
HARMONIC ATTENUATOR
*
9
Complies with IEC61000-3-2 class A
Example recommended EMI/EMC filter
NAC-06-472
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
PLA-13
CONTROL FAN
AC IN 85 - 264V
FG
RECTIFIER
OVER VOLTAGE
PROTECTION
CURRENT
SENSING
THERMAL
PROTECTION
NOISE
FILTER
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
DC OUT
FUSE
250V 10A
INVERTER
CONTROL
CONTROL
CONTROL
INVERTER
CURRENT
SENSING
RECTIFIER
AND
FILTER
BOOSTER
INDUCTOR
PLA300F
External view
Features
*1 This is the result of measurement of the testing board with capacitors of
22mF and 0.1mF placed at 150 mm from the output terminals by a 20
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken
RM103.
See 1.6 of Instruction Manual for more details.
*2
Drift is the change in DC output for an eight hour period after a half-hour
warm-up at 25C.
*3
Output power derating is required. As for DC input, consult us for advice.
*4
Consult us about dynamic load and input response.
*5
See 3.2 in Instruction Manual.
*6
See 3.3 in Instruction Manual for more details.
*7
Consult us about safety agency approvals for the models with optional functions.
*8 The fan speed slows down at no load.
*9 Consult us about other classes.
*10
The RC terminal is added to option –R models. The RC terminal is
isolated from input, output, and FG.
Block diagram
The external size of –V option, –R option, and –T2 option models is different from the standard model. See “5. Options and Others” in
Instruction Manual for more details.
*
Do not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be
damaged.
* Parallel operation is not possible with this mode.
* Sound noise may be heard from the power supply when used for
pulse load.
-
Cost-effective
-
Longer life (see Instruction Manual)
-
Low profile (meets 1U height = 41 mm or 1.61 inches)
-
Wide operating temperature range (-20 to +70 see instruction manual)
-
Screw hold type terminal block
-
Slow fan speed at no load
-
Many optional functions
-
Complies with SEMI F-47 (-U option, see Instruction Manual for details)
OTHERS CASE SIZE/WEIGHT 102X41X190mm [4.02X1.61X7.48 inches] (Excluding terminal block and screw) (WXHXD) / 1.0kg max
COOLING METHOD
*
8
Forced cooling (internal fan)
WARRANTY WARRANTY
*
6
5 years (subject to the operating conditions)
SPECIFICATIONS
FG (N) AC
V.ADJ (L)
AC
-V-V+V+V
FG( )
AC(L)
AC(N)
Output terminal (+)
Output terminal (–)
Output voltage
adjustable potentiometer
LED
12.5
5.75
[0.23]
[0.49]
±
1.5
±
1.5
M4
[0.34]
5.7
19.8
[0.78]
±
1.5
8.6
10
[0.22][0.39]
4-M4
Mounting Hole
10.5
19.5 150
[0.41]
[0.77] [5.91]
±
0.5
AIR FLOW
25
41
[0.98]
[1.61]
±
0.5
12.5 150
190 5max
[0.2max]
[0.49] [5.91]
[7.48]
±
0.5
Name plate
20max
[0.79max]
4-M4
Mounting Hole
(Bottom side)
60
102
19.5
[0.77] [2.36]
[4.02]
±
0.5
Tolerance : ±1 [±0.04]
Weight
:
1.0kg max
PCB Material/thickness
:
CEM-3 / 1.6mm [0.06inches]
Chassis material
:
Aluminum
Case material : Electric galvanizing steel board
Dimensions in mm, [ ]=inches
Mounting torque
:
1.2N m max
Screw tightening torque : 1.6N m max
Connect the input FG to safety earth ground.
16.8 (LED)
[0.66]
±
1.5
16.6
[0.65]
±
1.5
13.1 (potentiometer)
[0.52]
±
1.5
PLA-14
PLA600F
AC-DC Power Supplies Enclosed Type
PL A 600 F -O -O
Ordering information
R
1 2 3 4 5 6
SPECIFICATIONS
MODEL PLA600F-12 PLA600F-15 PLA600F-24 PLA600F-36 PLA600F-48
INPUT
VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
*4
CURRENT[A]
ACIN 100V
6.7typ (Io=90%)
ACIN 115V
6.5typ (Io=100%)
ACIN 230V
3.2typ (Io=100%)
FREQUENCY[Hz] 50 / 60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
81typ (Io=90%) 81typ (Io=90%) 84typ (Io=90%) 85typ (Io=90%) 85typ (Io=90%)
ACIN 115V
81typ (Io=100%) 81typ (Io=100%) 84typ (Io=100%) 85typ (Io=100%) 85typ (Io=100%)
ACIN 230V
84typ (Io=100%) 84typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%)
POWER FACTOR
ACIN 100V
0.98typ (Io=90%)
ACIN 115V
0.98typ (Io=100%)
ACIN 230V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20/40typ (Io=90%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)
ACIN 115V
20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)
ACIN 230V
40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)
LEAKAGE CURRENT[mA] 1.5max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
OUTPUT
VOLTAGE[V] 12 15 24 36 48
CURRENT[A]
ACIN 85-115V
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V
50 40 25 16.7 12.5
WATTAGE[W]
ACIN 85-115V
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V
600 600 600 601.2 600
LINE REGULATION[mV]
*
8
48max 60max 96max 144max 192max
LOAD REGULATION[mV]
*
8
100max 120max 150max 150max 300max
RIPPLE[mVp-p]
*1
0 to +50C
120max 120max 120max 150max 150max
-20 to 0C
160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]
*1
0 to +50C
150max 150max 150max 200max 200max
-20 to 0C
180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
120max 150max 240max 360max 480max
-20 to +50C
180max 180max 290max 440max 600max
DRIFT[mV]
*
2
48max 60max 96max 144max 192max
START-UP TIME[ms] 300typ (ACIN 115V, Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80
OUTPUT VOLTAGE SETTING[V]
12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20
OPERATING INDICATION LED (Green)
REMOTE SENSING Optional (Option -W)
REMOTE ON/OFF Optional (Required external power source. Option -R)
ISOLATION
INPUT-OUTPUT RC
*
3
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
OUTPUT RC-FG
*
3
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
OUTPUT-RC
*
3
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*
5
-20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes
IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
HARMONIC ATTENUATOR
*
10
Complies with IEC61000-3-2 class A
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional
*7
C
: with Coating
G
: Low leakage current
V
:
External potentiometer for
output voltage adjustment
U : Low input voltage stop
(Complies with SEMI F-47)
W: Parallel operation,
LV alarm Remote sensing
R : Remote on/off
(Required external power source)
F4 :
Low speed fan
T2: Horizontal terminal block
(non-screw-hold type)
See 5.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
*Please consider “PJA600F-5” about 5V output.
Example recommended EMI/EMC filter
NAC-16-472
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
PLA-15
PLA600F
Features
*1 This is the result of measurement of the testing board with capacitors of
22mF and 0.1mF placed at 150 mm from the output terminals by a 20
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken
RM103.
See 1.6 of Instruction Manual for more details.
*2
Drift is the change in DC output for an eight hour period after a half-hour
warm-up at 25C.
*3
The RC terminal is added to option –R models. The RC terminal is
isolated from input, output, and FG.
*4
As for DC input, consult us for advice.
*5 Output power derating is required. See 3.2 in Instruction Manual.
*6 See 3.3 in Instruction Manual for more details.
*7
Consult us about safety agency approvals for the models with optional functions.
*8 Consult us about dynamic load and input response.
External view
Block diagram
FAN
External source
AC IN 85 - 264V
FG
RECTIFIER
OVER VOLTAGE
PROTECTION
THERMAL
PROTECTION
DETECTING
OUTPUT VOLTAGE
PARALLEL-OPERATION
CIRCUIT
CURRENT
SENSING
NOISE
FILTER
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
DC OUT
LV alarm (-W)
Current balance (-W)
RC (-R)
FUSE
250V 16A
INVERTER
CONTROL
CONTROL CONTROL
CONTROL
INVERTER
CURRENT
SENSING
RECTIFIER
AND
FILTER
BOOSTER
INDUCTOR
The external size of –V option, –W option, –R option, and –T2 option is different from the standard model. See “5. Options and Others”
in Instruction Manual for more details.
*9 The fan speed slows down at no load.
*10 Consult us about other classes.
*
Do not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be damaged.
*
Parallel operation is allowed for PLA600F models with the –W option only.
*
Sound noise may be heard from the power supply when used for pulse load.
OTHERS CASE SIZE/WEIGHT 120X61X215mm [4.72X2.40X8.46 inches] (Excluding terminal block and screw) (WXHXD) / 2.0kg max
COOLING METHOD
*
9
Forced cooling (internal fan)
WARRANTY WARRANTY
*
6
5 years (subject to the operating conditions)
SPECIFICATIONS
FG AC
(N) (L)
AC
(+V,-V)
Mounting Hole
LED
M4
AIR FLOW
4-M4
Name plate
V.ADJ
-V-V+V +V
4-M4
FG( )
(AC,FG)
M3.5
AC(L)
AC(N)
10.5
±1.5
18.5
±1.5
61
15.5 38
±
0.5
150
±
0.5
35
150
±
0.5
21max
3max
215
35
10 100
±
0.5
120
24.8
±1.5
79.25
±
1.5
10
108.1
7.412
15.5
±1.5
[0.41]
[0.73]
[0.98]
[0.29]
[0.47]
[0.39]
[0.39] [3.12]
[0.32]
[0.61]
[0.83max]
[1.38] [5.91]
[8.46]
[0.12max]
[0.39] [3.94]
[4.72]
[1.38] [5.91]
[1.5]
[2.4]
[0.61]
Tolerance : ±1 [±0.04]
Weight
:
2.0kg max
PCB Material/thickness
:
FR-4 / 1.6mm [0.06inches]
Chassis material
:
Electric galvanizing steel board
Case material
:
Electric galvanizing steel board
Dimensions in mm, [ ]=inches
Mounting torque
:
1.5N-m max
Screw tightening torque
:
M3.5 0.8N-m max
M4 1.6N-m max
Connect the input FG to safety earth ground.
Mounting Hole
(Bottom sides)
Output
terminal cover
Output terminal (-)
Output terminal (+)
Output voltage
adjustable potentiometer
15.8
±
1.5
(LED)
12.1
±
1.5
(potentiometer)
16.6
±
1.5
26.6
±
1.5
[0.62]
[1.05]
[0.65]
[0.48]
-
Cost-effective
-
Longer life (see Instruction Manual)
-
Low profile (meets 2U height = 61 mm or 2.40 inches)
-
Wide operating temperature range (-20 to +70 see
instruction manual)
-
Screw hold type terminal block
-
Slow fan speed at no load
-
Many optional functions
-
Complies with SEMI F-47 (-U option, see Instruction
Manual for details)