GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz MASWSS0201
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V1
1
RoHS
Compliant
Features
Ideal for CATV, DTV, DVR, STB Applications
Default-On in Unpowered State (RFC-RF1 Path)
Broadband Performance: DC-2.5 G Hz
Low Insertion Loss: 1.1 dB at 1 GHz
High Isolation: > 60dB @ 100MHz
Single Control Operation
Power Handling: > 20 dBm P1dB
Lead-Free 3 mm 12-lead PQFN Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
RoHS* Compliant and 260°C Reflow Compatible
Configurable for Non-termi nated Operation
Description
M/A-COM’s MASWSS0201 is a broadband GaAs
PHEMT MMIC SPDT terminated switch in a low
cost, lead-free 3 mm 12-lead PQFN package. The
MASWSS0201 is ideally suited for applications
where an unpowered on state is critical in a single
control line SPDT terminated switch. The
unpowered condition is the same as the VC = 0
condition. This part can also be configured as a
reflective switch with minimal impact to the RF
performance.
The MASWSS0201 delivers high isolation, low
insertion loss and high line arity up to 2.5 GHz.
The MASWSS0201 is fabricated using a 0.5 micron
gate length GaAs E/D PHEMT process. The
process features full passivation for performance
and reliability.
Ordering Information 1
Part Number Package
MASWSS0201TR-3000 3000 piece reel
MASWSS0201SMB Sample Test Board
(Includes 5 Samples)
1. Reference Application Note M513 for reel size information.
Pin No. Pin Name Description
1 N/C No Connection
2 RF1 RF Port 1
3 Term 1 GND3 Termination 1 Ground
4 GND Ground
5 N/C No Connection
6 GND Ground
7 Term 2 GND3 Termination 2 Ground
8 RF2 RF Port 2
9 VC Control
10 GND Ground
11 RFC RF Input
12 GND Ground
13 Paddle 4 RF and DC Ground
Pin Configuration 2
2. M/A-COM recommends that all unused (N/C) pins be
connected to ground. All data on this datasheet was taken
with N/C pins connected to ground.
3. Terminated grounds require DC blocking capacitors; see
application schematic.
4. The exposed pad centered on the package bottom must be
connected to RF and DC ground.
Functional Schematic
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz MASWSS0201
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V1
2
RoHS
Compliant
Electrical Specifications: TA = 25°C, Z0 = 75 Ω, VC = 0 V/3 V, PIN = 0 dBm 5
Parameter Test Conditions Units Min. Typ. Max.
Insertion Loss RFC to RF1
(VC = 0V)
100 MHz
1.0 GHz
2.0 GHz
dB
dB
dB
0.9
1.0
1.3
1.75
1.85
Isolation
100 MHz
1.0 GHz
2.0 GHz (RFC - RF1)
2.0 GHz (RFC - RF2)
dB
dB
dB
dB
60
40
65
45
38
43
Return Loss DC - 2.0 GHz dB 25
IIP2
(VC = 0V / 3V / 5V)
Two Tone, +5 dBm/Tone, 10 MHz Spacing
100 MHz
1.0 GHz
dBm
dBm
54 / 51 / 53
72 / 70 / 70
IIP3
(VC = 0V / 3V / 5V)
Two Tone, +5 dBm/Tone, 10 MHz Spacing
100 MHz
1.0 GHz
dBm
dBm
38 / 38 / 39
41 / 44 / 44
Input P1dB
(VC = 0V / 3V / 5V) 100 MHz
1.0 GHz dBm
dBm
21 / 21 / 22
29 / 28 / 29
T-rise
T-fall 10% to 90% RF
90% to 10% RF µS
nS
1.4
12
Ton
Toff 50% control to 90% RF
50% control to 10% RF µS
nS
1.6
12
Transients mV 550
Control Current VC = 3V µA 250 500
Insertion Loss RFC to RF2
(VC = 3V)
100 MHz
1.0 GHz
2.0 GHz
dB
dB
dB
1.0
1.2
1.5
1.65
1.85
Absolute Maximum Ratings 6,7
Parameter Absolute Maximum
Input Power @ 100 MHz +22 dBm
Input Power @ 1 GHz +29 dBm
Operating Voltage +8.5 volts
Operating Temperature -40°C to +85°C
Storage Temperature -65°C to +150°C
6. Exceeding any one or combination of these limits may cause
permanent damage to this device.
7. M/A-COM does not recommend sustained operation near
these survivability limits.
5. Electrical specifications apply to terminated configuration only.
Control
V
C
RFC-RF1 RFC-RF2
0 On Off
1 Off On
Truth Table 8,9,10
8. External DC blocking capacitors are required on all RF ports.
9. 0 = 0 ± 0.1 V, 1 = +2.9 V to +5 V.
10. The unpowered on state is the same as VC=0.
GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz MASWSS0201
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V1
3
RoHS
Compliant
Typical Performance Curves: TA = 25°C, Z0 = 75 Ω, Components per Application Schematic
Insertion Loss
Isolation (Below 200 MHz)
Isolation (Above 200 MHz)
RFC Return Loss
RF1 Return Loss
RF2 Return Loss
-3.0
-2.5
-2.0
-1.5
-1.0
-0.5
0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
RFC to RF1 (V c =0V)
RFC to RF2 (V c =3V)
Frequency (GHz)
-90
-80
-70
-60
-50
-40
25 50 75 100 125 150 175 200 225 250
RF C to RF 1 (Vc = 3V )
RF C to RF 2 (Vc = 0V )
Frequency (MHz)
-70
-60
-50
-40
-30
-20
RFC to RF1 ( V c= 3V)
RFC to RF2 ( V c= 0V)
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Frequency (GHz)
-50
-40
-30
-20
-10
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
RF C to RF1 ( V c = 0V )
RF C to RF2 ( V c = 3V )
Frequency (GHz)
-50
-40
-30
-20
-10
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
RF 1 to RFC ( V c = 0V )
RF 1 Terminate d (Vc = 3V )
Frequency (GHz)
-50
-40
-30
-20
-10
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
RF 2 to RFC ( V c =3V )
RF2 Terminated (Vc=0V)
Frequency (GHz)
GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz MASWSS0201
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V1
4
RoHS
Compliant
Lead-Free 3 mm 12-lead PQFN
C1-C5=10000 pf
C6=100 pf
Application Schematic 11,12
11. Non-connected pins (P1 and P5) are shown connected to
ground as recommended. All data on this datasheet was
taken with N/C pins connected to ground.
12. Application schematic shown is for terminated
configuration. For non-terminated operation Term 1 and
Term 2 ground pins are left open. See application section
for data in unterminated configuration.
Qualification
Qualified to M/A-COM specification REL-201,
Process Flow –2.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
M/A-COM’s AN3007 Application Note outlines a
method for ESD sensitivity mitigation. It can be
found at the Tech/Apps section of the
MACOM.COM website.
Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz MASWSS0201
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V1
5
RoHS
Compliant
Typical Performance Curves:
TA = 25°C, Z0 = 75 Ω, Unterminated Configuration (Term 1&2 GND pins open)
Insertion Loss
Isolation (Below 200 MHz)
Isolation (Above 200 MHz)
RFC Return Loss
RF1 Return Loss
RF2 Return Loss
Application Section
-3.0
-2.5
-2.0
-1.5
-1.0
-0.5
0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
RFC to RF1 (Vc =0V )
RFC to RF2 (Vc =3V )
Frequency (GHz)
-90
-80
-70
-60
-50
-40
25 50 75 100 125 150 175 200 225 250
RFC to RF1 (Vc =3V )
RFC to RF2 (Vc =0V )
Frequency (MHz)
-70
-60
-50
-40
-30
-20
RF C to RF 1 ( V c = 3V )
RF C to RF 2 ( V c = 0V )
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Frequency (GHz)
-50
-40
-30
-20
-10
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
RF C to RF1 ( V c = 0 V )
RF C to RF2 ( V c = 3 V )
Frequency (GHz)
-50
-40
-30
-20
-10
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
RF1 to RFC (V c =0V)
RF1 Unter m inated (Vc =3V)
Frequency (GHz)
-50
-40
-30
-20
-10
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
RF2 t o RF C (V c =3V )
RF 2 Unte r m in ated (Vc =0V)
Frequency (GHz)
GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz MASWSS0201
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V1
6
RoHS
Compliant
Application Section
Application Schematic –
Unterminated Configuration
C1-C3 = 10000 pf
C4 = 100 pf