01/16/13
Reduced RFI and EMI
Reduced Snubbing
• Extensive Characterization of Recovery Parameters
• Hermetic
Electrically Isolated
Ceramic Eyelets
Features
Description
These Ultrafast, soft recovery diodes are optimized to reduce losses and EMI/RFI in high frequency power
conditioning systems. An extensive characterization of the recovery behavior for different values of current,
temperature and di/dt simplifies the calculations of losses in the operating conditions. The softness of the recovery
eliminates the need for a snubber in most applications. These devices are ideally suited for power converters, motors
drives and other applications where switching losses are significant portion of the total losses.
Ultrafast, Soft Recovery Diode
FRED
VR = 600V
VF = 1.9V
Qrr = 270nC
di(rec)M/dt = 345A/µs
Note: D.C. = 50% rect. wave
1/2 sine wave, 60 Hz , P.W. = 8.33 ms
HFA35HB60C
www.irf.com 1
Parameter Max. Units
VRCathode to Anode Voltage (Per Leg) 600 V
IF(AV) Continuous Forward Current, TC =100 °C 30
IFSM Single Pulse Forward Current, TC = 25°C (Per Leg) 150
PD @ TC = 25°C Maximum Power Dissipation 63 W
TJ, TSTG Operating Junction and Storage Temperature Range -55 to +150 °C
A
Absolute Maximum Ratings
CASE STYLE
TO-254AA
(ISOLATED BASE)
ANODE COMMON ANODE
CATHODE
ESD Rating: Class 3B per MIL-STD-750, Method 1020
PD-20378C
2www.irf.com
HFA35HB60C
Electrical Characteristics (Per Leg)@ TJ = 25°C (unless otherwise specified)
Thermal - Mechanical Characteristics
Parameter Typ. Max. Units
RthJC Junction-to-Case, Single Leg Conducting 2.0
Wt Weight 9.3 g
°C/W
Dynamic Recovery Characteristics (Per Leg) @ TJ = 25°C (unless otherwise specified)
A/µs
nC
A
Parameter Min. Typ. Max. Units Test Conditions
trr1 Reverse Recovery Time 54 88 ns TJ = 25°C See Fig.
trr2 94 140 TJ = 125°C 5 IF = 15A
IRRM1 Peak Recovery Current 5.6 7.8 TJ = 25°C See Fig.
IRRM2 7.8 11.7 TJ = 125°C 6 VR = 200V
Qrr1 Reverse Recovery Charge 180 270 TJ = 25°C See Fig.
Qrr2 435 650 TJ = 125°C 7 dif/dt = 200A/µs
di(rec)M/dt1 Peak Rate of Fall of Recovery Current 300 345 TJ = 25°C See Fig.
di(rec)M/dt2 During tb 190 285 TJ = 125°C 8
See Fig. 2
Parameter Min. Typ. Max. Units Test Conditions
VBR Cathode Anode Breakdown Voltage 600 V IR = 250µA
LSSeries Inductance 8.7 nH Measured from anode lead to cathode
lead, 6mm ( 0.025 in. ) from package
CTJunction Capacitance, See Fig. 3 24 36 pF VR = 200V
IRReverse Leakage Current 10 µA VR = VR Rated
See Fig. 2 1.0 mA VR = 480V, TJ = 125°C
VFForward Voltage 1.7 IF = 15A, TJ = -55°C
See Fig. 1 1.9 IF = 15A, TJ = 25°C
— — 2.3 IF = 30A, TJ = 25°C
— 2.1 IF = 15A, TJ = 125°C
V
www.irf.com 3
HFA35HB60C
Fig. 4 - Maximum Thermal Impedance Zthjc Characteristics (Per Leg)
Fig. 2 - Typical Reverse Current Vs. Reverse
Voltage (Per Leg)
Fig. 3 - Typical Junction Capacitance Vs.
Reverse Voltage (Per Leg)
Fig. 1 - Maximum Forward Voltage Drop Vs.
Instantaneous Forward Current (Per Leg)
0.0001
0.001
0.01
0.1
1
10
100
1000
0 200 400 600
R
R
Reverse Voltage - V (V)
Reverse Current - I (µA)
T = 25°C
J
T = 125°C
J
T = 150°C
J
10
100
1000
1 10 100 1000
T = 25°C
J
Reverse Voltage - V (V)
R
T
Junction Capacitance - C (pF)
A
0.01
0.1
1
10
0.00001 0.0001 0.001 0.01 0.1 1
Notes:
1. Duty factor D = t / t
2. Peak T = P x Z + T
1 2
JDM thJC C
P
t
t
DM
1
2
t , Rectangular Pulse Duration (sec)
Thermal Response (Z )
1
thJC
0.01
0.02
0.05
0.10
0.20
D = 0.50
SINGLE PULSE
(THERMAL RESPONSE)
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Forward Voltage Drop - V F (V)
1
10
100
Instantaneous Forward Current - IF (A)
Tj = -55°C
Tj = 125°C
Tj = 25°C
4www.irf.com
HFA35HB60C
Fig. 7 - Typical Stored Charge Vs. dif/dt (Per Leg) Fig. 8 - Typical di(rec)M/dt Vs. dif/dt (Per Leg)
Fig. 5 - Typical Reverse Recovery Vs. dif/dt (Per Leg) Fig. 6 - Typical Recovery Current Vs. dif/dt (Per Leg)
0
30
60
90
120
150
100 1000
f
di /dt - (A/µs)
RR
Q - (nC)
I = 30A
I = 15A
I = 7.5A
F
F
F
V = 200V
T = 12C
T = 25°C
R
J
J
1
10
100
100 1000
f
di /dt - (A/µs)
I - (A)
IRRM
I = 30A
I = 15A
I = 7.5A
F
F
F
V = 200V
T = 125°C
T = 25°C
R
J
J
0
300
600
900
1200
100 1000
f
di /dt - (A/µs)
RR
Q - (nC)
I = 30A
I = 15A
I = 7.5A
F
F
F
V = 200V
T = 125°C
T = 25°C
R
J
J
10
100
1000
10000
100 1000
f
di /dt - (A/µs)
di(rec)M/dt - (A/µs)
I = 15A
F
I = 7.5A
I = 30A
F
F
V = 200V
T = 125°C
T = 25°C
R
J
J
www.irf.com 5
HFA35HB60C
4. Qrr - Area under curve defined by trr
and IRRM
trr X IRRM
Qrr =
2
5. di(rec)M/dt - Peak rate of change of
current during tb portion of trr
Fig. 10 - Reverse Recovery Waveform and Definitions
Fig. 9 - Reverse Recovery Parameter Test Circuit
t
a
t
b
t
rr
Q
rr
I
F
I
RRM
I
RRM
0.5
di(rec)M/dt
0.75 I
RRM
5
4
3
2
0
1
di /dt
f
1. dif/dt - Rate of change of current
through zero crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured
from zero crossing point of negative
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
REVERSE RECOVERY CIRCUIT
IRFP250
D.U.T.
L = 70µH
V = 200V
R
0.01
G
D
S
dif/dt
ADJUST
Case Outline and Dimensions — TO-254AA
PIN AS S IGNMENT S
1 = ANODE 1
2 = COMMON CATHODE
3 = ANODE 2
NOT E S :
1. DIME NS IONING & TOLERANCING PER ASME Y14.5M-1994.
2. ALL DIMENSIONS ARE SHOWN IN MILLIMETERS [INCHES].
3. CONTROLL ING DIMENS ION: INCH.
4. CONFORMS T O JE DE C OUT LINE T O-254AA.
IR WORLD HEADQUARTERS: 101 N. Sepulveda Blvd., California 90245, USA Tel: (310) 252-7105
IR LEOMINSTER : 205 Crawford St., Leominster, Massachusetts 01453, USA Tel: (978) 534-5776
TAC Fax: (310) 252-7903
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 01/2013
3.81 [.150]
0.12 [.005]
1.27 [.050]
1.02 [.040]
6.60 [.260]
6.32 [.249]
C14.48 [.570]
12.95 [.510]
3X
0.36 [.014] B A
1.14 [.045]
0.89 [.035]
2X
3.81 [.150]
20.32 [.800]
20.07 [.790]
13.84 [.545]
13.59 [.535]
3.78 [.149]
3.53 [.139]
17.40 [.685]
16.89 [.665]
A
123
13.84 [.545]
13.59 [.535]
0.84 [.033]
MAX.
B