Programmable Terminals NT11/ NT21 Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. This catalog mainly provides information that is necessary for selecting suitable models, and does not contain precautions for correct use. Always read the precautions and other required information provided in product operation manuals before using the product. The application examples provided in this catalog are for reference only. Check functions and safety of the equipment before use. Never use the products for any application requiring special safety requirements, such as nuclear energy control systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, or other application involving serious risk to life or property, without ensuring that the system as a whole has been designed to address the risks, and that the OMRON products are properly rated and installed for the intended use within the overall equipment or system. NT11 NT21 Note: Do not use this document to operate the Unit. OMRON Corporation Regional Headquarters FA Systems Division H.Q. 66 Matsumoto Mishima-city, Shizuoka 411-8511 Japan Tel: (81)55-977-9181 Fax: (81)55-977-9045 OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 Authorized Distributor: OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)847-843-7900/Fax: (1)847-843-8568 OMRON ASIA PACIFIC PTE. LTD. 83 Clemenceau Avenue, #11-01, UE Square, Singapore 239920 Tel: (65)6835-3011/Fax: (65)6835-2711 Note: Specifications subject to change without notice. Cat. No. V071-E1-02 Printed in Japan 1003-0.5M Compact Size, High Performance NT11 NT Superb functionality with a compact screen size Effective display area 117 x 63 mm High-speed NT Links Two RS-232C ports Memory Link Printout of Production Status Bar Graphs can be Displayed Data such as the production status and production results can be printed out, leaving a record on paper which can be used as a daily report. (The NT11S has a printer port. One screen only is printed.) Bar graph displays allow the progress of processes to be checked at a glance. (The bars are oriented horizontally.) Supports Memory Units Up to 3,999 screens Concentrated functionality Mathematical functions 31 functional parts * Recipes * Alarm lists/histories * Image library * Trend graphs * Analog meters NT20S/NT31 data compatibility Screen Line 1 Line 2 Line 3 Prod. 200 140 350 Plan 200 150 350 Advantages From the Standpoint of Maintenance, Password Screens for Security Upgraded NT Support Tool version (-EV4.7) * Shares I/O comment data with CX-Programmer * Symbol Manager previews * Copy image library window data * Individual editing of grouped parts * Windows XP supported NT21 Supports RS-232C/422 Adapter (connector) Bar Code Reader function Programming Console function Integral Numeric Key Pad The display, numeric keys, and function keys are all integrated into the front panel, which is convenient for designers. The key layout is ergonomically designed for ease of use. Password screens cannot be accessed unless the correct password is entered. This means that the operations that can be performed can be restricted according to the operator. High-speed Host Link Up to 115,200 bps supported between CS1/CJ1 PLCs. High-speed Host Link Key Titles can be Marked on the Function Key Sheet Long-lived Backlight Key titles can be marked on the function key sheet in accordance with the applications of the keys: the sheet can be taken out from the side face of the terminal. The front panel of the terminal has a water-withstanding construction. Fully Compatible with NT11S Full Area Access to CS1/CJ1 Since LEDs are used for the backlight, it is very long-lived and rarely needs to be changed. Display History Record Helps in Analysis of Machine Faults When the display history record function is set as a screen attribute, the time, the screen number, and a comment are recorded in the terminal's memory every time the relevant screen is displayed. This display history can be printed by issuing a print instruction from the host, and is useful for machine fault analysis. Example key titles: F1 F2 RUN AUT Long-lived Backlight F3 MAN. Example printout F4 STOP NT11 Password Screens No. Time Screen No Screen Comment 1 11/01-10:00 1 LINE ERROR 2 11/07-15:33 15 MOTOR ERROR 3 11/11-13:56 19 COMPRESSER ERROR 4 11/14-09:12 5 MOTOR ERROR Simplified Ladder Programming Conforms to NEMA4 and IP65 2 3 NT21 NT2 Versatile I/O and Large-capacity Screen Memory in a Space-saving Size Highly Reliable Hardware Upgraded NT Support Tool Version (EV4.7) Small Size, Large Screen Long, Maintenance-Free Life (50,000 h) Enhanced Editing Functions The LCD screen is larger than the OMRON NT20S (increased from 256 x 128 dots to 260 x 140 dots), but the external dimensions and panel cut-out size are the same. Conforms to International Standards *I/O comments in the I/O tables of the CX-Programmer can be used directly. Larger screen The NT21 conforms to the EC Directives, as well as UL, cULus (Class 1 Div2), and C-Tick. The front panel has an enclosure rating equivalent to IP65F. NT Support Tool CX-Programmer CX-Server I/O comment data System and screen data can be stored in NT21 Flash Memory. I/O comments for designated PLC addresses can be used directly, with no need for CSV file conversion. Function Support Equivalent to That of a Mid-size Operator Interface Two RS-232C Ports Two RS-232C ports in the NT21 (compared with one in the NT20S) enable simultaneous connection of a PLC, Bar Code Reader, and NT Support Tool (connectable to serial port A only). NT21 NT Support Tool (screen creation/transfer) RS-232C RS-232C PLC (host) Plenty of Capacity for Saving Graphic Screens With 512 Kbytes of memory capacity, there is more than ample space for storing screen data. Abundant graphic screen storage Versatile Communications NT21 NT21 High-speed 1:N NT Links 4 Memory Link *Windows XP supported. Comparison with the NT11 Basic performance Alarm List/History(*) Model Dimensions NT11 NT11S 218 x 113 x 38.2 mm (H x W x D) Resolution 160 x 64 dots (4.24 inches) 100 x 40 mm Effective display area Display color An alarm message can be displayed in response to PLC bit status, and the content and time of the message can be stored as an alarm history. Max. number of registered screens 250 Screen data capacity *C500-BAT08 Battery (sold separately) required. Other Keys Display elements Programming Console Function The NT21 is equipped with many of the same functions as the SYSMAC PLC Programming Console. Programming Console function Special functions PLC (host) 32 KB 4 Numeric Keys, Cursor Keys, Function Keys Personal computer (host) Up to 256 math equations can be stored in the PT processing table to allow automatic PT processing, and the results can be written to the numeral memory table or other destinations. This makes it possible to perform scaling and other mathematical operations automatically in the PT. 117 x 63 mm 112 x 56 mm Black & white (with blue mode) 178.5 x 100.5 mm 3,999 500 512 KB 96 KB None None None None None Supported None Painting out None Supported None Image/library displays None 256 positions per screen None Analog meters None 50 positions per screen None Trend graphs None 1 position per screen None Broken line graphs None 1 position per screen None Alarm lists/histories None 4 positions per screen None Recipes None 1 position per screen None Interlocks None Supported None Mathematical Function None Math equations: Max. 256 (arithmetic functions, logic operations, bit manipulations, comparison operations) None Programming Console function None (Executes functions equivalent to C200H-PR027 and CS1 Programming Consoles.) None Supported None Supported None 50,000 hours min. 10,000 hours min. None Supported Via RS-232C communications None Supported None 9,600/19,200 9,600/19,200 High-quality font Backlight service life Communications 256 x 128 dots (4.91 inches) Rectangles, polygons, arcs, sectors RS-232C Mathematical Functions 260 x 140 dots (5.2 inches) 204.2 x 99.8 mm Panel cut-out size (W x H) Function keys NT21 NT20S 190 x 110 x 53.5 mm (H x W x D) Black & white (with Yellow mode) None None (Emergency transfer mode)* Memory Unit RS-232C PLC (host) Note: Some data revisions may be required due to size differences. Parts tables on the PT screen can be used to set multiple word data in records, which can then be written to the PLC by a simple PT touch panel operation. For example, the setting parameters for separate models can be edited on the PT, then written to or read from the PLC. NT21 In addition to the Host Link and 1:1 NT Link communications, the NT21 supports high-speed 1:N NT Links and Memory Link communications. RS-232C Recipe Function *Symbol Manager previews are supported. This function makes it possible to preview symbols (parts created from graphics data). *Parts can be copied by drag & drop operations of image, library, or mark data. *The properties of grouped parts can be edited without having to ungroup them. *Because NT20S and NT31 screen data is compatible with the NT21, existing software assets can be utilized to greatly reduce the number of design steps. 50,000 hours min. Memory Links Bar Code Reader connection Host Link Speed Up to 115,200 10,000 hours min. 9,600/19,200 *Emergency transfer mode: When power to the NT11 is turned ON with DIP switch pin 3 turned ON, data transfer mode can be entered directly without any other operation. 5 NT21 NT2 NT11 NT NT11 General Specifications Item Special Features Specification 24 VDC Specification Printing function Allowable power Item Printing of display history data Printing of daily reports (printing format registered by the users) Conforms to IEC61000-4-4, 2K (power lines) Vibration resistance 10 to 57 Hz with 0.075 mm amplitude and 57 to 150 Hz with 9.8 m/s2 acceleration for 30 min in each of X, Y, and Z directions Shock resistance 147 m/s 3 times in each of X, Y, and Z directions Product Ambient operating temperature 0 to +50C Ambient operating humidity 35 to 85% RH (with no condensation) Terminal* Specification Host link direct connection, NT link method Support Software Operating environment No corrosive gasses. Storage temperature -20 to +70C (with no freezing) Enclosure ratings Front panel: Equivalent to IP65, NEMA4 Weight 1.0 kg max. Shock resistance NT11 Product Configurations 2 Function key sheet * Power consumption Conforms to IEC61000-4-4. Power supply line: 2 kV 2 Vibration resistance * Simple communications confirmation. Model Ten-key type (frame color: beige) NT11-SF121-EV1 Ten-key type (frame color: black) NT11-SF121B-EV1 CD-ROM (for Windows 95, 98, Me, XP, NT, 2000) NT-ZJCAT1-EV4 10 sheets for replacement for beige NT11-CKF01 10 sheets for replacement for black NT11-CKF01B Item Specification 15% Noise resistance Maintenance functions Noise resistance Display Specifications NT21 General Specifications Item acceleration, Peak acceleration 15 G, Ambient operating temperature Ambient operating humidity C) Enclosure ratings Front panel operating section: Equivalent to IP65F, NEMA 4.* Weight 0.6 kg max. *Connecting cables with the PLC and NTST are the same as those for the NT21. Please refer to the next page. Display/Panel Specifications Note: In order to improve the performance of displays, liquid crystal devices may be ch Item Dot matrix of STN liquid Display screen * Number of dots: 160 x 64 * Effective display area: 100 x 40 mm * Life expectancy: 50,000 hours minimum * View angle (left/right direction): 20 Indicators * RUN indicator (Green LED): Lit during operation Switch * Life expectancy: 1 million operations minimum 203 Graphics Number of characters displayed Display elements Numeral screen Menu screen Can be set to turn OFF in 1 to 255 min or to remain ON with screen saver Service life Specification Number of switches 91 (13 horizontally x 7 vertically) Input Pressure-sensitive 1 N max. Communications method Not supported Host Link Supported Supported 1:1 NT Link Supported Supported 1:N NT Links Supported Supported NT Link, PT Programming Console function Supported Supported Supported Supported Supported Not supported Bar Code Reader Trend graphs One frame per screen, 50 items per frame (8 items max. for data logging) 256 positions per screen Image library images 256 positions per screen 26 positions per screen Memory Links *Connection via RS-422A/485 is possible using the NS-AL002 RS-232C/422A Adapter (connector), which can be connected only to serial port B. (RS-485 connections must use 1:N NT Links.) NT21 Standard Models Product Total of 256 positions for both numerical and thumbwheel settings Specification Panel Plate thickness: 1.6 to 4.8 mm Recommended panel cutout: 8 positions per screen Frame color: beige NT21-ST121-E Support Tooll Windows 95, 98, Me, NT, or 2000 CD-ROM NT-ZJCAT1-EV4 For screen transfer Cables Recipes One position per screen Normal screens Displays screens registered as normal For PLC connection XW2Z-S002 PT: 9-pin PLC: 9-pin Cable length: 2 m XW2Z-200T PT: 9-pin PLC: 25-pin Cable length: 2 m XW2Z-200S Cable length: 5 m XW2Z-500S Cable length: 5 m XW2Z-500T-2 PT: 9-pin PLC: Mini-peripheral A maximum of eight screens can be displayed overlapping each other. 8 positions per screen 4 positions per screen Order of frequency, 256 screens Ensures security: screens for which this attribute is set can only be displayed if the correct password is input. 204.2 +0.5 0 Screen Windows Display history screens types Programming Console screen Emulates PLC Programming Console functions, capable of being called from RUN mode. Screen attributes Four items per screen Screen types Normal screen: Displays screen registered as normal. Max. number of registered screens 250 Screen registration method Transfer screen data created using an IBM PC/AT personal computer to the PT. Screen saving method Saved to flash memory: 32 KB (downloading method) Order of occurrence (1,024 screens max.), order of frequency (255 times max.) Displayed when powering ON (or resetting ) the PT, and when switching to RUN mode. Max. number of Rear face Up to three window screens can be displayed. System startup screen Number of screens Screen number Screen registration method 80.5 Saving screen data Options Reflection Protective Sheets Display area only (5 sheets) NT20M-KBA04 Chemical-resistive Cover Silicon cover NT20S-KBA01 Battery For alarm lists/histories For screen and system data transfer C500-BAT08 Memory Unit Buzzer, display history, normal background colors, backlight mode, local windows NT-MF161 RS-232C/422A Adapter NS-AL002 Connector Kit XM2S-0911-S003 Dimensions 3,999 0: No display 1 to 3999: User registered screens (normal, overlapping, windows) 9000: System startup screen 9001: Display history screens, order of occurrence 9002: Display history screens, order of frequency 9020: Programming Console screen 9999: Model number NT21 Programmable Monochrome STN Terminal 256 positions per screen Normal-size: 20 horizontally x 4 lines vertically max. Serial port B Supported 50 positions per screen, capable of displaying signs and percentages Lamps Serial port A NT Support Tool Analog meters One frame per screen, 256 items per frame, 260 points per item 1 million operations min. External Interface Specifications SBC/personal computer 38.2 50,000 hours min. (at room temperature, until brightness is reduced to 50%) Replacement Non-replaceable 50 positions per screen, capable of displaying signs and percentages 256 positions per screen Numeral settings Screen attributes history 50,000 hours min. (until contrast reduced to 50%) Automatic turn-OFF Graph displays 218 98.8 +0.5 0 Graph rectangles, circles, Touch switches Normal characters (8 x 16 dots): Alphanumerics and symbols Marks (8 x 16 dots): User-defined, 64 max. Service life 256 positions per screen, max. 1,024 display elements for overlapping screens Display elements Broken line graphs Black & white (with blue mode) Character string displays Specification Double width Character string displays Touch panel PLC 98 Display color Item Marks Display Capacity Display characters With overlapping screens, the total is 524,280 per screen (Graphics: Note: In order to improve the performance of displays, liquid crystal devices may be changed without notice. Item Specification Fixed displays 113 3 117 mm horizontally x 63 mm vertically Viewing angle Life expectancy Item Backlight * LED * Life expectancy: 50,000 hours minimum * Automatic turn-off: can be set to turn off in 10 minutes or 1 hour, or to remain on. 260 dots horizontally x 140 dots vertically Effective display area Backlight (white cold cathode tube) Display Capacity Outside Dimensions Specification Number of dots (resolution) Panel Specifications 190 x 110 x 53.5 mm (W x H x D) (thickness inside panel: 49.0 mm) *Usage may not be possible in places where the unit would be exposed to oil for long periods. and a flash ROM that downloads the system program. Monochrome STN LCD - Dimensions Display panel Specification Display device 178 100 122 53.5 4.5 Return to previous screen designation By transferring screen data from the NT Support Tool to the PT via serial communications 39 min. 110 By mounting the Memory Unit and downloading (automatic/manual transfer) data to the PT Flash memory (PT internal image memory) 15.5 28 142 190 Panel thickness: 1.6 to 4.8 mm 178.5 +0.5/- x 100.5 6 /-0 mm (W x H) 19.5 52.5 Cat. No. V071-E1-02 OMRON Corporation 2007. 3 In the interest of product improvement, specifications are subject to change without notice. Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: NT21-ST121-E NT21-ST121B-E