TA45-2R Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Circuit Breaker for Equipment thermal, 2 pole, Rocker actuation See below: Approvals and Compliances Description -Thermal circuit breaker -1 or 2 pole thermal overload protection -Positively trip-free release -High configurability -Rocker non-illuminated or illuminated -Snap-in version -Quick connect terminal 6.3 x 0.8 mm or screw clamp terminal M3.5 x 6 mm (lineside P1, P2) Technical Data Applications -Power tools -Industrial appliances -Power supplies Weblinks pdf data sheet, html datasheet, General Product Information, DistributorStock-Check, Detailed request for product, Product News Rated Voltage AC Rated Voltage DC Rated current range AC Conditional short circuit capacity Inc Degreeof Protection Dielectric Strength Insulation Resistance Lifetime 240 VAC 60VDC 0.05-20A IEC: Inc, PC1, AC 240 V: 1 kA from front sideIP40acc. toIEC 60529 4kVAC 500VDC>100M mechanical: 50'000switching cycles AC: 1 x Ir: 50'000switching cycles DC: 1 x Ir: 50'000switching cycles Overload Allowable Operation Temp. Vibration Resistance Shock Resistance Tripping Type Actuation Type Weight AC: min. 40trips @ 6 x Ir DC: min. 40trips @ 4 x Ir -10C to 55C 0.75 mm @ 5 - 60 Hz acc. to IEC 60068-2-6, test Fc 10 G @ 60 - 500 Hz acc. to IEC 60068-2-6, test Fc 30 G / 18ms acc. to IEC 60068-2-27, test Ea Thermal Rocker 30-35g Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: TA45 Approval Logo Certificates Certification Body Description VDE Approvals VDE VDE Certificate Number: 40019880 UL Approvals UL UL File Number: E71572 CCC Approvals CCC CCC Certificate Number: 2013010307660082 Circuit Breakers 1 TA45-2R Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60934 Circuit-breakers for equipment (CBE) Designed according to UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment Designed according to CSA C22.2 No. 235 Supplementary Protectors Designed according to GB 17701 Circuit-breaker for equipment Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment. Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification Dimension [mm] Quick connect terminal Screw terminal 25 16 34 10.8 23.7 44.1 P1 a P1 a 3 3 5 5 10.6 5.3 26.7 B) 10.8 8.4 10.8 21.5 A) A) Quick connect terminal, IEC 61210, A6.3-0.8 mm B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm Accessories / factory mounted AZM01 / Collar with cover, IP54 AZM02 / Raised collar with cover, narrow, IP54 AZM03 / Raised collar, IP40 33.6 27.5 19.2 33.6 27.5 19.2 17.6 43.7 43.7 15.3 56.5 50.5 12.5 56.6 50.5 48 17.6 8.1 26.7 12.5 3.5 48 2 Circuit Breakers TA45-2R Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 AZM11 / Partially raised collar with cover, narrow, IP54 AZM12 / Partially raised collar without cover, narrow, IP40 AZM10 / Collar with cover, narrow, IP54 27 19.2 17.3 8.8 17.3 50 48 43.8 43.8 14 50 37.2 AZM13 / Raised collar narrow, IP40 50 AZM14 / Raised collar with cover narrow, IP54 27 27 19.2 14 10.6 10.6 33.2 33.2 14 17.3 50 Cut-out and pin-out Cut-out snap-in type a (1.0 - 5.0) 21.7 - 0.0 +0.2 Pin-out b 1) a b 1.0 1.5 2.0 2.5 3.0 4.0 5.0 44,5...45,0 44,5...45,0 44,7...45,2 44,7...45,2 44,8...45,3 44,9...45,4 45,0...45,5 U-Relais P2 P1 b a c 4 6 3 5 2) 1) Assemble 2) edge must be sharp Circuit Breakers 3 TA45-2R Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Diagrams 1 pole thermal overload protection 1 pole thermal overload protection, Shunt terminal P2 6 P2 P1 3 6 2 pole thermal overload protection 3 5 2 pole thermal overload protection, Shunt terminal P2 P1 4 3 6 Effect of ambient temperature The units are calibrated for an ambient temperature of +23C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: Ambient Temperature [C] Correction factor -10 0.89 -5 0.91 0 0.92 +23 1.00 +30 1.03 +40 1.08 +55 1.16 Example: Rated current = 5 A, Environmental temperature = 40 C, --> Correction factor = 1.08, Resulting current = 5.5 A --> Fount to next higher rated current: 6 A 4 P1 Circuit Breakers P2 P1 4 3 5 TA45-2R Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Time-Current-Curves [ min ] [ sec ] 10'000 Type TA45 Rated current In <3 A 60 30 20 2000 Ambient temp. 1000 10 [ min ] [ sec ] 10'000 1 pole protected 2 pole protected 30 +23C 20 10 500 5 2000 2 pole protected Ambient temp. 1000 +23C 500 100 Time in Seconds 1 50 20 10 1 50 20 10 5 5 2 2 1 1 0,5 0,5 0,3 0,3 0,2 0,2 0,1 0,1 1,05 1,32 2 3 4 5 8 10 1,05 1,32 Multiple of Rated Current In Multiple of Rated Current In Reference Temperature +23 Reference Temperature +23 [ min ] [ sec ] 10'000 Type 2 3 4 5 8 10 TA45 In > 18 A Rated current 60 20 3 A > In <18 A 1 pole protected 200 100 30 TA45 5 200 Time in Seconds Type Rated current 60 1 pole protected 2000 2 pole protected Ambient temp. 1000 10 +23C 500 5 Time in Seconds 200 100 1 50 20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10 Multiple of Rated Current In Reference Temperature +23 Config. Code TA45|-|AK2|W|F|120|A2|-|AZM11| The characters are placeholders for the correspondingly keys of selections from the key tables. TA45|-|AK2|W|F|120|A2|-|AZM11| = Basic function Circuit Breakers 5 TA45-2R Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Basic function Configuration key Basic function Configuration key 2-pole, rocker, 1pole overload protection, quick connect terminal, illuminated 220 V...240 V A12 2-pole, rocker, 2pole overload protection, screw connection, illuminated 4 V...7 V A89 2-pole, rocker, 1pole overload protection, quick connect terminal, illuminated 110 V...120 V A14 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, illuminated 220 V...240 V A92 2-pole, rocker, 1pole overload protection, quick connect terminal, illuminated 20 V...26 V A17 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, illuminated 110 V...120 V A94 2-pole, rocker, 1pole overload protection, quick connect terminal, illuminated 10 V...13 V A18 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, illuminated 20 V...26 V A97 2-pole, rocker, 1pole overload protection, quick connect terminal, illuminated 4 V...7 V A19 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, illuminated 10 V...13 V A98 2-pole, rocker, 1pole overload protection, shunt terminal, quick connect terminal, illuminated 220 V...240 V A22 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, illuminated 4 V...7 V A99 2-pole, rocker, 1pole overload protection, shunt terminal, quick connect terminal, illuminated 110 V...120 V A24 2-pole, rocker, 2pole overload protection, quick connect terminal, without illumination ABD 2-pole, rocker, 1pole overload protection, shunt terminal, quick connect terminal, illuminated 20 V...26 V A27 2-pole, rocker, 1pole overload protection, shunt terminal, quick connect terminal, without illumination ABF 2-pole, rocker, 1pole overload protection, shunt terminal, quick connect terminal, illuminated 10 V...13 V A28 2-pole, rocker, 2pole overload protection, shunt terminal, quick connect terminal, without illumination ABG 2-pole, rocker, 1pole overload protection, shunt terminal, quick connect terminal, illuminated 4 V...7 V A29 2-pole, rocker, 1pole overload protection, quick connect terminal, without illumination ABT 2-pole, rocker, 2pole overload protection, quick connect terminal, illuminated 220 V...240 V A32 2-pole, rocker, 2pole overload protection, quick connect terminal, momentary switch, without illumination AED 2-pole, rocker, 2pole overload protection, quick connect terminal, illuminated 110 V...120 V A34 2-pole, rocker, 1pole overload protection, shunt terminal, quick connect terminal, momentary switch, without illumination AEF 2-pole, rocker, 2pole overload protection,quick connect terminal, illuminated 20 V...26 V A37 2-pole, rocker, 2pole overload protection, shunt terminal, quick connect terminal, momentary switch, without illumination AEG 2-pole, rocker, 2pole overload protection, quick connect terminal, illuminated 10 V...13 V A38 2-pole, rocker, 1pole overload protection, quick connect terminal, momentary switch, without illumination AET 2-pole, rocker, 2pole overload protection, quick connect terminal, illuminated 4 V...7 V A39 2-pole, rocker, 2pole overload protection, screw connection, without illumination AHD 2-pole, rocker, 2pole overload protection, shunt terminal, quick connect terminal, illuminated 220 V...240 V A42 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, without illumination AHF 2-pole, rocker, 2pole overload protection, shunt terminal, quick connect terminal, illuminated 110 V...120 V A44 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, without illumination AHG 2-pole, rocker, 2pole overload protection, shunt terminal, quick connect terminal, illuminated 20 V...26 V A47 2-pole, rocker, 1pole overload protection, screw connection, without illumination AHT 2-pole, rocker, 2pole overload protection, shunt terminal, quick connect terminal, illuminated 10 V...13 V A48 2-pole, rocker, 2pole overload protection, screw connection, momentary switch, without illumination AJD 2-pole, rocker, 2pole overload protection, shunt terminal, quick connect terminal, illuminated 4 V...7 V A49 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, momentary switch, without illumination AJF 2-pole, rocker, 1pole overload protection, screw connection, illuminated 220 V...240 V A62 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, momentary switch, without illumination AJG 2-pole, rocker, 1pole overload protection, screw connection, illuminated 110 V...120 V A64 2-pole, rocker, 1pole overload protection, screw connection, momentary switch, without illumination AJT 2-pole, rocker, 1pole overload protection, screw connection, illuminated 20 V...26 V A67 2-pole, rocker, 1pole overload protection, screw connection, illuminated 10 V...13 V A68 2-pole, rocker, 1pole overload protection, screw connection, illuminated 4 V...7 V A69 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, illuminated 220 V...240 V A72 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, illuminated 110 V...120 V A74 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, illuminated 20 V...26 V A77 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, illuminated 10 V...13 V A78 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, illuminated 4 V...7 V A79 2-pole, rocker, 2pole overload protection, screw connection, illuminated 220 V...240 V A82 2-pole, rocker, 2pole overload protection, screw connection, illuminated 110 V...120 V A84 2-pole, rocker, 2pole overload protection, screw connection, illuminated 20 V...26 V A87 2-pole, rocker, 2pole overload protection, screw connection, illuminated 10 V...13 V A88 6 Circuit Breakers TA45|-|AK2|W|F|120|A2|-|AZM11| = Actuator colour Actuator colour Configuration key Clear transparent 1 Red transparent 3 Green transparent 4 Orange transparent 6 Black B Green G Red R White W Orange X Yellow Y TA45|-|AK2|W|F|120|A2|-|AZM11| = Legend TA45-2R Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 F 0 embossed Configuration key I Legend white printed OFF ON ON I black printed H K L 0 white printed OFF M 0 black printed I white printed I P 0 black printed I R 0 white printed ON I 0 OFF S black printed ON I 0 OFF T TA45|-|AK2|W|F|120|A2|-|AZM11| = Rated current Rated current Configuration key 0.05 A Z05 0.1 A J01 0.2 A J02 0.3 A J03 0.4 A J04 0.5 A J05 0.6 A J06 0.7 A J07 0.8 A J08 0.9 A J09 1.0 A J10 1.1 A J11 1.2 A J12 1.3 A J13 1.4 A J14 1.5 A J15 1.6 A J16 1.7 A J17 1.8 A J18 1.9 A 2.0 A 2.1 A Other rated currents on request J19 J20 J21 Rated current Configuration key 2.2 A J22 2.3 A J23 2.5 A J25 2.8 A J28 3.0 A 030 3.5 A 035 4.0 A 040 4.5 A 045 5.0 A 050 6.0 A 060 6.5 A 065 7.0 A 070 7.5 A 075 8.0 A 080 9.0 A 090 10.0 A 100 11.0 A 110 12.0 A 120 13.0 A 130 14.0 A 140 15.0 A 150 16.0 A 160 17.0 A 170 18.0 A 180 19.0 A 190 20.0 A 200 Other rated currents on request TA45|-|AK2|W|F|120|A2|-|AZM11| = Release / lock-out latch Release / lock-out latch Configuration key whithout release / lock-out latch C0 TA45|-|AK2|W|F|120|A2|-|AZM11| = Accessories Factory mounted accessories Configuration key Without cover Collar with cover, IP54 AZM01 Raised collar with cover, IP54 AZM02 Raised collar, IP40 AZM03 Raised collar with cover narrow, IP54 AZM10 Partially raised collar with cover, narrow, IP54 AZM11 Partially raised collarwithout cover, narrow, IP40 AZM12 Raised collar narrow, IP40 AZM13 Raised collar with cover narrow, IP54 AZM14 For subsequent fitting accessories see: https://www.schurter.com/pdf/english/typ_TA45-ACC.pdf Circuit Breakers 7 TA45-2R Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Variants Addition Thermal overload protection connection type Illumination Actuator colour Legend Rated current Accessories Config. Code Order Number 1-pole Quick connect terminal without illumination White embossed 10.0 A Without cover TA45-ABTWF100C0 4430.0022 2-pole Quick connect terminal without illumination Black white printed 15.0 A Without cover TA45-ABDBL150C0 4430.1089 2-pole Quick connect terminal without illumination Black white printed 15.0 A Without cover TA45-ABDBS150C0 4430.1328 Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging Unit 1Pcs Accessories Description TA45-ACC Accessories to TA45 16.11.2019 8 Circuit Breakers The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.