https://www.phoenixcontact.com/us/products/2864419 Loop-powered isolators-MINI MCR-SL-1CP-I-I-2864419 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) MCR loop-powered isolator, 1-channel, for the electrical isolation of current signals without auxiliary power, with screw connection Product Description The 6.2 mm narrow passive loop-powered isolator MINI MCR-SL-...CP-I-I... is used for the electrical isolation and filtering of 0...20 mA and 4...20 mA standard current signals without additional supply voltage. Your advantages Voltage drop at isolating amplifier of just 1.7 V Does not require additional auxiliary voltage Supplied by an input loop Two channels on a design width of just 6.2 mm Highly compact 2-conductor passive isolators for the electrical isolation and filtering of standard analog signals Key Commercial Data Packing unit 1 pc GTIN GTIN 4017918974848 Weight per Piece (excluding packing) 68.600 g Custom tariff number 85437090 Country of origin Germany Technical data Dimensions Width 6.2 mm Height 93.1 mm 01/17/2021Page1/7 https://www.phoenixcontact.com/us/products/2864419 Loop-powered isolators-MINI MCR-SL-1CP-I-I-2864419 Technical data Dimensions Depth 101.2 mm Ambient conditions Ambient temperature (operation) -20 C ... 65 C Ambient temperature (storage/transport) -40 C ... 85 C Maximum altitude 2000 m Permissible humidity (operation) 5 % ... 95 % (non-condensing) Degree of protection IP20 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Input data Description of the input Current input Number of inputs 1 Configurable/programmable no Current input signal 0 mA ... 20 mA 4 mA ... 20 mA max. input voltage 18 V Max. input current 40 mA Response current approx. 190 A Input voltage limitation < 2 V (20mA) Voltage dissipation 1.9 V (I = 20 mA) Output data Output name Current output Number of outputs 1 Configurable/programmable no Current output signal 0 mA ... 20 mA 4 mA ... 20 mA Load/output load current output < 600 (at I = 20 mA output signal) Ripple < 10 mVrms (at 600 ) Transmission Behavior 1:1 to input signal Power supply Supply voltage range no separate supply voltage necessary Power consumption 34 mW Connection data Connection method Screw connection Stripping length 12 mm 01/17/2021Page2/7 https://www.phoenixcontact.com/us/products/2864419 Loop-powered isolators-MINI MCR-SL-1CP-I-I-2864419 Technical data Connection data Screw thread M3 Conductor cross section solid 0.2 mm ... 2.5 mm Conductor cross section flexible 0.2 mm ... 2.5 mm Conductor cross section AWG 26 ... 12 General No. of channels 1 Maximum transmission error 0.1 % (of final value) Maximum temperature coefficient 0.002 %/K (of measured value / 100 load) Temperature coefficient, typical < 0.002 %/K (of measured value / 100 load) Cold junction errors Typical cold point errors Additional error, load-dependent < 0.03 % (of measured value / 100 load) Limit frequency (3 dB) 75 Hz Step response (10-90%) 5 ms (at 600 load) Electrical isolation Basic insulation according to EN 61010 Overvoltage category II Degree of pollution 2 Rated insulation voltage 50 V AC/DC Test voltage input/output 1.5 kV (50 Hz, 1 min.) Test voltage channel/channel 1.5 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color green Housing material PBT Mounting position any Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 EMC data Designation Electromagnetic RF field Standards/regulations EN61000-4-3 Evaluation criterion A Designation Fast transients (burst) 01/17/2021Page3/7 https://www.phoenixcontact.com/us/products/2864419 Loop-powered isolators-MINI MCR-SL-1CP-I-I-2864419 Technical data EMC data Standards/regulations EN61000-4-4 Evaluation criterion B Designation Conducted interferences Standards/regulations EN61000-4-6 Evaluation criterion A Standards and Regulations Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Connection in acc. with standard CUL Standards/regulations EN 61000-4-2 Designation Electromagnetic RF field Standards/regulations EN61000-4-3 Evaluation criterion A Standards/regulations EN61000-4-4 EN61000-4-5 Designation Conducted interferences Standards/regulations EN61000-4-6 Evaluation criterion A Electrical isolation Basic insulation according to EN 61010 Conformance CE-compliant ATEX II 3 G Ex nA II T6 X UL, USA/Canada UL 508 Recognized Class I, Div. 2, Groups A, B, C, D GL GL EMC 2 D Conformance/approvals Designation CE Identification CE-compliant Designation UL, USA/Canada Identification UL508 Recognized Class I, Div. 2, Groups A, B, C, D Designation Shipbuilding approval Certificate DNV GL TAA00000BW Temperature B Humidity B Vibration B EMC B 01/17/2021Page4/7 https://www.phoenixcontact.com/us/products/2864419 Loop-powered isolators-MINI MCR-SL-1CP-I-I-2864419 Technical data Conformance/approvals Enclosure A Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Application drawing Block diagram PLC / DCS UV = 1,7 V I UE I OUT IN Sensor / Field UB OUT I I RB US 4-wire I GND MINI MCR-SL-1CP-I-I 1 + 1 PWR max.18 VDC IN I OUT I 5 + 5 active 2 - 2 3 4 GND 1 passive GND 2 6 - 6 7 8 Zone 2 Dimensional drawing 93,1 102,5 6,2 Classifications eCl@ss eCl@ss 10.0.1 27210120 eCl@ss 11.0 27210120 eCl@ss 4.0 27210100 01/17/2021Page5/7 https://www.phoenixcontact.com/us/products/2864419 Loop-powered isolators-MINI MCR-SL-1CP-I-I-2864419 Classifications eCl@ss eCl@ss 4.1 27210100 eCl@ss 5.0 27210100 eCl@ss 5.1 27210100 eCl@ss 6.0 27210100 eCl@ss 7.0 27210120 eCl@ss 8.0 27210120 eCl@ss 9.0 27210120 ETIM ETIM 4.0 EC002653 ETIM 5.0 EC002653 ETIM 6.0 EC002653 ETIM 7.0 EC002653 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 UNSPSC 18.0 39121008 UNSPSC 19.0 39121008 UNSPSC 20.0 39121008 UNSPSC 21.0 39121008 Approvals Approvals Approvals DNV GL / UL Recognized / cUL Recognized / cULus Recognized Ex Approvals ATEX / UL Recognized / cUL Recognized / EAC Ex / cULus Recognized Approval details 01/17/2021Page6/7 https://www.phoenixcontact.com/us/products/2864419 Loop-powered isolators-MINI MCR-SL-1CP-I-I-2864419 Approvals DNV GL https://approvalfinder.dnvgl.com/ TAA00000BW UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 cULus Recognized Accessories Accessories Marking material Marking label-MINI MCR-DKL-LABEL-2810272 Label for extended marking of MINI MCR modules in connection with the MINI MCR-DKL Transparent cover-MINI MCR DKL-2308111 Fold up transparent cover for MINI MCR modules with additional labeling option using insert strips and flat Zack marker strip 6.2 mm Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 01/17/2021Page7/7