2
Date : April 1999
Dual Lock Fastening System
Performance
Characteristics
Dynamic Performance :
Closure Combination of Types
Property Surface 170 to 400 250 to 250 250 to 400 400 to 400 170 to loop 250 to loop
Tensile
disengagement
Lbs/sq.in.
(kPa)
Rigid
to
Rigid 32
(221)
Clear
38
(262)
Black
30
(207) 47
(324) 55
(380)
Peel Strength
Lbs/sq.in.
(N.100mm)
Rigid
to
Flexible 10
(175) 8
(140)
Fastener combinations were mated, then disengaged at a rate of 12 inches (305mm)/minute. Tests were conducted under controlled laboratory
conditions at 72°F (22°C), 50% R.H.
Static Performance : Closure Combination of Types
Property Temperatures 170 to 400 250 to 250 250 to 400 400 to 400
Static Shear.
Gram/sq.in. will hold listed
weight for 10,000 minutes.
-20°F (-29°C)
72°F (22°C)
200°F (93°C)
1,000
1,000
500
1,000
1,000
500
1,000
1,000
500
1,000
1,000
500
Static Tensile.
Gram/sq.in. will hold listed
weight for 10,000 minutes.
-20°F (-29°C)
72°F (22°C)
200°F (93°C)
1,000
1,000
500
1,000
1,000
500
1,000
1,000
500
1,000
1,000
500
Fasteners were attached to metal panels and engaged in the combinations listed. Tests were conducted at the temperatures and gram loadings
listed. Tests were discontinued after 10,000 minutes (7 days).
Static Performance : Adhesive Bond
Property Temperatures SJ3540/41/42 SJ3550/51/52 SJ3560
Static Shear.
Gram/sq.in. will hold listed
weight for 10,000 minutes.
-20°F (-29°C)
72°F (22°C)
120°F (49°C)
200°F (93°C)
1,000
1,000
500
-
1,000
1,000
1,000
500
1,000
1,000
1,000
500
Static Tensile.
Gram/sq.in. will hold listed
weight for 10,000 minutes.
-20°F (-29°C)
72°F (22°C)
120°F (49°C)
200°F (93°C)
1,000
1,000
500
-
1,000
1,000
1,000
500
1,000
1,000
1,000
500
Fasteners were attached to aluminium and stainless steel panels and engaged in the combinations listed. Tests were conducted at the
temperatures and gram loadings listed. Tests were discontinued after 10,000 minutes (7 days).
NOTE: In static load applications, conditions such as temperature variation, vibration, jarring, etc. Can affect long term performance. The user
should design the amount of fastening area based on specific conditions in the application. Four square inches of fastening area per pound of
static load is suggested as a starting point for evaluation.