2460 SourceMeter(R) SMU Instrument * One tightly coupled instrument that combines capabilities from analyzers, curve tracers, and I-V systems at a fraction of their cost * Wide coverage up to 105V, 7A DC/7A pulse, 100W max. * Five-inch, high resolution capacitive touchscreen GUI Learn Faster, Work Smarter, Invent Easier The Model 2460 features a five-inch, full-color, high resolution touchscreen that supports intuitive operation, helps operators become familiar with the instrument quickly, and optimizes overall speed and productivity. A simple icon-based menu structure reduces the number of steps required to configure a test by as much as 50 percent and eliminates the cumbersome multi-layer menu structures typically used on soft-key instruments. Built-in, context-sensitive help supports intuitive operation and minimizes the need to review a separate manual. These capabilities, combined with the Model 2460's high versatility, simplify its operation in both basic and advanced measurement applications, regardless of the user's previous experience in working with SMU instruments. * 0.012% basic measure accuracy with 61/2-digit resolution Model 2460 SourceMeter(R) SMU Instrument The Model 2460 High Current SourceMeter(R) Source Measure Unit (SMU) Instrument brings advanced Touch, Test, Invent(R) technology right to your fingertips. It combines an innovative graphical user interface (GUI) with capacitive touchscreen technology to make testing intuitive and minimize the learning curve to help engineers and scientists learn faster, work smarter, and invent easier. With its 7A DC and pulse current capability, the Model 2460 is optimized for characterizing and testing high power materials, devices, and modules such as silicon carbide (SiC), gallium nitride (GaN), DC-DC converters, power MOSFETs, solar cells and panels, LEDs and lighting systems, electrochemical cells and batteries, and much more. These new capabilities, combined with Keithley's decades of expertise in developing high precision, high accuracy SMU instruments, will make the Model 2460 a "go-to instrument" for high current applications in the lab and in the rack for years to come. * Source and sink (4-quadrant) operation * Four "Quickset" modes for fast setup and measurements * Context-sensitive help function 2460 main home screen The Model 2460's icon-based menu structure helps even novice users configure tests quickly and confidently. * Front panel input banana jacks; rear panel input mass termination screw connections +7A * 2460 SCPI and TSP(R) scripting programming modes * Front-panel USB 2.0 memory I/O port for transferring data, test scripts, or test configurations +5A +4A Quadrant II - Sink Quadrant I + Source Quadrant III - Source Quadrant IV + Sink +1A 0A -1A -4A -5A -7A -100V -20V -10V 0V +10V +20V DC or Pulsed Model 2460 power envelope. 1.888.KEITHLEY (U.S. only) www.keithley.com +100V All-in-One SMU Instrument The Model 2460, built on the fourth generation of the award-winning SourceMeter SMU platform, leverages the proven capabilities of previously introduced high current SMU instruments from Keithley, including the Models 2420, 2425, and 2440. It offers a highly flexible, four-quadrant voltage and current source/load coupled with precision voltage and current measurements. This all-in-one instrument can be used as a: * Precision power supply with V and I readback * True current source * Digital multimeter (DCV, DCI, ohms, and power with 61/2-digit resolution) * Precision electronic load * Trigger controller A Tektronix Company SMU INSTRUMENTS Model 2460 SourceMeter(R) SMU Instrument 100 Watts, 7 Amps 2460 SourceMeter(R) SMU Instrument Ordering Information Model 2460 SourceMeter(R) SMU Instrument 2460 100V, 7A, 100W SourceMeter Instrument 2460-NFP 100V, 7A, 100W SourceMeter Instrument, with No Front Panel 2460-RACK 100V, 7A, 100W SourceMeter Instrument, without Handle 2460-NFP-RACK 100V, 7A, 100W SourceMeter Instrument, with No Front Panel and No Handle Accessories Supplied 2460-KIT Rear Panel Mating Mass Terminated Screw Connector 8608 High Performance Test Leads USB-B-1 USB Cable, Type A to Type B, 1m (3.3 ft) CS-1616-3 Safety Interlock Mating Connector CA-180-3A TSP-Link/Ethernet Cable Documentation CD Model 2420/2425/2440 Max Voltage: 60V/100V/40V Max Current: 3A/3A/5A DC Power: 60W/100W/50W Wideband Noise: 10mVrms ttyp. Sweep Types: Linear, Log, Custom, Source-Memory 5000 Point Reading Buffer >2000 Readings/second SCPI Programming GPIB, RS-232 Front/Rear Banana Jacks Comparison of Models 2420, 2425, and 2440 with Model 2460. Ease of Use Beyond the Touchscreen In addition to its advanced touchscreen, the Model 2460's front panel offers a variety of features that enhance its speed, user-friendliness, and learnability, including a USB 2.0 memory I/O port, a HELP key, a rotary navigation/control knob, a front/rear input selector button, and banana jacks for basic bench applications. The USB 2.0 memory port simplifies storing test results and instrument configurations, uploading test scripts into the instrument, and installing system upgrades. All front-panel buttons are backlit to enhance visibility in low-light environments. 5 color graphical touchscreen display Online HELP key USB 2.0 memory I/O 2460 QuickStart Guide Test Script Builder Software (available at www.keithley.com) KickStart Startup Software (available at www.keithley.com) SMU INSTRUMENTS LabVIEW and IVI Drivers (available at www.keithley.com) Model 2460 Max Voltage: 100V Max Current: 7A DC Power: 100W Wideband Noise: 2mVrms typ. Sweep Types: Linear, Log, Dual Linear, Dual Log, Custom >250,000 Point Reading Buffer >3000 Readings/second SCPI Programming + TSP Scripting GPIB, USB, Ethernet (LXI) Front: Banana Jacks Rear: Mass Screw Terminal Connection Rotary navigation/ control knob Front/rear input selector The Model 2460's high resolution, capacitive touchscreen and front panel controls allow for intuitive operation, even by novice users. Four "Quickset" modes simplify instrument setup. With one touch, the instrument can be quickly configured for various operating modes without the need to configure the instrument indirectly for this operation. One-touch Quickset modes speed measurement setups and minimize the time to measurements. 1.888.KEITHLEY (U.S. only) www.keithley.com A Tektronix Company Model 2460 SourceMeter(R) SMU Instrument 100 Watts, 7 Amps 2460 SourceMeter(R) SMU Instrument 100 Watts, 7 Amps Model 2460 SourceMeter(R) SMU Instrument Mass screw terminal connections Interlock Ethernet USB Digital I/O TSP-Link GPIB Model 2460 rear panel connections are optimized to maintain signal integrity and speed system setup. Convert Raw Data to Information A full graphical plotting window converts raw data and displays it immediately as useful information, such as semiconductor I-V curves and voltammograms. Using the Model 2460's Sheet view, test data can also be displayed in tabular form. The instrument supports exporting data to a spreadsheet for further analysis, dramatically improving productivity for research, benchtop testing, device qualification, and debugging. TriggerFlow Building Blocks for Instrument Control and Execution The Model 2460 incorporates Keithley's TriggerFlow triggering system, which provides user control over instrument execution. TriggerFlow diagrams are created in much the same way that flow charts are developed, using four fundamental building block types: * Wait - Waits for an event to occur before the flow continues * Branch - Branches when a condition has been satisfied * Action - Initiates an action in the instrument, for example, measure, source, delay, set digital I/O, etc. * Notify - Notifies other equipment that an event has occurred A TriggerFlow model using a combination of these building blocks can be created from the front panel or by sending remote commands. With the TriggerFlow system, users can build triggering models from very simple to complex with up to 255 block levels. The Model 2460 also includes basic triggering functions, including immediate, timer, and manual triggering. (R) 1.888.KEITHLEY (U.S. only) www.keithley.com Built-in data display, charting, and spreadsheet export functions simplify converting test results into useful information. TriggerFlow building blocks allow creating triggering models that range from very simple to highly complex. A Tektronix Company SMU INSTRUMENTS Model 2460 SourceMeter(R) SMU Instrument Comprehensive Built-in Connectivity Rear panel access to rear-input mass termination connector, remote control interfaces (GPIB, USB 2.0, and LXI/Ethernet), D-sub 9-pin digital I/O port (for internal/external trigger signals and handler control), instrument interlock control, and TSP-Link(R) jacks make it simple to configure multiple instrument test solutions and eliminate the need to invest in additional adapter accessories. 2460 SourceMeter(R) SMU Instrument SMU INSTRUMENTS Unmatched System Integration and Programming Flexibility When a Model 2460 is configured into a multi-channel I-V test system, its embedded Test Script Processor (TSP(R)) allows it to run test scripts, so users can create powerful measurement applications with significantly reduced development times. TSP technology also offers channel expansion without a mainframe. Keithley's TSP-Link(R) channel expansion bus, which uses a 100 Base T Ethernet cable, can connect multiple Model 2460s and other TSP instruments such as Keithley's Model 2450 SourceMeter SMU Instruments, Series 2600B System SourceMeter SMU instruments, and Series 3700A Switch/Multimeter systems in a master-slave configuration that operates as one integrated system. The TSP-Link expansion bus supports up to 32 units per GPIB or IP address, making it easy to scale a system to fit an application's particular requirements. The Model 2460 also includes a SCPI programming mode that takes advantage of all of the instrument's capabilities. Parallel Test Capability The TSP technology in the Model 2460 supports testing multiple devices in parallel to meet the needs of device research, advanced semiconductor lab applications, and even high throughput production test. This parallel testing capability allows each instrument in the system to run its own complete test sequence, creating a fully multi-threaded test environment. The number of tests that can be run in parallel on a Model 2460 can be as high as the number of instruments in the system. Free Instrument Control Start-up Software The Model 2460 comes with KickStart instrument control/start-up software, which lets users start taking measurements in minutes without programming. In most cases, users merely need to make some quick measurements, graph the data, and store the data to disk for later analysis in software environments such as Excel. KickStart offers: * Instrument configuration control to perform I-V characterization * Native X-Y graphing, panning, and zooming * Spreadsheet/tabular viewing of data * Saving and exporting data for further analysis * Saving of test setups * Screenshot capturing of graph * Annotation of tests * Command line dialog for sending and receiving data * HTML help * GPIB, USB 2.0, Ethernet compliance Simplified Programming with Ready-to-Use Instrument Drivers For those who prefer to create their own customized application software, native National Instruments LabVIEW(R) drivers, as well as IVI-C and IVICOM drivers are available at www.keithley.com. 1.888.KEITHLEY (U.S. only) www.keithley.com TYPICAL APPLICATIONS Ideal for current/voltage characterization and functional test of a wide range of modern electronic devices: * Power semiconductors and materials -- SiC, GaN -- IBGTs -- Power MOSFETs -- Thyristors Model 2460 SourceMeter(R) SMU Instrument Model 2460 SourceMeter(R) SMU Instrument 100 Watt, 7 Amps * Power devices -- Telecom power management chipsets -- DC-DC converters * Electrochemistry -- Galvanic cycling -- Cyclic voltammetry -- Electro-deposition * Energy generation -- Solar cells -- Batteries * Efficient energy consumption -- LEDs/AMOLEDs -- Automotive modules -- Power management modules KickStart start-up software lets users be ready to take measurements in minutes. A Tektronix Company 2460 SourceMeter(R) SMU Instrument 100 Watt, 7 Amps Voltage Specifications 1, 2 CABLES, CONNECTORS, ADAPTERS 2460-BAN Screw Terminal Connector to Banana Cable 2460-KIT Mating Mass Termination Connector 8607 2-Wire, 1000V Banana Cables, 1m (3.3 ft.) CS-1616-3 Safety Interlock Mating Connector COMMUNICATION INTERFACES & CABLES 7007-1 Shielded GPIB Cable, 1m (3.3 ft) 7007-2 Shielded GPIB Cable, 1m (6.6 ft) CA-180-3A CAT5 Crossover Cable for TSP-Link/Ethernet KPCI-488LPA IEEE-488 Interface for PCI Bus KUSB-488B IEEE-488 USB-to-GPIB Interface Adapter USB-B-1 USB Cable, Type A to Type B, 1m (3.3 ft) TRIGGERING 2450-TLINK 8501-1 8501-2 AND CONTROL DB-9 to Trigger Link Connector Adapter. Trigger Link Cable, DIN-to-DIN, 1m (3.3 ft) Trigger Link Cable, DIN-to-DIN, 2m (6.6 ft) RACK MOUNT KITS 4299-8 Single Fixed Rack Mount Kit 4299-9 Dual Fixed Rack Mount Kit 4299-10 Dual Fixed Rack Mount Kit. Mount one 2460 and one Series 26xxB 4299-11 Dual Fixed Rack Mount Kit. Mount one 2460 and one Series 2400, Series 2000, etc. 2450-BenchKit Ears and Handle for 2460-NFP-RACK and 2460-RACK models Source Range 200.0000 mV 2.000000 V 7.000000 V 10.00000 V 20.00000 V 100.0000 V Max. ResoCurrent lution 7.35 A 5 V 7.35 A 50 V 7.35 A 250 V 5.25 A 500 V 4.20 A 500 V 1.05 A 2.5 mV 1 Year Factory Warranty extended to 3 years from date of shipment 2460-5Y-EW 1 Year Factory Warranty extended to 5 years from date of shipment C/2460-3Y-17025 KeithleyCare(R) 3 Year ISO 17025 Calibration Plan C/2460-3Y-DATA KeithleyCare 3 Year Calibration w/Data Plan C/2460-3Y-STD KeithleyCare 3 Year Std. Calibration Plan C/2460-5Y-17025 KeithleyCare 5 Year ISO 17025 Calibration Plan C/2460-5Y-DATA KeithleyCare 5 Year Calibration w/Data Plan C/2460-5Y-STD KeithleyCare 5 Year Std. Calibration Plan C/NEW DATA Calibration Data for New Units C/NEW DATA ISO ISO-17025 Calibration Data for New Units Noise (RMS) (<10Hz) 1 V 10 V 100 V 100 V 100 V 1 mV ResoInput lution4 Resistance 100 nV >10 GW 1 V >10 GW 1 V >10 GW 10 V >10 GW 10 V >10 GW 100 V >10 GW Accuracy (23 5C), 1 Year (% rdg. + volts) 0.012 % + 200 V 0.012 % + 300 V 0.015 % + 1 mV 0.015 % + 1 mV 0.015 % + 1 mV 0.015 % + 5 mV Current Specifications 1, 2, 5 Source Range 1.000000 A 10.00000 A 100.0000 A 1.000000 mA 10.00000 mA 100.0000 mA 1.000000 A 4.000000 A 5.000000 A 7.000000 A Max. Voltage 105 V 105 V 105 V 105 V 105 V 105 V 105 V 21 V 10.5 V 7.35 V Resolution 50 pA 500 pA 5 nA 50 nA 500 nA 5 A 50 A 250 A 250 A 500 A Measure 3 Accuracy (23 5C), 1 Year (% setting + amps) 0.025 % + 1 nA 0.025 % + 1.5 nA 0.020 % + 15 nA 0.020 % + 150 nA 0.020 % + 1.5 A 0.020 % + 15 A 0.050 % + 750 A 0.100 % + 3 mA 0.100 % + 3 mA 0.150 % + 6 mA Noise (RMS) (<10Hz) 40 pA 40 pA 100 pA 1 nA 10 nA 100 nA 5 A 25 A 25 A 125 A Resolution4 1 pA 10 pA 100 pA 1 nA 10 nA 100 nA 1 A 1 A 1 A 1 A Voltage Burden 6 <100 V <100 V <100 V <100 V <100 V <100 V <100 V <100 V <100 V <100 V Accuracy (23 5C), 1 Year (% rdg. + amps) 0.025 % + 700 pA 0.025 % + 1 nA 0.020 % + 10 nA 0.020 % + 100 nA 0.020 % + 1 A 0.020 % + 10 A 0.050 % + 500 A 0.100 % + 2.5 mA 0.100 % + 2.5 mA 0.150 % + 5 mA TEMPERATURE COEFFICIENT (0-18C and 28-50C): (0.10 x accuracy specification)/C. 1. 2. 3. 4. 5. 6. Speed = 1 PLC. All specifications are guaranteed with output ON. Accuracies apply to 2- and 4-wire mode when properly zeroed. 6.5-digit measure resolution. Accuracy specifications guaranteed when using 2460-KIT screw terminal accessory. Four-wire mode. Resistance Measurement Accuracy (Local or Remote Sense) 7, 8, 9 SERVICES AVAILABLE 2460-3Y-EW Measure 3 Accuracy (23 5C), 1 Year (% setting+volts) 0.015 % + 200 V 0.015 % + 300 V 0.015 % + 2.4 mV 0.015 % + 2.4 mV 0.015 % + 2.4 mV 0.015 % + 15 mV Range <2.000000 W 12 20.00000 W 200.0000 W 2.000000 kW 20.00000 kW 200.0000 kW 2.000000 MW 20.00000 MW >20.0000 MW 12 Default Default Resolution 10 Test Current 1 W User defined 10 W 100 mA 100 W 10 mA 1 mW 1 mA 10 mW 100 A 100 mW 10 A 1 W 10 A 10 W 1 A -- User defined Normal Accuracy (23C 5C) 1 Year, (% rdg. + ohms) Source I ACC + Meas. VACC 0.05 % + 0.003 0.05 % + 0.03 0.05 % + 0.3 0.05 % + 3 0.05 % + 30 0.06 % + 100 0.14 % + 1000 Source I ACC + Meas. VACC Enhanced Accuracy 11 (23C 5C) 1 Year, (% rdg. + ohms) Meas. I ACC + Meas. VACC 0.04 % + 0.001 0.04 % + 0.01 0.04 % + 0.1 0.04 % + 1 0.05 % + 10 0.06 % + 50 0.12 % + 500 Meas. I ACC + Meas. VACC TEMPERATURE COEFFICIENT (0-18C and 28-50C): (0.10 x accuracy specification)/C. SOURCE CURRENT, MEASURE RESISTANCE MODE: Total uncertainty = I source accuracy + V measure accuracy (4-wire remote sense). SOURCE VOLTAGE, MEASURE RESISTANCE MODE: Total uncertainty = V source accuracy + I measure accuracy (4-wire remote sense). 7. Speed = 1 PLC. 8. All specifications are guaranteed with output ON. 9. Accuracies apply to 2- and 4-wire mode when properly zeroed. 10. 6.5-digit measure resolution. 11. Source readback enabled. Offset compensation ON. 12. Source current, measure resistance or source voltage, measure resistance only. 1.888.KEITHLEY (U.S. only) www.keithley.com Model 2460 specifications Model 2460 specifications TEST LEADS AND PROBES 1754 2-wire Universal 10-Piece Test Lead Kit 5805 Kelvin (4-Wire) Spring-Loaded Probes 5808 Low Cost Single-pin Kelvin Probe Set 5809 Low Cost Kelvin Clip Lead Set 8605 High Performance Modular Test Leads 8606 High Performance Modular Probe Kit 8608 High Performance Clip Lead Set SMU INSTRUMENTS ACCESSORIES AVAILABLE A Tektronix Company 2460 SourceMeter(R) SMU Instrument 100 Watts, 7 Amps SUPPLEMENTAL CHARACTERISTICS OVERRANGE: REGULATION: SOURCE LIMITS: Model 2460 specifications V-LIMIT / I-LIMIT ACCURACY: OVERSHOOT: RANGE CHANGE OVERSHOOT: OUTPUT SETTLING TIME: MAXIMUM SLEW RATE: OVER VOLTAGE PROTECTION: VOLTAGE SOURCE NOISE: COMMON MODE VOLTAGE: COMMON MODE ISOLATION: NOISE REJECTION (TYPICAL): LOAD IMPEDANCE: 100W, four-quadrant source or sink operation. Vsource: 7.35V (7A range), 10.5V (5A range), 21V (4A range), 105V (1A range). Isource: 7.35A (7V range), 5.25mA (10V range), 4.2A (20V range), 1.05mA ( 100V range). 105% of range, source and measure. Voltage: Line: 0.01% of range. Load: 0.01% of range + 100V. Current: Line: 0.01% of range. Load: 0.01% of range + 100pA. Voltage Source Current Limit: Bipolar current limit set with single value. Min. 10% of range. Current Source Voltage Limit: Bipolar voltage limit set with single value. Min. 10% of range. Add 0.3% of setting and 0.02% of reading to base specification. Voltage Source: <0.1% typical (full scale step, resistive load, 20V range, 10mA I-Limit. Current Source: <0.1% typical (1mA step, R Load = 10kW, 20V range) Overshoot into a fully resistive 100kW load, 10Hz to 20MHz BW, adjacent ranges: <250mV typical Time required to reach 0.1% of final value, 20V range, 100mA I-Limit: <200s typical. 1V per s, 100V range, 100mA limit into a 20kW load (typical). 0.6V per s, 20V range, 100mA limit into a 20kW load (typical). User selectable values, 5% 0.5V tolerance. Factory default = none. 10Hz-20MHz (RMS): <4.5mV typical into a resistive load. 250V DC. >1GW, <1000pF. NPLC NMRR CMRR 0.01 -- 60 dB 0.1 -- 60 dB 1 60 dB 100 dB Model 2460 specifications MAX. OUTPUT POWER: SOURCE LIMITS: Normal Mode: 20nF typical. High Capacitance Mode: Stable into 50F typical. High-C mode valid for 100A ranges. MAX. VOLTAGE DROP BETWEEN FORCE and SENSE TERMINALS: 5V. MAX. SENSE LEAD RESISTANCE: 1MW for rated accuracy. SENSE INPUT IMPEDANCE: >10GW. GUARD OFFSET VOLTAGE: <300V, typical System Measurement Speeds 13 Reading rates (readings per second) typical for 60Hz (50Hz), script (TSP(R)) programmed NPLC 0.01 NPLC 0.01 NPLC 0.1 NPLC 0.1 NPLC 1 NPLC 1 NPLC Trigger Origin Internal External Internal External Internal External Measure to Memory 3050 (2800) 2300 (2100) 540 (460) 500 (420) 59 (49) 58 (48) Measure to GPIB/USB/LAN 2800 (2500) 2150 (2000) 530 (450) 500 (420) 59 (49) 58 (48) Source Measure to Memory 1700 (1600) 1650 (1550) 470 (410) 460 (390) 58 (48) 57 (48) Source Measure to GPIB/USB/LAN 1650 (1550) 1600 (1450) 470 (400) 450 (350) 58 (48) 57 (46) Source Measure to Memory 1700 (1600) 1650 (1550) 470 (410) 470 (400) 58 (48) 58 (48) Source Measure to GPIB/USB/LAN 1550 (1500) 1500 (1450) 460 (400) 460 (390) 58 (48) 58 (48) SMU INSTRUMENTS Reading rates (readings per second) typical for 60Hz (50Hz), SCPI programmed NPLC 0.01 NPLC 0.01 NPLC 0.1 NPLC 0.1 NPLC 1 NPLC 1 NPLC Trigger Origin Internal External Internal External Internal External Measure to Memory 3000 (2800) 2330 (2150) 540 (460) 510 (430) 59 (49) 58 (49) 1.888.KEITHLEY (U.S. only) www.keithley.com Measure to GPIB/USB/LAN 3000 (2790) 2330 (2150) 540 (460) 510 (430) 59 (49) 58 (49) A Tektronix Company 2460 SourceMeter(R) SMU Instrument 100 Watts, 7 Amps LXI COMPLIANCE: 1.4 LXI Core 2011. DISPLAY: 5 inch capacitive touch, color TFT WVGA (800x480) with LED backlight. INPUT SIGNAL CONNECTIONS: Front: Banana. Rear: Mass termination screw terminal. INTERLOCK: Active High Input. COOLING: Forced air, variable speed. OVER TEMPERATURE PROTECTION: Internally sensed temperature overload puts unit in standby mode. POWER SUPPLY: 100V to 240V RMS, 50-60Hz (automatically detected at power up). VA RATING: 350 volt-amps max. ALTITUDE: Maximum 2000 meters above sea level. EMC: Conforms to European Union EMC Directive. SAFETY: Compliance with CE and NRTL listed to UL61010-1 and UL61010-2-30. Conforms with European Union Low Voltage Directive. VIBRATION: MIL-PRF-28800F Class 3 Random. WARM-UP: 1 hour to rated accuracies. DIMENSIONS: (With handle and bumpers): 106mm high x 255mm wide x 425mm deep (4.18 in x 10.05 in x 16.75 in). (Without handle and bumpers): 88mm high x 213mm wide x 397mm deep (3.46 in x 8.39 in x 15.63 in.) WEIGHT: With bumpers and handle: 4.75 kg (10.5 lbs.). Without bumpers and handle: 4.35 kg (9.6 lbs.). ENVIRONMENT: Operating: 0-50C, 70% R.H. up to 35C. Derate 3% R.H./C, 35-50C, non-condensing. Storage: -25C to 65C. ACCESSORIES SUPPLIED: Test Leads, Mating Mass Terminated Screw Connector, USB Cable, Ethernet/TSP Cable, Interlock Adapter, Power Cord, QuickStart Guide, CD User's Manual. Model 2460 specifications FACTORY DEFAULT STANDARD POWER-UP: SCPI MODE. SOURCE OUTPUT MODES: Fixed DC Level, Memory/Configuration List (mixed function), Sweep (linear and logarithmic), Sweep (dual linear and dual logarithmic. MEMORY BUFFER: >250,000 readings. Includes selected measured value(s) and time stamp. REAL-TIME CLOCK: Lithium battery backup (3 yr. + battery life). REMOTE INTERFACES: GPIB: IEEE-488.1 compliant. Supports IEEE-488.2 common commands and status model topology. USB Device (rear panel, type B): 2.0 Full Speed USBTMC. USB Host (front panel, type A): USB 2.0, support for flash drives, FAT32. Ethernet: RJ-45 (10/100BT) DIGITAL I/O INTERFACE: Lines: 6 Input/Output user defined for digital I/O or triggering Connector: 9-pin female D Input Signal Levels: 0.7V (maximum logic low), 3.7V (minimum logic high) Input Voltage Limits: -0.25V (Abs. minimum), +5.25V (Abs. maximum) Maximum Source Current: +2.0mA @ >2.7V (per pin) and sink (4-quadrant) operation Source Maximum Sink Current: -50mA @ 0.7V (per pin, solid-state fuse protected) 5V Power Supply Pin: Limited to 500mA @ >4V (solid-state fuse protected) Handler: User definable Start of Test, End of Test, 4 category bits PROGRAMMABILITY: SCPI or TSP command sets. TSP MODE: Embedded Test Script Processor (TSP) accessible from any host interface. IP CONFIGURATION: Static or DHCP EXPANSION INTERFACE: The TSP-Link expansion interface allows TSP enabled instruments to trigger and communicate with each other. SMU INSTRUMENTS Model 2460 specifications GENERAL CHARACTERISTICS (default mode unless specified) 1.888.KEITHLEY (U.S. only) www.keithley.com A Tektronix Company Specifications are subject to change without notice. All Keithley trademarks and trade names are the property of Keithley Instruments. All other trademarks and trade names are the property of their respective companies. A Tektronix Company A Greater Measure of Confidence SMU INSTRUMENTS KEITHLEY INSTRUMENTS 28775 AURORA RD. CLEVELAND, OH 44139-1891 440-248-0400 Fax: 440-248-6168 1-888-KEITHLEY www.keithley.com BENELUX +31-40-267-5506 www.keithley.nl FRANCE +33-01-69-86-83-60 www.keithley.fr ITALY +39-049-762-3950 www.keithley.it MALAYSIA 60-4-643-9679 www.keithley.com SINGAPORE 01-800-8255-2835 www.keithley.com.sg BRAZIL 55-11-4058-0229 www.keithley.com GERMANY +49-89-84-93-07-40 www.keithley.de JAPAN 81-120-441-046 www.keithley.jp MEXICO 52-55-5424-7907 www.keithley.com TAIWAN 886-3-572-9077 www.keithley.com.tw CHINA 86-10-8447-5556 www.keithley.com.cn INDIA 080-30792600 www.keithley.in KOREA 82-2-6917-5000 www.keithley.co.kr RUSSIA +7-495-664-7564 www.keithley.ru UNITED KINGDOM +44-1344-39-2450 www.keithley.co.uk For further information on how to purchase or to locate a sales partner please visit www.keithley.com/buy (c) Copyright 2014 Keithley Instruments Printed in the U.S.A No. 3275 11.4.14