AWi 30.06.2008
HARTING PROFINET Hybrid Cable, 4-wire + 4x1.5 , Cat. 5, FRNC
PROFINET Hybrid Cable,
4-wire + 4x1.5, Cat. 5, FRNC
Advantages
General
Suitable for PROFINET cabling
Category 5 / Class D according to
ISO/IEC 11801 respectively EN
50173-1 and ISO/IEC 24702
respectively EN 50173-3
Capable for flexible cords
Applicable for industrial premises
RoHS conform, UL recognized,
flame retardant FRNC
This data cable is suitable for PROFINET Hybrid
cabling according to type B in industrial premises and
areas. It is useable for flexible cords and installation
also. The core is fitted with 4 data wires twisted to star
quad that allows the transmission of Fast Ethernet
10/100Mbit/s and 4 power wires each of 1.5 mm²
cross section.
It is designed for fast assembling in benefit for the
customer. The PROFINET Hybrid cable is best
capable for termination with Han 3 A RJ45 Hybrid
connector set.
Description
Order number
PROFINET Hybrid Cable,
4-wire + 4x1.5, Cat. 5, FRNC
10 m ring
20 m ring
50 m ring
100 m ring
500 m reel
09 45 600 0310
09 45 600 0330
09 45 600 0340
09 45 600 0300
09 45 600 0320
Quad
Wire: Stranded tinned copper AWG
22/7
Insulation: PE 1.55 mm
Colour: wh, ye, bu, og
Screen: Aluminate foil overlapped,
tinned copper wire braid, braid
coverage about 85%
Power
Wire: Stranded bare copper 84 x
0.15mm (AWG 16)
Insulation: FRNC 2.4 mm
Colour: bk, number printed
Core
Plastic tape overlaped
Outer sheath: Thermoplastic
Copolymer (FRNC), flame retardant
Color of outer sheath: green, RAL 6018
Overall diameter: 9.7 mm – 10.3 mm
All data given are in line with the actual state of art and therefore not binding.
HARTING reserves the right to modify designs without giving the relevant reasons.
AWi 30.06.2008
HARTING PROFINET Hybrid Cable, 4-wire + 4x1.5 , Cat. 5, FRNC
Technical Characteristics
Performance
Mechanical Characteristics
Minimal bending radius
Tensile strength
Electrical Characteristics at 20°C
Quad
Surface transfer impedance at 1 MHz
Surface transfer impedance at 10 - 100 MHz
Loop resistance
Insulation resistance
Signal runtime
Characteristic impedance at 100 MHz
Test voltage (wire/wire/screen rms 50Hz 1min)
Operating voltage
Power
Conductor resistance
Insulation resistance
Test voltage (wire/wire/screen rms 50Hz 1min)
Operating voltage
Chemical Characteristics
Flame retardant
Free of hazardous substances
Halogen free
Thermal Characteristics
Permissible temperature range
Printing
Weight about
Category 5 according to EN 50288-2-1:2003, IEC 61156-5:2002
During installation: 10 x diameter
After installation: 5 x diameter
max. 200 N
50 mOhm/m
10 mOhm/m
max. 120 Ohm/km
min. 500 MOhm x km
5.3 ns/m
100 Ohm +/- 5 Ohm
1500 V
150 V
max. 14 Ohm/km
miin. 20 MOhm*km
1500 V
150 V
IEC 60332-1-2
RoHS 2002/95/EG
- 20° C to + 80° C
HARTING PROFINET HYBRID CABLE CAT 5 FRNC *
4xAWG22/7 + 4x1.5 (SHIELDED) E130266 AWM 21282 *
09456000300200 “internal lot number” “sequential length in
meters”
154 kg/km
All data given are in line with the actual state of art and therefore not binding.
HARTING reserves the right to modify designs without giving the relevant reasons.
AWi 30.06.2008
HARTING PROFINET Hybrid Cable, 4-wire + 4x1.5 , Cat. 5, FRNC
Technical Characteristics
Frequency
MHz
Attenuation
dB/100m
NEXT
dB
PS NEXT
dB
EL FEXT
dB
PS EL FEXT
dB
Return Loss
dB
typ. Cat 5
max* typ. Cat 5
min* typ. Cat 5
min* typ. Cat 5
min* typ. Cat 5
min* typ. Cat 5
min*
1 2.1 2.1 65.3 65.3 62.3 62.3 63.8 63.8 60.8 60.8 - -
4 4 4 56.3 56.3 53.3 53.3 51.8 51.8 48.8 48.8 23.0 23
10 6.3 6.3 50.3 50.3 47.3 47.3 43.8 43.8 40.8 40.8 25 25
16 8 8 47.2 47.2 44.2 44.2 39.7 39.7 36.7 36.7 25 25
20 9 9 45.8 45.8 42.8 42.8 37.8 37.8 34.8 34.8 25 25
31.25 11.4 11.4 42.9 42.9 39.9 39.9 33.9 33.9 30.9 30.9 23.6 23.6
62.5 16.5 16.5 38.4 38.4 35.4 35.4 27.9 27.9 24.9 24.9 21.5 21.5
100 21.3 21.3 35.3 35.3 32.3 32.3 23.8 23.8 20.8 20.8 20.1 20.1
* EN 50288-2-1:2003
All data given are in line with the actual state of art and therefore not binding.