GE12 05-P1J GE12 07-P1J GE12 09-P1J GE12 12-P1J GE12 15-P1J GE12 18-P1J GE12 24-P1J
IIIIIII
IIIIIII
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
POWER SUPPLY MAIN BODY ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
SAFETY STANDARDS
SAFETY &
EMC
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
LIFE
DIMENSION
OTHERS
DC OUTPUT
NOTE
PLUG
CABLE
OVERLOAD
OVER VOLTAGE
9V7.5V5V 12V 15V 18V 24V
1.33A1.33A2.0A 1.0A 0.8A 0.83A 0.625A
CURRENT RANGE 0 ~ 1.33A0 ~ 1.33A0 ~ 2.0A 0 ~ 1.0A 0 ~ 0.8A 0 ~ 0.83A 0 ~ 0.625A
RIPPLE & NOISE (max.) Note.3 100mVp-p75mVp-p50mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±3.0% ±3.0%
±1.0% ±1.0% ±1.0%
±5.0%
±5.0%
±5.0%
±5.0%
±1.0% ±1.0%
±5.0%
±5.0%
±3.0%
±3.0%
±1.0%
±3.0%
±3.0%
±1.0%
±3.0% ±3.0%
4000ms, 100ms, 30ms / 230VAC 4000ms, 100ms, 10ms / 115VAC at full load
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
0.4A / 100VAC 0.25A / 230VAC
COLD START 40A / 100VAC 80A / 230VAC
0.25mA / 240VAC
110% ~ 200% rated output power
115% ~ 135%
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
100Khrs min. MIL-HDBK-217F (25 )℃
2 years : 100% load 30 , 8 hours / day℃
-10 ~ +50 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH℃
±℃℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, TUV EN60950 -1, AS/NZS 60950.1, CCC GB4943 approved
70.7*40*38.8mm (L*W*H)
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.Main body unit and AC inlet plug should be ordered seperately ; it needs to be used along with any of the AC inlet plug.
CONNECTOR
FRA012-S05- FRA012-S07- FRA012-S09- FRA012-S12- FRA012-S15- FRA012-S18- FRA012-S24-
RATED POWER 12W 12W12W10W10W 15W 15W
Standard type P1J: 2.1 * 5.5 * 11mm turning fork type, center positive for stock ; Other type available by customer requestedψψ
See page2
■Features :
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode
ENVIRONMENT
PROTECTION
10 ~ 15W AC-DC Single Output Interchangeable Wall-mounted type GE12 series
Interchangeable AC plugs (plug kit sold seperately)
Universal AC input / Full range
No load power consumption< 0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act) for 5~24V
Class power (without earth pin)II
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Pass LPS
Approvals: UL / CUL / TUV / RCM / CCC / CB / FCC / CE
2 years warranty
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254 class B
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
PACKING 97g ; 50pcs / 6.3kg / CARTON
File Name:GE12-SPEC 2014-12-01
79%77%74% 81% 82% 83% 83%
SPECIFICATION
TYPE
ORDER NO.
Australian type U.K type European type US type Mix four type
AC plug-AU AC plug-UK AC plug-EU AC plug-US AC plug-MIX
AC INLET PLUG
EMC IMMUNITY
EMC EMISSION