MYRRA
...Of course !
T R A N S F O R M E R S & I N D U C TO R S
COMPANY PROFILE
50 HZ HF
TWO TECHNOLOGIES
Myrra is a major supplier in high quality for electronics components. Myrra has established
a worldwide reputation.
Awide range of products : We offer application specific transformers, inductors, chokes and coils,
in two technologies high frequency and 50 hz technology, enabling us to serve a number of major
markets.
CONVERSION MEASURING FILTERING
APPLICATIONS
MAGNETICS PRODUCTS
ASIE
18%
EUROPE
40%
USA
42 %
PRODUCT LINES
PRODUCT INDEX
TECHNICALINFORMATIONS ...............................................................4
IENCAPSULATED TRANSFORMERS .......................................5to25
44000 SERIES
0.6VA to 2.8VA/EI30-5 to EI30-18 ....................................................5to13
3.2VA to 30VA/ EI38 to EI66 .......................................................14to19
WITHOTHERBOXES .....................................................................20
45000 SERIES
1VA to 60VA ......................................................................21to24
FLF / FLC SERIES
3.2VA to240VA .........................................................................25
IHIGH FREQUENCY FERRITE ..............................................26to75
POWER FERRITE TRANSFORMERS ....................................................26to48
FLYBACKTRANSFORMERSRANGE ........................................................26
TRANSFORMERS / CONTROL CIRCUITS CROSS REFERENCE LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1Wto12W EE16 ................................................................28to38
10Wto30W EL19 EF20 EE25.....................................................39to42
35Wto180W ETD29 to ETD44 ERL28 ..............................................43to48
COMMON MODE CHOKES FOR EMI SUPPRESSION .....................................49to53
TOROIDAL CHOKES ......................................................................54
CURRENT TRANSFORMERS RANGE ...................................................55to66
PULSE TRANSFORMER RANGE .......................................................67to72
POWER LINE COMMUNICATION COUPLING TRANSFORMERS ...........................73to75
IELECTRONIC TRANSFORMERS ..........................................76to79
ISURFACE MOUNT CHOKES ...................................................80
ITHROUGH HOLES CHOKES ....................................................81
4
TECHNICAL INFORMATION
RATED PRIMARY VOLTAGE (V)
This is the supply voltage assigned to the transformer by the manufacturer.
RATED SECONDARY VOLTAGE (V)
This is the secondary output voltage assigned to the transformer when supplied with the rated primary voltage, frequency range, rated secondary
current, all assigned by the manufacturer for the specified operating conditions of the transformer.
RATED POWER (VA)
The specified power levels in this catalogue are the secondary power levels, in other words, those available when the transformer is loaded. It is the
product of the RMS rated secondary voltage by the RMS rated current. If the transformer has more than one output winding, the rated power
denotes the maximum sum of the products of RMS rated secondary voltage by the RMS rated secondary current, respectively. This rated power is
defined for rated ambient temperature conditions.
example : P = 3,2 VA ta 70/B
The transformer can deliver 3.2VA at maximum ambient (70°C), the load consisting of a resistor load defined by R(load) = U(sec)2/P (assigned U sec &
P values), heating does not exceed the relevant limit for Class B components used in this construction.
NOTE : When the transformer is intended to supply DC voltage and current in conjunction with rectifiers and smoothing capacitors, the VA power
required from the transformer is far higher than the U(DC) and I(DC) product. To help you to determine the true transformer power, our Technical
Department is at your disposal.
AMBIENT TEMPERATURE (ta)
The maximum temperature at which the transformer may be operated continuously under nominal conditions of use. It is the air temperature measu-
red close to the transformer after thermal stabilization when operating at rated conditions.
HEATING
The increase of the winding temperature when operating at rated conditions and maximum ambient temperature. The heating must be determined by
the resistance method.
TEMPERATURE CLASS
The international classification of temperature classes is as follows :
It defines the maximum temperature the transformer components must withstand in continuous operation, in compliance with the 85 IEC publica-
tion classification. There insulating materials are therefore certificated for the thermal index corresponding to the declared class in accordance with
216 IEC standard.
PARTICULAR POINTS OF EN 61558-2-6 STANDARD FOR SAFETY TRANSFORMERS
On-load secondary voltage tolerance.
This should not differ from the rated value by more than :
10% for transformers with build-in resistance to short-circuits (a supplement of 5% is granted on the 2 nd secondary for tranformers with 2
secondaries).
5% for other transformers whatever the secondaries number.
Off-load secondary voltage.
The values given in this catalogue are maximum theoretical values.
NOTE : For safety transformers, this should never exceed 50 V rms. In the case of a transformer with several secondaries, the sum of the
secondary voltages should be less tan 50 V rms.
ADAPTED TRANSFORMERS FROM THE STANDARDS SERIES
Any transformer whose requires Power and Ambient corresponding to those of our 44000 & 45000 range, and whose secondary voltage can fit in our
minimum to maximum secondary range will be covered by EN61558-2-6,EN60950, or UL506 approvals, depending on the effective choice .
SPECIAL TRANFORMERS
MYRRA can use the 44000, 45000 or 46000 standard ranges to examine any transformer for compliance with your specifications and with internatio-
nal standards.
On request, we can add thermal protection, thermal fuse, thermal switch-CTP.
In certain cases, the addition of thermal protection enables the ambient temperature to be increased, while still complying with EN 61558.
A 105°C H 180 °C
E 120°C 200 200 °C
B 130°C 220 220 °C
F 155°C 250 250 °C
PRIMARY VOLTAGE
230 V
PRIMARY VOLTAGE
117 V
44000 SERIES
ENCAPSULATED TRANSFORMERS
5
0,6 VA EI 30-5 SERIE 44000
Rating
VA
Ambient
Temperature
°C
No-load
voltage
V
Secondary
current
m A
Secondary
voltage
V
Reference
Protection
Protection
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
40 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Inherently short-circuits proof
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
EN 61558-2-6 EN 60950 UL 1585
QUALITY IN SERIES
79
51
67 910
51
67 910
51
(Allows the use of a transformer
with 2 secondary windings)
Recommended layout for transformers
with 1 secondary winding
*To be noted : * marked transformers are non approved.
Those transformers meet all requirement of EN 61558-2-4.
44025 6 100 9,94 T 70 B 0,6
44026 9 66 14,95 T 70 B 0,6
44027 12 50 19,9 T 70 B 0,6
44028 15 40 24,9 T 70 B 0,6
44029 18 33 29,9 T 70 B 0,6
44030 24 25 39,8 T 70 B 0,6
44031 2 x 6 2 x 50 2 x 9,94 T 70 B 0,6
44032 2 x 9 2 x 33 2 x 14,95 T 70 B 0,6
44033 2 x 12 2 x 25 2 x 19,9 T 70 B 0,6
44034 2 x 15 2 x 20 2 x 24,9 T 70 B 0,6
44035 2 x 18 2 x 17 2 x 29,9 T 70 B 0,6
44036 2 x 24 2 x 12 2 x 39,8 T 70 B 0,6
44013 6 100 9,94 T 70 B 0,6
44014 9 66 14,95 T 70 B 0,6
44015 12 50 19,9 T 70 B 0,6
44016 15 40 24,9 T 70 B 0,6
44017 18 33 29,9 T 70 B 0,6
44018 24 25 39,8 T 70 B 0,6
44019 2 x 6 2 x 50 2 x 9,94 T 70 B 0,6
44020 2 x 9 2 x 33 2 x 14,95 T 70 B 0,6
44021 2 x 12 2 x 25 2 x 19,9 T 70 B 0,6
44022* 2 x 15 2 x 20 2 x 24,9 T 70 B 0,6
44023* 2 x 18 2 x 17 2 x 29,9 T 70 B 0,6
44024* 2 x 24 2 x 12 2 x 39,8 T 70 B 0,6
PRIMARY VOLTAGE
117 V
44000 SERIES
ENCAPSULATED TRANSFORMERS
6
1-1,8 VA EI 30-10,5 SERIE 44000
Protection
Reference
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
67 910
51
No-load
voltage
V
(Allows the use of a transformer
with 2 secondary windings)
79
51
67 910
51
Recommended layout for transformers
with 1 secondary winding
Primary winding
2 Secondary windings
1 Secondary winding
Primary winding
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
70 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Inherently short-circuits proof
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
44061 6 167 8,6 T 70 B 1
44062 9 111 12,9 T 70 B 1
44063 12 83 17,2 T 70 B 1
44064 15 67 21,6 T 70 B 1
44065 18 56 25,9 T 70 B 1
44066 24 42 37,9 T 70 B 1
44067 2 X 6 2 x 83 2 x 8,6 T 70 B 1
44068 2 x 9 2 x 56 2 x 12,9 T 70 B 1
44069 2 x 12 2 x 42 2 x 19 T 70 B 1
44070 2 x 15 2 x 33 2 x 23,6 T 70 B 1
44071 2 x 18 2 x 28 2 x 24,9 T 70 B 1
44072 2 x 24 2 x 21 2 x 37,9 T 70 B 1
44338 6 250 10,1 ta 70/B 1,5
44339 9 167 15,3 ta 70/B 1,5
44340 12 125 20,2 ta 70/B 1,5
44341 15 100 25,3 ta 70/B 1,5
44342 18 83 31,2 ta 70/B 1,5
44343 24 63 43,3 ta 70/B 1,5
44344 2 x 6 125 2 x 10,1 ta 70/B 1,5
44345 2 x 9 83 2 x 15,3 ta 70/B 1,5
44346 2 x 12 63 2 x 20,2 ta 70/B 1,5
44347 2 x 15 50 2 x 25,0 ta 70/B 1,5
44348* 2 x 18 42 2 x 31 ta 70/B 1,5
44349* 2 x 24 31 2 x 43 ta 70/B 1,5
44840 6 300 10,1 ta 70/B 1,8
44841 9 200 15,2 ta 70/B 1,8
44842 12 150 20,3 ta 70/B 1,8
44843 15 120 27,3 ta 70/B 1,8
44844 18 100 30,4 ta 70/B 1,8
44845 24 75 40,6 ta 70/B 1,8
44846 2 x 6 2 x 150 2 x 10,1 ta 70/B 1,8
44847 2 x 9 2 x 100 2 x 15,2 ta 70/B 1,8
44848 2 x 12 2 x 75 2 x 20,3 ta 70/B 1,8
44849 2 x 15 2 x 60 2 x 27,3 ta 70/B 1,8
PRIMARY VOLTAGE
230 V
44000 SERIES
ENCAPSULATED TRANSFORMERS
7
1-1,8 VA EI 30-10,5 SERIE 44000
Protection
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
Reference
No-load
voltage
V
Items usually available on stock
EN 61558-2-6 EN 60950 UL 1585
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted 2 x 15 V and 2 x 24 V models are non-appro-
ved.
Those transformers meet all requirement of EN 61558-2-4
440496 167 8,6 T 70 B 1
440509 111 12,9 T 70 B 1
4405112 83 17,2 T 70 B 1
4405215 67 21,6 T 70 B 1
4405318 56 25,9 T 70 B 1
4405424 42 37,9 T 70 B 1
440552 x 6 2 x 83 2 x 8,6 T 70 B 1
440562 x 9 2 x 56 2 x 12,9 T 70 B 1
440572 x 12 2 x 42 2 x 19 T 70 B 1
440582 x 15 2 x 33 2 x 23,6 T 70 B 1
440592 x 18 2 x 28 2 x 24,9 T 70 B 1
44060*2 x 24 2 x 21 2 x 37,9 T 70 B 1
44326 6 250 10,1 ta 70/B 1,5
44327 9 167 15,3 ta 70/B 1,5
44328 12 125 20,2 ta 70/B 1,5
44329 15 100 25,3 ta 70/B 1,5
44330 18 83 31,2 ta 70/B 1,5
44331 24 63 43,3 ta 70/B 1,5
44332 2 x 6 125 2 x 10,1 ta 70/B 1,5
44333 2 x 9 83 2 x 15,3 ta 70/B 1,5
44334 2 x 12 63 2 x 20,2 ta 70/B 1,5
44335 2 x 15 50 2 x 25,0 ta 70/B 1,5
44336* 2 x 18 42 2 x 31 ta 70/B 1,5
44337* 2 x 24 31 2 x 43 ta 70/B 1,5
44830 6 300 10,1 ta 70/B 1,8
44831 9 200 15,2 ta 70/B 1,8
44832 12 150 20,3 ta 70/B 1,8
44833 15 120 27,3 ta 70/B 1,8
44834 18 100 30,4 ta 70/B 1,8
44835 24 75 40,6 ta 70/B 1,8
44836 2 x 6 2 x 150 2 x 10,1 ta 70/B 1,8
44837 2 x 9 2 x 100 2 x 15,2 ta 70/B 1,8
44838 2 x 12 2 x 75 2 x 20,3 ta 70/B 1,8
44839* 2 x 15 2 x 60 2 x 27,3 ta 70/B 1,8
PRIMARY VOLTAGE
117 V
1,5-1,8 VA EI 30-12,5
SERIE 44000
Protection
Reference
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
80 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Inherently short-circuits proof
30 V model is VDE EN 61558-2-6 certified
(production on request)
67 910
51
(Allows the use of a transformer
with 2 secondary windings)
79
51
67 910
51
Recommended layout for transformers
with 1 secondary winding
Primary winding
2 Secondary windings
1 Secondary winding
Primary winding
QUALITY IN SERIES
44000 SERIES
ENCAPSULATED TRANSFORMERS
8
44097 6 250 9,7 T 70 B 1,5
44098 9 167 14,5 T 70 B 1,5
44099 12 125 19,3 T 70 B 1,5
44100 15 100 24,2 T 70 B 1,5
44101 18 83 29,8 T 70 B 1,5
44102 24 63 38,6 T 70 B 1,5
44103 2 X 6 2 x 125 2 x 9,7 T 70 B 1,5
44104 2 x 9 2 x 83 2 x 15 T 70 B 1,5
44105 2 x 12 2 x 63 2 x 19,3 T 70 B 1,5
44106 2 x 15 2 x 50 2 x 24,2 T 70 B 1,5
44107 2 x 18 2 x 42 2 x 29 T 70 B 1,5
44108 2 x 24 2 x 31 2 x 38,6 T 70 B 1,5
44726 6 283 9,8 T 50 B 1,7
44727 9 189 14,8 T 50 B 1,7
44728 12 142 19,7 T 50 B 1,7
44729 15 113 24,6 T 50 B 1,7
44730 18 94 30,3 T 50 B 1,7
44731 24 71 39,3 T 50 B 1,7
44732 2 x 6 2 x 142 2 x 9,8 T 50 B 1,7
44733 2 x 9 2 x 94 2 x 15,2 T 50 B 1,7
44734 2 x 12 2 x 71 2 x 19,7 T 50 B 1,7
44735 2 x 15 2 x 57 2 x 24,6 T 50 B 1,7
44736 2 x 18 2 x 47 2 x 29,5 T 50 B 1,7
44737 2 x 24 2 x 35 2 x 39,3 T 50 B 1,7
44738 6 300 9,8 T 40 B 1,8
44739 9 200 14,8 T 40 B 1,8
44740 12 150 19,7 T 40 B 1,8
44741 15 120 24,6 T 40 B 1,8
44742 18 100 30,3 T 40 B 1,8
44743 24 75 39,3 T 40 B 1,8
44744 2 x 6 2 x 150 2 x 9,8 T 40 B 1,8
44745 2 x 9 2 x 100 2 x 15,2 T 40 B 1,8
44746 2 x 12 2 x 75 2 x 19,7 T 40 B 1,8
44747 2 x 15 2 x 60 2 x 24,6 T 40 B 1,8
44748 2 x 18 2 x 50 2 x 29,5 T 40 B 1,8
44749 2 x 24 2 x 38 2 x 39,3 T 40 B 1,8
PRIMARY VOLTAGE
230 V
1,5-1,8 VA EI 30-12,5
SERIE 44000
Protection
Reference
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 18 V and 2 x 24 V models are non-
approved.
Those transformers meet all requirement of EN 61558-2-4
Items usually available on stock
EN 61558-2-6 EN 60950 UL 1585
44000 SERIES
ENCAPSULATED TRANSFORMERS
9
440856 250 9,7 T 70 B 1,5
440869 167 14,5 T 70 B 1,5
4408712 125 19,3 T 70 B 1,5
4408815 100 24,2 T 70 B 1,5
4408918 83 29,8 T 70 B 1,5
4409024 63 38,6 T 70 B 1,5
440912 X 6 2 x 125 2 x 9,7 T 70 B 1,5
440922 x 9 2 x 83 2 x 15 T 70 B 1,5
440932 x 12 2 x 63 2 x 19,3 T 70 B 1,5
440942 x 15 2 x 50 2 x 24,2 T 70 B 1,5
44095*2 x 18 2 x 42 2 x 29 T 70 B 1,5
44096*2 x 24 2 x 31 2 x 38,6 T 70 B 1,5
44647 6 283 9,8 T 50 B 1,7
44648 9 189 14,8 T 50 B 1,7
44649 12 142 19,7 T 50 B 1,7
44650 15 113 24,6 T 50 B 1,7
44651 18 94 30,3 T 50 B 1,7
44652 24 71 39,3 T 50 B 1,7
44653 2 x 6 2 x 142 2 x 9,8 T 50 B 1,7
44654 2 x 9 2 x 94 2 x 15,2 T 50 B 1,7
44655 2 x 12 2 x 71 2 x 19,7 T 50 B 1,7
44656 2 x 15 2 x 57 2 x 24,6 T 50 B 1,7
44483* 2 x 18 2 x 47 2 x 29,5 T 50 B 1,7
44484* 2 x 24 2 x 35 2 x 39,3 T 50 B 1,7
44657 6 300 9,8 T 40 B 1,8
44658 9 200 14,8 T 40 B 1,8
44659 12 150 19,7 T 40 B 1,8
44660 15 120 24,6 T 40 B 1,8
44661 18 100 30,3 T 40 B 1,8
44662 24 75 39,3 T 40 B 1,8
44663 2 x 6 2 x 150 2 x 9,8 T 40 B 1,8
44664 2 x 9 2 x 100 2 x 15,2 T 40 B 1,8
44665 2 x 12 2 x 75 2 x 19,7 T 40 B 1,8
44666 2 x 15 2 x 60 2 x 24,6 T 40 B 1,8
44485* 2 x 18 2 x 50 2 x 29,5 T 40 B 1,8
44486* 2 x 24 2 x 38 2 x 39,3 T 40 B 1,8
PRIMARY VOLTAGE
117 V
Secondary
current
m A
Reference
Protection
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
No-load
voltage
V
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
100 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Inherently short-circuits proof
30 V model is VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
(Allows the use of a transformer
with 2 secondary windings)
79
51
67 910
51
Recommended layout for transformers
with 1 secondary winding
Primary winding
2 Secondary windings
1 Secondary winding
Primary winding
44133 6 333 10,4 T 70 B 2
44134 9 222 15,5 T 70 B 2
44135 12 167 20,7 T 70 B 2
44136 15 133 25,8 T 70 B 2
44137 18 111 30,8 T 70 B 2
44138 24 83 41,4 T 70 B 2
44139 2 X 6 2 x 167 2 x 10,4 T 70 B 2
44140 2 x 9 2 x 111 2 x 15,4 T 70 B 2
44141 2 x 12 2 x 83 2 x 20,7 T 70 B 2
44142 2 x 15 2 x 67 2 x 25,8 T 70 B 2
44143 2 x 18 2 x 56 2 x 30,8 T 70 B 2
44144 2 x 24 2 x 42 2 x 41,4 T 70 B 2
44750 6 383 10,5 T 50 B 2,3
44751 9 256 15,5 T 50 B 2,3
44752 12 192 21 T 50 B 2,3
44753 15 153 25,3 T 50 B 2,3
44754 18 128 31 T 50 B 2,3
44755 24 96 42 T 50 B 2,3
44756 2 x 6 2 x 192 2 x 10,5 T 50 B 2,3
44757 2 x 9 2 x 128 2 x 15,5 T 50 B 2,3
44758 2 x 12 2 x 96 2 x 21 T 50 B 2,3
44759 2 x 15 2 x 77 2 x 24,5 T 50 B 2,3
44760 2 x 18 2 x 64 2 x 31 T 50 B 2,3
44761 2 x 24 2 x 48 2 x 42 T 50 B 2,3
44762 6 400 10,5 T 40 B 2,4
44763 9 267 15,5 T 40 B 2,4
44764 12 200 21 T 40 B 2,4
44765 15 160 25,3 T 40 B 2,4
44766 18 133 31 T 40 B 2,4
44767 24 100 42 T 40 B 2,4
44768 2 x 6 2 x 200 2 x 10,5 T 40 B 2,4
44769 2 x 9 2 x 133 2 x 15,5 T 40 B 2,4
44770 2 x 12 2 x 100 2 x 21 T 40 B 2,4
44771 2 x 15 2 x 80 2 x 24,5 T 40 B 2,4
44772 2 x 18 2 x 67 2 x 31 T 40 B 2,4
44773 2 x 24 2 x 50 2 x 42 T 40 B 2,4
2-2,4 VA EI 30-15,5
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
10
PRIMARY VOLTAGE
230 V
Reference
Protection
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 18 V and 2 x 24 V models are non-
approved.
Those transformers meet all requirement of EN 61558-2-4
Items usually available on stock
EN 61558-2-6 EN 60950 UL 1585 441216 333 10,4 T 70 B 2
441229 222 15,5 T 70 B 2
4412312 167 20,7 T 70 B 2
4412415 133 25,8 T 70 B 2
4412518 111 30,8 T 70 B 2
4412624 83 41,4 T 70 B 2
441272 X 6 2 x 167 2 x 10,4 T 70 B 2
441282 x 9 2 x 111 2 x 15,4 T 70 B 2
441292 x 12 2 x 83 2 x 20,7 T 70 B 2
441302 x 15 2 x 67 2 x 25,8 T 70 B 2
44131*2 x 18 2 x 56 2 x 30,8 T 70 B 2
44132*2 x 24 2 x 42 2 x 41,4 T 70 B 2
44667 6 383 10,5 T 50 B 2,3
44668 9 256 15,5 T 50 B 2,3
44669 12 192 21 T 50 B 2,3
44670 15 153 25,3 T 50 B 2,3
44671 18 128 31 T 50 B 2,3
44672 24 96 42 T 50 B 2,3
44673 2 x 6 2 x 192 2 x 10,5 T 50 B 2,3
44674 2 x 9 2 x 128 2 x 15,5 T 50 B 2,3
44675 2 x 12 2 x 96 2 x 21 T 50 B 2,3
44676 2 x 15 2 x 77 2 x 24,5 T 50 B 2,3
44487* 2 x 18 2 x 64 2 x 31 T 50 B 2,3
44488* 2 x 24 2 x 48 2 x 42 T 50 B 2,3
44677 6 400 10,5 T 40 B 2,4
44678 9 267 15,5 T 40 B 2,4
44679 12 200 21 T 40 B 2,4
44680 15 160 25,3 T 40 B 2,4
44681 18 133 31 T 40 B 2,4
44682 24 100 42 T 40 B 2,4
44683 2 x 6 2 x 200 2 x 10,5 T 40 B 2,4
44684 2 x 9 2 x 133 2 x 15,5 T 40 B 2,4
44685 2 x 12 2 x 100 2 x 21 T 40 B 2,4
44686 2 x 15 2 x 80 2 x 24,5 T 40 B 2,4
44489* 2 x 18 2 x 67 2 x 31 T 40 B 2,4
44490* 2 x 24 2 x 50 2 x 42 T 40 B 2,4
2-2,4 VA EI 30-15,5
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
11
67 910
51
(Allows the use of a transformer
with 2 secondary windings)
79
51
67 910
51
Recommended layout for transformers
with 1 secondary winding
Primary winding
2 Secondary windings
1 Secondary winding
Primary winding
PRIMARY VOLTAGE
117 V
Reference
Protection
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
70 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Inherently short-circuits proof
30 V model is VDE EN 61558-2-6 certified
(production on request)
44169 6 383 10,5 T 70 B 2,3
44170 9 256 15,7 T 70 B 2,3
44171 12 192 21 T 70 B 2,3
44172 15 153 25,9 T 70 B 2,3
44173 18 128 31,4 T 70 B 2,3
44174 24 96 41,9 T 70 B 2,3
44175 2 X 6 2 x 192 2 x 10,5 T 70 B 2,3
44176 2 x 9 2 x 128 2 x 15,7 T 70 B 2,3
44177 2 x 12 2 x 96 2 x 21 T 70 B 2,3
44178 2 x 15 2 x 77 2 x 25,9 T 70 B 2,3
44179 2 x 18 2 x 64 2 x 31,4 T 70 B 2,3
44180 2 x 24 2 x 48 2 x 41,9 T 70 B 2,3
44774 6 450 10,5 T 50 B 2,7
44775 9 300 15,4 T 50 B 2,7
44776 12 225 21,1 T 50 B 2,7
44777 15 180 26,3 T 50 B 2,7
44778 18 150 30,9 T 50 B 2,7
44779 24 113 42 T 50 B 2,7
44780 2 x 6 2 x 225 2 x 10,5 T 50 B 2,7
44781 2 x 9 2 x 150 2 x 15,4 T 50 B 2,7
44782 2 x 12 2 x 113 2 x 21,1 T 50 B 2,7
44783 2 x 15 2 x 90 2 x 26,3 T 50 B 2,7
44784 2 x 18 2 x 75 2 x 31,5 T 50 B 2,7
44785 2 x 24 2 x 56 2 x 42,1 T 50 B 2,7
44786 6 467 10,5 T 40 B 2,8
44787 9 311 15,4 T 40 B 2,8
44788 12 233 21,1 T 40 B 2,8
44789 15 187 26,3 T 40 B 2,8
44790 18 156 30,9 T 40 B 2,8
44791 24 117 42,1 T 40 B 2,8
44792 2 x 6 2 x 233 2 x 10,5 T 40 B 2,8
44793 2 x 9 2 x 156 2 x 15,4 T 40 B 2,8
44794 2 x 12 2 x 117 2 x 21,1 T 40 B 2,8
44795 2 x 15 2 x 93 2 x 26,3 T 40 B 2,8
44796 2 x 18 2 x 77 2 x 31,5 T 40 B 2,8
44797 2 x 24 2 x 58 2 x 42,1 T 40 B 2,8
2,3-2,8 VA EI 30-18
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
12
PRIMARY VOLTAGE
230 V
Protection
Reference
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 18 V and 2 x 24 V models are non-
approved.
Those transformers meet all requirement of EN 61558-2-4
Items usually available on stock
EN 61558-2-6 EN 60950 UL 1585
441576 383 10,5 T 70 B 2,3
441589 256 15,7 T 70 B 2,3
4415912 192 21 T 70 B 2,3
4416015 153 25,9 T 70 B 2,3
4416118 128 31,4 T 70 B 2,3
4416224 96 41,9 T 70 B 2,3
441632 X 6 2 x 192 2 x 10,5 T 70 B 2,3
441642 x 9 2 x 128 2 x 15,7 T 70 B 2,3
441652 x 12 2 x 96 2 x 21 T 70 B 2,3
441662 x 15 2 x 77 2 x 25,9 T 70 B 2,3
44167*2 x 18 2 x 64 2 x 31,4 T 70 B 2,3
44168*2 x 24 2 x 48 2 x 41,9 T 70 B 2,3
44687 6 450 10,5 T 50 B 2,7
44688 9 300 15,4 T 50 B 2,7
44689 12 225 21,1 T 50 B 2,7
44690 15 180 26,3 T 50 B 2,7
44691 18 150 30,9 T 50 B 2,7
44692 24 113 42 T 50 B 2,7
44693 2 x 6 2 x 225 2 x 10,5 T 50 B 2,7
44694 2 x 9 2 x 150 2 x 15,4 T 50 B 2,7
44695 2 x 12 2 x 113 2 x 21,1 T 50 B 2,7
44696 2 x 15 2 x 90 2 x 26,3 T 50 B 2,7
44491* 2 x 18 2 x 75 2 x 31,5 T 50 B 2,7
44492* 2 x 24 2 x 56 2 x 42,1 T 50 B 2,7
44697 6 467 10,5 T 40 B 2,8
44698 9 311 15,4 T 40 B 2,8
44699 12 233 21,1 T 40 B 2,8
44700 15 187 26,3 T 40 B 2,8
44701 18 156 30,9 T 40 B 2,8
44702 24 117 42,1 T 40 B 2,8
44703 2 x 6 2 x 233 2 x 10,5 T 40 B 2,8
44704 2 x 9 2 x 156 2 x 15,4 T 40 B 2,8
44705 2 x 12 2 x 117 2 x 21,1 T 40 B 2,8
44706 2 x 15 2 x 93 2 x 26,3 T 40 B 2,8
44493* 2 x 18 2 x 70 2 x 31,5 T 40 B 2,8
44494* 2 x 24 2 x 58 2 x 42,1 T 40 B 2,8
44000 SERIES
ENCAPSULATED TRANSFORMERS
13
2,3-2,8 VA EI 30-18
SERIE 44000
PRIMARY VOLTAGE
117 V
PRIMARY VOLTAGE
117 V
800 44241 6 833 8,4 T 50 B 5
630 44242 9 556 12,6 T 50 B 5
400 44243 12 417 16,9 T 50 B 5
315 44244 15 333 21 T 50 B 5
315 44245 18 278 25,3 T 50 B 5
200 44246 24 208 33,7 T 50 B 5
400 44247 2 x 6 2 x 417 2 x 8,4 T 50 B 5
315 44248 2 x 9 2 x 278 2 x 12,6 T 50 B 5
200 44249 2 x 12 2 x 208 2 x 16,9 T 50 B 5
160 44250 2 x 15 2 x 167 2 x 21 T 50 B 5
160 44251 2 x 18 2 x 139 2 x 25,3 T 50 B 5
100 44252 2 x 24 2 x 104 2 x 33,7 T 50 B 5
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
150 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Fuse protection on secondary side (see diagram) to be assumed
by customer
67 910
51
51
51
6
10
79 6
10
79
Recommended layout
for transformers with
1 secondary winding
(Allows the use of a
transformer with
2 secondary windings)
2 Secondary windings 1 Secondary winding
Primary Primary
winding winding
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
200 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Fuse protection on secondary side (see diagram) to be assumed
by customer
67 910
51
51
51
6
10
79 6
10
79
Recommended layout
for transformers with
1 secondary winding
(Allows the use of a
transformer with
2 secondary windings)
2 Secondary windings 1 Secondary winding
Primary Primary
winding winding
Secondary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Secondary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
3,2 VA EI 38-13,6
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
14
5 VA EI 42-14,8
SERIE 44000
630 44205 6 533 8 T 70 B 3,2
400 44206 9 356 12 T 70 B 3,2
315 44207 12 267 16 T 70 B 3,2
250 44208 15 213 20 T 70 B 3,2
200 44209 18 178 24,1 T 70 B 3,2
160 44210 24 133 32,1 T 70 B 3,2
315 44211 2 x 6 2 x 267 2 x 8 T 70 B 3,2
200 44212 2 x 9 2 x 178 2 x 12 T 70 B 3,2
160 44213 2 x 12 2 x 133 2 x 16 T 70 B 3,2
125 44214 2 x 15 2 x 107 2 x 20 T 70 B 3,2
100 44215 2 x 18 2 x 89 2 x 24 T 70 B 3,2
80 44216 2 x 24 2 x 67 2 x 32,1 T 70 B 3,2
PRIMARY VOLTAGE
230 V
PRIMARY VOLTAGE
230 V
Secondary
protection
mA
Secondary
protection
mA
4.5+0.5
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
5+0.5
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
EN 61558-2-6 EN 60950
EN 61558-2-6 EN 60950
44000 SERIES
ENCAPSULATED TRANSFORMERS
15
3,2 VA EI 38-13,6
SERIE 44000
5 VA EI 42-14,8
SERIE 44000
630 44193 6 533 8 T 70 B 3,2
400 44194 9 356 12 T 70 B 3,2
315 44195 12 267 16 T 70 B 3,2
250 44196 15 213 20 T 70 B 3,2
200 44197 18 178 24,1 T 70 B 3,2
160 44198 24 133 32,1 T 70 B 3,2
315 44199 2 x 6 2 x 267 2 x 8 T 70 B 3,2
200 44200 2 x 9 2 x 178 2 x 12 T 70 B 3,2
160 44201 2 x 12 2 x 133 2 x 16 T 70 B 3,2
125 44202 2 x 15 2 x 107 2 x 20 T 70 B 3,2
100 44203 2 x 18 2 x 89 2 x 24 T 70 B 3,2
80 44204* 2 x 24 2 x 67 2 x 32,1 T 70 B 3,2
800 44229 6 833 8,4 T 50 B 5
630 44230 9 556 12,6 T 50 B 5
400 44231 12 417 16,9 T 50 B 5
315 44232 15 333 21 T 50 B 5
315 44233 18 278 25,3 T 50 B 5
200 44234 24 208 33,7 T 50 B 5
400 44235 2 x 6 2 x 417 2 x 8,4 T 50 B 5
315 44236 2 x 9 2 x 278 2 x 12,6 T 50 B 5
200 44237 2 x 12 2 x 208 2 x 16,9 T 50 B 5
160 44238 2 x 15 2 x 167 2 x 21 T 50 B 5
160 44239 2 x 18 2 x 139 2 x 25,3 T 50 B 5
100 44240* 2 x 24 2 x 104 2 x 33,7 T 50 B 5
PRIMARY VOLTAGE
117 V
PRIMARY VOLTAGE
117 V
2,5 44313 6 2667 7,4 T 50 B 16
2,0 44314 9 1778 11,1 T 50 B 16
1,25 44315 12 1333 14,7 T 50 B 16
1 44316 15 1067 18,4 T 50 B 16
1 44317 18 889 22,1 T 50 B 16
0,63 44318 24 667 29,3 T 50 B 16
1,25 44319 2 x 6 2 x 1333 2 x 7,4 T 50 B 16
1 44320 2 x 9 2 x 889 2 x 11,1 T 50 B 16
0,63 44321 2 x 12 2 x 667 2 x 14,7 T 50 B 16
0,5 44322 2 x 15 2 x 533 2 x 18,4 T 50 B 16
0,5 44323 2 x 18 2 x 444 2 x 22 T 50 B 16
0,315 44324 2 x 24 2 x 333 2 x 29,3 T 50 B 16
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
300 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Fuse protection on primary side (see diagram) to be assumed
by customer
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
400 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Fuse protection on secondary side (see diagram) to be assumed
by customer
Primary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Secondary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
10 VA EI 48-16,8
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
16
16 VA EI 54-18,8
SERIE 44000
125 44277 6 1667 7,2 T 50 B 10
125 44278 9 1111 10,8 T 50 B 10
125 44279 12 833 14,4 T 50 B 10
125 44280 15 667 18,1 T 50 B 10
125 44281 18 556 21,6 T 50 B 10
125 44282 24 417 28,9 T 50 B 10
125 44283 2 x 6 2 x 833 2 x 7,2 T 50 B 10
125 44284 2 x 9 2 x 556 2 x 10,8 T 50 B 10
125 44285 2 x 12 2 x 417 2 x 14,4 T 50 B 10
125 44286 2 x 15 2 x 333 2 x 18,1 T 50 B 10
125 44287 2 x 18 2 x 278 2 x 21,6 T 50 B 10
125 44288 2 x 24 2 x 208 2 x 28,9 T 50 B 10
71
71
71
8 8
14
9
13
9
1413
Recommended layout
for transformers with
1 secondary winding
(Allows the use of a
transformer with
2 secondary windings)
2 Secondary 1 Secondary
windings winding
Primary Primary
winding winding
8 9
13 14
61
61
61
7 7
12
8
11
8
1211
Recommended layout
for transformers with
1 secondary winding
(Allows the use of a
transformer with
2 secondary windings)
2 Secondary 1 Secondary
windings winding
Primary Primary
winding winding
7 8 11 12
PRIMARY VOLTAGE
230 V
PRIMARY VOLTAGE
230 V
Secondary
protection
mA
Primary
protection
mA
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
EN 61558-2-6 EN 60950
EN 61558-2-6 EN 60950
44000 SERIES
ENCAPSULATED TRANSFORMERS
17
10 VA EI 48-16,8
SERIE 44000
16 VA EI 54-18,8
SERIE 44000
63 44265 6 1667 7,2 T 50 B 10
63 44266 9 1111 10,8 T 50 B 10
63 44267 12 833 14,4 T 50 B 10
63 44268 15 667 18,1 T 50 B 10
63 44269 18 556 21,6 T 50 B 10
63 44270 24 417 28,9 T 50 B 10
63 44271 2 x 6 2 x 833 2 x 7,2 T 50 B 10
63 44272 2 x 9 2 x 556 2 x 10,8 T 50 B 10
63 44273 2 x 12 2 x 417 2 x 14,4 T 50 B 10
63 44274 2 x 15 2 x 333 2 x 18,1 T 50 B 10
63 44275 2 x 18 2 x 278 2 x 21,6 T 50 B 10
63 44276* 2 x 24 2 x 208 2 x 28,9 T 50 B 10
2,500 44301 6 2667 7,4 T 50 B 16
2,000 44302 9 1778 11,1 T 50 B 16
1,25 44303 12 1333 14,7 T 50 B 16
1 44304 15 1067 18,4 T 50 B 16
1 44305 18 889 22,1 T 50 B 16
0,63 44306 24 667 29,3 T 50 B 16
1,25 44307 2 x 6 2 x 1333 2 x 7,4 T 50 B 16
1 44308 2 x 9 2 x 889 2 x 11,1 T 50 B 16
0,63 44309 2 x 12 2 x 667 2 x 14,7 T 50 B 16
0,5 44310 2 x 15 2 x 533 2 x 18,4 T 50 B 16
0,5 44311 2 x 18 2 x 444 2 x 22 T 50 B 16
0,315 44312* 2 x 24 2 x 333 2 x 29,3 T 50 B 16
3.5+0.5
PRIMARY VOLTAGE
117 V
PRIMARY VOLTAGE
117 V
315 44385 6 5000 6,9 T 50 B 30
315 44386 9 3333 10,3 T 50 B 30
315 44387 12 2500 13,8 T 50 B 30
315 44388 15 2000 17,2 T 50 B 30
315 44389 18 1667 20,8 T 50 B 30
315 44390 24 1250 27,7 T 50 B 30
315 44391 2 x 6 2 x 2500 2 x 6,9 T 50 B 30
315 44392 2 x 9 2 x 1667 2 x 10,3 T 50 B 30
315 44393 2 x 12 2 x 1250 2 x 13,8 T 50 B 30
315 44394 2 x 15 2 x 1000 2 x 17,2 T 50 B 30
315 44395 2 x 18 2 x 833 2 x 20,8 T 50 B 30
315 44396 2 x 24 2 x 625 2 x 27,7 T 50 B 30
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
550 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Fuse protection on primary side (see diagram) to be assumed
by customer
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
700 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Fuse protection on primary side (see diagram) to be assumed
by customer
Primary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Primary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
22 VA EI 60-21
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
18
30 VA EI 66-23
SERIE 44000
250 44444 6 3667 6,8 T 50 B 22
250 44445 9 2444 10,3 T 50 B 22
250 44446 12 1833 13,7 T 50 B 22
250 44447 15 1467 17,1 T 50 B 22
250 44448 18 1222 20,5 T 50 B 22
250 44449 24 917 27,3 T 50 B 22
250 44450 2 x 6 2 x 1833 2 x 6,8 T 50 B 22
250 44451 2 x 9 2 x 1222 2 x 10,3 T 50 B 22
250 44452 2 x 12 2 x 917 2 x 13,7 T 50 B 22
250 44453 2 x 15 2 x 733 2 x 17,1 T 50 B 22
250 44454 2 x 18 2 x 611 2 x 20,5 T 50 B 22
250 44455 2 x 24 2 x 458 2 x 27,3 T 50 B 22
89
13 14
71
71
71
8
13
9
14
8
13
9
14
Recommended layout
for transformers
with 1 secondary winding
(Allows the use of a
transformer with 2 secondary
windings)
2 Secondary 1 Secondary
windings winding
Primary Primary
winding winding
81
81
81
9 9
1615161510 10
Recommended layout
for transformers
with 1 secondary winding
(Allows the use of a
transformer with 2 secondary
windings)
2 Secondary 1 Secondary
windings winding
Primary Primary
winding winding
9
10 15 16
PRIMARY VOLTAGE
230 V
PRIMARY VOLTAGE
230 V
Primary
protection
mA
Primary
protection
mA
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
EN 61558-2-6 EN 60950
EN 61558-2-6 EN 60950
44000 SERIES
ENCAPSULATED TRANSFORMERS
19
22 VA EI 60-21
SERIE 44000
30 VA EI 66-23
SERIE 44000
125 44432 6 3667 6,8 T 50 B 22
125 44433 9 2444 10,3 T 50 B 22
125 44434 12 1833 13,7 T 50 B 22
125 44435 15 1467 17,1 T 50 B 22
125 44436 18 1222 20,5 T 50 B 22
125 44437 24 917 27,3 T 50 B 22
125 44438 2 x 6 2 x 1833 2 x 6,8 T 50 B 22
125 44439 2 x 9 2 x 1222 2 x 10,3 T 50 B 22
125 44440 2 x 12 2 x 917 2 x 13,7 T 50 B 22
125 44441 2 x 15 2 x 733 2 x 17,1 T 50 B 22
125 44442 2 x 18 2 x 611 2 x 20,5 T 50 B 22
125 44443* 2 x 24 2 x 458 2 x 27,3 T 50 B 22
160 44373 6 5000 6,9 T 50 B 30
160 44374 9 3333 10,3 T 50 B 30
160 44375 12 2500 13,8 T 50 B 30
160 44376 15 2000 17,2 T 50 B 30
160 44377 18 1667 20,8 T 50 B 30
160 44378 24 1250 27,7 T 50 B 30
160 44379 2 x 6 2 x 2500 2 x 6,9 T 50 B 30
160 44380 2 x 9 2 x 1667 2 x 10,3 T 50 B 30
160 44381 2 x 12 2 x 1250 2 x 13,8 T 50 B 30
160 44382 2 x 15 2 x 1000 2 x 17,2 T 50 B 30
160 44383 2 x 18 2 x 833 2 x 20,8 T 50 B 30
160 44384* 2 x 24 2 x 625 2 x 27,7 T 50 B 30
For boxes with 2 lugs and pin type output, add suffix 1 to the reference of the standard transformer (example : 44198-1)
For boxes with 2 lugs and 2,8 «faston» output, add suffix 2 to the reference of the standard transformer (example : 44199-2)
For boxes with 4 lugs and pin type output, add suffix 3 to the reference of the standard transformer (example : 44200-3)
For boxes with 4 lugs and 2,8 «faston» output, add suffix 4 to the reference of the standard transformer (example : 44201-4)
These models are not available on stock.
Series 44000 transformers can be
equiped with boxes with lugs and also
2,8 «faston» terminal tags while still
conforming to the specifications in
the standard references.
•••••••
••
•••••
X
LHLH
P
P
O
Y
OX
••••••••
••••••••
••••••
7X5.0
1
16
8
9
7X5.0
1
14
7
8
6X5.0
6X5.0
•••••
1
10
5
6
4X5.0
5X5.0
•••••
••
1
14
7
8
13X2.5
••••••
••••••
5X5.0
1
12
6
7
11X2.5
••
1
10
5
6
7.5
5X5.0
7.5
5.0 5.0
6X5.0
EI 38 EI 42 EI 48
EI 54 EI 60 EI 66
BOXES WITH FIXING SUPPORT
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
20
CIRCUIT LPHXYØ
± 0,50 ± 0,40 ± 0,40 ± 0,50 ± 0,50 ±0,3
EI 38 X 13,6 55,6 34,9 28,1 47,5 3,2
EI 42 X 14,8 64 37 32,3 55,0 4,2
EI 48 X 16,8 69 42,3 34,6 60 4,2
EI 54 X 18,8 74 47,3 38,8 65 4,2
EI 60 X 21 81,5 53,3 44,7 72,5 43,5 4,2
EI 66 X 23 87,2 58,6 48,5 77,5 47,5 4,2
PRIMARY VOLTAGE
230 V
Reference
Protection
45000 SERIES
ENCAPSULATED TRANSFORMERS
21
1 VA UI 21
SERIE 45000
Ambient
Temperature
°C
Secondary
voltage
V
No-load
voltage
V
Secondary
current
m A
UI 21 230 V 1 VA
230 V supply voltage by series/parallel
connection
Vacuum filling
One compartiment housing 1 VA
Two compartments bobbins 0,8 VA
Degree of protection IP 00
50 grams weight
Resin UL 94 VO
Design protection against short-circuits
Insulation voltage 4 KV
100 % tested production
Conform to EN 61558 - UL 506
1 VA
Type 1 VA
Primary
windings
Secondary
windings
25
12 7
QUALITY IN SERIES
45001 6 167 11,4 T 70 B
45002 9 111 17 T 70 B
45003 12 83 22,8 T 70 B
45004 15 67 28,5 T 70 B
45005 18 56 34,2 T 70 B
45006 24 42 45,6 T 70 B
PRIMARY VOLTAGE
115 V - 230 V •115 V- 230 V supply voltage
by series/parallel connection
Vacuum filling
Two compartments bobbins
Degree of protection IP 00
Resin class UL 94 VO
Ambient
Temperature
°C
No-load
voltage
V
Protection
Secondary
voltage
V
Secondary
current
m A
Reference
UI 30 x 5,5 2 VA
45292 2 x 6 2 x 167 2 x 10,2 T 70 B
45293 2 x 9 2 x 111 2 x 15,9 T 70 B
45294 2 x12 2 x 83 2 x 20,4 T 70 B
45295 2 x15 2 x 67 2 x 25,5 T 70 B
45296 2 x18 2 x 56 2 x 30,6 T 70 B
45297 2 x24 2 x 42 2 x 40,8 T 70 B
UI 30 x 5,5 Secondary protection mA 3 VA
250 45013 2 x 6 2 x 250 2 x 9,8 T 70 B
160 45014 2 x 9 2 x 167 2 x 14,7 T 70 B
125 45015 2 x 12 2 x 125 2 x 19,6 T 70 B
100 45016 2 x 15 2 x 100 2 x 24,5 T 70 B
80 45017 2 x 18 2 x 83 2 x 29,5 T 70 B
63 45018 2 x 24 2 x 63 2 x 39,3 T 70 B
UI 30 x 7,5 Secondary protection mA 4 VA
315 45019 2 x 6 2 x 333 2 x 9,4 T 70 B
250 45020 2 x 9 2 x 222 2 x 14,0 T 70 B
160 45021 2 x 12 2 x 167 2 x 18,6 T 70 B
125 45022 2 x 15 2 x 133 2 x 23,3 T 70 B
125 45023 2 x 18 2 x 111 2 x 28,0 T 70 B
80 45024 2 x 24 2 x 83 2 x 37,4 T 70 B
UI 30 x 10,5 Secondary protection mA 6 VA
500 45025 2 x 6 2 x 500 2 x 8,1 T 70 B
315 45026 2 x 9 2 x 333 2 x 12,1 T 70 B
250 45027 2 x 12 2 x 250 2 x 16,2 T 70 B
200 45028 2 x 15 2 x 200 2 x 20,2 T 70 B
160 45029 2 x 18 2 x 167 2 x 24,3 T 70 B
125 45030 2 x 24 2 x 125 2 x 32,3 T 70 B
UI 30 x 16,5 Primary protection mA 10 VA
125/63 45031 2 x 6 2 x 833 2 x 7,9 T 50 B
125/63 45032 2 x 9 2 x 556 2 x 11,9 T 50 B
125/63 45033 2 x 12 2 x 417 2 x 15,9 T 50 B
125/63 45034 2 x 15 2 x 333 2 x 19,8 T 50 B
125/63 45035 2 x 18 2 x 278 2 x 23,7 T 50 B
125/63 45036 2 x 24 2 x 208 2 x 31,7 T 50 B
CIRCUIT RATING
DIMENSION A
WEIGHT
UI 30 x 5,5 2 VA/3 VA A = 17 mm 125 g
UI 30 x 7,5 4 VA A = 19 mm 150 g
UI 30 x 10,5 6 VA A = 22 mm 185 g
UI 30 x 16,5 10 VA A = 28 mm 260 g
1357
16 14 12 10
1357
16 14 12 10
1357
16 14 12 10
1357
16 14 12 10
Secondary voltage Double the
doubled secondary current
Possible primary
connections
Possible secondary
connections
230 V 115 V
3-10 VA UI 30
SERIE 45000
45000 SERIES
ENCAPSULATED TRANSFORMERS
22
QUALITY IN SERIES
PRIMARY VOLTAGE
115 V - 230 V
Reference
Ambient
Temperature
°C
No-load
voltage
V
Secondary
current
m A
Secondary
voltage
V
Primary
protection
115 V/230 V
mA
UI 39 x 8 10 VA
125/63 45037 2 x 6 2 x 833 2 x 8,2 T 50 B
125/63 45038 2 x 9 2 x 555 2 x 12,3 T 50 B
125/63 45039 2 x 12 2 x 416 2 x 16,4 T 50 B
125/63 45040 2 x 15 2 x 333 2 x 20,5 T 50 B
125/63 45041 2 x 18 2 x 277 2 x 24,6 T 50 B
125/63 45042 2 x 24 2 x 208 2 x 32,8 T 50 B
UI 39 x 10,2 14 VA
160/80 45043 2 x 6 2 x 1167 2 x 7,5 T 50 B
160/80 45044 2 x 9 2 x 778 2 x 10,9 T 50 B
160/80 45045 2 x 12 2 x 583 2 x 15,0 T 50 B
160/80 45046 2 x 15 2 x 467 2 x 18,7 T 50 B
160/80 45047 2 x 18 2 x 389 2 x 22,4 T 50 B
160/80 45048 2 x 24 2 x 292 2 x 30,2 T 50 B
UI 39 x 13,5 18 VA
200/100 45049 2 x 6 2 x 1500 2 x 7,4 T 50 B
200/100 45050 2 x 9 2 x 1000 2 x 11,0 T 50 B
200/100 45051 2 x 12 2 x 750 2 x 14,7 T 50 B
200/100 45052 2 x 15 2 x 600 2 x 18,3 T 50 B
200/100 45053 2 x 18 2 x 500 2 x 22,0 T 50 B
200/100 45054 2 x 24 2 x 375 2 x 29,4 T 50 B
UI 39 x 17 24 VA
250/125 45055 2 x 6 2 x 2000 2 x 7,1 T 50 B
250/125 45056 2 x 9 2 x 1333 2 x 10,6 T 50 B
250/125 45057 2 x 12 2 x 1000 2 x 14,1 T 50 B
250/125 45058 2 x 15 2 x 800 2 x 17,6 T 50 B
250/125 45059 2 x 18 2 x 667 2 x 21,2 T 50 B
250/125 45060 2 x 24 2 x 500 2 x 28,3 T 50 B
UI 39 x 21 30 VA
315/160 45061 2 x 6 2 x 2500 2 x 6,7 T 50 B
315/160 45062 2 x 9 2 x 1667 2 x 10,15 T 50 B
315/160 45063 2 x 12 2 x 1250 2 x 13,5 T 50 B
315/160 45064 2 x 15 2 x 1000 2 x 16,8 T 50 B
315/160 45065 2 x 18 2 x 833 2 x 20,2 T 50 B
315/160 45066 2 x 24 2 x 625 2 x 27,0 T 50 B
Fuse protection in secondary winding (see diagram)
Insulation voltage 4 KV
100 % tested production
Conform to EN 61558
Approval under process
UL 506 approved
CIRCUIT RATING
DIMENSION A
WEIGHT
UI 39 x 8 10 VA A = 22 mm 285 g
UI 39 x 10,2 14 VA A = 24 mm 335 g
UI 39 x 13,5 18 VA A = 27 mm 405 g
UI 39 x 17 24 VA A = 31 mm 480 g
UI 39 x 21 30 VA A = 35 mm 550 g
1469
19 17 14 12
1469
19 17 14 12
1469
19 17 14 12
1469
19 17 14 12
Secondary voltage Double the
doubled secondary current
sec 1 sec 2 sec 1 sec 2
Possible primary
connections
Possible secondary
connections
230 V 115 V
45000 SERIES
ENCAPSULATED TRANSFORMERS
23
10-30 VA UI 39
SERIE 45000
PRIMARY VOLTAGE
115 V - 230 V
115 V- 230 V supply voltage
by series/parallel connection
Vacuum filling
Two compartments bobbins
Degree of protection IP 00
Resin class UL 94 VO
Fuse protection in secondary winding (see diagram)
Insulation voltage 4 KV
100 % tested production
Conform to EN 61558
Approval under process
UL 506 approved
CIRCUIT RATING AB C WEIGHT
UI 48 x 17 40 VA 38,5 13,5 83 760 g
UI 48 x 26 60 VA 48,5 14,5 86 1060 g
14 9
23 20 17
12
14
14 9
12
14 9
12
14 9
12
23 20 17 14 23 20 17 14 23 20 17 14
Secondary voltage Double the
doubled secondary current
Possible primary
connections
Possible secondary
connections
230 V 115 V
Primary
protection
115/230 V
mA
Reference
No-load
voltage
V
Secondary
voltage
V
Secondary
current
m A
Ambient
Temperature
°C
400/200 45067 2 x 6 2 x 3333 2 x 6,7 T 50 B
400/200 45068 2 x 9 2 x 2222 2 x 10,0 T 50 B
400/200 45069 2 x 12 2 x 1667 2 x 13,4 T 50 B
400/200 45070 2 x 15 2 x 1333 2 x 16,7 T 50 B
400/200 45071 2 x 18 2 x 1111 2 x 20,1 T 50 B
400/200 45072 2 x 24 2 x 833 2 x 26,8 T 50 B
630/315 45073 2 x 6 2 x 5000 2 x 6,6 T 50 B
630/315 45074 2 x 9 2 x 3333 2 x 9,9 T 50 B
630/315 45075 2 x 12 2 x 2500 2 x 13,1 T 50 B
630/315 45076 2 x 15 2 x 2000 2 x 16,4 T 50 B
630/315 45077 2 x 18 2 x 1667 2 x 19,7 T 50 B
630/315 45078 2 x 24 2 x 1250 2 x 26,3 T 50 B
U I 48 x 17 40 VA
U I 48 x 26 60 VA
40-60 VA UI 48
SERIE 45000
45000 SERIES
ENCAPSULATED TRANSFORMERS
24
QUALITY IN SERIES
FLF SERIES : connection by UL-approved flexible
cables (600 V/105°C)
AWG 18 up to 6 A
AWG 16 up to 10 A
}
standard length :
AWG 14 up to 20 A 250 mm
FLC SERIES : connection by «faston» connectors
Rating primary secondary
3,2 VA-5 VA 2,8 x 0,8 4,8 x 0,8
10 VA-22 VA 4,8 x 0,8 4,8 x 0,8
30 VA-240 VA 6,3 x 0,8 6,3 x 0,8
* Transformer not complying with the standard (for this, it must be equiped with a thermal fuse system)
Primary
winding
Secondary
winding
A
D
Ø
F
E
C
B
Primary winding
Secondary winding
A
D
Ø
F
E
C
B
FLF SERIES FLC SERIES
FLF / FLC SERIES
ENCAPSULATED TRANSFORMERS
25
3,2-240 VA
FLF / FLC SERIES
SIDE-MOUNTING TRANSFORMERS
FLF / FLC SERIES
Primary voltage : 230 V 50/60 Hz
Secondary voltage : 12 V ou 24 V
Maximum ambient temperature : + 40 °C
Insulation class : B
Insulation voltage : 4 kV
Standards applicable : VDE 0570 - EN 61558 -
UL 506
Degree of protection IP 00
Prepared for protection class II
Options : 00 Standard
01 Addition of a thermal fuse
(non-resettable)
02 Addition of a resettable thermal
protection system
On request : all primary and secondary voltages up
to 500 V (consult us for details)
Rating References
Drop Vs-c Effic.
Fuse Format ABCDE FØ
in VA FLF FLC %%%
12 V 24 V 12 V 24 V
3,2 30081 30094 30107 30120 30 28 61 32 mA EI 38 x 13,6 61 33 35 51 - 19,5 3,5
5 30082 30095 30108 30121 32 30 62 32 mA EI 42 x 14,8 65 33 38 55 - 17,8 3,5
10 30083 30096 30109 30122 25 25 69 63 mA EI 48 x 16,8 75 39 43 62 12 9 3,5
16 30084 30097 30110 30123 24 23 71,5 80 mA EI 54 x 18,4 82,5 43 48,5 68 11 11 3,5
22 30085 30098 30111 30124 19 19 76,5 125 mA EI 60 x 21 88 48 53,5 75 13,5 12,2 4,8
30 30086 30099 30112 30125 16 16 79,5 160 mA EI 66 x 23 94 49,5 58,5 82 13 13,3 4,8
45 30087 30100 30113 30126 11 11 83 250 mA EI 66 x 34,7 94 61 58,5 82 37,5 7,4 4,8
63 30088 30101 30114 30127 12 13 83,5 315 mA EI 78 x 27,5 112,5 59 71,5 97,5 32,5 7,6 5,2
100 30089 30102 30115 30128 13,5 15 84,5 500 mA EI 84 x 29,5 120 64 75 102,5 32,5 10,2 5,5
160* 30090 30103 30116 30129 12 13,5 86 800 mA EI 84 x 43,5 120 78 75 102,5 45 10,8 5,5
160 30091 30104 30117 30130 9,5 12 88,5 800 mA EI 96 x 35,7 133 75 85 115 40 10,6 5,5
185 30092 30105 30118 30131 7,8 9,8 90 1,0 A EI 96 x 45,7 133 85 85 115 50 10,6 5,2
240 30093 30106 30119 30132 6,4 8 91 1,25 A EI 96 x 59,7 133 98,5 85 115 64 10,2 5,5
74000 E16 5w 5v 12v
74001 E16 6w 5v
74002 E16 6w 12v
74003 E16 5w 3.3v 5v
74010 E16 12w 5v 12v
74014 E16 12w 24v 24v
74015 E16 12w 5v 15v 24v
74020 EL19 18w 5v 12v
74021 EL19 18w 5v 12v
74023 EL19 16w 3.3v 5v 12v 18v 30v
74030 E25 30w 5v 12v 12v
74032 E25 35w 24v
74040 ETD29 60w 5v 12v 5v 12v
74043 ERL28 60w 3.3v 5v 12v 18v 30v
74050 ETD34 90w 5v 12v 5v 12v
74060 ETD39 140w 5v 12v 5v 12v
74070 ETD44 180w 5v 12v 5v 12v
74080 EF20 24w 12v 12v
74081 EF20 20w 3.3v 5v 12v
74082 EF20 20w 5v 5v
74090 E16 1.5w 5v
74091 E16 1.5w 12v
74092 E16 3.1w 5v
74093 E16 3.1w 12v
74094 E16 9w 5v
74095 E16 9w 12v
Watts
MYRRA
Part
Max.
Output
Power
Vdc nominal voltage
CORE
SIZE
Outputs
Note : “5 volts outputs can generally be used for 3.3 to 6volts; “12 volts” outputs can be used for 9 to 16volts.
See detailed characteristics.
FLYBACK TRANSFORMERS RANGE
for switch mode power supplies
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
26
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
27
TRANSFORMER / CONTROL CIRCUITS
CROSS-REFERENCE LIST
Transformer
Reference
IC
Manufacturer
Series &
References
74090
74091
74092
74093
74094
74095
No aux. Winding PI TNY Series
LNK XT Series
74000
74001
74002
74003
74004
74005
74010
74014
74015
74020
74021
74023
74080
74081
74082
74087
74088
74089
74030
74032
74040
74043
74050
74060
74070
With aux. Winding
ONSEMI
NCP 1014
NCP 3065
etc.
PI TOP Series
LNK Series
NXP
TEA1530
TEA1351
TEA3065
etc.
ST Viper Series
FAIRCHILD
FAN102
FAN400
FSEZ130
FSEZ1213
etc.
ON Bright
OB2535
OB2212
OB2361
etc.
Frequency
Windings
Pin 3 Removed
PCB Drilling Diameter = 1.1mm
Bottom View (Pin side)
0V
+S1
DRAIN
+E
Primary / Secondary Insulation 4000V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 85°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Examples of application with Integrated Circuits :
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
74090 1.5 w Pri 10 9 228 50 95 (VOR) 0.28 Apeak 6000µH
S1 5 2 16 3.3 6 Vdc 0.4 Adc
74091 1.5 w Pri 10 9 228 65 130 (VOR) 0.28 Apeak 6000µH
S1 5 2 28 7.5 15 Vdc 0.2 Adc
74090 Power Integrations 85 - 265Vrms 1.5w 44kHz
74091 Power Integrations 85 - 265Vrms 1.5w 44kHz
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
28
TRANSFORMER FOR TINYSWITCH
SIZE E16 SINGLE OUTPUT : 5 or 12v
Frequency
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
74092 Power Integrations 85 - 265Vrms 3.1w 44kHz
74093 Power Integrations TNY25485 - 265Vrms 3.1w 44kHz
Windings
Pin 3 Removed
PCB Drilling Diameter = 1.1mm
Bottom View (Pin side)
0V
+S1
DRAIN
+E
Primary / Secondary Insulation 4000V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 70°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Examples of application with Integrated Circuits :
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74092 3.1 w Pri 10 9 191 55 100 (VOR) 0.34 Apeak 4200µH
S1 5 2 13 3.3 6 Vdc 0.9 Adc
74093 3.1 w Pri 10 9 191 65 125 (VOR) 0.34 Apeak 4200µH
S1 5 2 24 7.5 15 Vdc 0.4 Adc
TRANSFORMER FOR TINYSWITCH
SIZE E16 SINGLE OUTPUT : 5 or 12v
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
29
Frequency
Windings
Pin 3 Removed
PCB Drilling Diameter = 1.1mm
Bottom View (Pin side)
0V
+S1
DRAIN
+E
Primary / Secondary Insulation 4000V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 60°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Examples of application with Integrated Circuits :
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
74094 9 w Pri 10 9 135 55 100 (VOR) 0.48 Apeak 2100µH
S1 5 2 9 3.3 6 Vdc 1.5 Adc
74095 9 w Pri 10 9 135 65 125 (VOR) 0.48 Apeak 2100µH
S1 5 2 17 7.5 15 Vdc 0.9 Adc
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
30
TRANSFORMER FOR TINYSWITCH
SIZE E16 SINGLE OUTPUT : 5 or 12v
74094 Power Integrations 85 - 265Vrms 4.2w 44kHz
Power Integrations 85 - 265Vrms 5w 132kHz
Power Integrations 85 - 265Vrms 9w 132kHz
74095 Power Integrations 85 - 265Vrms 5w 44kHz
Power Integrations 85 - 265Vrms 5w 132kHz
Power Integrations 85 - 265Vrms 9w 132kHz
Frequency
Windings
PIN 3 Removed
PCB Drilling Diameter = 1.1mm
+S2
0V
+S1
0V
+E
DRAIN
+AUX
0V
Bottom View (Pin side)
74000
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 70°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Examples of application with Integrated Circuits :
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
FLYBACK TRANSFORMER
2 OUTPUTS : 5 & 12v
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
31
74000 5 w Pri 4 - 6 138 62 130 (VOR) 0.27 Apeak 3900µH
Aux 2 - 1 16 7 14 Vdc 0.1 Adc
S1 9 - 10 8 3.3 7 Vdc 1.2 Adc
S2 7 - 8 19 8 17 Vdc 0.4 Adc
74000 Power Integrations 85 - 265Vrms 5w 132kHz
ST Microelectronics 85 - 265Vrms 4w 70kHz
Frequency
Windings
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
32
FLYBACK TRANSFORMER
SIZE E16 SINGLE OUTPUT : 5 or 12v
PIN 3 Removed
PCB Drilling Diameter = 1.1mm
+S1
0V
+E
DRAIN
+AUX
0V
Bottom View (Pin side)
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 60°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Examples of application with Integrated Circuits :
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74001 6 w Pri 4 - 6 138 60 120 (VOR) 0.35 Apeak 3000µH
Aux 2 - 1 20 8 16 Vdc 0.1 Adc
S1 9 - 10 8 3 6 Vdc 1.2 Adc
74002 6 w Pri 4 - 6 150 60 120 (VOR) 0.38 Apeak 3000µH
Aux 2 - 1 22 8.5 17 Vdc 0.1 Adc
S1 9 - 10 24 9 18 Vdc 0.5 Adc
74001 Power Integrations 85 - 265Vrms 6w 132kHz
ST Microelectronics 85 - 265Vrms 6w 70kHz
ST Microelectronics 85 - 265Vrms 3w 40kHz
Motorola 85 - 265Vrms 6w 100kHz
Infineon 185 - 265Vrms 6w 100kHz
74002 Power Integrations 85 - 265Vrms 6w 132kHz
ST Microelectronics 85 - 265Vrms 6w 70kHz
ST Microelectronics 85 - 265Vrms 3w 40kHz
Motorola 85 - 265Vrms 6w 100kHz
Infineon 185 - 265Vrms 6w 100kHz
Frequency
74003 Power Integrations 85 - 265Vrms 5w 132kHz
ST Microelectronics 85 - 265Vrms 6w 70kHz
ST Microelectronics 85 - 265Vrms 3w 40kHz
Motorola 85 - 265Vrms 6w 100kHz
Infineon 185 - 265Vrms 6w 100kHz
Windings
FLYBACK TRANSFORMER
SIZE E16 DUAL OUTPUT : 3.3 + 5v
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
33
PIN 3 Removed
PCB Drilling Diameter = 1.1mm
Bottom View (Pin side)
+S2
+S1
0V
+E
DRAIN
+AUX
0V
74003
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 60°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Examples of application with Integrated Circuits :
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
74003 6 w Pri 4 - 6 120 55 115 (VOR) 0.3 Apeak 3000µH
Aux 2 - 1 17 8 16 Vdc 0.1 Adc
S1 9 - 10 5 2 4 Vdc 1.8 Adc
S2 7 - 10 7 3 6 Vdc 1.2 Adc
Power
Control IC
Manufacturer
Windings
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
34
FLYBACK TRANSFORMER
SIZE E16 1 OUTPUT : 6v
Primary / Secondary Insulation 4000 V
Primary / Auxiliary Insulation 1500 V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94 V-0 listed materials
Examples of application with Integrated Circuits :
Remarks : This transformer perfectly fulfils the specification of Power Integrations AN-39 Appendix - A.
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74004 1.7 w Pri 1 - 2 108 60 125 (VOR) 0.28 Apeak 2700 µH
Aux 5 - 4 25 22 Vdc 0.1 Adc
S 7 - 6 8 6 Vdc 0.5 Adc
Shield NC - 2 8
MYRRA
P / N Frequency
Control IC
P / N Input voltage
74004 Power Integrations LNK562 185 - 265 Vrms 1.3 W 66 kHz
Power integrations LNK562 85 - 265 Vrms 1.3 W 66 kHz
Power Integrations LNK563 185 - 265 Vrms 1.7 W 83 kHz
Power Integrations LNK563 85 - 265 Vrms 1.7 W 83 kHz
Power Integrations LNK564 185 - 265 Vrms 2.0 W 100 kHz
Power Integrations LNK564 85 - 265 Vrms 2.0 W 100 kHz
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
35
Frequency
Windings
FLYBACK TRANSFORMER
SIZE E16 1 OUTPUT : 10v
Primary / Secondary Insulation 4000 V
Primary / Auxiliary Insulation 1500 V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94 V-0 listed materials
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74005 1.7 w Pri 1 - 2 108 60 125 (VOR) 0.28 Apeak 2700 µH
Aux 5 - 4 25 22 Vdc 0.1 Adc
S 7 - 6 12 10 Vdc 0.2 Adc
Shield NC - 2 8
Power
Control IC
Manufacturer
Examples of application with Integrated Circuits :
Remarks : This transformer perfectly fulfils the specification of Power Integrations AN-39 Appendix - B.
MYRRA
P / N
Control IC
P / N Input voltage
74005 Power Integrations LNK562 185 - 265 Vrms 1.3 W 66 kHz
Power integrations LNK562 85 - 265 Vrms 1.3 W 66 kHz
Power Integrations LNK563 185 - 265 Vrms 1.7 W 83 kHz
Power Integrations LNK563 85 - 265 Vrms 1.7 W 83 kHz
Power Integrations LNK564 185 - 265 Vrms 2.0 W 100 kHz
Power Integrations LNK564 85 - 265 Vrms 2.0 W 100 kHz
Frequency
Windings
FLYBACK TRANSFORMER
SIZE E16 2 OUTPUTS : 5 & 12v
PIN 3 Removed
PCB Drilling Diameter = 1.1mm
+S2
0V
+S1
0V
+E
DRAIN
+AUX
0V
Bottom View (Pin side)
74010
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Examples of application with Integrated Circuits :
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74010 12 w Pri 4 - 6 120 60 125 (VOR) 0.55 Apeak 1660µH
Aux 2 - 1 14 7 14 Vdc 0.1 Adc
S1 9 - 10 7 3.3 7 Vdc 2 Adc
S2 7 - 8 17 8 17 Vdc 1 Adc
74010 Power Integrations 185 - 265Vrms 12w 132kHz
Power Integrations 85 - 265Vrms 10w 132kHz
Power Integrations 185 - 265Vrms 12w 132kHz
Power Integrations 85 - 265Vrms 10w 132kHz
Power Integrations 185 - 265Vrms 12w 132kHz
ST Microelectronics 85 - 265Vrms 8w 70kHz
ST Microelectronics 185 - 265Vrms 10w 70kHz
Motorola 85 - 265Vrms 8w 100kHz
Motorola 185 - 265Vrms 10w 100kHz
Infineon 92 - 265Vrms 7,5w 100kHz
Infineon 185 - 265Vrms 10w 100kHz
Fairchild 85 - 265Vrms 7w 50kHz
Fairchild 185 - 265Vrms 10w 100kHz
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
36
Frequency
Windings
FLYBACK TRANSFORMER
SIZE E16 2 OUTPUTS : 2 x 24v
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
37
PIN 3 Removed
PCB Drilling Diameter = 1.1mm
+S2
0V
+S1
0V
+E
DRAIN
+AUX
0V
Bottom View (Pin side)
74014
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Examples of application with Integrated Circuits :
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
74014 12 w Pri 4 - 6 120 70 140 (VOR) 0.5 Apeak 1800µH
Aux 2 - 1 17 9 18 Vdc 0.2 Adc
S1 9 - 10 27 15 30 Vdc 0.4 Adc
S2 7 - 8 27 15 30 Vdc 0.4 Adc
74014 Power Integrations 185 - 265Vrms 12w
Power Integrations 85 - 265Vrms 8w
Power Integrations 185 - 265Vrms 12w 132kHz
Power Integrations 85 - 265Vrms 8w 132kHz
Typical outputs : +24V 0.5A with S1 S2 in parallel
+48V 0.25A with S1 S2 in series (8-9 connected)
+15V / -15V 0.4A with pins 8-9 connected to 0V
Windings
Frequency
FLYBACK TRANSFORMER
SIZE E16 3 OUTPUTS : 5 / 15 / 24v
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
38
PIN 3 Removed
PCB Drilling Diameter = 1.1mm
+S3
+S2
+S1
0V
+E
DRAIN
+AUX
0V
Bottom View (Pin side)
74015
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Examples of application with Integrated Circuits :
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
74015 Power Integrations 185 - 265Vrms 10w
Power Integrations 85 - 265Vrms 8w
Power Integrations 185 - 265Vrms 12w 132kHz
Power Integrations 85 - 265Vrms 9w 132kHz
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74015 12 w Pri 4 - 6 120 110 (VOR) 0.5 Apeak 1800µH
Aux 2 - 1 14 12 Vdc 0.2 Adc
S1 9 - 10 6 5 Vdc 1.5 Adc
S2 8 - 10 17 15 Vdc 0.6 Adc
S3 7 - 10 27 24 Vdc 0.4 Adc
Frequency
Windings
FLYBACK TRANSFORMER
SIZE EL19 2 OUTPUTS : 5 & 12v
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
39
E
DRAIN
+AUX
0V
+S2
0V
+S1
0V
Bottom View (Pin side)
74020 / 74021
PCB Drilling Diameter = 1.1mm
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Examples of application with Integrated Circuits :
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74020 Power Integrations 85 - 265Vrms 15w 132kHz
Power Integrations 185 - 265Vrms 18w 132kHz
Power Integrations 85 - 265Vrms 12w 132kHz
ST Microelectronics 85 - 265Vrms 10w 100kHz
ST Microelectronics 185 - 265Vrms 12w 100kHz
ST Microelectronics 185 - 265Vrms 16w 100kHz
Motorola 185 - 265Vrms 16w 100kHz
Infineon 185 - 265Vrms 16w 100kHz
74021 ST Microelectronics 85 - 265Vrms 13w 70kHz
Motorola 85 - 265Vrms 13w 100kHz
Infineon 92 - 265Vrms 10w 100kHz
74020 18 w Pri 4 - 6 108 65 130 (VOR) 0.8 Apeak 1250µH
Aux 2 - 1 12 7 14 Vdc 0.1 Adc
S1 9 - 10 6 3.3 7 Vdc 3 Adc
S2 7 - 8 14 8 16.5 Vdc 1.4 Adc
74021 18 w Pri 4 - 6 108 65 130 (VOR) 1.1 Apeak 900µH
Aux 2 - 1 12 7 14 Vdc 0.1 Adc
S1 9 - 10 6 3.3 7 Vdc 3 Adc
S2 7 - 8 14 8 16.5 Vdc 1.4 Adc
Windings
Power
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
40
Frequency
FLYBACK TRANSFORMER
SIZE EL19 5 OUTPUTS : 3.3 / 5 / 12 / 18 / 30v
Bottom View (Pin side)
E 10
DRAIN 9
+Aux 8
0v 7
1+S5
2+S4
3+S3
4+S2
5+S1
60V
PCB Drilling Diameter = 1.1mm
74023
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 60°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Examples of application with Integrated Circuits :
MYRRA
P / N
Control IC
Manufacturer Input voltage
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74023 Power Integrations 185 - 265Vrms 16w 132kHz
Power Integrations 85 - 265Vrms 12w 132kHz
74023 16 w Pri 9 10 120 110 (VOR) 0.85 Apeak 1250µH
Aux 8 7 17 15 Vdc 0.2 Adc
S1 5 6 4 3.3 Vdc 2 Adc
S2 4 6 6 5 Vdc Sum S1+S2
S3 3 6 14 12 Vdc 0.8 Adc
S4 2 6 20 18 Vdc 0.8 Adc
S5 1 6 33 30 Vdc 0.2 Adc
Frequency
Control IC
Manufacturer
Windings
74080 24 w Pri 4 5 86 80 135 (VOR) 1.0 Apeak 1000µH
74087 Aux 2 1 12 11 - 18 Vdc 0.3 Adc
S1 6 7 10 9 15 Vdc 1.5 Adc
S2 9 10 10 9 15 Vdc 1.5 Adc
74081 20 w Pri 4 5 80 75 (VOR) 0.9 Apeak 1100µH
74088 Aux 2 1 17 15 Vdc 0.3 Adc
S1 7 8 4 3.3 Vdc 3 Adc
S2 6 8 6 5 Vdc Sum S1+S2
S3 9 10 14 12 Vdc 1.3 Adc
74082 20 w Pri 4 5 86 60 135 (VOR) 0.85 Apeak 1300µH
74089 Aux 2 1 12 7 - 18 Vdc 0.3 Adc
S1 6 7 5 3 7.5 Vdc 2.0 Adc
S2 9 10 5 3 7.5 Vdc 2.0 Adc
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
FLYBACK TRANSFORMER
SIZE EF20 2 or 3 OUTPUTS : 5/5v or 12/12v or 3.3+5/12v
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
41
Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 8mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Examples of application with Integrated Circuits :
Note for 74080 and 74082 : S1 and S2 can be connected in series or in parallel
PIN 3 Removed
PCB Drilling Diameter = 1.2mm
+S2
+S1
0V
+S3
0V
+E
DRAIN
+AUX
0V
+E
DRAIN
+AUX
0V
+S1
0V
+S2
0V
74080 - 74082
74081 - 74088
74087 - 74089
Power
MYRRA
P / N Input voltage
74080 Power Integrations 185 - 265Vrms 24w 132kHz
74087 Power Integrations 85 - 265Vrms 15w 132kHz
74081 Power Integrations 185 - 265Vrms 20w 132kHz
74088 Power Integrations 85 265Vrms 12w 132kHz
74082 Power Integrations 185 - 265Vrms 20w 132kHz
74089 Power Integrations 85 265Vrms 14w 132kHz
Power Integrations 185 - 265Vrms 17w < 120kHz
Frequency
Windings
74030 30 w Pri 3 5 70 65 130 (VOR) 1.5 Apeak 750µH
Aux 2 1 8 7 14.5 Vdc 1 Adc
S1 7 8 4 3.3 - 7 3 Adc
S2 6 8 9 8 16 Vdc 1.5 Adc
S3 9 10 9 8 16 Vdc 1.5 Adc
74032 35 w Pri 3 5 72 62 - 125 (VOR) 1.1 Apeak 110H
Aux 2 1 10 8 - 16 Vdc 1 Adc
S1 6 10 18 15 - 30 Vdc 1.4 Adc
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
42
FLYBACK TRANSFORMER
SIZE E25 3 or 1 OUTPUTS : 5+12/12v or 24v
PIN 4 Removed
PCB Drilling Diameter = 1.4mm
Bottom View
(Pin side)
+S1
0V
+E
DRAIN
+AUX
0V
+E
DRAIN
+AUX
0V
+S2
+S1
0V
+S3
0V
74030
74032
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
Note for 74030 : S2 and S3 can be connected in series or in parallel
Examples of application with Integrated Circuits :
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
74030 Power Integrations 185 - 265Vrms 30w 132kHz
Power Integrations 85 - 265Vrms 25w 66 or 132kHz
ST Microelectronics 85 - 265Vrms 22w 70kHz
ST Microelectronics 185 - 265Vrms 30w 70kHz
Motorola 85 - 265Vrms 22w 100kHz
Motorola 185 - 265Vrms 30w 100kHz
Infineon 185 - 265Vrms 30w 100kHz
Fairchild 85 - 265Vrms 22w 100kHz
74032 Power Integrations 185 - 265Vrms 25w 132kHz
Frequency
Windings
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
43
FLYBACK TRANSFORMER
SIZE ETD29 4 OUTPUTS : 5+12 / 5+12v
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 8mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
PIN 4 Removed
PCB Drilling Diameter = 1.3mm
Bottom View
(Pin side)
+E
DRAIN
+AUX
0V
+S4
+S3
0V
+S2
+S1
0V
Examples of application with Integrated Circuits :
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74040 60 w Pri 5 7 50 60 125 (VOR) 3.0 Apeak 500µH
Aux 3 2 6 7 14.5 Vdc 0.5 Adc
S1 12 13 3 3.3 - 7 4 Adc
S2 11 13 7 8 16.5 Vdc 2.5 Adc
S3 9 10 3 3.3 - 7 4 Adc
S4 8 - 10 7 8 16.5 Vdc 2.5 Adc
Note : S1 / S3 or S2 / S4 can be connected in series or in parallel
74040 Power Integrations 185 - 265Vrms 60w 66 or 132kHz
Power Integrations 85 - 265Vrms 45w 66 or 132kHz
ST Microelectronics 85 - 265Vrms 35w 100kHz
ST Microelectronics 185 - 265Vrms 45w 100kHz
Motorola 85 - 265Vrms 35w 100kHz
Motorola 185 - 265Vrms 45w 100kHz
Infineon 92 - 265Vrms 35w 100kHz
Infineon 185 - 265Vrms 45w 100kHz
74043 60w Pri 5 1 45 90 (VOR) 3 Apeak 500µH
Aux 8 9 7 15 Vdc 0.5 Adc
S1 14+15 / 12+13 2 3.3 Vdc 7 Adc
S2 11 / 12+13 3 5 Vdc Sum S1+S2
S3 16 10 4 12 Vdc 2 Adc
S4 17 10 7 18 Vdc 2 Adc
S5 18 10 13 30 Vdc 0.5 Adc
Frequency
Windings
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
44
FLYBACK TRANSFORMER
SIZE ERL28 5 OUTPUTS : 3.3 / 5 / 12 / 18 / 30v
Bottom View (Pin side)
PCB Drilling Diameter = 1.3mm
E 1
DRAIN 5
+Aux 8
0v 9
18 +30v
17 +18v
16 +12v
10 +5v(dc)
11 +5v(ac)
14,15 +3v3
12,13 0v
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 6mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Power
Examples of application with Integrated Circuits :
MYRRA
P / N
Control IC
Manufacturer Input voltage
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74043 Power Integrations 185 - 265Vrms 60w 66 or 132kHz
Power Integrations 85 - 265Vrms 45w 66 or 132kHz
Frequency
Windings
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
45
FLYBACK TRANSFORMER
SIZE ETD34 4 OUTPUTS : 5+12 / 5+12v
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 8mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
PIN 4 Removed
PCB Drilling Diameter = 1.5mm
Bottom View
(Pin side)
+E
DRAIN
+AUX
0V
+S4
+S3
0V
+S2
+S1
0V
Examples of application with Integrated Circuits :
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74050 90 w Pri 5 7 36 65 125 (VOR) 2.8 Apeak 500µH
Aux 3 2 4 7 14 Vdc 0.5 Adc
S1 12 13 2 3.3 6.5 5 Adc
S2 11 13 5 8.5 17 Vdc 3 Adc
S3 9 10 2 3.3 6.5 5 Adc
S4 8 - 10 5 8.5 17 Vdc 3 Adc
Note : S1 / S3 or S2 / S4 can be connected in series or in parallel
74050 Power Integrations 185 - 265Vrms 90w 132kHz
Power Integrations 85 - 265Vrms 60w 66 or 132kHz
ST Microelectronics 185 - 265Vrms 80w 70kHz
ST Microelectronics 85 - 265Vrms 60w 70kHz
Motorola 185 - 265Vrms 80w 100kHz
Motorola 85 - 265Vrms 60w 100kHz
Infineon 185 - 265Vrms 80w 100kHz
Infineon 85 - 265Vrms 60w 100kHz
Frequency
Windings
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74060 140 w Pri 5 7 36 65 125 (VOR) 4 Apeak 44H
Aux 3 2 4 7 14 Vdc 0.5 Adc
S1 14 15 2 3.3 6.5 5 Adc
S2 13 15 5 8.5 17 Vdc 5 Adc
S3 11 12 2 3.3 6.5 5 Adc
S4 10 12 5 8.5 17 Vdc 5 Adc
Note : S1 / S3 or S2 / S4 can be connected in series or in parallel
Examples of application with Integrated Circuits :
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
74060 Power Integrations 185 - 265Vrms 140w 132kHz
Power Integrations 85 - 265Vrms 90w 66 or 132kHz
ST Microelectronics 85 - 265Vrms 70w 70kHz
ST Microelectronics 185 - 265Vrms 120w 100kHz
Motorola 85 - 265Vrms 70w 100kHz
Motorola 185 - 265Vrms 120w 100kHz
Infineon 85 - 265Vrms 70w 100kHz
Infineon 185 - 265Vrms 120w 100kHz
Fairchild 85 - 265Vrms 70w 100kHz
Fairchild 185 - 265Vrms 120w 100kHz
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
46
FLYBACK TRANSFORMER
SIZE ETD39 4 OUTPUTS : 5+12 / 5+12v
PIN 4 Removed
PCB Drilling Diameter = 1.5mm
Bottom View
(Pin side)
+E
DRAIN
+AUX
0V
+S4
+S3
0V
+S2
+S1
0V
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 8mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
Frequency
Windings
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
47
FLYBACK TRANSFORMER
SIZE ETD44 4 OUTPUTS : 5+12 / 5+12v
Primary / Secondary Insulation 4000V
Primary / Auxiliary Insulation 1500V
Creepage distance Primary / Secondary 8mm
Ambient temperature < 50°C
Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
Exclusively uses UL94-V0 listed materials
PIN 4 Removed
PCB Drilling Diameter = 1.5mm
Bottom View
(Pin side)
+E
DRAIN
+AUX
0V
+S4
+S3
0V
+S2
+S1
0V
Examples of application with Integrated Circuits :
MYRRA
P / N
Control IC
Manufacturer Input voltage Power
MYRRA
P / N
Output
Power
maximum Pins Turns Voltage Current
maximum
Inductance
(+/-10%)
74070 180 w Pri 5 7 38 65 125 (VOR) 8 Apeak 30H
Aux 3 2 4 7 14 Vdc 0.5 Adc
S1 16 17 2 3.3 6.5 6 Adc
S2 15 17 5 8.5 17 Vdc 5 Adc
S3 13 14 2 3.3 6.5 6 Adc
S4 12 14 5 8.5 17 Vdc 5 Adc
Note : S1 / S3 or S2 / S4 can be connected in series or in parallel
74070 Power Integrations 185 - 265Vrms 180w 66 or 132kHz
Power Integrations 85 - 265Vrms 120w 66kHz
Infineon 185 - 265Vrms 160w 100kHz
Fairchild 185 - 265Vrms 160w 100kHz
Philips 185 - 265Vrms 120w 50kHz
POWER FERRITE TRANSFORMERS
HIGH FREQUENCY FERRITE
48
FLYBACK TRANSFORMER
1TO 35 W FLYBACK TRANSFORMERS STANDARD SIZES
Current range
74330 - 74335 U9.8 1.5 to 47mH 0.18 to 1.1A
74300 - 74306 U10.5 1.5 to 68mH 0.30 to 1.9A
74310 - 74315 U16 1.5 to 33mH 0.75 to 3.3A
74320 - 74325 E25 1.5 to 33mH 0.90 to 4.0A
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
49
COMMON MODE CHOKES RANGE FOR EMI SUPPRESSION
Mainly used to reduce noise conducted through power or signal lines.
The common mode inductance filters symmetrical noise, associated with Y-type safety capaci-
tors connected to ground.
The differential mode inductance filters asymmetrical noise, associated with X-type capacitor
connected between Line and Neutral.
U9.8 U10.5 U16 E25
Inductance range
MYRRA
Part SIZE
MYRRA Inductance Rated Resistance Inductance Resonant
Part Common Mode Current per winding Differential Mode Frequency
min - max (mH) Arms ohm max µH min kHz min
74330 33 - 56 0.18 7 710 210
74331 18 - 31 0.26 3.5 360 280
74332 10 - 17 0.35 2.0 210 400
74333 4.7 - 8 0.5 .95 100 610
74334 2.2 - 3.7 0.8 .4 45 910
74335 1 - 1.7 1.1 .21 20 1300
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
50
COMMON MODE CHOKES FOR EMI SUPPRESSION
Ambient Temperature 50°C
Dielectric Strength 1.5 kV between windings
Electrical characteristics at 25 °C
SIZE : U9.8
ELECTRICAL CHARACTERISTICS :
View from pin side
PCB Drilling diameter 1.0 mm
MECHANICAL CHARACTERISTICS / PINOUT :
MYRRA Inductance Rated Resistance Inductance Resonant
Part Common Mode Current per winding Differential Mode Frequency
min - max (mH) Arms ohm max µH min kHz min
Ambient Temperature 50°C
Dielectric Strength 1.5 kV between windings
Electrical characteristics at 25 °C
SIZE : U10.5
ELECTRICAL CHARACTERISTICS :
View from pin side
PCB Drilling diameter 1.1 mm
MECHANICAL CHARACTERISTICS / PINOUT :
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
51
COMMON MODE CHOKES FOR EMI SUPPRESSION
74306 51 - 85 0.3 4 530 125
74300 33 - 56 0,35 3 400 170
74301 18 - 31 0,45 1,7 240 220
74302 10 - 17 0,6 1 140 320
74303 4.7 - 8 0,9 0,43 65 480
74304 2.2 - 3.7 1,3 0,23 32 740
74305 1 - 1.7 1,9 0,1 14 1000
MYRRA Inductance Rated Resistance Inductance Resonant
Part Common Mode Current per winding Differential Mode Frequency
min - max (mH) Arms ohm max µH min kHz min
74310 22 37 0,75 1 230 170
74311 15 25 0,9 0,75 150 210
74312 10 - 17 1,1 0,44 100 280
74313 4.7 - 8 1,5 0,24 50 440
74314 2.2 - 3.7 2,3 0,095 20 650
74315 1 - 1.7 3,3 0,046 10 1000
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
52
COMMON MODE CHOKES FOR EMI SUPPRESSION
Ambient Temperature 50°C
Dielectric Strength 1.5 kV between windings
Electrical characteristics at 25 °C
SIZE : U16
ELECTRICAL CHARACTERISTICS :
View from pin side
PCB Drilling diameter 1.1 mm
MECHANICAL CHARACTERISTICS / PINOUT :
74320 22 37 0,9 0,54 130 170
74321 15 25 1,1 0,35 90 210
74322 10 - 17 1,3 0,22 50 270
74323 4.7 - 8 1,8 0,105 25 400
74324 2.2 - 3.7 2,7 0,05 11 630
74325 1 - 1.7 4 0,03 7 950
MYRRA Inductance Rated Resistance Inductance Resonant
Part Common Mode Current per winding Differential Mode Frequency
min - max (mH) Arms ohm max µH min kHz min
Ambient Temperature 50°C
Dielectric Strength 1.5 kV between windings
Electrical characteristics at 25 °C
SIZE : E25
ELECTRICAL CHARACTERISTICS :
View from pin side
PCB Drilling diameter 1.2 mm
MECHANICAL CHARACTERISTICS / PINOUT :
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
53
COMMON MODE CHOKES FOR EMI SUPPRESSION
Approx.
Weight
74190 150 w 3.5 mH 0.7 Arms 1.5 22 nF 24 9 9.5 0.5 13 g
74191 300 w 2.8 mH 1.3 Arms 0.73 47 nF 29 10 12 0.7 24 g
74192 500 w 2.0 mH 2.2 Arms 0.35 82 nF 32.5 9 16 0.9 47 g
74196 500 w 1.8 mH 2.2 Arms 0.37 82 nF 38 14 12 0.9 39 g
74193 1000 w 1.3 mH 4.5 Arms 0.15 220 nF 44 14 16.5 1.2 80 g
74194 2200 w 450 µH 10 Arms 0.04 470 nF 50 12 22.5 1.8 140 g
74195 4500 w 250 µH 20 Arms 0.014 1 µF 58 10 28 2.5 250 g
TOROIDAL CHOKES
HIGH FREQUENCY FERRITE
54
DIMMER CHOKES FOR EMI SUPPRESSION
For noise suppression in light dimmers
Saturable chokes : provides a high impedance for Triac switching
interferences, and a low impedance for 50Hz component.
Electrical characteristics at 25 °
ELECTRICAL CHARACTERISTICS :
L = 25 +/-10mm
MECHANICAL CHARACTERISTICS :
Power
Dimensions (mm)
MYRRA
Part
Inductance
+/- 15 %
Rated
Current Resistance Associated
Capacitor OD
max
ID
min
H
max
W
max
Current range
Current range
E13 E19-V E19-H E25
T40
U10.5 T15 T18 T30
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
55
CURRENT TRANSFORMERS RANGE
FOR MAINS AC CURRENT MEASUREMENT - 50 to 400 Hz
FOR SWITCH MODE POWER SUPPLIES - 20 to 150kHz
Ratio
MYRRA
Part SIZE
Ratio
MYRRA
Part SIZE
PIN PRIMARY - up to 25A
74520 Size E19-H Ratio 1 / 1 / 100 Current 10 A/ 20 A
74530 Size E25 Ratio 1 / 1 / 100 Current 12.5 A/ 25 A
74550 Size E13 Ratio 1 / 100 Current 10 A
74560 Size U10.5 Ratio 1 / 100 Current 10 A
74562 Size U10.5 Ratio 1 / 100 Current 10 A
74570 Size T15 Ratio 1 / 1 / 50 Current 10 A/ 20 A
THRU-HOLE PRIMARY - up to 200A
74500 Size T18 Ratio 1 / 50 Current 15 A
74501 Size T18 Ratio 1 / 100 Current 25 A
74502 Size T18 Ratio 1 / 200 Current 25 A
74510 Size T30 Ratio 1 / 100 Current 150 A
74540, 74541, 74542 Size T40 Ratio 1 / 100 Current 200 A
PIN PRIMARY - up to 25A
74521 Size E19-H Ratio 1 / 1 / 750 Current 10 A / 20 A
74523 Size E19-V Ratio 1 / 500 Current 15 A
74531 Size E25 Ratio 1 / 1 / 1000 Current 12.5 A / 25 A
74533 Size E25 Ratio 1 / 1000 Current 8 A
74534 Size E25 Ratio 1 / 350 Current 4 A
74561 Size U10.5 Ratio 1 / 2000 Current 8 A
THRU-HOLE PRIMARY - up to 250A
74503 Size T18 Ratio 1 / 1000 Current 12 A
74504 Size T18 Ratio 1 / 750 Current 10 A
74511 Size T30 Ratio 1 / 1000 Current 60 A
74543, 74544, 74545 Size T40 Ratio 1 / 500 Current 100 A
74546, 74547, 74548 Size T40 Ratio 1 / 1000 Current 250 A
Typical Load/
Accuracy/ Current
74500 50 15 A 6 5 175 VS 15 V 50 / 1% / 15 A
20 200 kHz 20 200 kHz
74501 100 25 A 1.5 20 350 V.µS 25 V 100 / 1% / 25 A
20 100 kHz 20 100 kHz
74502 200 25 A 5 80 700 V.µS 50 V 200 / 1% / 25 A
20 100 kHz 20 100 kHz
74503 1000 12 A 45 2000 2.5 V.ms 0.15V/ 50 Hz/ 12A 10 / 2% / 12 A
50 Hz 0.6V/ 50 Hz/ 8A 40 / 2% / 8 A
74504 750 10 A 35 1100 2.0 V.ms 0.13V/ 50 Hz/ 10A 10 / 2% / 10 A
50 Hz 0.3V/ 50 Hz/ 5A 40 / 2% / 5 A
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
56
TOROIDAL / THRU–HOLE
18 max
12.7
10
max 3 1
21
max
3 1
HOLE
DIA 5
Primary Current
Direction
P
3
S
1
74500 / 74501 / 74502
74503 / 74504
Data applies for one primary turn (single passage of primary wire through toroid hole).
Sensitivity can be increased for lower currents by winding more than one turn.
MYRRA
Part
Sec.
Turns
Max Pri.
Current
A rms
Pulse
Vsec x t max
@ Frequency
Sine
Vsec max
@ Frequency
Rsec.
max
Lsec.
mH
min
Typical Load/
Accuracy/ Current
74510/ 74511
P
7
S
2
Pin 8 removed
for locating
Primary current
direction
6 10
MYRRA
Part
Sec.
Turns
Max Pri.
Current
A rms
Pulse
Vsec x t max
@ Frequency
Sine
Vsec max
@ Frequency
Rsec.
max
Lsec.
mH
min
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
57
TOROIDAL / THRU–HOLE
Data applies for one primary turn (single passage of primary wire through toroid hole).
Sensitivity can be increased for lower currents by winding more than one turn.
Models with 50, 100, 200 turns are designed for switch-mode power conversion
(up to 200 kHz).
Models with 500 and 1000 turns are designed for Mains current measurement (50 to 400 Hz).
74510 100 150 A 0.2540
1 V.ms/ 20 kHz 50 V/ 20 kHz
700 V µs/ 80 V/ 100 kHz 1 - 20 / 1%
100 kHz
74511 1000 60 A 32 4000 10 V.ms/ 50 Hz 0.6 V/ 50 Hz/ 60 A 10 / 1% / 60 A
1 V/ 50 Hz/ 40 A 20 / 1% / 40 A
FOR MAINS AC CURRENT MEASUREMENT - 50 to 400 Hz
FOR SWITCH MODE POWER SUPPLIES - 20 to 150 kHz
74520 1/1/100 20 A parallel 1.5 8 400 V.µs 50 Vrms 10 100 / 1% / 10 A 2500 V
10 A serie
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
58
PIN PRIMARY TYPES
1
P1
4
2
P2
3
8
S
5
74520/ 74521
Pins 6 & 7 removed for locating
SAFETY :
These products are only composed of UL approved materials.
These products have a construction conform to CEI950, CEI335, CEI61558 for Basic insulation
(3 mm creepage distance)
MYRRA
Part
Typical Load/
Accuracy/ Current
Insulation
Voltage
P/ S
Ratio
Max Pri.
Current
A rms
Pulse
Vsec x t
max
Sine
Vsec
rms max
Rsec.
max
Lsec.
mH
min
74521 1/1/750 20 A parallel
10 A serie 57 300 15 V.ms 3 Vrms 75 / 4% / 20 A 2500 V
MYRRA
Part
Typical Load/
Accuracy/ Current
Insulation
Voltage
P/ S
Ratio
Max Pri.
Current
A rms
Pulse
Vsec x t
max
Sine
Vsec
rms max
Rsec.
max
Lsec.
mH
min
FOR MAINS AC CURRENT MEASUREMENT - 50 to 400 Hz
1
P
2
4
S
3
74523
Pins 6 & 7 removed for locating
MYRRA
Part
Typical Load/
Accuracy/ Current
Insulation
Voltage
P/ S
Ratio
Max Pri.
Current
A rms
Pulse
Vsec x t
max
Sine
Vsec
rms max
Rsec.
max
Lsec.
mH
min
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
59
PIN PRIMARY TYPES
SAFETY :
This product is only composed of UL approved materials.
This product has a construction conform to CEI950, CEI335, CEI61558 for Functional insulation
74523 1/ 500 15 A 155 670 30 V.ms 6 Vrms 50 / 2% / 15 A 1500 V
200 / 5% / 10 A
FOR MAINS AC CURRENT MEASUREMENT - 50 to 400 Hz
FOR SWITCH MODE POWER SUPPLIES - 20 to 150 kHz
74531 1/1/1000 25 A parallel 90 4 H 8 V.ms 1.6 Vrms 50 / 2% / 20 A 2500 V
12.5 A serie
74533 1/ 1000 8 A 360 17 H 15 V.ms 3 Vrms 200 / 1% / 8 A 2500 V
500 / 1.5% / 5 A
74534 1/ 350 4 A 380 19 H 15 V.ms 3 Vrms 100 / 1% / 4 A 2500 V
500 / 1% / 2 A
74530 1/1/100 25 A parallel 1 10 600 V.µs 80 Vrms 10 - 100 / 1%/ 25 A 2500 V
12.5 A serie
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
60
PIN PRIMARY TYPES
9
P
7
2
S
4
10
P1
6
9
P2
7
2
S
4
Pins 1 & 8 removed for locating
74530/ 74531
74533/ 74534
SAFETY :
These products are only composed of UL approved materials.
These products have a construction conform to CEI950, CEI335, CEI61558 for Basic insulation
(3 mm creepage distance)
MYRRA
Part
Typical Load/
Accuracy/ Current
Insulation
Voltage
P/ S
Ratio
Max Pri.
Current
A rms
Pulse
Vsec x t
max
Sine
Vsec
rms max
Rsec.
max
Lsec.
mH
min
MYRRA
Part
Typical Load/
Accuracy/ Current
Insulation
Voltage
P/ S
Ratio
Max Pri.
Current
A rms
Pulse
Vsec x t
max
Sine
Vsec
rms max
Rsec.
max
Lsec.
mH
min
Typical Load/
Accuracy/ Current
74540/ 74543/ 74546 Pin type (for PCB) 0.6 x 0.95
Primary Current Direction
P
2
S
1
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
61
TOROIDAL / THRU–HOLE
74540 100 200 A 0.3550 2 V.ms/ 20 kHz 150 V/ 20 kHz 1..20 / 1%
1 V.ms/ 100 kHz 150 V/ 100 kHz
74543 500 100 A 6.5 1250 10 V.ms/ 50 Hz 0.7 V/ 50Hz/ 100 A 3/ 1% / 100 A
1.2 V/ 50Hz/ 60 A 10 / 1% / 60 A
74546 1000 250 A 22 8000 100 V.ms/ 50 Hz 15 V/ 50 Hz/ 250 A 50 / 1% / 250 A
MYRRA
Part
Sec.
Turns
Max Pri.
Current
A rms
Pulse
Vsec x t max
@ Frequency
Sine
Vsec max
@ Frequency
Rsec.
max
Lsec.
mH
min
Data applies for one primary turn (single passage of primary wire through toroid hole).
Sensitivity can be increased for lower currents by winding more than one turn.
Typical Load/
Accuracy/ Current
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
62
TOROIDAL / THRU–HOLE
74541/ 74544/ 74547 FASTON Connectors (4.8 x 0.8)
P
2
S
1
Primary Current Direction
74541 100 200 A 0.3550 2 V.ms/ 20 kHz 150 V/ 20 kHz 1..20 / 1%
1 V.ms/ 100 kHz 150 V/ 100 kHz
74544 500 100 A 6.5 1250 10 V.ms/ 50 Hz 0.7 V/ 50Hz/ 100 A 3/ 1% / 100 A
1.2 V/ 50Hz/ 60 A 10 / 1% / 60 A
74547 1000 250 A 22 8000 100 V.ms/ 50 Hz 15 V/ 50 Hz/ 250 A 50 / 1% / 250 A
MYRRA
Part
Sec.
Turns
Max Pri.
Current
A rms
Pulse
Vsec x t max
@ Frequency
Sine
Vsec max
@ Frequency
Rsec.
max
Lsec.
mH
min
Data applies for one primary turn (single passage of primary wire through toroid hole).
Sensitivity can be increased for lower currents by winding more than one turn.
Typical Load/
Accuracy/ Current
74542/ 74545/ 74548 Wires type
P
2
S
1
Primary current Direction
Wires Length 250 10 mm
1 = Black 0.5 mm2
2 = Red 0.5 mm2
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
63
TOROIDAL / THRU–HOLE
74542 100 200 A 0.3550 2 V.ms/ 20 kHz 150 V/ 20 kHz 1..20 / 1%
1 V.ms/ 100 kHz 150 V/ 100 kHz
74545 500 100 A 6.5 1250 10 V.ms/ 50 Hz 0.7 V/ 50Hz/ 100 A 3/ 1% / 100 A
1.2 V/ 50Hz/ 60 A 10 / 1% / 60 A
74548 1000 250 A 22 8000 100 V.ms/ 50 Hz 15 V/ 50 Hz/ 250 A 50 / 1% / 250 A
MYRRA
Part
Sec.
Turns
Max Pri.
Current
A rms
Pulse
Vsec x t max
@ Frequency
Sine
Vsec max
@ Frequency
Rsec.
max
Lsec.
mH
min
Data applies for one primary turn (single passage of primary wire through toroid hole).
Sensitivity can be increased for lower currents by winding more than one turn.
FOR SWITCH MODE POWER SUPPLIES - 20 to 150 kHz
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
64
PIN PRIMARY TYPES
74550 1/ 100 10 2.3 6 250 V.µs 40 Vrms 10 100 / 1% / 10 A 1500 V
1
P
2
4
S
3
74550
SAFETY :
This product is only composed of UL approved materials.
This product has a construction conform to CEI950, CEI335, CEI61558 for functional insulation
MYRRA
Part
Typical Load/
Accuracy/ Current
Insulation
Voltage
P/ S
Ratio
Max Pri.
Current
A rms
Pulse
Vsec x t
max
Sine
Vsec
rms max
Rsec.
max
Lsec.
mH
min
74561 1/ 2000 8 A 400 4.5 H 5 V.ms 1 Vrms 100 / 2% / 6 A 4000 V
FOR SWITCH MODE POWER SUPPLIES - 20 to 150 kHz
74560 1/ 100 10 1.1 12 300 V.µs 25 Vrms 5 50 / 1% / 10 A 4000 V
74562 1/ 100 25 1.1 12 300 V.µs 25 Vrms 5 50 / 1% / 25 A 4000 V
FOR MAINS AC CURRENT MEASUREMENT - 50 to 400 Hz
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
65
PIN PRIMARY TYPES
1
P
2
4
S
3
74560/ 74561
2
P
5
1
S
6
74562
SAFETY :
These products are only composed of UL approved materials.
These products have a construction conform to CEI950, CEI335, CEI61558 for Reinforced
insulation
74560, 74561 : 8 mm creepage distance
74562 : 6 mm creepage distance
MYRRA
Part
Typical Load/
Accuracy/ Current
Insulation
Voltage
P/ S
Ratio
Max Pri.
Current
A rms
Pulse
Vsec x t
max
Sine
Vsec
rms max
Rsec.
max
Lsec.
mH
min
MYRRA
Part
Typical Load/
Accuracy/ Current
Insulation
Voltage
P/ S
Ratio
Max Pri.
Current
A rms
Pulse
Vsec x t
max
Sine
Vsec
rms max
Rsec.
max
Lsec.
mH
min
FOR SWITCH MODE POWER SUPPLIES - 20 to 150 kHz
CURRENT TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
66
PIN PRIMARY TYPES
74570 1/1/50 20 A parallel 0.32 9 150 V.µs 12 Vrms 5 25 / 1% / 20 A 4000 V
10 A serie
3
P1
6
4
P2
5
1
S
8
74570
Pins 2 & 7 removed for locating
SAFETY :
This product is only composed of UL approved materials.
This product has a construction conform to CEI950, CEI335, CEI61558 for Reinforced insulation
(8 mm creepage distance)
MYRRA
Part
Typical Load/
Accuracy/ Current
Insulation
Voltage
P/ S
Ratio
Max Pri.
Current
A rms
Pulse
Vsec x t
max
Sine
Vsec
rms max
Rsec.
max
Lsec.
mH
min
74600 Size T15 Ratio 1 / 1 / 1 Low stray inductance
74610 Size T25 Ratio 1 / 1 / 1 Low stray inductance
74611 Size T25 Ratio 1 / 1 / 1 Low stray inductance
74620 Size E19-H Ratio 1 / 1 / 1 Low coupling capacitance
74621 Size E19-H Ratio 3 / 1 / 1 Low coupling capacitance
74630 Size E25 Ratio 1 / 1 / 1 Low coupling capacitance
74631 Size E25 Ratio 3 / 1 / 1 Low coupling capacitance
74640 Size E19-V Ratio 1 / 5 For voltage step-up
74641 Size E19-V Ratio 1 / 10 For voltage step-up
74650 Size E13 Ratio 1 / 1 / 1 Small size
74710 Size E16 Ratio 1 / 1 Low coupling capacitance
74660 Size EEM12.7 Ratio 1CT / 1.3CT SMD
74661 Size EEM12.7 Ratio 1CT / 1CT SMD, for DC/DC converter
74670 Size T10 Ratio 1CT / 1.3 SMD, Low stray inductance
E13 E19-V E16 E19-H E25
EEM12.7 T10 T15 T25
PULSE TRANSFORMERS RANGE
HIGH FREQUENCY FERRITE
67
PULSE TRANSFORMERS RANGE
Ratio
MYRRA
Part SIZE
To be used for MOSFET or IGBT Drive, SCR triggering, DC/DC power conversion, Voltage isolation.
Insulation
Voltage
74600 1 / 1 / 1 4 8 0.6 0.35 150 V.µs 0.4 120 pF 1.0 µH 4 kV 4 kV
74610 1 / 1 / 1 0.6 1.2 1.7 0.07 150 V.µs 0.4 35 pF 0.6 µH 4 kV 4 kV
74611 1 / 1 / 1 2.5 - 5 1.2 0.14 300 V.µs 0.8 90 pF 1.2 µH 4 kV 4 kV
PULSE TRANSFORMERS
HIGH FREQUENCY FERRITE
68
PULSE TRANSFORMERS TOROID TYPES
0164700647
11647
74600 Size T15
Pins 2 & 7 removed for locating PCB drill @ Ø 1.1mm Weight 6 g
74610 - 74611 Size T25
Pin 8 removed for locating PCB drill @ Ø 1.3mm Weight 18 g
1
PRI
8
3
S1
4
6
S2
5
4
PRI
2
6
S1
7
9
S2
10
Toroid core gives best coupling, lowest leakage inductance, fast rise time.
Pulse (E.t rating) is given for bipolar (symetrical) pulse. Value is reduced for unipolar pulse.
SAFETY :
These products are only composed of UL-V0 approved materials.
Insulation test voltage : 4000 Vrms
This product has a construction conform to CEI950, CEI335, CEI61558 for Reinforced insulation
(8 mm creepage distance)
MYRRA
Part
Ratio
P/S1/S2
L pri.
+/-30%
Current
/winding
Arms max
Resistance
/winding
max
Pulse
Ex t
Vs max
square
V/ kHz
max
C
P/S
pF max
Lleak
P/S
max
P/ S S1/S2
Insulation
Voltage
74620 1 / 1 / 1 3.2 mH 0.5 1.0 350 V.µs 0.6 5 pF 70 µH 2.5 kV 1.5 kV
74621 3 / 1 / 1 17 mH 0.3 2.0 800 V.µs 1.5 5 pF 400 µH 2.5 kV 1.5 kV
74630 1 / 1 / 1 2 mH 1 0.4 500 Vs 0.8 7 pF 60 µH 2.5 kV 1.5 kV
74631 3 / 1 / 1 10 mH 0.45 0.8 1000 Vs 1.7 7 pF 300 µH 2.5 kV 1.5 kV
PULSE TRANSFORMERS
HIGH FREQUENCY FERRITE
69
E19-H / E25 TYPES
Principally dedicated to SCR triggering
Designed for minimum coupling capacitance
SAFETY :
These products are only composed of UL-V0 approved materials.
74620 74630
74621 74631
74620 - 74621 Size E19-H
Pin 1 removed for locating Weight 12 g
74630 74631 Size E25
Pins 1 & 8 removed for locating Weight 20 g
3
PRI
2
5
S1
6
7
S2
8
4
PRI
2
6
S1
7
9
S2
10
MYRRA
Part
Ratio
P/S1/S2
L pri.
+/-30%
Current
/ winding
Arms max
Resistance
/ winding
max
Pulse
E x t
Vs max
square
V / kHz
max
C
P/S
pF max
Lleak
P/S
max
P/ S S1/S2
PULSE TRANSFORMERS
Insulation
Voltage P/ S
74641 1 / 10 11 mH Pri : 0.4 Pri : 1.8 33 V.ms 8 Vrms / 50 Hz 1500
Sec : 0.04 Sec : 80 100 Vrms / 5 kHz
74640 1 / 5 11 mH Pri : 0.5 Pri : 1.0 16 V.ms 4 Vrms / 50 Hz 1500
Sec : 0.1 Sec : 31 50 Vrms / 5 kHz
PULSE TRANSFORMERS
HIGH FREQUENCY FERRITE
70
LOW FREQUENCY PULSE TRANSFORMERS for voltage step-up
74640-74641 Size E19-V
Pins 3 & 5 removed for locating Weight 14 g
1
PRI
2
6
SEC
4
SAFETY :
These products are only composed of UL-V0 approved materials.
MYRRA
Part
Ratio
P/S
L pri.
+/-30%
Current
Arms max
Resistance
max
Pulse
Vsec . t
max
Sine
Vsec.
max
Insulation
Voltage
74650 1 / 1 / 1 500 µH 0.6 0.28 120 V.µs 20V/ 100kHz 12 pF 2 µH 1.5 kV 1.5 kV
+/-30%
74710 1 / 1 2 mH 0.6 0.6 300 V.µs 50V/ 100kHz 6 pF 44 µH 4 kV
+/-40%
PULSE TRANSFORMERS
HIGH FREQUENCY FERRITE
71
74650 is principally designed for Mosfet drive in SMPS (Forward or Bridge converters)
74710 is principally designed for SCR Triggering
SAFETY :
These products are only composed of UL-V0 approved materials.
The product 74710 has a construction conform to CEI950, CEI335, CEI61558 for Reinforced insulation
(8 mm creepage distance)
74650 74710
74650 Size E13
Pin 8 removed for locating Weight 4 g
74710 Size E16
Weight 8 g
4
PRI
2
6
S1
7
9
S2
10
3
P
1
4
S
6
MYRRA
Part
Ratio
P/S1/S2 L pri.
Current
/ winding
Arms max
Resistance
/ winding
max
Pulse
E x t
Vs max
square
V / kHz
max
C
P/S
pF max
Lleak
P/S
max
P/ S S1/S2
E13 - E16
PULSE TRANSFORMERS
74661 1+1 / 10 µH 3 Apeak 0.2 30 V.µs 0.05 V / kHz 20 pF 0.2 µH 0.5 kV
1+1 +/-10% 0.5 Arms 100 400kHz
Insulation
Voltage
74660 1+1 / 240 µH 0.2 Arms 0.9 50 V.µs 15V 20 pF 0.35 µH 0.5 kV
1.3+1.3 +/-30% 100 500kHz
74670 1+1 /1.3 220 µH 0.4 Arms 0.25 15 V.µs 0.03 V / kHz 12 pF 0.4 µH 4 kV
+/-30% 100 500kHz
PULSE TRANSFORMERS
HIGH FREQUENCY FERRITE
72
74660 74670
74660 – 74661 Size EEM12.7
We ight 3 g
We ight 4 g
74670 – 74714 Size T10
1
P1
2
P2
4
7
SEC
9
1
P1
2
3
P2
4
8
S1
7
6
S2
5
MYRRA
Part
Ratio
P/S Lpri.
Current
/winding
max
Resistance
/winding
max
Pulse
Ex t max
P1 or P2
square
V/ kHz max
P1 or P2
C
P/S
pF max
Lleak
P/S
max
P/ S
74660 can be used in association with MAXIM MAX250 or MAX253
74661 can be used in association with LINEAR TECHNOLOGY LT1424
74660 can be used in association with MAXIM MAX845
SAFETY :
These products are only composed of UL-V0 approved materials.
SMD TYPES
PULSE TRANSFORMERS
Size
74715 3.0 +/-25 % < 0.1 0.06 / 0.1 1 20 MHz 2 / 1+1 200 4000 T10-
(7 9) SMD
74714 1300 +/-40 % < 0.5 0.2 / 0.2 10 200kHz 1 / 1 4 5500 T10-
(2 4) SMD
POWER LINE COMMUNICATION
HIGH FREQUENCY FERRITE
73
POWER LINE COMMUNICATION COUPLING TRANSFORMERS
74710 - 74716 - 74717 74711 74712 74713 74714 - 74715
Designed for coupling signals to power line
Adapted for use with Modem Circuits : ST7537, ST7538, TDA5051 or IC/SS
MYRRA
Part
Insulation
(Vrms)
Inductance
( µH )
Leakage
Inductance
( µH )
Resistance
per winding
P / S (max)
Frequency
range
Turns
ratio
P / S
Max Sec.
current
(mA rms)
(50 - 60 Hz)
74714 - 74715
Reinforced insulation, creepage distance > 8 mm
74714
74715
7
PRI
9
1
S2
2
S1
4
2
PRI
4
9
S
7
Size
74717 400 +/- 40 % 14.4 0.3 / 0.5 20 - 450kHz 1/1.67 40 4000 EF 16
(3 - 1) +/- 10 % H - 5P
74711 2900 +/-40% 44 +/-7% 1 / 1 10 200kHz 1 / 1 4 1500 U9.8-
(1 2) 4P
74716 45000 +/- 40 % 1500 12 / 14 10 - 200kHz 1/1.15 4 4000 EF 16
(3 - 1) +/-10 % H - 5P
74710 2000 +/-40 % 44 +/-7% 0.6 / 0.6 10 450kHz 1 / 1 10 4000 EF16-
(1 3) H-4P
MYRRA
Part
Insulation
(Vrms)
Inductance
( µH )
Leakage
Inductance
( µH )
Resistance
per winding
P / S (max)
Frequency
range
Turns
ratio
P / S
Max Sec.
current
(mA rms)
(50 - 60 Hz)
POWER LINE COMMUNICATION
HIGH FREQUENCY FERRITE
74
POWER LINE COMMUNICATION COUPLING TRANSFORMERS
74710 - 74711 - 74716 74717
Typical application :
Designed for resonance of series coupling capacitor and the
transformer leakage inductance.
MYRRA Part Series Resonance Frequency (kHz) Mains Coupling capacitance (nF)
74710 132.5 33
74711 132.5 33
74716 50 6.8
74717 40 - 90 470
74710 Reinforced insulation, creepage distance > 8 mm
o
o
3
P
1
4
S
6
74711 Functional insulation
2
P
1
3
S
4
74716 - 74717 Reinforced insulation, creepage distance > 8 mm
oo
3
P
1
4
S
6
Modem
Mains
Cc
Insulation
(Vrms)
74713 144 +/-10 % < 5 0.5 / 0.5 10 450kHz 5+1 / 5+1 200 1500 E13-V-
(2 5) 10P
74712 212 +/-10 % < 5 0.8 / 0.04 10kHz 1MHz 5+1 / 1 500 4000 E16-V-
(2 5) (2 5) 10P
Size
74712 - 74713
Typical application :
Designed for resonance of parallel capacitor with the primary
magnetizing inductance.
MYRRA
Part Parallels Resonance Frequency ( kHz ) Mains Coupling capacitor(nF) Parallel capacitor ( nF )
74712 132.5 33 6.8
74713 132.5 33 10
74712
Reinforced insulation, creepage distance > 6 mm
74713
Functional insulation
2
S
4
5
9
P
8
2
P
4
5
7
S
9
10
CcCp
Modem
Mains
POWER LINE COMMUNICATION
HIGH FREQUENCY FERRITE
75
POWER LINE COMMUNICATION COUPLING TRANSFORMERS
MYRRA
Part
Inductance
( µH )
Leakage
Inductance
( µH )
Resistance
per winding
P / S (max)
Frequency
range
Turns
ratio
P / S
Max Sec.
current
(mA rms)
(50 - 60 Hz)
47000 SERIES
ELECTRONIC TRANSFORMERS
76
47000 SERIES - ELECTRONIC TRANSFORMERS
MYRRA encapsulated electronic transformers are
Switched Mode Power Supplies based on Flyback
topology.
They constitute an interesting alternative to the
traditional supply in the most common applications of
power lower than 5W.
ENERGY SAVING due to high efficiency and low standby
power
The applications for the Electronic serie are :
Alternative to the linear transformers in all
AC/DC applications of power up to than 5W
Alternative to DC/DC converters for application
in D.C.current (Telecom supplies, electric
substations etc.)
Industrial, domestic and consumer electronics
applications
Standby devices and others DC or AC auxiliary
supplies
With the same footprint as a EI30 transformer, they will
replace:
- 50 Hz Transformer
- Fuse
- Bridge Rectifier
- Filtering Capacitor
Regulated types will also replace linear regulator and
heatsink
MAIN FEATURES
Wide input voltage range
Increased power. 3 x compared to standard
EI30 transformer
Better energetic efficiency : 70% typical com-
pared to 40% for the conventional supply
Very low Standby Power consumption: meets
requirements of Energy Star or EC Code of
Conduct
Same footprint as EI30 transformer : Upgrade
your application without redesign of PCB
SAFETY STANDARDS
Meets all requirements of:
EN 60950
EN 60335
EN 61558-2-17
Uses UL listed components
Uses UL 94-V0 plastic and resin
EMC STANDARDS
Conducted and radiated emissions conform to
EN 55014-1
EN 55022 class B
Immunity conform to
EN 55014-2
EN 61000-4-x
ONE OUTPUT 2.5 & 5W Regulated
Reference Output voltage
(DC Volts)
Output current
(DC mA)
Output Power
(W)
Efficiency
(%)
Ta
(°C)
47121 3.3 750 2.5 65 +70
47122 5 550 2.75 68 +70
47123 9 270 2.5 72 +70
47124 12 210 2.5 74 +70
47125 15 170 2.5 75 +70
47126 24 110 2.5 77 +70
47151 3.3 1350 4.2 65 +50
47152 5 900 4.5 68 +50
47153 9 550 5 72 +50
47154 12 420 5 75 +50
47155 15 320 5 76 +50
47156 24 220 5 79 +50
DIMENSIONS and PINOUT
4 pins
pins 1 & 5 : AC or DC Input
pin 7: DC output +V
pin 9: DC output 0V
ELECTRICAL SPECIFICATIONS
Input voltage range
85 to 265 Volts AC
85 to 370 Volts DC
Input Frequency 47 to 440 Hz
Output voltage accuracy (full load ) ± 2%
Line output voltage variation ± 0.3%
Load output voltage variation ± 0.5%
No load input power < 200mW
Energy consumption and efficiency :
Meets requirements of Energy Star and
EC Code of Conduct
SAFETY
Prepared for Class II reinforced insulation
Input / Output Isolation test voltage: 4000 Vac
Operating ambient temperature:
- 25°C / + Ta (See table)
Storage temperature: - 40°C / + 85°C
Input protection by integrated fusible resistor
Output short circuit protection: automatic restarts when
fault condition is removed
Thermal shutdown with automatic recovery if internal
temperature exceeds allowable value
47000 SERIES
ELECTRONIC TRANSFORMERS
77
47000 SERIES
ELECTRONIC TRANSFORMERS
78
ONE OUTPUT 3.2 & 5W Non Regulated
ELECTRICAL SPECIFICATIONS
Input voltage range
85 to 265 Volts AC
85 to 370 Volts DC
Input Frequency 47 to 440 Hz
Output voltage accuracy (full load) ± 5%
Line output voltage variation ± 3%
Load output voltage variation 0/ +30%
No load input power < 300mW
SAFETY
Prepared for Class II reinforced insulation
Input / Output Isolation test voltage: 4000 Vac
Operating ambient temperature:
- 25°C / + Ta (See table)
Storage temperature: - 40°C / + 85°C
Input protection by integrated fusible resistor
Output short circuit protection: automatic restarts when
fault condition is removed
Thermal shutdown with automatic recovery if internal
temperature exceeds allowable value
DIMENSIONS and PINOUT
4 pins
pins 1 & 5 : AC or DC Input
pin 7: DC output +V
pin 9: DC output 0V
Reference Output voltage
(DC Volts)
Output current
(DC mA)
Output Power
(W)
Efficiency
(%)
Ta
(°C)
47114 12 200 2.4 74 +70
47133 9 360 3.2 73 +70
47134 12 270 3.2 75 +70
47136 24 130 3.2 80 +70
47163 9 560 5 * 73 +50
47164 12 420 5 * 75 +50
47166 24 210 5 * 80 +50
* Nota: Power up to 5.4W is possible with input voltage 97 Vac
TWO OUTPUTS COMMON & ISOLATED 3 to 5W Regulated
DIMENSIONS and PINOUT
5 pins
pins 1 & 5 : AC or DC Input
pin 6: Common output 0V
pin 7: DC output 1
pin 10: DC output 2
COMMON OUTPUT
Reference
Output 1
Output 2
(DC Volts)
Output 1
Output 2
(DC mA)
Output Power
(W)
Output 1
Output 2
accuracy
Efficiency (%) Ta
(°C)
47243 +10.5
+7
380 max
100 max 4 * ± 3%
+15% 72 +60
47244 + 15
+7
300 max
70 max 4 * ± 3%
± 15% 73 +60
47245 +12
+5.5
130 max
300 max 3.2 ± 5%
± 10% 65 +70
47246 +5
+12
400 (600max)
170 max 4± 3%
± 15% 65 +60
47247 +15
-15
130 max
130 max 4± 8%
± 8% 73 +60
* Nota: Power up to 5W is possible with input voltage 97 Vac and Ta 50°C
DIMENSIONS and PINOUT
6 pins
pins 1 & 5 : AC or DC Input
pin 6: DC output1 0V
pin 7: DC output1 +V
pin 9: DC output2 0V
pin 10: DC output2 +V
ISOLATED OUTPUT
Reference
Output 1
Output 2
(DC Volts)
Output 1
Output 2
(DC mA)
Output Power
(W)
Output 1
Output 2
accuracy
Efficiency (%) Ta
(°C)
47252 5
5
350 (600max)
350 max 3.5 ± 3%
+15% 66 +60
47254 12
12
165 (300max)
165 max 4± 5%
± 15% 72 +60
47255 15
15
135 (200max)
135 max 4± 5%
± 15% 73 +60
47257 5
12
400 (600max)
170 max 4± 3%
± 15% 68 +60
47258 18
8
150 (200max)
150 max 4± 5%
± 15% 72 +60
COMMON OUTPUT
Input / Output Isolation test voltage: 4000 Vac
ISOLATED OUTPUT
Input / Output Isolation test voltage: 4000 Vac
Output1 / Output 2 isolation : 4000Vac
ELECTRICAL SPECIFICATIONS
Input voltage range
85 to 265Volts AC
85 to 370V DC
Input Frequency 47 to 440 Hz
Output voltage accuracy : see table for 10 to 100% rated
load of each output (includes line and load variations)
No load input power < 200mW
Energy consumption and efficiency : Meets requirements
of Energy Star or EC Code of Conduct
The 2 outputs share a common 0v reference.
This enables closer coupling and a better cross-regula-
tion of the outputs
SAFETY
Prepared for Class II reinforced insulation
Operating ambient temperature:
- 25°C / + Ta (See table)
Storage temperature: - 40°C / + 85°C
Input protection by integrated fusible resistor
Output short circuit protection: automatic restarts when
fault condition is removed
Thermal shutdown with automatic recovery if internal
temperature exceeds allowable value
47000 SERIES
ELECTRONIC TRANSFORMERS
79
www.myrra.com
MYRRA S.A.S. : 2 Boulevard de la Haye - Parc Gustave Eiffel - 77600 Bussy St Georges - FRANCE
Tel : +33 (0)1 60 37 55 55 - Fax : +33 (0)1 60 17 12 00
America : contact.usa@myrra.com
Asia : contact.hong-kong@myrra.com
Europe : contact.europe@myrra.com