100 MHz and 200 MHz bandwidth models
2 analog channels, 50 Ω input impedance (standard)
Vertical range: 500 μV/div ~ 10 V/div
Real-time sample rate: up to 1 GSa/s on both channels
Memory depth: up to 28 Mpts on both channels
Waveform capture rate: up to 50,000 wfms/s
Real-time hardware waveform recording, playback, and analysis of up to 65,000
captured frames
Various serial trigger and decode (RS232/UART, I2C, SPI, CAN and LIN)
Complete connectivity: USB DEVICE, USB Host, LAN, and optional GPIB
8-inch WVGA (800×480), 256-level intensity grading display
RIGOL TECHNOLOGIES,INC.
RIGOL 1
DS2000E Series Digital Oscilloscope
Models and Specications
High memory depth (up to 28 Mpts on both channels)
High waveform capture rate (up to 50,000 waveforms per second)
Real-time waveform recording, playback, and analysis functions (up to 65,000 frames)
Multi-level intensity grading display (up to 256-level)
Unique UltraVision technology
Independent Sampling
Running Control Area
Dedicated Decoding
Control Keys
Dedicated Keys and Knob for Waveform
Recording, Playback, and Search
Independent
Channel Control
Dimensions: W×H×D = 361.6 mm×179.6 mm×130.8 mm
Weight: 3.9 kg±0.2 kg (Package Excluded)
Model DS2102E DS2202E
Analog Bandwidth 100 MHz 200 MHz
No. of Analog Channels 2
Max. Real-time Sample Rate 1 GSa/s (for both channels)
Max. Memory Depth 28 Mpts (for both channels)
Max. Waveform Capture Rate 50,000 wfms/s
Hardware Real-time and Ceaseless
Waveform Recording, Playback, and
Analysis Functions
Up to 65,000 frames can be recorded.
Standard Probe All the models include two PVP2350 350 MHz passive high-impedance probes.
RIGOL 2
Wide range (500 μV/div~10 V/div), low noise oor,
clearly capture the low-level signals
UltraVision: high memory depth up to 28 Mpts on both
channels
UltraVision: real-time and ceaseless waveform recording,
playback, and analysis functions
Serial bus trigger and decoding functions (supporting
RS232/UART, I2C, SPI, CAN and LIN)
UltraVision: multi-level intensity grading display
(256-level)
UltraVision: waveform capture rate up to 50,000 wfms/s
Abundant advanced triggering functions (e.g. Runt Trigger,
Setup/Hold Trigger, and Nth Edge Trigger)
RIGOL 3
RIGOL Probes and Accessories Supported by the DS2000E Series
RIGOL Passive Probes RIGOL Active & Current Probes
Model Type Description
RP1001C
Current
Probe
BW: DC to 300 kHz
Maximum Input
DC: ±100 A,
AC P-P: 200 A,
AC RMS: 70 A
Compatibility: All models of RIGOL's
digital oscilloscopes
RP1002C
Current
Probe
BW: DC to 1 MHz
Maximum Input
DC: ±70 A,
AC P-P: 140 A,
AC RMS: 50 A
Compatibility: All models of RIGOLL's
digital oscilloscopes
RP1003C
Current
Probe
BW: DC to 50 MHz
Maximum Input
AC P-P: 50 A (non-continuous),
AC RMS: 30 A
Compatibility: All models of RIGOL's
digital oscilloscopes
Required to order RP1000P power supply.
RP1004C
Current
Probe
BW: DC to 100 MHz
Maximum Input
AC P-P: 50 A (non-continuous),
AC RMS: 30 A
Compatibility: All models of RIGOL's
digital oscilloscopes
Required to order RP1000P power supply.
RP1005C
Current
Probe
BW: DC to 10 MHz
Maximum Input
AC P-P: 300 A (non-continuous), 500 A
(@pulse width ≤ 30 us),
AC RMS: 150 A
Compatibility: All models of RIGOL's
digital oscilloscopes
Required to order RP1000P power supply.
RP1000P
Power
Supply
Power supply for RP1003C, RP1004C and
RP1005C, supporting 4 channels.
RP1025D
High-
voltage
Differential
Probe
BW: 25 MHz
Max. voltage ≤ 1400 Vpp
Compatibility: All models of RIGOL's
digital oscilloscopes
RP1050D
High-
voltage
Differential
Probe
BW: 50 MHz
Max. voltage ≤ 7000 Vpp
Compatibility: All models of RIGOL's
digital oscilloscopes
RP1100D
High-
voltage
Differential
Probe
BW: 100 MHz
Max. voltage ≤ 7000 Vpp
Compatibility: All models of RIGOL's
digital oscilloscopes
Model Type Description
PVP2150
High-
impedance
Probe
1X: DC to 35 MHz
10X: DC to 150 MHz
Compatibility: All models
of RIGOL's digital
oscilloscopes
PVP2350
High-
impedance
Probe
1X: DC to 35 MHz
10X: DC to 350 MHz
Compatibility: All models
of RIGOL's digital
oscilloscopes
RP3500A
High-
impedance
Probe
DC to 500 MHz
Compatibility: All models
of RIGOL's digital
oscilloscopes
RP1300H
High-
voltage
Probe
DC to 300 MHz
CAT I 2000 V (DC+AC),
CAT II 1500 V (DC+AC)
Compatibility: All models
of RIGOL's digital
oscilloscopes
RP1010H
High-
voltage
Probe
DC to 40 MHz
DC: 0 to 10 kV DC,
AC: pulse ≤ 20 kVpp,
AC: sine wave ≤ 7 kVrms
Compatibility: All models
of RIGOL's digital
oscilloscopes
RP1018H
High-
voltage
Probe
DC to 150 MHz
DC+AC Peak: 18 kV CAT II
AC RMS: 12 kV CAT II
Compatibility: All models
of RIGOL's digital
oscilloscopes
RIGOL 4
Specications
All the specications are guaranteed except the parameters marked with "Typical" and the oscilloscope needs to operate for more than 30
minutes under the specied operation temperature.
Sample
Sample Mode Real-time Sampling
Real-time Sample
Rate 1 GSa/s on both channels
Peak Detection 500 ps
Averaging After all the channels have reached N times of sampling at the same time, N can be 2, 4, 8, 16, 32, 64, 128, 256,
512, 1024, 2048, 4096, or 8192.
High Resolution 12-bit resolution when ≥5 μs/div @ 1 GSa/s
Memory Depth Auto, 7 kpts, 70 kpts, 700 kpts, 7 Mpts, and 28 Mpts
Input
Number of Channels 2 analog channels
Input Coupling DC, AC or GND
Input Impedance (1 MΩ±1%)||(16 pF±3 pF) or 50 Ω±1.5%
Probe Attenuation
Coefcient 0.01X-1000X, at 1-2-5 step
Maximum Input
Voltage (1 MΩ) CAT I 300 Vrms, CAT II 100 Vrms, Transient Overvoltage 1000 Vpk
Horizontal
Timebase Scale DS2102E: 5.000 ns/div to 1.000 ks/div
DS2202E: 2.000 ns/div to 1.000 ks/div
Channel to Channel
Skew 1 ns (typical), 2 ns (maximum)
Max. Record Length 28 Mpts on both channels
Timebase Accuracy[1] ≤±25 ppm
Clock Drift ≤±5 ppm/year
Max. Delay Range Negative Delay: ≥1 screen width
Positive Delay: 1 s to 100 ks
Timebase Mode Y-T, X-Y, Roll
Number of X-Ys 1 path
Waveform Capture
Rate[2] 50,000 wfms/s (dots display)
RIGOL 5
Vertical
Bandwidth (-3 dB)
(50 Ω)
DS2102E: DC to 100 MHz
DS2202E: DC to 200 MHz
Single-shot Bandwidth
(50 Ω)
DS2102E: DC to 100 MHz
DS2202E: DC to 200 MHz
Vertical Resolution 8 bit
Vertical Scale[3] When the input impedance is 50 Ω: 500 μV/div to 1 V/div
When the input impedance is 1 MΩ: 500 μV/div to 10 V/div
Offset Range
When the input impedance is 50 Ω:
500 μV/div to 50 mV/div: ±2 V
51 mV/div to 200 mV/div: ±10 V
205 mV/div to 1 V/div: ±12 V
When the input impedance is 1 MΩ:
500 μV /div to 50 mV/div: ±2 V
51 mV/div to 200 mV/div: ±10 V
205 mV/div to 2 V/div: ±50 V
2.05 V/div to 10 V/div: ±100 V
Bandwidth Limit[1] DS2102E: 20 MHz
DS2202E: 20 MHz/100 MHz
Low Frequency
Response (AC
Coupling, -3 dB)
≤5 Hz (on BNC)
Calculated Rise Time[1] DS2102E: 3.5 ns
DS2202E: 1.8 ns
DC Gain Accuracy[3] ±2% of full scale
DC Offset Accuracy ±0.1 div±2 mV±1% of offset value
Channel to Channel
Isolation DC to maximum bandwidth: >40 dB
Trigger
Trigger Level Range Internal ± 5 div from the center of the screen
EXT ±4 V
Trigger Mode Auto, Normal, Single
Holdoff Range 100 ns to 10 s
High Frequency
Rejection[1] 75 kHz
Low Frequency
Rejection[1] 75 kHz
Trigger Sensitivity 1 div (below 10 mV or noise rejection enabled)
0.3 div (above 10 mV and noise rejection disabled)
Edge Trigger
Edge Type Rising, Falling, Rising/Falling
Pulse Trigger
Pulse Condition Positive Pulse Width (greater than, smaller than, within a specic range)
Negative Pulse Width (greater than, smaller than, within a specic range)
Pulse Width 2 ns to 4 s
Runt Trigger
Pulse Condition None, >, <, <>
Pulse Polarity Positive, Negative
Pulse Width Range 2 ns to 4 s
Windows Trigger (Optional)
Windows Type Rising, Falling, Rising/Falling
Trigger Position Enter, Exit, Time
Windows Time 16 ns to 4 s
Nth Edge Trigger (Optional)
Edge Type Rising, Falling
RIGOL 6
Idle Time 16 ns to 4 s
Number of Edges 1 to 65535
Slope Trigger
Slope Condition Positive Slope (greater than, smaller than, within a specic range)
Negative Slope (greater than, smaller than, within a specic range)
Time Setting 10 ns to 1 s
Video Trigger
Polarity Positive, Negative
Synchrony All Lines, Line Num, Odd Field, Even Field
Standard standard: NTSC, PAL/SECAM, 480P, 576P
optional: 720P, 1080P, 1080I
Pattern Trigger
Pattern Setting H, L, X, Rising Edge, Falling Edge
Delay Trigger (Optional)
Edge Type Rising, Falling
Delay Type >, <, <>, ><
Delay Time 2 ns to 4 s
TimeOut Trigger (Optional)
Edge Type Rising, Falling, Rising/Falling
Timeout Time 16 ns to 4 s
Duration Trigger (Optional)
Pattern Setting H, L, X
Trigger Criteria >, <, <>
Duration Time 2 ns to 4 s
Setup/Hold Trigger
Edge Type Rising, Falling
Data Type H, L
Setup Time 2 ns to 1 s
Hold Time 2 ns to 1 s
RS232 Trigger
Polarity Normal, Invert
Trigger Condition Start, Error, Check Error, Data
Baud 2400 bps, 4800 bps, 9600 bps, 19200 bps, 38400 bps, 57600 bps, 115200 bps, 230400 bps, 460800 bps, 921600
bps, 1 Mbps, and User
Data Bits 5 bit, 6 bit, 7 bit, 8 bit
I2C Trigger
Trigger Condition Start, Restart, Stop, Missing ACK, Address, Data, A&D
Address Bits 7 bits, 8 bits, 10 bits
Address Range 0 to 127, 0 to 255, 0 to 1023
Byte Length 1 to 5
SPI Trigger
Trigger Condition Timeout
Timeout Value 100 ns to 1 s
Data Bits 4 bits to 32 bits
Data Setting H, L, X
CAN Trigger (Optional)
Signal Type Rx, Tx, CAN_H, CAN_L, Differential
Trigger Condition SOF, EOF, Frame Type, Frame Error
Baud 10 kbps, 20 kbps, 33.3 kbps, 50 kbps, 62.5 kbps, 83.3 kbps, 100 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps, 1
Mbps, User
Sample Point 5% to 95%
RIGOL 7
Frame Type Data, Remote, Error, Over Load
Error Type Bit Fill, Answer Error, Check Error, Format Error, Random Error
USB Trigger (Optional)
Baud Low Speed, Full Speed
Trigger Condition SOP, EOP, RC, Suspend, Exit Suspend
LIN Trigger (Optional)
Version 1.X, 2.X, Both
Trigger Condition Sync, Identier, Data, ID&Data, Wakeup, Sleep, Error
ID Range 0 to 63
Data Comparison =, ≠, <, >, ≤, ≥
Data Length 1 to 8
Data Level H, L
Baud Rate 19200 bps, 10417 bps, 9600 bps, 4800 bps, 2400 bps, 1200 bps, User
Error Type Sync, Even-Odd, Checksum
Measure
Marker
Manual Mode
Voltage Deviation between Cursors ( V)
Time Deviation between Cursors ( T)
Reciprocal of T (Hz) (1/ T)
Track Mode Voltage and Time Values of the Waveform Point
Auto Mode Allows to display cursors during auto measurement
Auto Measurement
Maximum, Minimum, Peak-Peak Value, Top Value, Bottom Value, Amplitude, Average, Vrms-N, Vrms-1, Overshoot,
Pre-shoot, Area, Period Area, Frequency, Period, Rise Time, Fall Time, Positive Pulse Width, Negative Pulse Width,
Positive Duty Cycle, Negative Duty Cycle, Delay A B , Delay A B , Delay A B , Delay A B ,
Phase A B , Phase A B , Phase A B , Phase A B
Number of
Measurements Displays 5 measurements at the same time
Measurement Range Screen region or cursor region
Measurement Statistics Current, Average, Max, Min, Standard Deviation, Number of Measurements
Frequency Counter Hardware 6-bit frequency counter (channels are selectable)
Math Operation
Waveform
Operation A+B, A-B, A×B, A÷B, FFT, Digital Filter, Editable Advanced Operation, Logic Operation
FFT Window
Function Rectangle, Hanning, Blackman, Hamming
FFT Display Split, Full screen
FFT Vertical
Scale Vrms, dB
Logic Operation AND, OR, NOT, XOR
Math Function Intg, Diff, Lg, Exp, Sqrt, Sine, Cosine, Tangent
Number of
Buses for
Decoding
2
Decoding Type Parallel (standard), RS232/UART (optional), I2C (optional), SPI (optional), CAN (optional),
LIN (optional)
Display
Display Type 8.0-inch (203 mm) TFT LCD
Display Resolution 800 Horizontal ×RGB×480 Vertical Pixel
Display Color 160,000 Color (TFT)
Persistence Time Min, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 20 s, Innite
Display Type Dots, Vectors
Real-time Clock Time and Date (adjustable for users)
RIGOL 8
I/O
Standard Ports USB Host (USB-GPIB supported), USB Device, LAN, Aux Output (TrigOut/PassFail)
General Specications
Probe Compensation Output
Output Voltage[1] About 3 V, peak-peak
Frequency[1] 1 kHz
Power
Power Voltage 100 V to 240 V, 45 Hz to 440 Hz
Power Maximum 50 W
Fuse 2 A, T degree, 250 V
Environment
Temperature Range Operating: 0 to +50
Non-operating: -40 to +70
Cooling Method Fan cooled
Humidity Range
0 to +30: ≤95%RH
+30 to +40: ≤75%RH
+40 to +50: ≤45%RH
Altitude Operating: below 3,000 m
Non-operating: below 15,000 m
Physical Characteristics
Dimensions[4] Width×Height×Depth = 361.6 mm×179.6 mm×130.8 mm
Weight[5] Package Excluded 3.9 kg±0.2 kg
Package Included 4.5 kg±0.5 kg
Calibration Interval
The recommended calibration interval is 18 months.
Note[1]: Typical.
Note[2]: Maximum value. 10 ns, dots display, auto memory depth.
Note[3]: 500 μV/div is a magnication of 1 mV/div. When calculating the DC Gain Accuracy, the full scale should be considered as 8 mV (calculated based on 1 mV/div).
Note[4]: Supporting legs and handle folded, knob height included.
Note[5]: Standard conguration.
Electromagnetic Compatibility and Safety
EMC
complies with EMC Directive 2014/30/EU,
complies with or above the standard specied in IEC61326-1:2013/EN61326-1:2013 Group 1 Class A
CISPR 11/EN 55011
IEC 61000-4-2:2008/EN 61000-4-2 ±4.0 kV (contact discharge), ±8.0 kV (air discharge)
IEC 61000-4-3:2002/EN 61000-4-3 3 V/m (80 MHz to 1 GHz); 3 V/m (1.4 GHz to 2 GHz);
1 V/m (2.0 GHz to 2.7 GHz)
IEC 61000-4-4:2004/EN 61000-4-4 1 kV power
IEC 61000-4-5:2001/EN 61000-4-5 0.5 kV (phase-to-neutral voltage); 1 kV (phase-to-earth voltage);
1 kV (neutral-to-earth voltage)
IEC 61000-4-6:2003/EN 61000-4-6 3 V, 0.15 to 80 MHz
IEC 61000-4-11:2004/EN 61000-4-11
voltage dip: 0% UT during half cycle; 0% UT during 1 cycle;
70% UT during 25 cycles
short interruption: 0% UT during 250 cycles
Safety complies with IEC 61010-1:2010 (Third Edition)/EN 61010-1:2010, UL 61010-1:2012 R4.16 and CAN/CSA-C22.2
No. 61010-1-12+ GI1+ GI2
RIGOL 9
Order Information
Warranty Period
Three years for the mainframe, excluding the probes and accessories.
Description Order No.
Model DS2102E (100 MHz, 2 analog channels) DS2102E
DS2202E (200 MHz, 2 analog channels) DS2202E
Standard
Accessories
Power Cord conforming to the standard of the destination country -
USB Cable CB-USBA-USBB-FF-150
2 Passive Probes (BW: 350 MHz) PVP2350
Quick Guide (hard copy) -
Optional
Accessories
Rack Mount Kit RM-DS2000A
Passive Probe (500 MHz) RP3500A
USB-GPIB Interface Converter USB-GPIB
A Portable Bag BAG-G1
High Memory
Depth Option 28 Mpts/CH memory (offering the ofcial option for free) -
Advanced
Trigger Option
Windows Trigger, Nth Edge Trigger, Delay Trigger, TimeOut Trigger, Duration Trigger, USB
Trigger AT-DS2000A
Decoding
Options
RS232/UART, I2C, SPI Decoding Kit SD-DS2000A
CAN/LIN Protocol Analysis Kit (Trigger + Decoding) CAN-DS2000A
Bundle Option Include all the advanced trigger options and decoding options BND-DS2000A
Note: For all the accessories and options, please contact the local ofce of RIGOL.
RIGOL® is the registered trademark of RIGOL Technologies, Inc. Product information in this
document subject to update without notice. For the latest information about RIGOL's products,
applications and services, please contact local RIGOL ofce or access RIGOL ofcial
website: www.rigol.com
HEADQUARTER
RIGOL TECHNOLOGIES, INC.
No.156,Cai He Village,
Sha He Town,
Chang Ping District, Beijing,
102206 P.R.China
Tel:+86-10-80706688
Fax:+86-10-80720067
Electronic Measurement
Instrument service and support
email:EMD_support@rigol.com
EUROPE
RIGOL TECHNOLOGIES EU GmbH
Lindbergh str. 4
82178 Puchheim
Germany
Tel: 0049- 89/89418950
Email: info-europe@rigol.com
NORTH AMERICA
RIGOL TECHNOLOGIES, USA INC.
8140 SW Nimbus Ave.
Beaverton, OR 97008
Tel: 877-4-RIGOL-1
Email: info@rigol.com
JAPAN
RIGOL TECHNOLOGIES JAPAN, LLC
MJ BLDG.3F,1-7-4 MINATO,CHUOU-
KU,TOKYO,JAPAN 104-0043
Tel: 03-6262-8932
Fax: 03-6262-8933
Email: info-japan@rigol.com
Aug. 2017