2
ECL Pro™
SY100EP56V
Micrel, Inc.
M9999-120505
hbwhelp@micrel.com or (408) 955-1690
PIN DESCRIPTION
Pin Pin Number Function
D0a, /D0a 1, 2, Channel 0 PECL/ECL differential signal inputs. Multiplexing of these two differential inputs is
D0b, /D0b 4, 5 controlled by SEL0, or COM_SEL. The signal inputs include internal 75kΩ pull-down resistors.
Default condition is LOW when left floating. The input signal should be terminated externally.
See “
Termination
” section
D1a, /D1a 6, 7 Channel 1 PECL/ECL differential signal inputs. Multiplexing of these two differential inputs is
D1b, /D1b 9, 10 controlled by SEL1, or COM_SEL. The signal inputs include internal 75kΩ pull-down resistors.
Default condition is a logic LOW when left floating. The input signal should be terminated
externally. See “
Termination
” section
VBB0, VBB1 3, 8 Channel 0 and Channel 1 reference output voltage. This reference is typically used to bias the
unused inverting input for single-ended input applications, or as the termination point for AC–
coupled differential input applications. VBB reference value is approximately VCC –1.4V, and tracks
VCC 1:1. Maximum sink/source capability is 0.50mA. For single ended PECL inputs, connect to
the unused input through a 50Ω resistor. Decouple the VBB pin with a 0.01µF capacitor. For PECL/
LVPECL inputs, the decoupling capacitor is connected to VCC, since PECL signals are referenced
to VCC. Leave floating if not used.
VEE 11 Negative Power Supply: For PECL/LVPECL applications, connect to GND.
/Q1, Q1 12, 13 Channel 1 100KEP PECL/ECL compatible differential output. PECL/ECL termination is with a 50Ω
resistor to VCC–2V. Unused output pairs may be left floating. Unused single-ended outputs must
have a balanced load. For AC-coupled applications, the output stage emitter follower must have a
DC current path to ground. See “
Termination
” section.
SEL1, SEL0 15, 17 100KEP PECL/ECL compatible Channel 1 and Channel 0 MUX select control. See “
MUX Select
Truth Table
.” Each pin includes an internal 75kΩ pull-down resistor. Default condition when left
floating is LOW.
COM_SEL 16 100KEP PECL/ECL compatible Channel 1 and Channel 0 Common MUX select control. This is
the common select control pin for both Channels 0 and 1. Includes an internal 75kΩ pull-down
resistor. Default condition when left floating is LOW. Leave floating when not used.
/Q0, Q0 18, 19 Channel 0 100K EP PECL/ECL compatible differential output. PECL/ECL termination is with a
50Ω resistor to VCC –2V. Unused output pairs may be left floating. Unused single-ended outputs
must have a balanced load. For AC–coupled applications, the output stage emitter follower must
have a DC current path to ground. See “
Termination
” section.
VCC 14, 20 Positive Power Supply: Both VCC pins must be connected to the same power supply externally.
Bypass with 0.1µF//0.01µF low ESR capacitors.
PACKAGE/ORDERING INFORMATION
20-Pin TSSOP (K4-20-1)
Ordering Information(1)
Package Operating Package Lead
Part Number Type Range Marking Finish
SY100EP56VK4I K4-20-1 Industrial XEP56V Sn-Pb
SY100EP56VK4ITR(2) K4-20-1 Industrial XEP56V Sn-Pb
SY100EP56VK4G(3) K4-20-1 Industrial XEP56V with Pb-Free
Pb-Free bar-line indicator NiPdAu
SY100EP56VK4GTR(2, 3) K4-20-1 Industrial XEP56V with Pb-Free
Pb-Free bar-line indicator NiPdAu
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
VBB0
D0b
/D0b
D1a
/D1a
VBB1
D1b
/D1b
18 /Q0
SEL0
COM_SEL
SEL1
VEE
17
16
15
14
13
12
11
19
20
1
2
3
4
5
6
7
8
9
10
D0a
/D0a
/Q1
Q1
VCC
Q0
VCC
1
0
1
0