NLP40 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES * * * * * * * * 40-50 W AC/DC Universal Input Switch Mode Power Supplies 1 4.25 x 2.5 x 1.15 inch package (1U applications) Smallest industry package Overvoltage and short circuit protection 40 W with free air convection EN55022, EN55011 conducted emission level B EN61000-4-2, -3, -4, -5, -6 immunity compliant UL, VDE and CSA safety approvals Available RoHS compliant The NLP40 series is a 40 W universal input ac-dc power supply on a 4.25 x 2.5 inch card with a maximum component height of 1.15 inches for use in 1U applications. This product is the smallest standard 40 W package in the industry making the series ideal for communication applications with space constraints where a standard 5 x 3 inch card solution is not suitable. The NLP40 provides 40 W of output power with free air convection cooling which can be boosted to 50 W with 20 CFM of air. Standard features include overvoltage and short circuit protection. The series, with full international safety approval and the CE mark, meets conducted noise EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data networking, computer and telecom applications such as hubs, routers, POS terminals, LCD projectors, cable modems and PABX's. This list is not exclusive as the generic feature set of the NLP40 series with industry standard output configurations provides a solution for most low power applications including many industrial applications. 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25 C unless otherwise stated OUTPUT SPECIFICATIONS GENERAL SPECIFICATIONS Total regulation (Line and load) Main output Auxiliary outputs Rise time At turn-on Transient response Main output 5.0% max. dev., 25% step at 0.1 A/s 1 ms rec. to 1.0% Temperature coefficient 2.0% 5.0% 1.0 s, max. 0.02%/C Overvoltage protection Main outputs Short circuit protection Cyclic operation Minimum output current Single Multiple 135%, 15% Continuous 0A (See Note 5) INPUT SPECIFICATIONS Input voltage range (See Note 9) 120 Vac 230 Vac 12 ms @ 40 W 20 ms @ 40 W Efficiency 75% typical Isolation voltage Input/output Input/chassis Switching frequency Fixed 65 kHz, 5 kHz Approvals and standards (See Note 8) EN60950, IEC950, UL1950 VDE0805, CSA C22.2 No. 950 Weight MTBF 3000 Vac 1500 Vac 200 g (7.06 oz) MIL-HDBK-217F 150,000 hours min. ENVIRONMENTAL SPECIFICATIONS Universal input Input frequency range 90-264 Vac 120-370 Vdc Thermal performance (See Notes 6, 7, 9) Operating ambient, 0 C to +70 C (see derating curve) Non-operating -40 C to +70 C 50 C to 70 C ambient, Derate to convection cooled 50% load 0 C to 50 C, ambient, 40 W convection cooled 0 C to 50 C ambient, 50 W 20 CFM forced air Peak (0 C to +50 C, 60 s) (See Note 2) Relative humidity Non-condensing Altitude Operating Non-operating Vibration (See Note 4) 5-500 Hz Shock per MIL-STD-810E 47-440 Hz Input surge current 120 Vac, cold start 230 Vac, cold start Safety ground leakage current 120 Vac, 60 Hz 230 Vac, 50 Hz Input current 120 Vac 230 Vac Input fuse UL/IEC127 EMC CHARACTERISTICS Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity Hold-up time 15 A max. 30 A max. 0.2 mA 0.4 mA 1.4 A rms 0.7 A rms 250 Vac H 3.15 A (10) EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 3 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 Perf. Perf. Perf. Perf. Perf. Perf. level B level A criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV File Name: nlp40.pdf Rev (03): 08 Nov 2005 NLP40 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50 W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT CURRENT OUTPUT RIPPLE (1) PEAK (2) FAN TOTAL (3) (1) MODEL NUMBER VOLTAGE MAX +3.3 V (IA) 4A 5A 4.5 A 50 mV 2.0% +12 V (IB) 2A 3A 3A 120 mV 5.0% -12 V (IC) 0.2 A 1A 0.5 A 120 mV 5.0% +5 V (IA) 4A 5A 4.5 A 50 mV 2.0% +12 V (IB) 2A 3A 3A 120 mV 5.0% -12 V (IC) 0.2 A 1A 0.5 A 120 mV 5.0% +5 V (IA) 4A 5A 4.5 A 50 mV 2.0% +15 V (IB) 1.6 A 2A 2A 150 mV 5.0% -15 V (IC) 0.2 A 1A 0.5 A 150 mV 5.0% +12 V (IA) 1.8 A 2.2 A 2.1 A 120 mV 2.0% -12 V (IB) 1.8 A 2.2 A 2.1 A 120 mV 5.0% +5 V (IA) 4A 5A 4.5 A 50 mV 2.0% +12 V (IB) 2A 3A 3A 120 mV 5.0% 3.3 V (IA) 8A 10 A 9A 50 mV 2.0% NLP40-76S3J NLP40-76T366J (5) NLP40-7610J (5) NLP40-7627J (5) NLP40-7629J (5) 5V 8A 10 A 9A 50 mV 2.0% NLP40-7605J 3.3 A 4.5 A 4A 120 mV 2.0% NLP40-7612J 15 V 2.6 A 3.6 A 3.3 A 150 mV 2.0% NLP40-7615J 24 V 1.6 A 2.5 A 2A 240 mV 2.0% NLP40-7624J 48 V 0.8 A 1.1 A 1A 300 mV 2.0% NLP40-7617J Notes (5) NLP40-7608J 12 V Maximum output power is 40 W for natural convection cooling. With 20 CFM fan cooling, the maximum output power is 50 W. 2 Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total reg. limits. 3 Figure is peak-to-peak. Output noise measurements are made across a 50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 F capacitor. 4 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz. 5 For multiple output units (except -7627J, 76T366J) to maintain stated regulation then: 0.25 IA / IB 5, for IB > 0.3 A 0.50 IA / IB 5, for IB < 0.3 A For maximum output current I(C) on triple output models, i.e. for IC = IMax., I A min. 0.5 A and IA IB. For NLP40-7627J only, to maintain stated regulation then: 0.5 IA / IB 2. For NLP40-76T366J only, to maintain stated regulation then: 0.25 IA / IB 4. 6 For optimum reliability, no part of the heatsink should exceed 120 C, and no semiconductor case temperature should exceed 130 C. 7 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. 8 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 9 When the input voltage is <90 Vac the operating range is 0 C to +40 C. 10 For system EMI compliance, a ground choke may be required before connecting the ground wire to the chassis. It is recommended that this ground choke be placed as close as possible to the systems ac inlet to eliminate noise pick-up in the system. 11 The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 12 NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. (11,12) REGULATION DERATING CURVE Output Power (Watts) 1 50W 20 CFM FORCED AIR COOLING 40W 25W NATURAL CONVECTION COOLING 0C 10C 20C 30C 40C 20W 50C 60C 70C File Name: nlp40.pdf Rev (03): 08 Nov 2005 NLP40 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50 W AC/DC Universal Input Switch Mode Power Supplies 3 For the most current data and application support visit www.artesyn.com/powergroup/products.htm 4.25 (107.95) 0.125 (3.175) 4.00 (101.60) J1 F1 N 1 L 2.50 (63.50) J2 2.25 (57.15) P1 T1 C5 ALL DIMENSIONS IN INCHES (mm) Mounting Hole Diameter 0.138 (3.50) Typical MAXIMUM COMPONENT HEIGHT 1.15 (29.21) TOLERANCE: .xxx 0.005" .xx 0.02" Input and output connectors AC (J1) connector type Molex 26-60-4030 type. INPUT PIN CONNECTIONS J1 DC (J2) connector type Molex 26-60-4060 type. Mating connectors AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. DC (J2) mating connector type Molex 09-50-3061 with Triurcon 6838 or equivalent crimp terminals. Note: The input and output connectors are the same as those used on NFS40, NFN40, NAL40 and NAN40. VDE0805/EN60950/IEC950 File 10401-3336-0093 Licence No. 93662 UL1950 File No. E136005 AC Line Pin 2 No Pin Pin 3 AC Neutral Pin 1 Safety Ground P1 J2 International Safety Standard Approvals Pin 1 OUTPUT PIN CONNECTIONS SINGLE DUAL TRIPLE Pin 1 +Vout V (B) V (B) Pin 2 +Vout V (A) V (A) Pin 3 +Vout V (A) V (A) Pin 4 Return Return Return Pin 5 Return Return Return Pin 6 Return Return V (C) CSA C22.2 No. 950 File No. LR41062C Datasheet (c) Artesyn Technologies(R) 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. www.artesyn.com File Name: nlp40.pdf Rev (03): 08 Nov 2005