Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
PD 1 Form A (AQY27)
ASCTB36E 201201-T
TYPES
* Indicate the peak AC and DC values.
Note: The surface mount terminal indicator “A” and the packing style indicator “X” or “Z” are not marked on the device.
RATING
1. Absolute maximum ratings (Ambient temperature: 25°C 77°F)
Flat Power-DIP4-pin type
with high capacity
up to 2A load current PD 1 Form A
(AQY27)
Type
Output rating*
Package
Part No.
Packing quantity
Load
voltage
Load
current
Through hole
terminal Surface-mount terminal
Tube packing style
Tape and reel packing style
Tube Tape and reel
Picked from the
1/2-pin side
Picked from the
3/4-pin side
AC/DC
dual use
60V 2.0A
Power-DIP4-pin
AQY272 AQY272A AQY272AX AQY272AZ 1 tube contains:
50 pcs.
1 batch contains:
1,000 pcs.
1,000 pcs.
100V 1.3A AQY275 AQY275A AQY275AX AQY275AZ
200V 0.65A AQY277 AQY277A AQY277AX AQY277AZ
400V 0.35A AQY274 AQY274A AQY274AX AQY274AZ
Item Symbol AQY272(A) AQY275(A) AQY277(A) AQY274(A) Remarks
Input
LED forward current IF50 mA
LED reverse voltage VR5 V
Peak forward current IFP 1 A f = 100 Hz, Duty factor = 0.1%
Power dissipation Pin 75 mW
Output
Load voltage (peak AC) VL60 V 100 V 200 V 400 V
Continuous load current IL2.0 A 1.3 A 0.65 A 0.35 A Peak AC, DC
Peak load current Ipeak 6.0 A 4.0 A 2.0 A 1.0 A 100ms (1 shot), VL = DC
Power dissipation Pout 700 mW
Total power dissipation PT750 mW
I/O isolation voltage Viso 2,500 V AC
Temperture limits Operating Topr –40°C to +85°C –40°F to +185°FNon-condensing at low temperatures
Storage Tstg –40°C to +100°C –40°F to +212°F
VDE
mm inch
FEATURES
1. Flat-Packaged type
(W) 8.8 × (D) 9.3 × (H) 3.9 mm
(W) .346 × (D) .366 × (H) .154 inch
2. High capacity of continuous load
current 2A (AQY272)
3. High sensitivity and low on-
resistance
Max. 2A load can be controlled with 5mA
input current. The on-resistance is low at
typ. 0.11 (AQY272).
TYPICAL APPLICATIONS
• Measuring and Testing equipment
• IC Testers and Board Testers
• High speed inspection machines
8.8
3.9
9.3
8.8
3.7
9.3
.346
.154
.366
.346
.146
.366
1
2
4
3
RoHS compliant
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
PD 1 Form A (AQY27)
ASCTB36E 201201-T
2. Electrical characteristics (Ambient temperature: 25°C 77°F)
*Turn on/Turn off time
RECOMMENDED OPERATING CONDITIONS
Please obey the following conditions to ensure proper device operation and resetting.
For Dimensions.
For Schematic and Wiring Diagrams.
For Cautions for Use.
These products are not designed for automotive use.
If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation
technical representative.
For more information.
REFERENCE DATA
Item Symbol AQY272(A) AQY275(A) AQY277(A) AQY274(A) Condition
Input
LED operate current Typical IFon
1.0 mA IL = 100 mA
VL = 10 V
Maximum 3.0 mA
LED turn off current Minimum IFoff
0.4 mA IL = 100 mA
VL = 10 V
Typical 0.9 mA
LED dropout voltage Typical VF
1.25 V (1.16 V at IF = 10 mA) IF = 50 mA
Maximum 1.5 V
Output On resistance Typical Ron
0.11 0.23 0.7 2.1 IF = 10 mA, IL = Max.
Within 1 s on time
Maximum 0.18 0.34 1.1 3.2
Off state leakage current Maximum ILeak 10 µAIF = 0 mA, VL = Max.
Transfer
characteristics
Tu rn on time*
Typical
Ton
2.46 ms 2.40 ms 1.12 ms 1.65 ms IF = 10 mA, IL = 100 mA
VL = 10 V
Maximum 5.0 ms
Typical 5.64 ms 5.65 ms 2.57 ms 3.88 ms IF = 5 mA, IL = 100 mA
VL = 10 V
Maximum 10.0 ms
Tu rn off time* Typical Toff
0.22 ms 0.21 ms 0.10 ms 0.08 ms IF = 5 mA or 10 mA, IL = 100 mA
VL = 10 V
Maximum 3.0 ms
I/O capacitance Typical Ciso
0.8 pF f = 1 MHz
VB = 0 V
Maximum 1.5 pF
Initial I/O isolation resistance Minimum Riso 1,000 M500 V DC
Maximum operating speed Maximum 0.5 cps IF = 10 mA, Duty factor = 50%
IL = Max. , VL = Max.
Item Symbol Recommended value Unit
Input LED current IF5 to 10 mA
Ton
Input
Output 10%
90%
Toff
1. Load current vs. ambient temperature
characteristics
Allowable ambient temperature: –40°C to +85°C
–40°F to +185°F
2.-(1) On resistance vs. ambient temperature
characteristics
LED current: 10 mA;
Continuous load current: 2.0 A (DC) (AQY272),
1.3 A (DC) (AQY275)
2.-(2) On resistance vs. ambient temperature
characteristics
LED current: 10 mA;
Continuous load current: 0.65 A (DC) (AQY277),
0.35 A (DC) (AQY274)
3.5
3.0
2.5
2.0
1.5
1.0
0.5
00–40 20 40 60
8085
100–20
Ambient temperature, °C
AQY275
AQY272
AQY274
AQY277
Load current, A
0.5
0.4
0.3
0.2
0.1
00–40 20 40 60 8085
–20
AQY275
AQY272
Ambient temperature, °C
On resistance,
5.0
4.0
3.0
2.0
1.0
00–40 20 40 60
80 85
–20
AQY274
AQY277
Ambient temperature, °C
On resistance,
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
PD 1 Form A (AQY27)
ASCTB36E 201201-T
3. Turn on time vs. ambient temperature
characteristics
LED current: 10 mA; Load voltage: 10 V (DC);
Continuous load current: 100 mA (DC)
4. Turn off time vs. ambient temperature
characteristics
LED current: 10 mA; Load voltage: 10 V (DC);
Continuous load current: 100 mA (DC)
5. LED operate vs. ambient temperature
characteristics
Load voltage: 10 V (DC);
Continuous load current: 100 mA (DC)
10
8
6
4
2
00–40 20 40 60
8085
–20
AQY272
AQY275
AQY274
AQY277
Ambient temperature, °C
Turn on time, ms
1.0
0.8
0.6
0.4
0.2
00–40 20 40 60
80 85
–20
AQY274
AQY277
AQY272
AQY275
Ambient temperature, °C
Turn off time, ms
5
4
3
2
1
00–40 20 40 60
80 85
–20
AQY274
AQY272
AQY275
Ambient temperature, °C
LED operate current, mA
AQY277
6. LED turn off current vs. ambient temperature
characteristics
Load voltage: 10 V (DC);
Continuous load current: 100 mA (DC)
7. LED dropout voltage vs. ambient
temperature characteristics
Sample: all types;
LED current: 5 to 50 mA
8. Current vs. voltage characteristics of output
at MOS portion
Ambient temperature: 25°C 77°F
5
4
3
2
1
00–40 20 40 60
8085
–20
AQY274
AQY275
AQY272
Ambient temperature, °C
LED turn off current, mA
AQY277
1.5
1.4
1.3
1.2
1.1
1.0
00–40 20 40 60 100
80 85
–20
50mA
30mA
20mA
10mA
5mA
Ambient temperature, °C
LED dropout voltage, V
0
–2.0 –1.5 –1.0 –0.5
–1.0
–2.0
–3.0
–4.0
0.5
4.0
1.0
1.0 1.5 2.0
AQY274
AQY275
AQY272
AQY277
Voltage, V
Current, A
3.0
2.0
9.-(1) Off state leakage current vs. load voltage
characteristics
Ambient temperature: 25°C 77°F
9.-(2) Off state leakage current vs. load voltage
characteristics
Ambient temperature: 25°C 77°F
10. Turn on time vs. LED forward current
characteristics
Load voltage: 10 V (DC); Continuous load current:
100 mA (DC); Ambient temperature: 25°C 77°F
10–3
10–6
10–9
10–12
050 100
AQY272
AQY275
Load voltage, V
Off state leakage current, A
10–3
10–6
10–9
10–12
050100
AQY274
AQY277
Load voltage, V
Off state leakage current, A
20
18
16
14
12
10
8
6
4
2
010 20 30 40 500
AQY272
AQY275
AQY274
AQY277
LED forward current, mA
Turn on time, ms
11. Turn off time vs. LED forward current
characteristics
Load voltage: 10 V (DC); Continuous load current:
100 mA (DC); Ambient temperature: 25°C 77°F
12.-(1) Turn on time vs. load voltage
characteristics
LED current: 10 mA; Continuous load current:
100 mA; Ambient temperature: 25°C 77°F
12.-(2) Turn on time vs. load voltage
characteristics
LED current: 10 mA; Continuous load current:
100 mA; Ambient temperature: 25°C 77°F
0.5
0.4
0.3
0.2
0.1
010 20 30 40 500
AQY275
AQY272
AQY277
AQY274
LED forward current, mA
Turn off time, ms
5
4
3
2
1
010 20 30 40 50 60 70 80 90 1000
AQY272
AQY275
Load voltage, V
Turn on time, ms
5
4
3
2
1
050 100 150 200 250 300 350 4000
AQY274
AQY277
Load voltage, V
Turn on time, ms
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
PD 1 Form A (AQY27)
ASCTB36E 201201-T
13.-(1) Turn on time vs. load current
characteristics
LED current: 10 mA; Load voltage: 10 V (DC);
Ambient temperature: 25°C 77°F
13.-(2) Turn on time vs. load current
characteristics
LED current: 10 mA; Load voltage: 10 V (DC);
Ambient temperature: 25°C 77°F
14.-(1) Turn off time vs. load voltage
characteristics
LED current: 10 mA; Continuous load current:
100 mA; Ambient temperature: 25°C 77°F
5
4
3
2
1
00.5 1 1.5 2 2.5 30
AQY272
AQY275
Load current, A
Turn on time, ms
5
4
3
2
1
00 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
AQY277
AQY274
Load current, A
Turn off time, ms
0.5
0.4
0.3
0.2
0.1
00102030405060708090100
AQY272
AQY275
Load voltage, V
Turn off time, ms
14.-(2) Turn off time vs. load voltage
characteristics
LED current: 10 mA; Continuous load current:
100 mA; Ambient temperature: 25°C 77°F
15.-(1) Turn off time vs. load current
characteristics
LED current: 10 mA; Load voltage 10 V (DC);
Ambient temperature: 25°C 77°F
15.-(2) Turn off time vs. load current
characteristics
LED current: 10 mA; Load voltage 10 V (DC);
Ambient temperature: 25°C 77°F
0.5
0.4
0.3
0.2
0.1
0050100 150 200 250 300 350 400
AQY277
AQY274
Load voltage, V
Turn off time, ms
0.5
0.4
0.3
0.2
0.1
00 0.5 1.0 1.5 2.0 2.5 3.0
AQY272
AQY275
Load current, A
Turn off time, ms
0.5
0.4
0.3
0.2
0.1
00 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
AQY277
AQY274
Load current, A
Turn off time, ms
16. Maximum operating frequency vs. load
voltage/current characteristics
Sample: All types; LED current: 10 mA;
Ambient temperature: 25°C 77°F
17. Output capacitance vs. applied voltage
characteristics
Frequency: 1 MHz;
Ambient temperature: 25°C 77°F
10
9
8
7
6
5
4
3
2
1
00255075100 125 150 175 200
Duty factor=50%
Load voltage, V×load current, A
Maximum operating frequency, time/s
2000
1800
1600
1400
1200
1000
800
600
400
200
0020406080100
AQY272
AQY274
Applied voltage, V
Output capacitance, pF
AQY275AQY277
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Panasonic:
AQY272AX AQY272AZ AQY274AX AQY274AZ AQY275 AQY275AX AQY275AZ AQY277 AQY277AX
AQY277AZ AQY274A