1
Power Entry Modules with Line Filter KFA
www.schurter.com/PG06
Connectors
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, optional Voltage Selector (step switch)
Screw-on mounting from front side
Version with ground line choke
without voltage selector
Fuse drawer must be ordered separately (see
accessories).
Snap-in mounting from front side
without voltage selector
Fuse drawer must be ordered separately (see
accessories).
Screw-on mounting from rear side
without voltage selector
Fuse drawer must be ordered separately (see
accessories).
Plug removal necessary for fuse
replacement
C14
70° C
Description
- Panel Mount:
Screw-on version from front or rear side, snap-in version from front
side
- 4 Functions:
Appliance Inlet Protection class I, Fuseholder for fuse-links 5 x 20 mm
1- or 2-pole, with or without voltage selector (step switch), Line filter in
standard and medical version
- V-Lock notch standard
- Quick connect terminals or wires
Unique Selling Proposition
- Reduces noise on the ground wire
- Interrupts ground loops
- High asymmetrical attenuation
- V-Lock cord retaining
Approvals
- VDE Certificate Number: 40004665 (FKE, FKF, FKV, FKW)
- UL File Number: E72928 (FKE, FKF, FKV, FKW)
Characteristics
- Rear side mounting for efficient costsaving assembly
Suitable for assembly in metal plated plastic housings
- All single elements are already wired
- Plug removal necessary for fuse-link replacement
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
- Capacity CX 100 nF
References
Alternative: version without line filter KEA
Alternative: Standard version
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Mating
Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-Stock-
Check, CAD-Drawings, Accessories, Wire Harnessing, Detailed request
for product
Technical Data
Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
Ratings UL/CSA 1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
Leakage Current standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
Dielectric Strength > 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
Allowable Operation Temp. -25 °C to 85 °C
Climatic Category 25/085/21 acc. to IEC 60068-1
Degree of Protection from front side IP 40 acc. to IEC 60529
Protection Class Suitable for appliances with protection
class I acc. to IEC 61140
Terminal Quick connect terminals 6.3 x 0.8 mm
Flexible wire AWG18, 150 mm
Panel Thickness s Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 3 mm
Material: Housing Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet C14 acc. to IEC 60320,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
Fuseholder 1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
Rated Power Acceptance @
Ta 23 °C
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Power Acceptance @ Ta >
23°C
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Voltage Selector optional, step, 3 pos.
Line Filter Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
MTBF > 1'700'000 h acc. to MIL-HB-217 F
2
Power Entry Modules with Line Filter
KFA www.schurter.com/PG06
Connectors
Dimension
Screw-on mounting from front side
R3
M3/ø3.6
33
29
36±0.15
+0.3
0
0
-0.2
27.2
R3.1
44
36
31.2
34
R4.5
R6
230
2.8
56* 46.2**
69* 60.5**
4.8
ø 6.3x90°
ø 3.2
6.3x0.8**
4.8x0.8*
±0.3
* with voltage selector
** without voltage selector
Screw-on mounting from rear side
±0.15
31.2
36.5
2.65
30.3
36
36
30
27.2 2.2
44.3
3.6
+0.20
0 R 4
34.3+0.20
0
60.5
9.5 4.2
46.8
32.8 x 28.5
9.6
R 4
R 5
R 2.5
R 4
M 3
34
Snap-in mounting
29.35
33
R3
± 0.1
R4.1
5 9.5
46
60.5
(31.4)
33 max.
37 max.
(27.4)
37 max.
(28.8)
32.8
+ 0.15
0.00
+ 0.15
0.00
0.8 - 3
3
Power Entry Modules with Line Filter KFA
www.schurter.com/PG06
Connectors
Screw-on mounting from front side with ground line choke
M3 x 0.5
33
36±0.15
+0.3
0
29±0.3 R3 0
-0.2
61
9.5 4.8
56.2
27.2
44
36
31.2
34
R4
R5
Ø3.25
Ø6.3
Technical Data of Filter-Components
Rated Current [A] Filter-Type Inductance L1/
L2 [mH]
Inductance L3
[mH]
Capacitance CX
[nF]
Capacitance CY
[nF]
R [M]
1Standard Version 2 x 10 - 68 2.2 -
2Standard Version 2 x 4 - 68 2.2 -
4Standard Version 2 x 1.5 - 68 2.2 -
6Standard Version 2 x 0.8 - 68 2.2 -
10 Standard Version 2 x 0.3 - 68 2.2 -
1 Standard Version with Ground Line Choke 2 x 10 0.6 100 2.2 -
2 Standard Version with Ground Line Choke 2 x 4 0.6 100 2.2 -
4 Standard Version with Ground Line Choke 2 x 1.5 0.6 100 2.2 -
6 Standard Version with Ground Line Choke 2 x 0.8 0.6 100 2.2 -
10 Standard Version with Ground Line Choke 2 x 0.3 0.6 100 2.2 -
1Medical Version (M5) 2 x 10 - 68 - 1
2Medical Version (M5) 2 x 4 - 68 - 1
4Medical Version (M5) 2 x 1.5 - 68 - 1
6Medical Version (M5) 2 x 0.8 - 68 - 1
10 Medical Version (M5) 2 x 0.3 - 68 - 1
1Medical Version (M80) 2 x 10 - 68 0.47 1
2Medical Version (M80) 2 x 4 - 68 0.47 1
4Medical Version (M80) 2 x 1.5 - 68 0.47 1
6Medical Version (M80) 2 x 0.8 - 68 0.47 1
10 Medical Version (M80) 2 x 0.3 - 68 0.47 1
1 Medical Version (M5) with Ground Line Choke 2 x 10 0.15 100 - 1
2 Medical Version (M5) with Ground Line Choke 2 x 4 0.6 100 - 1
4 Medical Version (M5) with Ground Line Choke 2 x 1.5 0.6 100 - 1
6 Medical Version (M5) with Ground Line Choke 2 x 0.8 0.6 100 - 1
10 Medical Version (M5) with Ground Line Choke 2 x 0.3 0.15 100 - 1
4
Power Entry Modules with Line Filter
KFA www.schurter.com/PG06
Connectors
Diagrams
Standard version
with voltage selector
Cx
L1
L2
Cy
Cy
2)
PE’
L
PE
N
1)
F1
F2
2
1
5
3
X)
X)
x) external connection to be made by the customer
1) Line
2) Load
Standard version
without voltage selector
L
PE
N
Cx
L1
L2
Cy
Cy
L’
PE’
N’
1)
2)
F1
F2
1) Line
2) Load
Medical version (M5)
with voltage selector
Cx
L1
L2
2)
PE’
L
PE
N
1)
F1
F2
2
1
5
3
X)
X)
R
x) external connection to be made by the customer
1) Line
2) Load
Medical version (M5)
without voltage selector
L
PE
N
Cx
L1
L2
L’
PE’
N’
R
1)
2)
F1
F2
1) Line
2) Load
Medical version (M80)
with voltage selector
Cx
L1
L2
2)
L
PE
N
1)
F1
F2
2
1
5
3
X)
X)
RCy
Cy
PE’
x) external connection to be made by the customer
1) Line
2) Load
Medical version (M80)
without voltage selector
L
PE
N
Cx
L1
L2
Cy
Cy
L’
PE’
N’
R
1)
2)
F1
F2
1) Line
2) Load
Standard version with ground line choke
L
PE
N
Cx
L1
L2
Cy
Cy
L’
PE’
N’
1) 2)
F1
F2
L3
1) Line
2) Load
Medical version (M5) with ground line choke
L
PE
N
Cx
L1
L2
L’
PE’
N’
R
1) 2)
F1
F2
L3
1) Line
2) Load
Medical version (M80) with ground line choke
L
PE
N
Cx
L1
L2
Cy
Cy
L’
PE’
N’
R
1) 2)
F1
F2
L3
1) Line
2) Load
Derating Curves
1-pole
Admissible power
acceptance in Watt
020406080 100
I = << In
I = 0.7 In
I = 1.0 In
2.0
1.5
1.0
0.5
0.0
Ambient air temperature Ta °C
2-pole
Admissible power
acceptance in Watt
020406080 100
0.2
0.0
I = << In
I = 0.7 In
I = 1.0 In
1.6
0.6
0.4
0.8
1.2
1.0
1.4
Ambient air temperature Ta °C
5
Power Entry Modules with Line Filter KFA
www.schurter.com/PG06
Connectors
Attenuation Loss - - - - differential mode _____ common mode
Standard version
1 A 2 A 4 A 6 A
10 A
Medical version (M5)
1 A 2 A 4 A 6 A
10 A
Medical version (M80)
1 A 2 A 4 A 6 A
10 A
6
Power Entry Modules with Line Filter
KFA www.schurter.com/PG06
Connectors
Standard with Earth Line Choke
1 A 2 A 4 A 6 A
10 A
Medical (M5) with Earth Line Choke
1 A 2 A 4 A 6 A
10 A
All Variants
Rated Current
[A]
Filter-Type Panel mounting Mounting
side
Fuseholder Terminal Voltage Selector Order Number
1Standard Version Snap-in Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6011
1Standard Version Snap-in Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6001
2Standard Version Snap-in Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6012
2Standard Version Snap-in Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6002
4Standard Version Snap-in Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6013
4Standard Version Snap-in Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6003
6Standard Version Snap-in Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6014
6Standard Version Snap-in Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6004
10 Standard Version Snap-in Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6015
10 Standard Version Snap-in Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6005
1Standard Version Screw Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5011
1Standard Version Screw Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5051
7
Power Entry Modules with Line Filter KFA
www.schurter.com/PG06
Connectors
Rated Current
[A]
Filter-Type Panel mounting Mounting
side
Fuseholder Terminal Voltage Selector Order Number
1Standard Version Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5001
1Standard Version Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5041
1Standard Version Screw Rear Side 1-pole Flexible wire AWG18 -4301.7311
1Standard Version Screw Rear Side 2-pole Flexible wire AWG18 -4301.7301
1Standard Version Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7001
2Standard Version Screw Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5012
2Standard Version Screw Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5052
2Standard Version Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5002
2Standard Version Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5042
2Standard Version Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7002
4Standard Version Screw Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5013
4Standard Version Screw Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5053
4Standard Version Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5003
4Standard Version Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5043
4Standard Version Screw Rear Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7013
4Standard Version Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7003
6Standard Version Screw Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5014
6Standard Version Screw Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5054
6Standard Version Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5004
6Standard Version Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5044
6Standard Version Screw Rear Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7014
6Standard Version Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7004
10 Standard Version Screw Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5015
10 Standard Version Screw Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5055
10 Standard Version Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5005
10 Standard Version Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5045
10 Standard Version Screw Rear Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7015
10 Standard Version Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7005
1 Standard Version with Ground
Line Choke
Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.8050
2 Standard Version with Ground
Line Choke
Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.8051
4 Standard Version with Ground
Line Choke
Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.8052
6 Standard Version with Ground
Line Choke
Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.8053
10 Standard Version with Ground
Line Choke
Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.8054
1Medical Version (M5) Snap-in Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6201
8
Power Entry Modules with Line Filter
KFA www.schurter.com/PG06
Connectors
Rated Current
[A]
Filter-Type Panel mounting Mounting
side
Fuseholder Terminal Voltage Selector Order Number
2Medical Version (M5) Snap-in Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6203
4Medical Version (M5) Snap-in Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6205
6Medical Version (M5) Snap-in Front Side 2-pole Flexible wire AWG18 -4301.6307
6Medical Version (M5) Snap-in Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6207
1Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5241
1Medical Version (M5) Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7201
2Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5203
2Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5243
2Medical Version (M5) Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7203
4Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5205
4Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5245
4Medical Version (M5) Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7205
6Medical Version (M5) Screw Front Side 1-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5217
6Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5247
6Medical Version (M5) Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7207
10 Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5209
10 Medical Version (M5) Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7209
4Medical Version (M80) Snap-in Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.6206
1Medical Version (M80) Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7202
2Medical Version (M80) Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5204
2Medical Version (M80) Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
3 pos. 4301.5244
2Medical Version (M80) Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7204
4Medical Version (M80) Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5206
4Medical Version (M80) Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7206
6Medical Version (M80) Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7208
10 Medical Version (M80) Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.5200
10 Medical Version (M80) Screw Rear Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.7200
1 Medical Version (M5) with
Ground Line Choke
Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.8055
2 Medical Version (M5) with
Ground Line Choke
Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.8056
4 Medical Version (M5) with
Ground Line Choke
Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.8057
6 Medical Version (M5) with
Ground Line Choke
Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.8058
10 Medical Version (M5) with
Ground Line Choke
Screw Front Side 2-pole Quick connect terminals 6.3 x
0.8 mm
-4301.8059
Most Popular.
Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Wire length: 150 mm
9
Power Entry Modules with Line Filter KFA
www.schurter.com/PG06
Connectors
Packaging unit 10 Pcs
Required Accessory
Description
Fusedrawer 2
Fusedrawer für Fuse Links 5x20 mm, with or without Voltage Selector Insert
Fingergrip, 2-pole, Voltage Selector, 110, 150, 220 4301.1014.01
Fingergrip, 2-pole, Voltage Selector, 120, 240 4301.1014.02
Fingergrip, 2-pole, Voltage Selector, 110, 220 4301.1014.03
Fingergrip, 2-pole, Voltage Selector, 115, 220 4301.1014.04
...
Accessories
Wire Harness
Wire harness for SCHURTER products
Assorted Covers
Rear Cover
0859.0072
Cord retaining kits
Cord retaining strain relief
Flat head, A 4700.0001
Countersunk, B 4700.0002
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091
Appliance Outlet further types to KFA
10
Power Entry Modules with Line Filter
KFA www.schurter.com/PG06
Connectors
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06
4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012
Connector further types to KFA ...
Mating Outlets/Connectors shuttered
Power Cord Overview complete
VAC17KS, North America, V-Lock cord retaining, 2.0 m, Connector C17, cord end: 6051.2801
VAC17KS, Europlug, V-Lock cord retaining, 2.0 m, Connector IEC C17, cord end: 6051.2803
VAC13KS, Overview, diverse Connector IEC C13, cord end: VAC13KS
Power Cord further types to KFA
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
25.09.2015
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Schurter:
4301.5015 4301.6012 4301.6014 4301.6013 4301.6015 4301.6011 4301.6004 4301.6002 4301.6005 4301.6001
4301.6003 4301.6203 4301.6205 4301.6201 4301.5005 4301.5001 4301.5002 4301.5003 4301.5003.01
4301.5004 4301.5011 4301.5012 4301.5013 4301.5014 4301.5041 4301.5042 4301.5043 4301.5044 4301.5045
4301.5051 4301.5052 4301.5053 4301.5054 4301.5055 4301.5201 4301.5202 4301.5203 4301.5204 4301.5205
4301.5206 4301.5208 4301.5209 4301.5214 4301.5217 4301.5241 4301.5243 4301.5244 4301.5245 4301.5246
4301.5247 4301.5249 4301.6206 4301.6207 4301.6209 4301.6013.01 4301.6304.01 4301.6307 4301.7011
4301.7012 4301.7013 4301.7014 4301.7015 4301.7201 4301.7202 4301.7203 4301.7204 4301.7205 4301.7206
4301.7207 4301.7208 4301.7209 4301.7301 4301.7005 4301.7003 4301.7001 4301.7004 4301.7002 4301.52
4301.524 4301.72 4301.5200 4301.7200 4301.5240 4301.8051 4301.8052 4301.8053 4301.8054 4301.8055
4301.8056 4301.8057 4301.8058 4301.8059 4301.8050