P Series The Chameleon Adaptable Module for General or Medical Applications UL Recognized CSA Certified VDE Approved PS Unfiltered PE Filtered with "A" Shield PS Filtered P Series The P series power entry module offers full flexibility of design in the most compact package. As the first 10 amp module to provide all five power entry functions in one compact design, the P Series readily adapts to its environment and the needs of international markets. * IEC power line connector * Both North American and European fusing capabilities * Two voltage selections * Optional DPST on/off switch * Filtering options for general purpose and medical applications. The P Series compact design and modular construction will allow you to select all the power entry features you require - without altering the panel cutout. And the P Series, with adapters, will fit any standard panel cutout you currently have designed with either snap-in or flange mounting. The P Series is available with a variety of filtering options: P 04 O Models - This version does not include an RFI filter, but has all other options of the P Series. They are rated for applications up to 10 amps. S Models - General purpose filter for applications where line-to-ground and line-to-line noise must be controlled. These filters allow compliance with FCC limits for linear power supplies. They are available with current ratings of 3, 6, 10 amps. H Models - Designed to help medical equipment meet UL544, UL2601 and EN60601 for patient care equipment and non-patient care equipment, these filters provide susceptibility protection without leakage current associated with line-to-ground capacitors. They are available with current ratings of 3, 6 and 10 amps. B Models - Included with these unfiltered models is an interconnection block that reduces external wiring by connecting the switch with the fuse(s) and IEC receptacle. They are rated for applications up to 10 amps. Z Models - High performance filter versions are designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10 amps. High performance versions are available with horizontal mounting ears, no extenders, single voltage, complete can shield with options for switch, fuses and current ratings only. L Models - High performance Medical filter versions that are designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits while additionally allowing equipment to meet UL544, UL2601 and EN60601 for patient care equipment and non-patient care equipment. They are available with current ratings of 6 and 10 amps. High performance versions are available with horizontal mounting ears, single voltage, complete can shield with options for switch, fuses and current ratings only. Extenders are not available. www.cor.com - Libertyville, IL (847) 680-7400 Series P P Series Part Number System Part numbers are constructed by selecting the alphanumeric character which represents the desired feature. P Series Mounting Style E = Mounting ears (horizontal) S = Snap-in Extender Options 1 0 = None C = FN260 J = J Series L = L series Switch Options Input Voltage Select Fuse Options Filter Type 3 , 0 = No switch S = Double pole single throw (DPST) 0 = Single AC voltage S = Dual AC voltage select (SMPS) X = Dual AC voltage select (series/parallel) D = Dual fuse S = Single fuse 0 = No filter B = Interconnection block H = Medical L = Medical high performance S = General purpose Z = High performance 4 Filter Current 3 Shield Options 0 = No filter or interconnection block 3 = 3 amps 6 = 6 amps X = 10 amps 0 = No shield A = Filter shield B = Complete shield C = Complete can (High performance version) 2, 3 Notes: 1 Extenders cannot be added to units with B or C shields. Extenders allow the P Series to fit other Corcom/competitor panel cutouts. P S J 0 X S S 6 0 No Shield 2 Shields can only be used with filtered models. 3 When using interconnection block, the last 3 digits of the part number are BX0. 4 High performance versions are available with horizontal mounting ears, no extenders, single voltage, complete can shield with options for switch, fuses, filter type (L or Z) and current ratings only. (e.g PE0 _ S _ _ _C) 6A current General purpose filter Single fusing Dual voltage select (series/parallel) No switch J extender Snap-in mount P Series Ordering Information Consult your local Corcom sales representative for pricing. Most Popular Part numbers (Contact factory for availability of component combinations not listed) Filtered PE00XDS60 PE0S0SS6B PE0SSSS60 PE0S0DLXC PE0S0DL6C PE0S0DZXC PE0S0DZ6C PE0S0SLXC PE0S0SL6C PE0S0SZXC PE0S0SZ6C PS000D000 PS000S000 PS000SH30 PS000SS3B PS000SS60 PS000SS6B PS000SSXB PS00XD000 PS00XS000 PS0S0D000 PS0S0DBX0 PS0S0DH3B PS0S0DHX0 PS0S0DS60 PS0S0DS6A PS0S0DS6B PS0S0S000 PS0S0SBX0 PS0S0SH60 PS0S0SH6B PS0S0SHXA PS0S0SS3A PS0S0SS3B PS0S0SS60 PS0S0SS6A PS0S0SSXB PS0SSSH30 PS0SXD000 PS0SXDH30 PS0SXDH3A PS0SXDH60 PS0SXDH6A PS0SXDS30 PS0SXDS3A PS0SXDS60 PS0SXDS6B PS0SXS000 PS0SXSH30 PS0SXSH6A PS0SXSS30 PS0SXSS60 PS0SXSS6A PS0SXSS6B PS0SXSSX0 PSJS0DH30 PSJS0S000 PSJSXS000 Unfiltered PE0SSS000 PSJSXS000 PSJS0S000 PSJ0XD000 PSJ0XS000 PS0SSD000 PS0SSS000 PS0SXD000 PS0SXS000 PS0S0D000 PS0S0S000 PS00SD000 PS00SS000 PS00XD000 PS00XS000 PS000D000 PS000S000 Mounting Styles Corcom offers both flange mounting as well as snap-in mounting of the popular P Series. This allows OEM's to choose the part that best suits their production methods. Extender Option Extenders are available which allow the P series to adapt to Corcom's L or J series cutouts, as well as the panel cutout of Schaffner and Delta parts (C extender). Flange Mount Snap-in Mount www.cor.com - Libertyville, IL (847) 680-7400 eg. The `J' extender will allow the `P' series to fit the Corcom `J' series cutout P 105 P Series applications. The voltage selector installed will allow proper wiring from these applications. No matter what voltage selection scheme is used, wiring is always made to the same four terminals. Fuse / Fuseholder Options Another feature of the P series power entry module is a versatile fusing arrangement. Its fuseholder can hold two 1/4" x 1-1/4" or 5 x 20mm fuses. It can also be converted to accept one fuse with a conversion clip that bridges one of the two fuse chambers. Extenders cannot be added to units with B or C shields. Switch Option The conversion clip is installed on the P Series power entry modules set for single fusing (those with part numbers with an "S" as the sixth digit). Units with a "D" as the sixth digit do not include a conversion clip. Both switched (DPST) and unswitched wiring of the P Series are available. Input Voltage Select The P series of power entry modules provides a dual voltage selector which is integrated with the fuseholder. To simplify the wiring in each individual application, Corcom provides dedicated voltage selectors for different voltage selection schemes. The two most popular schemes are series/parallel for dual primary transformers and the "DPST switch" for switching mode power supplies (jumper types.) P series products with an "S" as the fifth digit are specifically designed for "jumper" type applications associated with switching mode power supplies. Shown is the fuseholder with a fuse held in the proper manner. Note that the back end of the fuse slightly protrudes out of the fuseholder in order to make contact with a terminal inside the power entry module. 1) Dual Primary Transformer Type: Filter Type Six options are available for the filter type: general purpose, medical applications, high performance, high performance medical as well as an unfiltered and unfiltered with an interconnection block. 2) Jumper Type P 06 Note 1: Jumpers are required if a filter or interconnection module is not used. Note 2: Location of optional filter. Jumpers are required if a filter or interconnection module is not used. (Voltage selection not available on L or Z models) Filtered versions include the S Models which are designed for general purpose applications where line-toground and line-to-line noise must be controlled. Z Models are high performance filters designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits. H Models are the medical versions of the S models and are designed to help equipment meet UL544, UL2601 and EN60601 for patient and non-patient care equipment in medical applications. L Models are the medical version of the Z models (high performance) that are designed to additionally allow equipment to meet UL544, UL2601 and EN 60601 for patient and non-patient care equipment. S Model P series products with an "X" as the fifth digit are specifically designed for dual primary transformer www.cor.com - Libertyville, IL (847) 680-7400 Series P allowing the use of the P Series extender. The B shield covers the entire power entry module with metal, protecting the equipment from all radiated noise. The C shield is a complete can for the high performance versions Used with the filter, the shield provides the most secure protection from RFI noise problems. The C shield cannot be used with any extender. H Model Z Model Specifications - Filtered Models Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit Current Frequency-MHz Rating .03 .1 .15 .5 1 3 L Model Unfiltered versions of the P series includes a standard version 0 Models that does not have an RFI filter, but does have all other options of the P Series. It also includes an interconnection block version B Models which provides wiring of the IEC socket to the switch and the switch to the fuseholder. Labor can be eliminated by ordering the product with an interconnection block. This feature, designated by a `BX0' at the end of the part number, prewires the module for easier installation. The wiring is protected with the plastic case to prevent access to the terminals and connections. Wiring can be further simplified by ordering a PA100 connector assembly, as shown in the accessories section. The dimensions of this alternative are the same as the filtered versions. Filter Current The P Series is available without a filter (10A rating) or in 3, 6 and 10 ampere filtered versions. Shield Options A feature available on the P series is an RF shield. The metal shield, available on filtered models, provides shielding from radiated emissions and provides an additional RF ground for the filter to the case. The shield is available in two versions, a shield of the filter components (designated by A as the ninth digit) and a complete shield (designated by B as the ninth digit). S Models 3A 6A 10A H Models 3A 6A 10A 21 12 5 27 17 10 33 23 13 40 32 23 44 36 27 50 44 35 32 30 27 7 17 8 5 21 11 8 27 15 10 30 17 12 29 19 11 26 18 11 23 16 10 15 13 10 1 5 10 30 3 8 5 21 17 27 22 30 24 37 27 43 32 49 52 52 47 42 40 8 5 21 17 27 22 29 23 34 24 35 25 25 21 21 18 16 14 5 10 30 2 2 2 4 4 4 12 12 12 15 15 15 30 22 22 48 42 42 50 55 55 45 45 45 2 2 2 4 4 4 12 12 12 18 16 16 31 26 26 40 35 33 48 40 40 41 35 32 Line-to-line in 50 ohm circuit Current Frequency-MHz Rating .01 .05 .1 .15 0.5 A Shield B Shield The A shield covers the filter portion of the module and increases performance of the filter by protecting the components from magnetic coupling. This shield improves RF ground connection to the case while still www.cor.com - Libertyville, IL (847) 680-7400 Z Models 6A 10A L Models 6A 10A 30 17 8 3 Line-to-line in 50 ohm circuit Current Frequency-MHz Rating .10 .15 .5 1 3 S Models 3A 6A 10A H Models 3A 6A 10A 10 7 Line-to-ground in 50 ohm circuit Current Frequency-MHz Rating .01 .05 .1 .15 0.5 Z Models 6A 10A L Models 6A 10A 5 P 107 1 5 10 30 10 10 15 20 34 20 44 35 75 67 75 75 75 75 70 70 60 60 10 10 15 20 34 20 44 35 75 67 75 75 75 75 70 70 60 60 P Series Specifications - Unfiltered Models Case Dimensions -- Unfiltered Models Hipot rating (one minute): line-to-ground line-to-line Metric shown in italics. 1500 VAC 1450 VDC Operating frequency: D +.008/-.000 +.20/-.00 E 1.98 50.3 1.93 49.0 2.31 58.7 1.122 28.50 2.201 55.91 PS 1.24 31.5 1.93 49.0 2.31 58.7 1.060 26.93 2.201* 55.91 115/230 VAC PSC 1.24 31.5 1.93 49.0 2.81 63.8 1.060 26.92 2.520 64.01 1/4" x 1-1/4" or 5 x 20 mm PSJ 1.24 31.5 1.93 49.0 2.72 69.1 1.060 26.92 2.600+ 66.00 Double-insulated rated for 10,000 operations at full load. 51 Amp inrush capability. PSL 1.24 31.5 1.93 49.0 2.31 58.7 1.120 28.45 2.201* 55.91 10A @ 120 VAC 10A @ 250 VAC Operating voltages: Selectable or fixed Fuseholder: Accepts one or two fuses* 0.187" x 0.032" terminal tabs F +.008/-.000 +.20/-.00 PE 120/250 VAC Rated current, all unfiltered models: Terminals: A B C (max) (max) (max) 50/60 Hz Rated voltage: Switch: Part No. 1.575 40.0 * Panel cutout for thickness of .031 - .079 (0.8 - 2.0). For panel thickness at .083 - .114 (2.1 - 2.9) use 2.213 (56.21). + Panel cutout for thickness of 0.06 - 0.09 (0.76 - 2.29). *Conversion clip provided on fuseholder for single fuse models. Case Styles - Unfiltered Models Metric shown in italics. PSC/PSJ PE Mounting holes PS/PSL .125 Dia. (2) Countersunk holes 3.18 Back View Typical Panel Cutout P 08 * For snap-in applications, the Dsides of the cutout must have a .02 (.508) radius on the installation side. Note: Snap-in models allow front mounting only. PS not recommended for plastic panels. www.cor.com - Libertyville, IL (847) 680-7400 Series Specifications - Filtered Models Case Dimensions - Filtered Models Metric shown in italics. Maximum leakage current, each line-to-ground: @ 120 VAC 60 Hz: H, L models S, Z models @ 250 VAC 50 Hz: H, L models S, Z models 2A 0.25mA 5A .50mA Part No. A B C (max) (max) (max) +.008/-.000 +.20/-.00 D +.008/-.000 +.20/-.00 E F PE 1.98 50.3 2.13 54.1 2.31 58.7 1.120 28.45 2.201 55.91 1.575 40.0 PE 1.98 50.3 4.42 112.3 2.39 60.7 1.150 29.21 2.201 55.91 1.575 40.0 PS 1.24 31.5 2.13 54.1 2.31 58.7 1.060 26.93 2.201* 55.91 1/4" x 1-1/4" or 5 x 20 mm PSC 1.24 31.5 2.13 54.1 2.51 63.8 1.060 26.92 2.520 64.01 50/60 Hz 120/250 VAC PSJ 1.24 31.5 2.13 54.1 2.72 69.1 1.060 26.92 2.600+ 66.00 Double-insulated rated for 10,000 operations at full load. 51 Amp inrush capability. PSL 1.24 31.5 2.13 54.1 2.31 58.7 1.120 28.45 2.201* 55.91 Hipot rating (one minute): line-to-ground line-to-line 1500 VAC 1450 VDC Operating voltages: Selectable or fixed 115/230 VAC Fuseholder: Accepts one or two fuses* Operating frequency: Rated voltage: Switch: P Terminals: 0.187" x 0.032" terminal tabs High Performance * Panel cutout for thickness of .031 - .079 (0.8 - 2.0). For panel thickness at .083 - .114 (2.1 - 2.9) use 2.213 (56.21). + Panel cutout for thickness of 0.06 - 0.09 (0.76 - 2.29). *Conversion clip provided on fuseholder for single fuse models. Case Styles - Filtered Models For shielded models use D = 1.120 + .008 . - .000 Shields can be used only with filtered models. Shields add approximately 0.06" to depth. B and C shields may not be used with extenders. Metric shown in italics. PE PS Back View Typical Panel Cutout PE (High Performance) P 109 * For snap-in applications, the D sides of the cutout must have a .02 (.508) radius on the installation side. .125 Mounting holes Dia. (2) Countersunk holes 3.18 www.cor.com - Libertyville, IL (847) 680-7400 Note: Snap-in models allow front mounting only. PS not recommended for plastic panels.