SPECIFICATION CONTROL DRAWING
Tyco Electronics Corporation
300 Constitution Drive,
Menlo Park, CA. 94025, U.S.A.
Raychem
TITLE:
SOLDERSLEEVE DEVICE
SHIELD TERMINATION WITH BRAID
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets]
DOCUMENT NO.:
SO63-XX-01
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
ANGLES: N/A
ROUGHNESS IN
MICRON
Tyco Electronics reserves the right to amend
this drawing at any time. Users should
evaluate the suitability of the product for their
application.
DOC. ISSUE:
5
DATE:
5-Aug-03
DRAWN BY:
M. FORONDA
CAGE CODE:
06090
REPLACES:
D982100
DCR NUMBER:
D030398
PROD. REV.:
SEE TABLE
SCALE:
None
SIZE:
A
SHEET:
1 of 1
If this document is printed it becomes uncontrolled. Check for the latest revision.
Product Revision Component Dimensions Shall Accommodate with Cable Dimensions
Product
Name
Ident.
Code L±1.75
(L±0.070)
øB
min
øC
min
øD
max
øE
max
øF
min
SO63-1-01 E SO631R
16.50
(0.650)
1.90
(0.075)
2.65
(0.105)
1.90
(0.075)
2.65
(0.105)
0.90
(0.035)
SO63-2-01 E SO632R
16.50
(0.650)
2.65
(0.105)
3.68
(0.145)
2.65
(0.105)
3.68
(0.145)
1.40
(0.055)
SO63-3-01 E SO633R
16.50
(0.650)
4.30
(0.170)
5.08
(0.200)
4.30
(0.170)
5.08
(0.200)
2.15
(0.085)
SO63-4-01 E SO634R
19.10
(0.750)
5.95
(0.235)
6.45
(0.255)
5.95
(0.235)
6.45
(0.255)
3.30
(0.130)
SO63-5-01 E SO635R
19.10
(0.750)
7.00
(0.275)
7.60
(0.300)
7.00
(0.275)
7.60
(0.300)
4.30
(0.170)
MATERIALS
1. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked modified polyvinylidene fluoride.
2. SOLDER PREFORM WITH FLUX AND THERMAL INDICATOR:
SOLDER: TYPE Sn63 per ANSI/J-STD-006.
FLUX: TYPE ROL1 per ANSI/J-STD-004.
THERMAL INDICATOR: Fusible ring, melt point: 221°C.
3. MELTABLE RINGS: Stabilized thermoplastic. Color: blue.
4. PRE-INSTALLED BRAID: Nickel-plated copper strands. CMA 640.
APPLICATION
1. These parts are designed to provide an environment protected shield termination on cables, rated for 125°C minimum, meeting
the dimensional criteria listed and having tin or silver-plated shields and insulation compatible with the insert material.
For compatible insulations, see MIL-S-83519/2 or consult Tyco Electronics/Raychem.
2. When installed per Raychem process standard RCPS-100-70, assemblies will meet those requirements of Raychem
Specification RT-1404 and MIL-S-83519/2 which do not require electrical testing while parts are immersed in water.
3. Temperature range: -55°C to +150°C.
4. Parts shall be marked with identification code per table.
For best results, prepare the cable as shown: