www.carlingtech.com 61
B-Series Handle UL Recognized – Ordering Scheme
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635835.000
640840.000
645845.000
650850.000
11
Agency
Approval
9
Actuator
Color
1 1 AGENCY APPROVAL
CUL Recognized & CSA Accepted
DVDE Certified, UL Recognized & CSA Accepted
ETUV Certified, UL Recognized & CSA Accepted
IUL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted
10 MOUNTING/BARRIERS
MOUNTING STYLE BARRIERS
Threaded Insert, 2 per pole
16-32 x 0.195 inches no
A6-32 X 0.195 inches
(multi-pole units only)
yes
2ISO M3 x 5mm no
BISO M3 x 5mm yes
Rectangular Adapter Plate with mounting centers of 2.062”
[52.37mm] and Threaded insert, 2 per pole
314 6-32 x 0.225 inches no
C14 6-32 X 0.225 inches
(multi-pole units only)
yes
414 ISO M3 x 6.5mm no
D14 ISO M3 x 6.5mm yes
Front panel Snap-In, 0.75” [19.05mm] wide bezel
5without Handleguard no
6without Handleguard
(multi-pole units only)
yes
Front panel Snap-In, 0.96” [24.48mm] wide bezel
7without Handleguard, 1-pole units 0.96” wide; no
multipole units have .105“ bezel overhang on all sides
8without Handleguard, 1-pole units 0.96” wide; yes
(multi-pole units only)
.105“ bezel overhang on all sides
8 TERMINAL9
110 Push-On 0.250 Tab (Q.C.)
2Screw 8-32 w/upturned lugs
311 Screw 8-32 (Bus Type)
4Screw 10-32 w/upturned lugs
511 Screw 10-32 (Bus Type)
6 Screw 8-32 w/upturned lugs
and 30° bend
7Screw 8-32 (Bus Type) and
30° bend
8 Screw 10-32 w/upturned lugs
and 30° bend
9Screw 10-32 (Bus Type) and
30° bend
BScrew M5 w/upturned lugs
CScrew M4 w/upturned lugs
E11 Screw M4 (Bus Type)
FScrew M5 w/upturned lugs
and 30° bend
GScrew M5 (Bus Type)
and 30° bend
HScrew M5 (Bus Type)
L12 0.250 Q.C./ Solder Lug
M11 M6 Threaded Studs
P13 Printed Circuit Board
Terminals
Q16 Push-In Stud
RScrew M4 w/upturned lugs
and 30° bend
S15 Push-On 0.110 Tab (Q.C.)
TScrew M4 (Bus Type)
and 30° bend
5
Aux/Alarm
Switch
5 AUXILIARY/ALARM SWITCH5
0w/o Aux Switch
1 S.P.D.T., 0.093 Q.C. Term.
2 S.P.D.T., 0.110 Q.C. Term.
3S.P.D.T., 0.139 Solder Lug
4S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
5 S.P.S.T., 0.093 Q.C.
Term.(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
7 S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
3 POLES
1One
2Two 3Three
4Four 5Five
6Six
6 FREQUENCY & DELAY
032DC 50/60Hz, Switch Only
106DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
20650/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
42750/60Hz Short, Hi-Inrush
44750/60Hz Medium, Hi-Inrush
46750/60Hz Long, Hi-Inrush
527DC, Short,Hi-Inrush
547DC, Medium, Hi-Inrush
567DC, Long, Hi-Inrush
4 CIRCUIT
A2Switch Only (No Coil)
BSeries Trip (Current)
CSeries Trip (Voltage)
D3Shunt Trip (Current)
E3Shunt Trip (Voltage)
F3Relay Trip (Current)
G3Relay Trip (Voltage)
H3,4 Dual Coil with Shunt Trip
Voltage Coil
J3,4 Dual Coil with Shunt Trip
Voltage Coil (side terminal)
K3,4 Dual Coil with Relay Trip
Voltage Coil
2 ACTUATOR1
AHandle, one per pole
BHandle, one per multipole unit
SMid-Trip Handle, one per pole
TMid-Trip Handle, one per pole & Alarm Switch
1 SERIES
B
7
Current Rating
4
Circuit
3
Poles
2
Actuator 10
Mounting/
Barriers
B
8
Terminal
6
Frequency
& Delay
1
Series
A3B010 450 1B 1 C
Notes:
1 Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
B: Handle location as viewed from front of breaker:
2 pole - left pole 3 pole - center pole
4 pole - two handles at center poles 5 pole - three handles at center poles
6 pole - four handles at center poles
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with cir-
cuit codes B, C, D, E, F, G, H and K.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker. Available with circuit codes B & C.
2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE
Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30
amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
3 Available with Terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
4 Consult factory for available Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils
require 30VA minimum power to trip and are rated for intermittent duty only.
5 Auxiliary Switch breakers with Series Trip and Switch Only circuits. On multi-pole break-
ers, one aux. switch is supplied, mounted in the extreme right pole.
6 Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10 and 20.
7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized and
CSA Accepted to 50 amps.
8 VDE Certification available with single pole breakers with DC Delay only. UL Recognition
and CSA Accepted available in one and two pole breakers.
9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G, H, M and Q.
10 VDE Certification up to 25 amps and UL Recognition and CSA Acceptance up to 30
amps, but not recommended over 20 amps.
11 Terminal Codes 3, 5 E and H (Bus Type) with VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only VDE Certified when the washers are used.
12 VDE Cert. available up to 12 amps. UL Rec. & CSA Acceptance available up to 30 amps.
13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30
amps with VDE Certification and 50 amps with UL Recognition and CSA Acceptance, with
Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit
Board) are available up to 40 amps with UL Recognition and CSA Acceptance with Circuit
Codes A, B and C.
14 Available with Actuator Codes A, S and T.
15 Available with voltage coils only.
16 Terminal Code Q not available with VDE approvals.
9 ACTUATOR COLOR & LEGEND
I-O ON-OFF Dual Legend Color
White AB1Black
Black CD2White
Red FG3White
Green HJ4White
Blue KL5White
Yellow MN6 Black
Gray PQ7Black
Orange RS8Black
A06 6 DC
A12 12 DC
A18 18 DC
A24 24 DC
A32 32 DC
A48 48 DC
A65 65 DC
J06 6 AC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65 65 AC
K20 120 AC
L40 240 AC
7 CURRENT RATING (AMPERES)
OR
VOLTAGE COIL (NOMINAL RATED VOLTAGE)6
––– – –