Altera Corporation 1
Using the ClockLock &
ClockBoost PLL Features
in APEX Devices
April 2001, ver. 2.1 Application Note 115
A-AN-115-02.1
Introduction
APEX
TM
20K devices have the ClockLock
TM
and ClockBoost
TM
features,
which use phase-locked loops (PLLs) to increase performance and
provide clock-frequency synthesis. The ClockLock feature minimizes
clock delay and clock skew within the device, reducing clock-to-output
and setup times while maintaining zero hold times. The ClockBoost
feature allows designers to run the internal logic of the device at a faster
or slower rate than the input clock frequency. This technique simplifies
board design because the clock tree on the board does not have to
distribute a high-speed signal. Through the use of time-domain
multiplexing, the ClockBoost feature allows the designer to improve
device area efficiency by sharing resources within the device.
APEX 20KE devices include PLLs with an enhanced ClockLock feature
set, such as advanced ClockBoost capability for
m
/(
n
×
k
) multiplication,
LVDS support, external clock outputs and feedback ability, and
ClockShift
TM
circuitry for more complex clock-frequency synthesis
applications. These enhanced features permit system-level clock
management and skew control in APEX 20KE devices.
The ClockLock and ClockBoost features provide significant
improvements in system performance, bandwidth, and system-on-a-
programmable-chip (SOPC) integration. This application note explains
the APEX 20K and APEX 20KE ClockLock and ClockBoost features and
also describes common applications for these features.
Clock Delay &
Skew
The delay from a clock pin to a register, especially for large devices, can
be significant enough to degrade both on- and off-chip performance.
Figure 1 shows the equation for the pin-to-pin clock-to-output delay (
t
CO
).
The clock delay (
t
CLOCK
) and clock skew (
t
SKEW
) parameters account for a
significant portion of the total clock-to-output delay in larger devices. By
reducing clock delay and clock skew, the ClockLock and ClockBoost
circuitry improves the device’s clock-to-output times.
2 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 1. APEX 20K & APEX 20KE Hold, Setup & Clock-to-Output Times
Clock skew—the difference between clock delays to different registers—
also increases the setup time indirectly. To ensure a zero hold time (
t
H
),
add a data delay to account for the longest clock delay to any register. This
delay must be long enough to ensure a zero hold time under fast process,
voltage, and temperature conditions. However, the added data delay also
increases the register’s setup time under slow process, voltage, and
temperature conditions. When a ClockLock signal feeds a register, the
signal bypasses the data delay element to the register, resulting in a
decreased setup time. Because clock skew and delay are reduced, the
register maintains a zero hold time.
As programmable logic devices (PLDs) become larger, clock delay and
skew can become a problem. Clock skew can also affect a board’s design.
To address these issues, designers can use either PLLs or delay-locked
loops (DLLs). Although both can reduce the skew within system clocks,
PLLs are more flexible than DLLs for frequency synthesis of system
clocks. In addition, DLLs are not capable of performing non-integer
scaling, and they cannot attenuate input jitter. In DLLs, all input jitter
propagates to the output and accumulates when the DLLs are cascaded.
Because PLLs can perform non-integer scaling, they are ideal for clock
multiplication and division applications.
DQ
DQ
data1
clock
data2
t
H
=
t
REG_H
+
t
CLOCK
+
t
SKEW
t
DATA
t
SU
=
t
REG_SU
+
t
DATA
t
CLOCK
t
SKEW
t
CO
=
t
CLOCK
+
t
SKEW
+
t
REG_CO
+
t
OUTPUT
Data
Delay
Data
Delay
Clock
Delay
Skew
Output
Delay
Output
Delay
Altera Corporation 3
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Table 1 shows the ClockLock features for APEX 20K and APEX 20KE
devices.
Notes:
(1) APEX 20K devices that support ClockLock and ClockBoost features are denoted by an “X” suffix in the ordering
code (e.g., EP20K400FC672-1X).
(2)
m
is an integer that ranges from 1 to 160.
(3) The quantity (
n
×
k
) can range from 1 to 280. A special multiplication rate is also provided for T1 to E1 frequency
conversion (i.e., 256/193), and E1 to T1 frequency conversion (i.e., 193/256).
(4) The EP20K300E device supports LVDS data transfer at up to 155 megabits per second (Mbps).
APEX 20K Devices
APEX 20K devices have one PLL that features ClockLock and ClockBoost
circuitry. This PLL can be instantiated by using the
altclklock
megafunction. APEX 20K devices support ClockBoost multiplication
circuitry, offering 1
×
, 2
×
, and 4
×
clock multiplication. Figure 2 shows the
ClockLock and ClockBoost circuitry block diagrams within the
altclklock
megafunction and its ports.
Table 1. APEX 20K & APEX 20KE ClockLock Features
Note (1)
Device Number
of PLLs ClockBoost
Feature Number of
External
Clock
Outputs
Number of
Feedback
Inputs
ClockShift T1/E1
Conversion LVDS
Clock LVDS
Data
EP20K100 1
1
×
, 2
×
, 4
×
–––
EP20K200 1
1
×
, 2
×
, 4
×
–––
EP20K400 1
1
×
, 2
×
, 4
×
–––
EP20K100E 2
m
/(
n
×
k
)
(2)
,
(3)
11
vvv
EP20K160E 2
m
/(
n
×
k
)
(2)
,
(3)
11
vvv
EP20K200E 2
m
/(
n
×
k
)
(2)
,
(3)
11
vvv
EP20K300E 4
m
/(
n
×
k
)
(2)
,
(3)
22
vvv
(4)
EP20K400E 4
m
/(
n
×
k
)
(2)
,
(3)
22
vvvv
EP20K600E 4
m
/(
n
×
k
)
(2)
,
(3)
22
vvvv
EP20K1000E 4
m
/(
n
×
k
)
(2)
,
(3)
22
vvvv
4 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 2. ClockLock & ClockBoost Circuitry in APEX 20K Devices
Note:
(1) This division is used only for the purpose of dividing down a 2
×
/4
×
clock1
to
obtain a 1
×
/2
×
/4
×
on
clock0
.
You can use a single output clock of 1
×
, 2
×
, 4
×
, or any combination of
output clocks. Table 2 describes the clock multiplication combinations
that the
altclklock
megafunction supports for APEX 20K devices.
The dedicated clock pin (
CLK2
) supplies the clock to the PLL and the
altclklock
megafunction. Adhere to the following guidelines when
using the
altclklock
megafunction in APEX 20K devices:
The inclock port must only be fed directly by the dedicated clock
input pin (CLK2) without inversion.
altclklock can only be used to clock positive or negative edge-
triggered registers in logic elements (LEs), I/O elements (IOEs), or
embedded system blocks (ESBs). IOE registers can only have single
clock polarity from a given altclklock output (i.e., IOE registers
must be all positive-edge triggered or all negative-edge triggered). If
both clock polarities are needed for IOE, use two PLL outputs.
The CLK2 pin that directly feeds the inclock port can also drive
other registers without the PLL. However, doing so makes the CLK1
pin and the clock1 port unavailable.
When two PLL outputs are used, the other clock pin (CLK1) cannot be
used.
÷ 1, 2, or 4
Phase
Comparator Voltage-Controlled
Oscillator
ClockBoost
altclklock Megafunction
inclock ÷ 1, 2, or 4 clock0
clock1
(1)
Table 2. APEX 20K Multiplication Factor Combinations
Clock 0 Clock 1 Input Frequency (MHz)
-1X Speed Grade -2X Speed Grade
1×2×25 to 180 25 to 170
1×, 2×4×16 to 90 16 to 100
1×, 2×, 4×4×10 to 48 10 to 34
Altera Corporation 5
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
You should connect the board clock trace to only the CLK2 pin for designs
that require two outputs from the altclklock megafunction. Figure 3
illustrates the valid clock connections for the PLL and global clock lines.
Figure 3. APEX 20K Dedicated Global Clock Pin Connections to PLL & Dedicated
Clock Lines
Table 3 shows the timing parameters for the APEX 20K ClockLock and
ClockBoost features for -1 speed-grade devices and Table 4 shows the
timing parameters for the APEX 20K ClockLock and ClockBoost features
for -2 speed-grade devices.
Table 3. APEX 20K ClockLock & ClockBoost Parameters for -1X Speed-Grade
Devices (Part 1 of 2)
Symbol Parameter Min Max Unit
fOUT Output frequency 25 180 MHz
fCLK1
(1) Input clock frequency (ClockBoost
clock multiplication factor equals 1) 25 180
(1) MHz
fCLK2 Input clock frequency (ClockBoost
clock multiplication factor equals 2) 16 90 MHz
fCLK4 Input clock frequency (ClockBoost
clock multiplication factor equals 4) 10 48 MHz
tINDUTY Input duty cycle 40 60 %
tOUTDUTY Duty cycle for
ClockLock/ClockBoost-generated
clock
40 60 %
fCLKDEV Input deviation from user
specification in the Quartus II
software (ClockBoost clock
multiplication factor equals 1) (2)
25,000
(3) PPM
tRInput rise time 5 ns
PLL
inclock
clock0
clock1
CLK2
CLK1
Dedicated
Clocks
6 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Notes:
(1) The PLL input frequency range for the EP20K100-1X device for 1× multiplication is
25 MHz to 175 MHz.
(2) All input clock specifications must be met. The PLL may not lock onto an incoming
clock if the clock specifications are not met, creating an erroneous clock within the
device.
(3) During device configuration, the ClockLock and ClockBoost circuitry is configured
first. If the incoming clock is supplied during configuration, the ClockLock and
ClockBoost circuitry locks during configuration, because the lock time is less than
the configuration time.
(4) The jitter specification is measured under long-term observation.
(5) If the input clock stability is 100 ps, tJITTER is 250 ps.
tFInput fall time 5 ns
tLOCK Time required for
ClockLock/ClockBoost to acquire
lock (4)
10 µs
tSKEW Skew delay between related
ClockLock/ClockBoost-generated
clocks
500 ps
tJITTER Jitter on ClockLock/ClockBoost-
generated clock (5) 200 ps
tINCLKSTB Input clock stability (measured
between adjacent clocks) 50 ps
Table 4. APEX 20K ClockLock & ClockBoost Parameters for -2X Speed –Grade
Devices (Part 1 of 2)
Symbol Parameter Min Max Unit
fOUT Output frequency 25 170 MHz
fCLK1 Input clock frequency (ClockBoost
clock multiplication factor equals 1) 25 170 MHz
fCLK2 Input clock frequency (ClockBoost
clock multiplication factor equals 2) 16 80 MHz
fCLK4 Input clock frequency (ClockBoost
clock multiplication factor equals 4) 10 34 MHz
tOUTDUTY Duty cycle for ClockLock/ClockBoost-
generated clock 40 60 %
fCLKDEV Input deviation from user specification
in the Quartus II software (ClockBoost
clock multiplication factor equals one)
(1)
25,000
(2) PPM
Table 3. APEX 20K ClockLock & ClockBoost Parameters for -1X Speed-Grade
Devices (Part 2 of 2)
Symbol Parameter Min Max Unit
Altera Corporation 7
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Notes:
(1) To implement the ClockLock and ClockBoost circuitry with the Quartus II
software, designers must specify the input frequency. The Quartus II software
tunes the PLL in the ClockLock and ClockBoost circuitry to this frequency. The
fCLKDEV parameter specifies how much the incoming clock can differ from the
specified frequency during device operation. Simulation does not reflect this
parameter.
(2) 25,000 parts per million (PPM) equates to 2.5% of input clock period.
(3) During device configuration, the ClockLock and ClockBoost circuitry is configured
before the rest of the device. If the incoming clock is supplied during configuration,
the ClockLock and ClockBoost circuitry locks during configuration because the
tLOCK value is less than the time required for configuration.
(4) The tJITTER specification is measured under long-term observation.
Table 5 lists the APEX 20K ClockLock pins and their functions.
tRInput rise time 5ns
tFInput fall time 5ns
tLOCK Time required for ClockLock/
ClockBoost to acquire lock
(3)
10 µs
tSKEW Skew delay between related
ClockLock/ ClockBoost-generated
clock
500 500 ps
tJITTER Jitter on ClockLock/ ClockBoost-
generated clock (4) 200 ps
tINCLKSTB Input clock stability (measured between
adjacent clocks) 50 ps
Table 4. APEX 20K ClockLock & ClockBoost Parameters for -2X Speed –Grade
Devices (Part 2 of 2)
Symbol Parameter Min Max Unit
Table 5. APEX 20K Device ClockLock Pins
Pin Name Pin Type Description I/O Standards
Supported (1)
CLK2 Input Dedicated pin that drives the ClockLock and
ClockBoost circuitry. 2.5-V I/O, LVCMOS,
LVTTL, 3.3-V PCI,
CMOS (2), TTL (2)
LOCK Output Optional pin that shows the status of the ClockLock
and ClockBoost circuitry. When the ClockLock and
ClockBoost circuitry is locked to the incoming clock
and generates an internal clock, LOCK is driven high.
LOCK remains high as long as the clock input remains
within specification.
8 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Notes:
(1) PCI: peripheral component interconnect.
(2) APEX 20K devices with a “V” suffix in their ordering code are 5.0-V tolerant.
APEX 20KE Devices
APEX 20KE devices incorporate multiple ClockLock circuits with
advanced features. These features include ClockLock circuitry, advanced
ClockBoost circuitry, LVDS support, ClockShift circuitry, and external
clock outputs with optional external feedback inputs.
Advanced ClockBoost Multiplication & Division
Each APEX 20KE PLL includes circuitry that provides clock synthesis for
two outputs using m/(n × k) and m/(n × v) scaling factors. When a PLL is
locked, the locked output clock aligns to the rising edge of the input clock.
The closed loop equation for Figure 3 gives an output frequency of
fCLOCK0 = (m/(n × k)) fIN and fCLOCK1 = (m/(n × v))fIN. This equation allows
the multiplication or division of clocks by a programmable number. The
Quartus II software automatically chooses the appropriate scaling factors
(m, n, k, and v) according to the frequency, multiplication, and division
values entered.
The scaling multiplication of APEX 20KE PLLs allows for a wide range of
user-defined multiplication and division ratios that are not possible with
DLLs. For example, if a frequency scaling factor of 3.75 is needed for a
given input clock, you can enter a multiplication factor of 15 and a
division factor of four. Because this advanced ClockBoost scaling can be
performed with a single PLL, you do not need to cascade PLL outputs.
All APEX 20KE PLLs are capable of converting between T1 and E1 clock
frequencies. The T1 telecommunications standard uses a 1.544-MHz
clock, and the E1 telecommunications standard uses a 2.048-MHz clock.
APEX 20KE PLLs can convert a T1 frequency to an E1 frequency and vice
versa.
LVDS Interface
In EP20K400E and larger devices, two of the ClockLock PLLs (PLL3 and
PLL4) can be configured for use in LVDS transmitter and receiver
interfaces. When the PLL is configured to use LVDS, the I/O clock can be
multiplied to support high-speed data transfer rates and to convert
between LVDS and CMOS data. These PLLs interface with the
APEX 20KE LVDS receiver and LVDS transmitter blocks.
Altera Corporation 9
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
When used for LVDS transmitter and receiver modes, PLLs 3 and 4 use
connections shown at the top of the Figure 7. These modes require the use
of the ALTLVDS megafuntion.
fSee Application 120 (Using LVDS in APEX 20KE Devices) for more
information on LVDS.
External Clock Outputs
In EP20K300E and larger devices, low-jitter external clocks,
CLKLK_OUT1P and CLKLK_OUT2P, are available for external clock
sources. In EP20K30E, EP20K60E, EP20K100E, EP20K160E, and
EP20K200E devices, one external clock, CLKLK_OUT2P, is available for an
external clock source. The CLKLK_OUT1P signal originates from PLL 1; the
CLKLK_OUT2P signal originates from PLL 2. Other devices on the board
can use these outputs as clock sources.
External clock outputs are available in three modes:
Zero Delay Buffer—The external clock output pin is phase aligned
with the clock input pin for zero delay. Phase shift is not allowed in
this configuration. Clock division is possible on the external clock
output in this configuration. Multiplication is possible on the
remaining PLL output that is not driven off-chip. The altclklock
megafunction’s MegaWizard® Plug-In should be used to verify
possible clock settings.
External Feedback—The external feedback input pin is phase aligned
with the clock input pin. By aligning these clocks, you can actively
remove clock delay and skew between devices. This mode has the
same restrictions as the zero delay buffer.
Normal Mode—The external clock output pin will have phase delay
relative to the clock input pin. If an internal clock is used in this mode,
it will be phase aligned to the input clock pin.
ClockShift Circuitry
APEX 20KE PLLs have ClockShift circuitry that provides programmable
clock delay and phase shift. The user enters the desired phase shift. Phase
shifts of 90˚, 180˚, and 270˚ can be implemented exactly. Other phase shift
or delay shift values (in time units) are available with a 0.5 ns to 1.0 ns
resolution range. This resolution varies with frequency input and the
user-entered multiplication and division factors. The ClockShift circuitry
can only be used on a multiplied or divided clock if the input and output
frequency have an integer multiple relationship (i.e., fIN/fOUT or fOUT/fIN
must be an integer). The PLL ClockShift circuitry is only available in
Normal mode.
10 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Clock Enable Signal
APEX 20KE PLLs have a CLKLK_ENA pin for enabling and disabling all of
the device PLLs. When the CLKLK_ENA pin is high, the PLL drives the
clock0 and clock1 ports. When the CLKLK_ENA pin is low, the clock0
and clock1 ports are driven by GND and all of the PLLs go out of lock.
When the CLKLK_ENA pin goes high again, the PLL must relock.
The individual enable port on the altclklock megafunction is an
all-or-none control signal. If the enable port is used for any altclklock
instance, all other instances must use the enable port and connect to the
same pin. If the port is used, the pin connected to the enable ports must be
the CLKLK_ENA dedicated pin.
The inclocken input port on the altclklock megafunction should be
used for all designs. If the CLKLK_ENA control is needed by the designer,
it must be brought to the CLKLK_ENA input pin. The Quartus II software
automatically assigns the pin location to this dedicated function pin.
If the CLKLK_ENA control is not needed by the user in Zero Delay Buffer
and Normal modes, the inclocken port should not be connected to an
input pin in the design. On the board, this pin can be connected to VCC or
GND since it will be a floating input.
If the CLKLK_ENA control is not needed by the user in External Feedback
mode, the inclocken port must be connected to an input pin. On the
board, the user must connect this pin directly to the INIT_DONE pin. The
INIT_DONE option must be set in the Device & Pin Options tab of the
Compiler Settings > Chips & Devices dialog box (Processing menu). If
system control over the CLKLK_ENA pin is needed in External Feedback
mode, an open-drain control signal can be used in a wire-ANDed
configuration with the open-drain INIT_DONE pin. Figure 4 demonstrates
how this should be connected.
Altera Corporation 11
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 4. Wire-ANDing with the Open-Drain INIT_DONE Pin
Lock Signals
The APEX 20KE ClockLock PLL circuits support individual LOCK signals.
The LOCK signal drives high when the PLL has locked onto the input
clock. LOCK remains high as long as the input remains within
specification. It will go low if the input is out of specification. When using
two clock outputs from a PLL, the two outputs may become valid at
different times. This difference is caused by the difference in divider ratios
between the two outputs. A LOCK pin is optional for each PLL used in
APEX 20KE devices; when not used, they are I/O pins. This signal is not
available internally. If this signal is used in the design, it must be fed back
in with an input pin.
Before configuration, all PLL circuits are disabled and powered down.
During configuration, the PLLs are disabled. When the device goes into
user mode, the lock time is measured from the CLKLK_ENA rising edge to
the LOCK rising edge.
During device configuration, the I/O standard of each I/O pin has not
been set. For this reason, the PLL does not lock during configuration.
The LOCK signal indication also has separate programmable latency
controls for LOCK assertion and deassertion. Users can select one of two
multipliers, 1 or 5, to indicate a small or large latency. The number of half
cycles for indication is dependent on the multiplication/division ratio and
input frequency. Depending on these factors, the low end of latency
ranges from 1 to 16 half-clock cycles; the high end of latency ranges from
5 to 80 half-clock cycles.
The APEX 20KE ClockLock circuits (general purpose PLLs) are
instantiated using the altclklock megafunctions. Figure 5 shows the
ClockLock and ClockBoost circuitry in APEX 20KE devices.
CLKLK_ENA
INIT_DONE
VCC
Optional Control
Signal
12 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 5. ClockLock & ClockBoost Circuitry in APEX 20KE Devices
Each of the dedicated global clock pins in EP20K300E, EP20K400E,
EP20K600E, EP20K1000E, and EP20K1500E devices (CLK1P, CLK2P,
CLK3P, CLK4P) supplies the clock to a PLL in general purpose mode. Each
altclklock instance represents a single general-purpose PLL
instantiation. The altclklock megafunction in APEX 20KE devices
must adhere to the following guidelines:
It can only be fed directly by a dedicated clock input pin without
inversion.
altclklock can only be used to clock positive or negative edge-
triggered registers in LEs, IOEs, or ESBs. IOE registers can only have
single clock polarity from a given altclklock output (i.e., IOE
registers must be all positive-edge triggered or all negative-edge
triggered). If both clock polarities are needed for IOE, use two PLL
outputs.
The allowable frequency input range is 1.5 to 420 MHz, depending on
the I/O standard (see Table 7).
The allowable frequency output range on clock0 is 1.5 to 420 MHz,
depending on the I/O standard for the external clock out and/or the
internal max frequency shown in Table 7.
The allowable frequency output range on clock1 is 12.5 to 420 MHz,
depending on the I/O standard for the external clock out and/or the
internal max frequency shown in Table 7.
Phase shifting is only possible on a multiplied clock if the input and
output frequency have an integer-multiple relationship (i.e., fIN/fOUT
or fOUT/fIN must be an integer).
Phase shifting, using degree or time units, will delay or lag the output
clock with respect to the input clock (see Figure 6).
The ratio of clock_boost to clock_divide cannot be greater than
280. A special scaling ratio of 256/193 or 193/256 is allowed for
T1/E1 or E1/T1 clock rate conversion, respectively.
Phase
Comparator Voltage-Controlled
Oscillator
altclklock Megafunction
inclock clock0
clock1
÷ n
÷ m
ClockShift
Circuitry
÷ k
÷ v
fbin
Altera Corporation 13
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 6. Phase & Delay Shifting Using APEX 20KE PLLs
Several conditions exist that govern the relationship between the input
frequency, m, n, k, v, and phase shift values. The altclklock
MegaWizard Plug-In automatically sets the m, n, k, and v dividers to
satisfy these equalities and to accommodate the phase shift entered and
the clock multiplication or division. The MegaWizard Plug-In verifies the
validity of the settings and reports if a multiplication/division frequency
ratio is not valid.
Each PLL can be driven by a dedicated clock pin and bypassed
simultaneously. The CLK3P and CLK4P pins can feed two PLLs each, or
two altclklock instances. This capability is useful for applications that
need both phase-shifted and non-phase-shifted versions of the clock.
Because the eight PLL outputs are shared among four possible dedicated
global clock lines, certain combinations of multiple altclklock
instances and their output connections are not possible. The Quartus II
software uses different PLLs (i.e., 1, 2, 3, 4) based on pin assignments
made to the dedicated global clock pin that feeds the altclklock
megafunction. Figure 7 illustrates the valid clock connections for the PLL
and the dedicated global clock lines in these devices. This figure should be
used to determine whether a design clocking scheme is valid in terms of
APEX 20KE PLL and clock connections. For example, in an EP20K400E
device, CLK4P can feed PLL 4 and PLL 2 simultaneously; however, only a
single internal output from each PLL can be used, because the four
possible outputs feed two global clock lines.
14 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 7. Dedicated Global Clock Pin Connections to PLL & Dedicated Clock Lines for EP20K300E,
EP20K400E, EP20K600E, EP20K1000E & EP20K1500E Devices
Notes:
(1) For EP20K400E, EP20K600E, EP20K1000E, and EP20K1500E PLL 4 can be used in only one of two possible modes,
general purpose mode or ALTLVDS_TX transmitter mode. Connections that apply to the chosen mode are shown
above and are exclusive to that mode. Only one mode can be used at a time for PLL 4. EP20K300E PLL 4 can only
be used in general purpose mode.
(2) For EP20K400E, EP20K600E, EP20K1000E, and EP20K1500E PLL 3 can be used in only one of two possible modes,
general purpose mode or ALTLVDS_RX receiver mode. Connections that apply to the chosen mode are shown above
and are exclusive to that mode. Only one mode can be used at a time for PLL 3. EP20K300E PLL3 can only be used
in general purpose mode.
(3) This PLL output is a high-speed CMOS/LVDS interface clock that feeds the LVDS transmitter block.
(4) This PLL output is a high-speed LVDS/CMOS interface clock that feeds the LVDS receiver block.
For EP20K30E, EP20K60E, EP20K100E, EP20K160E, and EP20K200E
devices, the CLK4P and CLK2P dedicated clock pins supply the clock to
two PLLs. These PLLs have the same usage guidelines as the EP20K400E
device and larger device’s PLLs, with the exception of some PLL
connections. You can use all four possible PLL output clocks that are
shared among four dedicated clock lines. If you use all of the outputs, the
CLK3P and CLK1P pins cannot be used.
Figure 8 illustrates the valid clock connections for the PLL and the global
clock lines in these devices. Use Figure 8 to determine whether a design
clocking scheme is valid in terms of PLL and clock connections. The
altclklock megafunction port connections should follow the usage
guidelines illustrated in Figures 7 and 8.
4 Dedicated
Clocks
CLKLK_FB2p
CLKLK_OUT2p
CLKLK_FB1p
CLKLK_OUT1p
CLK3p
CLK1p
CLK4p
G1
G2
G3
LVDSRXINCLK1p/n
LVDSTXINCLK1p/n
LVDSTXOUTCLK1p/n
CLK2p
(1)
(3) (4)
(2)
tx_outclock
PLL4
tx_inclock
clock1
clock0
PLL2
inclock
fbin fbin
rx_outclock
PLL3
rx_inclock
clock1
clock0
PLL1 inclock
G4
G3
G2
G1
clock1
clock0
PLL4
inclock
General Purpose Mode
Transmitter Mode
(1)
(1)
1x
clock1
clock0
PLL3
inclock
Receiver Mode
General Purpose Mode
(2)
Altera Corporation 15
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 8. Dedicated Global Clock Pin Connections to PLL & Dedicated Clock Lines for EP20K30E, EP20K60E,
EP20K100E, EP20K160E & EP20K200E Devices
Table 6 shows the APEX 20KE ClockLock and ClockBoost parameters,
and Table 7 shows the APEX 20KE Clock Input and Output parameters.
4 Dedicated
Clocks
CLKLK_FB2p
CLKLK_OUT2p
CLK4p
CLK2p
1×
clock1
clock0
PLL4
inclock
clock1
clock0
PLL2
inclock
fbin
G4
G3
G2
G1
CLK3p
CLK1p
Table 6. APEX 20KE ClockLock & ClockBoost Parameters Note (1)
Symbol Parameter Condition Min Typ Max Unit
tRInput rise time 5ns
tFInput fall time 5ns
tINDUTY Input duty cycle 40 60 %
tINJITTER Input jitter peak-to-peak 2% of input
period peak-to-
peak
tOUTJITTER Jitter on ClockLock or ClockBoost-
generated clock 0.35% of
output period RMS
tOUTDUTY Duty cycle for ClockLock or
ClockBoost-generated clock 45 55 %
tLOCK (2), (3) Time required for ClockLock or
ClockBoost to acquire lock 40 µs
16 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Table 7. APEX 20KE Clock Input and Output Parameters Note (1)
Symbol Parameter I/O Standard -1X Speed Grade -2X Speed Grade Units
Min Max Min Max
fIN (4), (5),
(5) Input clock frequency 3.3-V LVTTL 1.5 290 1.5 257 MHz
2.5-V LVTTL 1.5 281 1.5 250 MHz
1.8-V LVTTL 1.5 272 1.5 243 MHz
GTL+ 1.5 303 1.5 261 MHz
SSTL-2 Class I 1.5 291 1.5 253 MHz
SSTL-2 Class II 1.5 291 1.5 253 MHz
SSTL-3 Class I 1.5 300 1.5 260 MHz
SSTL-3 Class II 1.5 300 1.5 260 MHz
LVDS 1.5 420 1.5 350 MHz
fVCO (5) Voltage controlled oscillator
operating range 200 500 200 500 MHz
fCLOCK0 Clock0 PLL output frequency for
internal use 1.5 335 1.5 200 MHz
fCLOCK1 Clock1 PLL output frequency for
internal use 12.5 335 20 200 MHz
fCLOCK0_EXT
(4), (5), (5) Output clock frequency for external
clock0 output 3.3-V LVTTL 1.5 245 1.5 226 MHz
2.5-V LVTTL 1.5 234 1.5 221 MHz
1.8-V LVTTL 1.5 223 1.5 216 MHz
GTL+ 1.5 205 1.5 193 MHz
SSTL-2 Class I 1.5 158 1.5 157 MHz
SSTL-2 Class II 1.5 142 1.5 142 MHz
SSTL-3 Class I 1.5 166 1.5 162 MHz
SSTL-3 Class II 1.5 149 1.5 146 MHz
LVDS 1.5 420 1.5 350 MHz
fCLOCK1_EXT
(4), (5), (5) Output clock frequency for external
clock1 output 3.3-V LVTTL 12.5 245 20 226 MHz
2.5-V LVTTL 12.5 234 20 221 MHz
1.8-V LVTTL 12.5 223 20 216 MHz
GTL+ 12.5 205 20 193 MHz
SSTL-2 Class I 12.5 158 20 157 MHz
SSTL-2 Class II 12.5 142 20 142 MHz
SSTL-3 Class I 12.5 166 20 162 MHz
SSTL-3 Class II 12.5 149 20 146 MHz
LVDS 12.5 420 20 350 MHz
Altera Corporation 17
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Notes to tables:
(1) All input clock specifications must be met. The PLL may not lock onto an incoming clock if the clock specifications
are not met, creating an erroneous clock within the device.
(2) The maximum lock time is 40 µs or 2000 input clock cycles, whichever occurs first.
(3) Before configuration, the PLL circuits are disabled and powered down. During configuration, the PLLs are still
disabled. The PLLs begin to lock once the device is in the user mode. If the clock enable feature is used, lock begins
once the CLKLK_ENA pin goes high in user mode.
(4) For the external feedback mode, the maximum clock frequency is either 165 MHz or the maximum clock output
according to the I/O standard, whichever is smaller. For the EP20K400E device, the maximum external clock
frequency for the external feedback mode is 124 MHz.
(5) For external feedback mode, the clock out, clock in, feedback input must have the same I/O standard.
(6) For zero delay buffer mode, the clock out and clock in must have the same I/O standard.
(7) The PLL voltage-controlled oscillator (VCO) operating range is wide enough to support the device’s maximum
LVDS data rate when in LVDS mode.b
Table 8 shows the APEX 20KE device LVDS mode PLL Parameters for
EP20K400E and EP20K600E devices and Table 9 shows the APEX 20KE
LVDS Mode PLL Parameters for EP20K1000E and EP20K1500E
devices.
Table 8. EP20K400E & EP20K600E LVDS Mode PLL Parameters Note (1)
Symbol Parameter Mode -1X Speed Grade -2X Speed Grade Units
Min Typ Max Min Typ Max
tCLVDS receiver/transmitter
input clock period
×8 9.52 33 11.43 33 ns
×7 9.52 33 11.43 33 ns
×4 5.71 20 6.88 20 ns
fINLVDS LVDS receiver/transmitter
input clock frequency
×8 30 105 30 87.5 MHz
×7 30 105 30 87.5 MHz
×4 50 175 50 145.25 MHz
fLVDSDR Maximum LVDS data
transfer rate
×8 240 840 240 700 Mbps
×7 210 735 210 612.5 Mbps
×4 200 700 200 581 Mbps
Input Jitter
(peak-to-
peak)
Peak-to-peak input Jitter
on input clock All 2% of tC2% of tCns
Output
Jitter
(RMS)
RMS output jitter in LVDS
mode (2), (3) All 0.25% of
tC
0.25% of
tC
ns
tDUTY Duty cycle on LVDS
transmitter output clock All 49 50 51 49 50 51 %
tLOCK Lock time for LVDS
transmitter and receiver
PLLs
All 5 5 µs
18 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Notes to tables:
(1) The PLL voltage-controlled oscillator (VCO) operating range is wide enough to support the device’s maximum
LVDS data rate when in LVDS mode.
(2) This assumes an input clock with 5 ps of input jitter
(3) This jitter is for both the receiver and the transmitter LVDS PLLs cascaded together. The jitter for the receiver or
transmitter PLL will be less.
Table 9. EP20K1000E and EP20K1500E LVDS Mode PLL Parameters Note (1)
Symbol Parameter Mode -1X Speed Grade -2X Speed Grade Units
Min Typ Max Min Typ Max
tCLVDS receiver/transmitter
Input clock period
×8 10.67 33 12.80 33 ns
×7 9.52 33 11.43 33 ns
×4 5.71 20 6.88 20 ns
fINLVDS LVDS receiver/transmitter
Input clock frequency
×8 30 93.7 30 78.125 MHz
×7 30 105 30 87.5 MHz
×4 50 175 50 145.25 MHz
fLVDSDR Maximum LVDS data
transfer rate
×8 240 750 240 625 Mbps
×7 210 735 210 612.5 Mbps
×4 200 700 200 581 Mbps
Input Jitter
(peak-to-
peak)
Peak-to-peak Input Jitter
on input clock All 2% of tC2% of tCns
Output
Jitter
(RMS)
RMS Output Jitter in LVDS
mode (2), (3) All 0.25% of
tC
0.25% of
tC
ns
tDUTY Duty cycle on LVDS
transmitter output clock All 49 50 51 49 50 51 %
tLOCK Lock time for LVDS
transmitter and receiver
PLLs
All 5 5 µs
Altera Corporation 19
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Table 10 lists the APEX 20KE ClockLock pins and their function.
Note:
(1) This pin is available in EP20K400E, EP20K600E, EP20K1000E, and EP20K1500E devices only.
Board Layout Each PLL uses its own VCC and GND pins. APEX 20K devices have one pair
of VCC and GND pins for the ClockLock and ClockBoost circuitry.
APEX 20KE devices use a VCC and GND pair for each PLL and each clock
output pin. Separate VCC and GND pins and external clock outputs reduce
jitter by isolating the output pin from adjacent switching pins. It also
minimizes any ground bounce or VCC sag effects from nearby switching
outputs.
Table 10. APEX 20KE Device ClockLock Pins
Pin Name Pin Type Description I/O Standards
Supported
CLKp[1..4] Input Dedicated pins that drive the PLL clock inputs. CLK3p
and CLK4p drive PLL3 and PLL4, respectively, for
general-purpose mode only.
1.8-V I/O, 2.5-V I/O,
AGP, CTT, HSTL,
LVCMOS, LVDS,
LVPECL, LVTTL,
GTL+, 3.3-V PCI,
3.3-V PCI-X, SSTL-2,
SSTL-3
CLKLK_FB Input Dedicated pins that allow external feedback to the
PLLs.
CLKLK_OUT Output Dedicated clock output that allows the PLL output to
be driven off-chip.
LVDSTXINCLK1p/n
LVDSRXINCLK1p/n
(1)
Input Dual-purpose I/O pins that drive the PLL clock input in
LVDS mode for LVDS/CMOS data conversion. LVDS
LVDSTXOUTCLK1p/n
(1) Output LVDS clock output that allows the PLL to drive the
LVDS 1× clock off-chip in LVDS mode. LVDS output
data is synchronized to this clock. These pins are
dual-purpose I/O pins.
LOCK Output Optional pin that shows the status of the ClockLock
and ClockBoost circuitry. When the ClockLock and
ClockBoost circuitry is locked to the incoming clock
and generates an internal clock, LOCK is driven high.
LOCK remains high as long as the clock input remains
within specification.
1.8-V I/O, 2.5-V I/O,
LVCMOS, LVTTL,
3.3-V PCI
20 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Table 11 shows the power pins required for APEX 20K and APEX 20KE
devices.
The ClockLock circuits contain analog components, which may be
sensitive to noise generated by digital components. Voltage fluctuations
on the power and ground planes on the board, such as ground bounce and
VCC sag, directly affects clock jitter. To avoid excessive jitter, the designer
must use proper supply decoupling.
All devices with ClockLock circuitry have special VCC and GND pins,
which provide power to the PLL and its dedicated output pin. The power
and ground connected to these pins must be isolated from the power and
ground to the rest of the APEX device or to any other digital devices.
These pins are named VCC_CKLK, GND_CKLK, VCC_CKOUT and
GND_CKOUT. The pin file generated by the Quartus II software and the
APEX 20K Device Family Data Sheet pin tables identify these pins.
Table 11. Power Pin Requirements for APEX 20K & APEX 20KE ClockLock PLL Features
Device Pin Name Description
EP20K100
EP20K200
EP20K400
VCC_CKLK
GND_CKLK
Power and ground pins for the ClockLock and ClockBoost PLL circuitry. To
ensure noise resistance, the power and ground supply to the PLL should be
isolated from the power and ground to the rest of the device. VCC_CKLK
pins have the same specifications as VCCINT and should be connected to
a 2.5 V supply, even if the PLL is not used.
EP20K60E
EP20K100E
EP20K160E
EP20K200E
VCC_CKLK2
VCC_CKLK4
GND_CKLK2
GND_CKLK4
Power and ground pins for the ClockLock and ClockBoost PLL circuitry. To
ensure noise resistance, the power and ground supply to the PLL should be
isolated from the power and ground to the rest of the device. VCC_CKLK
pins have the same specifications as VCCINT and should be connected to
a 1.8 V supply, even if the PLL is not used.
VCC_CKOUT2
GND_CKOUT2
Power and ground pins for the external clock output pins (CLKLK_OUT).
These pins supply the VCCIO and GNDIO for the CLKLK_OUT pins.
VCC_CKOUT pins have the same specifications as VCCIO and should be
connected to a VCCIO supply even if the external clock is not used.
EP20K300E
EP20K400E
EP20K600E
EP20K1000E
EP20K1500E
VCC_CKLK[4..1]
GND_CKLK[4..1]
Power and ground pins for the ClockLock and ClockBoost PLL circuitry. To
ensure noise resistance, the power and ground supply to the PLL should be
isolated from the power and ground to the rest of the device. VCC_CKLK
pins have the same specifications as VCCINT and should be connected to
a 1.8 V supply even if the PLL is not used.
VCC_CKOUT1
VCC_CKOUT2
GND_CKOUT1
GND_CKOUT2
Power and ground pins for the external clock output pins (CLKLK_OUT).
These pins supply the VCCIO and GNDIO for the CLKLK_OUT pins.
VCC_CKOUT pins have the same specifications as VCCIO and should be
connected to a VCCIO level even if the external clock is not used.
Altera Corporation 21
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
One of following recommended board layout techniques can be used:
Use separate VCC_CKLK, GND_CKLK, VCC_CKOUT and GND_CKOUT
power planes in board layout.
The designer of a mixed-signal system will have already partitioned the
system into analog and digital sections, each with its own power and
ground planes on the board. In this case, the VCC_CKLK and GND_CKLK
pins can be connected to the analog power and ground planes.
VCC_CKOUT requires a digital power plane connection.
Partition the VCCINT, GNDINT, VCCIO, and GNDIO planes to include
islands for VCC_CKLK, GND_CKLK, VCC_CKOUT, and GND_CKOUT
respectively.
For fully digital systems that do not already have separate analog power
and ground planes on the board, adding two or four new planes to the
board may be prohibitively expensive. Instead, the board designer can
create islands for the VCC_CKLK/GND_CKLK and
VCC_CKOUT/GND_CKOUT. Figure 9 shows an example board layout with
an analog power island. This would need to be done for
VCC_CKLK/GND_CKLK and VCC_CKOUT/GND_CKOUT.
If the CLKLK_OUT pins are not used, isolation for VCC_CKOUT is not
necessary.
Figure 9. Board Layout for PLL VCC & GND Islands
APEX Device
Digital Power and GND Planes
Analog Power and Ground Island
Dielectric Width at
least 100 mil
22 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Each of the VCC_CKLK/GND_CKLK and VCC_CKOUT/GND_CKOUT pairs
should be decoupled with a 2.2-µF, 0.1-µF and 0.01-µF parallel
combination of ceramic capacitors located as close as possible to the
APEX 20K or APEX 20KE device. Place a 10-µF tantalum capacitor
immediately adjacent to the location where the power-supply lines for the
PLLs come into the PCB along with a ferrite bead. Values depend on the
frequency of the application. Refer to the ferrite bead manufacturer
frequency specifications. See Figure 10. If PLLs are used in LVDS mode,
the VCC_CKLK4/GND_CKLK4 and VCC_CKLK3/GND_CKLK3 pins should
be decoupled with 2.2-µF, 0.1-µF, 0.01-µF, and 0.001-µF parallel
capacitors.
Figure 10 shows the general purpose PLL power supply decoupling.
Figure 10. General Purpose PLL Power Supply Decoupling
Notes:
(1) The VCC_CKOUT and GND_CKOUT pins are only available on APEX 20KE devices.
(2) If PLLs are used in LVDS mode, the VCC_CKLK4/GND_CKLK4 and VCC_CKLK3/GND_CKLK3 pins should be
decoupled with an additional 0.001-µF parallel capacitor.
Software
Support
The ClockShift and ClockBoost features, as well as other PLL feature
settings, are controlled by the altclklock parameters. This section
describes the ports and parameters for the altclklock megafunction
and shows the function prototype and component declarations.
0.1 µF
0.01 µF
V
CCINT
GND
VCC_CKLK
GND_CKLK
VCC_CKOUT (1)
GND_CKOUT (1)
APEX Device
10 µF10 µF
VCCIO GNDIO
0.1 µF
2.2 µF
0.01 µF
2.2 µF
(2)
Altera Corporation 23
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
altclklock Ports & Parameters
Tables 12 through 14 list the altclklock input port, output port, and
parameter descriptions.
Table 12. altclklock Input Port Descriptions
Name Required Description Comments
inclock Yes Clock port that
drives the
ClockLock PLL
inclocken No PLL enable
signal When the inclocken port is high, the PLL drives the clock0 and
clock1 ports. When the inclocken port is low, the clock0 and
clock1 ports drive out GND and the PLL goes out of lock. When the
inclocken port goes high again, the PLL must relock. This port is
not available for APEX 20K devices.
fbin No External
feedback input
for PLL
To complete the feedback loop, there must be a board-level
connection between the fbin pin and the PLLs external clock
output pin. This port is not available for APEX 20K devices.
Table 13. altclklock Output Port Descriptions
Name Required Description Comments
clock0 No First output
clock of the PLL In APEX 20K devices, if the pin driving the PLLs inclock port is
used elsewhere in the design, you can use only the PLLs clock0
output port. No fit is possible if you simultaneously use the clock0
port, the clock1 port, and the pin driving the PLLs inclock port.
In APEX 20KE devices, you can use the clock0 port, the clock1
port, and the pin driving the PLLs inclock port. If, however, you are
using the PLL to generate only one clock signal, you should use the
clock1 port to give the Compiler added flexibility when fitting the
PLL.
clock1 No Second output
clock of the PLL In APEX 20K devices, if the pin driving the PLLs inclock port is
used elsewhere in the design, you can use only the PLLs clock0
output port. No fit is possible if you simultaneously use the clock0
port, the clock1 port, and the pin driving the PLLs inclock port.
In APEX 20KE devices, you can use the clock0 port, the clock1
port, and the pin driving the PLLs inclock port. If, however, you are
using the PLL to generate only one clock signal, you should use the
clock1 port to give the Compiler added flexibility when fitting the
PLL.
locked No Status of the
PLL When the PLL is locked, this signal is VCC. When the PLL is out of
lock, this signal is GND. The locked port may pulse high and low while
the PLL is in the process of achieving lock.
24 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Table 14. altclklock Parameter Descriptions (Part 1 of 6)
Name Type Required Description
INCLOCK_PERIOD Integer Yes Specifies the period of the inclock port in ps. This
parameter is not required if a clock setting is specified
for the inclock port.
INCLOCK_SETTINGS String No Specifies the clock setting assignment to be used with
the inclock port. If the INCLOCK_SETTINGS
parameter is specified, the INCLOCK_PERIOD
parameter is not required and is ignored. If omitted,
the default is "UNUSED".
VALID_LOCK_CYCLES Integer No Specifies the number of half-clock cycles for which
the clock0 and clock1 ports must be locked before
the locked pin goes high. This parameter is used only
for third-party and functional simulations. To compute
the actual number of half-clock cycles for which the
clock0 and clock1 ports must be locked before the
locked pin goes high, the Compiler uses the value of
the VALID_LOCK_MULTIPLIER parameter. The
computed value replaces any manually-specified
values for the VALID_LOCK_CYCLES parameter.
Altera recommends creating the PLL with the
MegaWizard Plug-In Manager to obtain and select,
based on the design, a close approximation of the
value of the VALID_LOCK_CYCLES parameter. The
MegaWizard Plug-In Manager automatically specifies
values for both the VALID_LOCK_CYCLES and
VALID_LOCK_MULTIPLIER parameters. If omitted,
the default is five. This parameter is available only in
APEX 20KE devices.
Altera Corporation 25
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
INVALID_LOCK_CYCLES Integer No Specifies the number of half-clock cycles for which
the clock0 and clock1 ports must be out of lock
before the locked pin goes low. This parameter is
used only for third-party and functional simulations.
To compute the actual number of half-clock cycles for
which the clock0 and clock1 ports must be out of
lock before the locked pin goes low, the Compiler
uses the value of the INVALID_LOCK_MULTIPLIER
parameter. The computed value replaces any
manually specified values for the
INVALID_LOCK_CYCLES parameter. Altera
recommends creating the PLL with the MegaWizard
Plug-In Manager to obtain and select, based on the
design, a close approximation of the value of the
INVALID_LOCK_CYCLES parameter. The
MegaWizard Plug-In Manager automatically specifies
values for both the INVALID_LOCK_CYCLES and
INVALID_LOCK_MULTIPLIER parameters. If
omitted, the default is five. This parameter is available
only in APEX 20KE devices.
VALID_LOCK_MULTIPLIER Integer No Specifies the scaling factor, in half-clock cycles, for
which the clock0 and clock1 ports must be locked
before the locked pin goes high. The Compiler uses
the value of the VALID_LOCK_MULTIPLIER
parameter to compute the value of the
VALID_LOCK_CYCLES parameter. Altera
recommends creating the PLL with the MegaWizard
Plug-In Manager to obtain and select, based on the
design, a close approximation of the scaling factor.
The MegaWizard Plug-In Manager automatically
specifies values for both the VALID_LOCK_CYCLES
and VALID_LOCK_MULTIPLIER parameters. This
parameter is required if the locked port is connected.
Values are one and five. If omitted, the default is five.
This parameter is available only in APEX 20KE
devices.
Table 14. altclklock Parameter Descriptions (Part 2 of 6)
Name Type Required Description
26 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
INVALID_LOCK_MULTIPLIER Integer No Specifies the scaling factor, in half-clock cycles, for
which the clock0 and clock1 ports must be out of
lock before the locked pin goes low. The Compiler
uses the value of the INVALID_LOCK_MULTIPLIER
parameter to compute the value of the
INVALID_LOCK_CYCLES parameter. Altera
recommends creating the PLL with the MegaWizard
Plug-In Manager to obtain and select, based on the
design, a close approximation of the scaling factor.
The MegaWizard Plug-In Manager automatically
specifies values for both the
INVALID_LOCK_CYCLES and
INVALID_LOCK_MULTIPLIER parameters. This
parameter is required if the locked port is connected.
Values are one and five. If omitted, the default is five.
This parameter is available only in APEX 20KE
devices.
Table 14. altclklock Parameter Descriptions (Part 3 of 6)
Name Type Required Description
Altera Corporation 27
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
OPERATION_MODE String No In Normal mode, the phase shift is measured
between the internal clock network and the dedicated
inclock pin. If the PLL also feeds an external
CLKLK_OUT pin, a phase difference results at the
output of the external CLKLK_OUT pin due to the time
delay it introduces. In Zero Delay Buffer mode, the
PLL behaves as a zero-delay buffer of the input clock.
The PLL must be connected to an external
CLKLK_OUT pin, and the output of the external
CLKLK_OUT pin is in phase with the dedicated
inclock pin. If the clock0 port is used to drive the
external CLKLK_OUT pin, the CLOCK0_BOOST
parameter must be unused or set to one; if the
clock1 port is used to drive the external CLKLK_OUT
pin, the CLOCK1_BOOST parameter must be unused
or set to one. If the PLL is also used to drive the
internal clock network, a corresponding phase shift of
that network results. The programmable phase shift
feature is not available in this mode. Thus, the
OUTCLOCK_PHASE_SHIFT parameter must be
unused or set to zero. In External Feedback mode,
the fbin port must be used, and a board-level
connection between the external CLKLK_OUT pin and
the CLKLK_FB pin must exist. In addition, the PLL
adjusts its output to cause the signal observed at the
CLKLK_FB pin to be synchronized with the input
clock. If the PLL is also used to drive the internal clock
network, a corresponding phase shift on that network
results. Values are NORMAL, ZERO_DELAY_BUFFER,
and EXTERNAL_FEEDBACK. If omitted, the default is
NORMAL. This parameter is available only in
APEX 20KE devices.
CLOCK0_BOOST Integer No Specifies the integer multiplication factor, which must
be greater than zero, for the clock0 port with respect
to the input clock frequency. This parameter can be
specified only if the clock0 port is used; however, it
is not required if a clock setting is specified for the
clock0 port. The value for this parameter must be
one, two, or four for APEX 20K devices. Create the
PLL with the MegaWizard Plug-In Manager to
calculate the value for this parameter for APEX 20KE
devices. If omitted, the default is one.
Table 14. altclklock Parameter Descriptions (Part 4 of 6)
Name Type Required Description
28 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
CLOCK0_DIVIDE Integer No Specifies the integer division factor, which must be
greater than zero, for the clock0 port with respect to
the input clock frequency. This parameter can be
specified only if the clock0 port is used; however, it
is not required if a clock setting is specified for the
clock0 port. The setting for this parameter must be
one for APEX 20K devices. Create the PLL with the
MegaWizard Plug-In Manager to calculate the value
for this parameter for APEX 20KE devices. If omitted,
the default is one.
CLOCK0_SETTINGS String No Specifies the clock setting assignment to be used with
the clock0 port. If this parameter is specified, the
CLOCK0_BOOST, CLOCK0_DIVIDE, and
OUTCLOCK_PHASE_SHIFT parameters are not
required and are ignored. If both CLOCK0_SETTINGS
and CLOCK1_SETTINGS are specified, both must
have the same phase shift. If omitted, the default is
"UNUSED".
CLOCK1_BOOST Integer No Specifies the integer multiplication factor, which must
be greater than zero, for the clock1 port with respect
to the input clock frequency. This parameter can only
be specified if the clock1 port is used; however, it is
not required if a clock setting is specified for the
clock1 port. The setting for this parameter must be
one, two, or four for APEX 20K devices. Create the
PLL with the MegaWizard Plug-In Manager to
calculate the value for this parameter for APEX 20KE
devices. If omitted, the default is one.
CLOCK1_DIVIDE Integer No Specifies the integer division factor, which must be
greater than zero, for the clock1 port with respect to
the input clock frequency. The parameter can only be
specified if the clock1 port is used; however, it is not
required if a clock setting is specified for the clock1
port. If omitted, the default is one.
CLOCK1_SETTINGS String No Specifies the clock setting assignment to be used with
the clock1 port. If this parameter is specified, the
CLOCK1_BOOST, CLOCK1_DIVIDE, and
OUTCLOCK_PHASE_SHIFT parameters are not
required and are ignored. If both CLOCK0_SETTINGS
and CLOCK1_SETTINGS are specified, they both
must have the same phase shift. If omitted, the
default is "UNUSED".
Table 14. altclklock Parameter Descriptions (Part 5 of 6)
Name Type Required Description
Altera Corporation 29
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Function Prototype
The following sample code shows an AHDL function prototype (port
name and order also apply to Verilog HDL).
FUNCTION altclklock (inclock, inclocken, fbin)
WITH (INCLOCK_PERIOD, INCLOCK_SETTINGS,
VALID_LOCK_CYCLES, INVALID_LOCK_CYCLES,
VALID_LOCK_MULTIPLIER,
INVALID_LOCK_MULTIPLIER, OPERATION_MODE,
CLOCK0_BOOST, CLOCK0_DIVIDE, CLOCK0_SETTINGS,
CLOCK1_BOOST, CLOCK1_DIVIDE, CLOCK1_SETTINGS,
OUTCLOCK_PHASE_SHIFT)
RETURNS (clock0, clock1, locked);
OUTCLOCK_PHASE_SHIFT Integer No Specifies, in ps, the output clock phase shift relative
to the input clock. Phase shifts of 0.0 0.25, 0.5, or
0.75 times the input period (0˚, 90˚, or 270˚) are
implemented precisely. The allowable range for the
phase shift is between 0 ps and one input clock
period. If the phase shift is outside this range, the
Compiler adjusts it to fall within this range. For other
phase shifts, the Compiler chooses the closest
allowed value. If the fbin port is used, the
programmable phase shift is not available. This
parameter is not required if clock settings are used for
the clock0 and clock1 ports. If omitted, the default
is zero. ClockShift circuitry allows you to adjust the
clock delay or phase for precise timing. This
parameter is available only if the OPERATION_MODE
parameter is set to NORMAL. This parameter is
available only in APEX 20KE devices.
Table 14. altclklock Parameter Descriptions (Part 6 of 6)
Name Type Required Description
30 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
VHDL Component Declaration
The following sample code shows a VHDL component declaration for the
altclklock megafunction.
COMPONENT altclklock
GENERIC (INCLOCK_PERIOD: NATURAL;
INCLOCK_SETTINGS: STRING := "UNUSED";
VALID_LOCK_CYCLES: NATURAL := 3;
INVALID_LOCK_CYCLES: NATURAL := 3;
VALID_LOCK_MULTIPLIER: NATURAL := 1;
INVALID_LOCK_MULTIPLIER: NATURAL := 1;
OPERATION_MODE: STRING := "NORMAL";
CLOCK0_BOOST: NATURAL := 1;
CLOCK0_DIVIDE: NATURAL := 1;
CLOCK1_BOOST: NATURAL := 1;
CLOCK1_DIVIDE: NATURAL := 1;
CLOCK0_SETTINGS: STRING := "UNUSED";
CLOCK1_SETTINGS: STRING := "UNUSED";
OUTCLOCK_PHASE_SHIFT: NATURAL := 0);
PORT (inclock, inclocken: IN STD_LOGIC;
fbin : IN STD_LOGIC := '0';
clock0, clock1, locked : OUT STD_LOGIC);
END COMPONENT;
MegaWizard Interface
The MegaWizard Plug-In Manager automatically sets the appropriate
parameters. On the first page, the MegaWizard manager allows you to
select between entering a new instance or editing an existing instantiation.
On the second page of the MegaWizard Plug-In, choose altclklock
from the gates directory. On this same page, you can choose the filename
and an AHDL, VHDL, or Verilog HDL file type. The options on page three
of the MegaWizard window only apply to APEX 20KE device PLLs, as
shown in Figure 11. Table 15 lists the options available on page three of
the altclklock MegaWizard Plug-In Manager.
Altera Corporation 31
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 11. Page 3 of the altclklock MegaWizard Plug-In Manager
Table 15. altclklock MegaWizard Plug-In Options
Option Description
Use the feedback path
inside the PLL This option sets the OPERATION_MODE parameter to NORMAL. In this mode, the PLL
feedback path is internal to the PLL, minimizing the clock delay to the registers. This
mode allows for programmable phase shift. The phase shift can be entered as
degrees, ps, or ns using the drop-down list box. The smallest resolution that can be
implemented is between 500 ps and 1 ns, depending on the other PLL settings. The
clock0 or clock1 signals can be driven off-chip in this mode; however, they will not
be phase aligned with the clock input pin.
Use feedback through
the clock0/clock1 output
of the PLL
This option sets which PLL output, clock0 or clock1, will be driven off-chip in Zero
Delay Buffer or External Feedback mode.
Use on-chip connection
for the feedback (zero
delay buffer mode)
This option sets the OPERATION_MODE parameter to ZERO_DELAY_BUFFER. In this
mode, the clock port driven off-chip is phase aligned with the clock input pin for a
minimized clock input to external clock output pin delay. Phase shifting is not possible
in this mode. The clock output selected cannot be multiplied, but can be divided. The
remaining output port that is not driven off-chip can be multiplied.
Use off-chip connection
for the feedback (external
feedback mode)
This option sets the OPERATION_MODE parameter to EXTERNAL_FEEDBACK. In this
mode, the external feedback input pin is phase aligned with the clock input pin. The
external clock output pin must feed the external feedback input pin on the board. This
has the same restrictions as Zero Delay Buffer mode.
32 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Page four of the MegaWizard Plug-In Manager (see Figure 12) sets the
megafunction’s input frequency, clock multiplication, and clock division.
The Estimated Performance box displays the actual multiplication,
division, and phase shift. For circuits that can be constructed, the actual
multiplication and division factors may differ from the values you enter,
but the ratio of multiplication/division for a given clock output will be the
same. For circuits that cannot be constructed, the closest achievable
multiplication and division factors are displayed. The closest possible
phase shift for the estimated performance ratios is also given. The inability
to achieve the desired phase shift does not prevent circuit construction;
the compiler achieves the closest possible shift, shown under Actual
phase shift in the Estimated Performance box.
Figure 12. Page 4 of the altclklock MegaWizard Plug-In Manager
Page five of the MegaWizard Plug-In Manager (see Figure 13) provides
lock indication latency and clock enable port options. The lock indication
options are determined by the internal PLL configuration parameters that
are affected by the user-desired multiplication, division, and frequency.
These options automatically set the VALID_LOCK_CYCLES,
INVALID_LOCK_CYCLE, VALID_LOCK_MULTIPLIER, and
INVALID_LOCK_MULTIPLIER parameters.
Altera Corporation 33
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 13. Page 5 of the altclklock MegaWizard Plug-In Manager
Figures 14 and 15 are examples of PLL instantiations and configurations.
Figure 14. APEX 20K & APEX 20KE altclklock Instantiation with 2× & 4× Clocks
& Clock Inversion
PRN
CLRN
DQ
clock0
clock1
locked
inclock PLL
Input Frequency = 33.0 MHz
Clock0 Frequency = 2
Clock1 Frequency = 4
PRN
CLRN
DQ
data_a
data_b
66 MHz
133 MHz
clock_33
34 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 15. APEX 20KE altclklock Instantiation with Clock Multiplication, Phase
Shift & External Clock Output
Reporting
The ClockLock section of the compilation report displays information
regarding device PLL usage (i.e., altclklock megafunction usage). A
compilation information message displays whether the requested
clock_boost and clock_divide factors and/or the requested phase
shift can be achieved. This information is useful if you do not use the
MegaWizard Plug-In Manager to verify if a PLL configuration can be
constructed. For unachievable clock_boost and clock_divide
factors, compilation will provide an error message displaying the closest
achievable factors. For unachievable phase shift, the compilation displays
the closest-achievable and implemented phase shift. Actual valid or
invalid lock cycle indication is also displayed.
1The ClockLock section is omitted from the compilation report if
the design does not include PLLs. For more information on the
ClockLock section, see Quartus II software Help.
PRN
CLRN
DQ
clock0
clock1
locked
inclock PLL 3
Input Frequency = 33.33 MHz
Phase Shift = 90 degrees
Clock0 Frequency Ratio = 6
Clock1 Frequency Ratio = 3
clock1
locked
inclock PLL 4
Input Frequency = 33.33 MHz
Clock1 Frequency Ratio = 3
PRN
CLRN
DQ
data_a
data_b
clk_200
clk_100
clock_33
clock_100
Altera Corporation 35
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Timing Analysis
Multi-clock timing analysis causes the timing analyzer to report results
using slack. The PLL input clocks and output clocks are different clocks
that require multi-clock analysis. This condition is true even for the 1×
case, because the clock coming out of the PLL is generated from the PLL
VCO (not the clock pin), and has a reduced clock delay on the PLL output
clock.
Another important fact is that the PLL is tuned to run at the frequency you
specify. It will not function reliably when above or below the specified
frequency (except for a 2.5% frequency tolerance). The PLL runs according
to your specified settings and may not run at the maximum clock
frequency (fMAX). Because of this and the multi-clock analysis, fMAX is not
reported.
If an fMAX calculation is necessary, you can derive it from the reported
slack. The micro tCO, tSU, and path delay are given for a list path
command in the Slack Report window. These delays can be added and
inverted to find the fMAX of that path.
When using an external feedback input, the External Input Delay option
can be used to specify the amount of board delay from the external clock
output pin back to the external feedback input. This pin assignment can
be made in the Quartus II software through the Timing dialog box
(Tools menu – > Assignment Organizer).
Clock Domain Transfers
For data transfer across clock domains, specific design considerations
should be made when using PLL clocks with synchronous and
asynchronous transfers. The next two sections describe these
considerations.
Synchronous Transfers
If the two clocks for domain transfer come from a single PLL, all
synchronous register-to-register transfers (i.e. 50 MHz to 50 MHz or
50 MHz to 100 MHz) work across all conditions and no special design
considerations need to be made.
If the two clocks come from two different PLLs (i.e., fed by the same clock
with no ClockShift), you must insert at least one LE in the data path to
guarantee data transfer between two registers that are connected via local
interconnect. All other register-to-register transfers (e.g., across
MegaLAB™ interconnects) work without special design considerations.
Figure 16 shows the LCELL insertion for multiple clock source register-to-
register transfer via local interconnect.
36 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 16. LCELL Insertion for Multiple PLL Clock Source Register-to-Register
Transfer via Local Interconnect
Asynchronous Transfers
For asynchronous register-to-register transfer (i.e., 50 MHz to 33 MHz),
use the appropriate asynchronous design techniques to transfer data from
one clock domain to the other. For example, the DCFIFO first-in first-out
(FIFO) function can be used to buffer the data transfer. Figure 17 shows a
DCFIFO function that can be used to buffer the data transfer.
PRN
CLRN
DQ
PRN
CLRN
DQ
PLL1.clock0
PLL3.clock0
Registers Connected Via
Local Interconnect
Altera Corporation 37
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 17. Using DCFIFO to Interface between Asynchronous Clock Domains
If ClockShift feature is used only on some clocks in a register-to-register
transfer, the fMAX may be reduced or a hold time violation may occur,
depending on the direction, magnitude of the shift (any positive shift past
180 degrees can be considered negative shift), and whether the destination
or source register’s clock is shifted.
Simulation
The altclklock behavioral model can be used to simulate both the
APEX 20K PLL and the APEX 20KE PLL by generating a clock signal
based upon a reference clock. The APEX 20K and APEX 20KE behavioral
model’s instantiation should follow the same guidelines and restrictions
as the design entry. The altclklock behavioral and timing models do
not simulate jitter or lock acquisition time. At zero time, the simulation
assumes lock time has already occurred. The latency on lock indication is
modeled.
To simulate the External Feedback Input pin, you must set the External
Input Delay option on the external feedback input pin, as shown in the
steps below.
1. In the Quartus II software, choose Assignment Organizer (Tools
menu).
2. Choose the By Node tab. In the Mode box, select Edit Specific
Entity & Node Settings for:.
3. Select Browse (...). Use the Node finder to search for the external
feedback input pin and select OK.
rdreq
wrreq wrreq
33_MHz_data
50_MHz_data
50_MHz
33_MHz
RDCLK
RDREQ (ACK)
WRCLK
DATA
Q
DCFIFO
WRREQ
PLL used
for ClockBoost
Circuitry
38 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
4. In the Assignment Organizer, select the Timing assignment
categories list. In the Name list, select External Input Delay. In the
Setting box, type the amount of board fly time between the external
clock output pin and external feedback input pin. The delay should
not exceed 5 ns or 50% of the input clock period, whichever is less.
select OK.
The simulator can now model the external clock output timing with
external feedback.
The behavioral models for the altclklock megafunction reside in the
\quartus\eda\sim_lib directory. The apex20ke_mf.vhd file contains the
VHDL behavioral models and can be used for altclklock in both
APEX 20K and APEX 20KE devices. The apex20ke_mf.v file contains the
Verilog HDL behavioral models and can be used for altclklock in both
APEX 20K and APEX 20KE devices.
The behavioral model does not perform parameter error checking, and the
user must specify only valid values for the altclklock parameters.
When targeting APEX 20K devices, only use APEX 20K-applicable
parameters with appropriate values.
To simulate the model successfully, the VHDL simulator’s resolution
must be set to ps. A larger resolution will result in calculation rounding
and thus create incorrect multiplication or division.
Altera Corporation 39
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Sample VHDL Instantiation of the altclklock Model in a Design
The following shows a sample VHDL instantiation of the altclklock
model in a design.
library ieee;
use ieee.std_logic_1164.all;
entity pll_design is
port ( inclock : in std_logic;
inclocken : in std_logic;
data_in1 : in std_logic_vector(7 downto
0);
clock0 : out std_logic;
r_out : out std_logic_vector(7 downto
0);
locked : out std_logic);
end pll_design;
architecture apex of pll_design is
component my_dff
port ( clock : in STD_LOGIC;
data : in STD_LOGIC_VECTOR(7 DOWNTO
0);
q : out STD_LOGIC_VECTOR(7 DOWNTO
0));
end component;
component altclklock
generic (
inclock_period : natural;
inclock_settings : string :=
"UNUSED";
valid_lock_cycles : natural := 5;
invalid_lock_cycles : natural := 5;
valid_lock_multiplier : natural := 5;
invalid_lock_multiplier : natural := 5;
operation_mode : string :=
"NORMAL";
clock0_boost : natural := 1;
clock0_divide : natural := 1;
clock1_boost : natural := 1;
clock1_divide : natural := 1;
clock0_settings : string :=
"UNUSED";
clock1_settings : string :=
"UNUSED";
40 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
outclock_phase_shift : natural := 0 );
port ( inclock : in std_logic;
inclocken : in std_logic;
fbin : in std_logic := '0';
clock0 : out std_logic;
clock1 : out std_logic;
locked : out std_logic);
end component;
signal clock1_sig : std_logic;
begin
U0: altclklock
generic map
(
inclock_period => 40000,
clock1_boost => 4,
clock1_divide => 1,
clock0_boost => 2,
clock0_divide => 1,
operation_mode => "NORMAL",
valid_lock_cycles => 5,
invalid_lock_cycles => 5,
valid_lock_multiplier => 5,
invalid_lock_multiplier => 5,
outclock_phase_shift => 10000
)
port map
(inclock => inclock,
inclocken => inclocken,
clock0 => clock0,
clock1 => clock1_sig,
locked => locked);
process(clock1_sig)
begin
if clock1_sig'event and clock1_sig = '1'
then
r_out <= data_in1;
end if;
end process;
end apex;
Altera Corporation 41
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Sample Testbench for the VHDL Design
The following shows a sample testbench for the VHDL design.
library ieee;
use ieee.std_logic_1164.all;
entity plltest2 is
end plltest2;
architecture behave2 of plltest2 is
signal inclock : std_logic := '0';
signal inclocken : std_logic;
signal data_in1 : std_logic_vector(7 downto 0)
:= "10101010";
signal clock0 : std_logic;
signal locked : std_logic;
signal r_out : std_logic_vector(7 downto 0);
component pll_design
port (
inclock : in std_logic;
inclocken : in std_logic;
data_in1 : std_logic_vector(7 downto 0);
clock0 : out std_logic;
r_out : out std_logic_vector(7 downto 0);
locked : out std_logic) ;
end component;
begin
inclocken <= '1' after 5 ns;
U0 : pll_design port map (
inclock => inclock,
inclocken => inclocken,
data_in1 => data_in1,
clock0 => clock0,
r_out => r_out,
locked => locked);
process(inclock)
begin
for i in 1 to 100 loop
inclock <= not inclock after 20 ns;
end loop;
end process;
42 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
end behave2;
configuration pllconfig of plltest2 is
for behave2
for U0: pll_design use entity
work.pll_design(apex);
end for;
end for;
end pllconfig;
Example Verilog HDL Instantiation of the altclklock Model in a
Design
The following shows an example Verilog HDL instantiation of the
alkclklock model in a design.
module pllsource (inclock, inclocken, data_in1,
clock0, r_out, locked);
input inclock, inclocken;
input [7:0] data_in1;
output clock0, locked;
output [7:0] r_out;
wire clock1_sig;
reg [7:0] r_out;
altclklock PLL_1
( .inclock(inclock), .inclocken(inclocken),
.clock0(clock0),
.clock1(clock1_sig), .locked(locked));
defparam
PLL_1.inclock_period = 50000,
PLL_1.inclock_settings = "UNUSED",
PLL_1.clock0_settings = "UNUSED",
PLL_1.clock1_settings = "UNUSED",
PLL_1.valid_lock_cycles = 5,
PLL_1.invalid_lock_cycles = 5,
PLL_1.valid_lock_multiplier = 5,
PLL_1.invalid_lock_multiplier = 5,
PLL_1.clock0_boost = 4,
PLL_1.clock1_boost = 2,
PLL_1.clock0_divide = 1,
PLL_1.clock1_divide = 1,
PLL_1.outclock_phase_shift = 0,
PLL_1.operation_mode = "NORMAL";
Altera Corporation 43
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
always @(posedge clock1_sig)
begin
r_out = data_in1;
end
44 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Sample Testbench for Verilog HDL Design
The following shows a sample testbench for a Verilog HDL design.
timescale 1 ns/100ps
module plltest;
parameter tmp = 8'b 10101010;
reg inclock, inclocken;
reg [7:0] data_in1;
wire clock0, locked;
wire [7:0] r_out;
pllsource U1
( .inclock(inclock), .inclocken(inclocken),
.data_in1(data_in1),
.clock0(clock0), .r_out(r_out),
.locked(locked));
initial
data_in1 = tmp;
initial
inclock = 0;
always #25 inclock = ~inclock;
initial
begin
#0 inclocken = 0;
#5 inclocken = 1;
end
initial
begin
#100 data_in1 = 8'b 11110000;
#200 data_in1 = 8'b 00110011;
end
endmodule
Altera Corporation 45
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Sample Waveform
Figure 18 shows an example waveform for dual-clock outputs of the
APEX 20KE PLL. In this example, clock0 is a 2× clock and clock1 is a 4×
clock; both are shifted/lag by 90˚. For simulation,
|altclklock|<instance>|pll is the clock0 output of the PLL,
|altclklock|<instance>|pll~CLK1 is the clock1 output of the PLL,
and |altclklock|<instance>|pll~LOCKED is the locked output
indication. In timing simulation, output clocks have a slight negative shift
because they are at the output of the PLL and not at the flip-flop clock
ports. A positive delay is added as they reach the clock ports of RAMs or
flip-flops.
Figure 18. Timing Simulation Output Waveform for Dual-Output Clocks with 90˚ Shift
Applications This section describes some applications of the APEX 20KE device’s
ClockLock, ClockBoost, and ClockShift features.
Clock Multiplication & Division
The ClockBoost feature allows designers to use low-speed clocks on the
board, reducing the effects of high-speed clocks; designers can use a low-
speed clock on the board and then use the ClockBoost feature to increase
clock speed within the device.
Using a lower speed clock can help reduce transmission line effects and
allow the designer to simplify board layout. In APEX 20K devices, the
board clock can be multiplied by 2 or 4 within the device. More complex
ratios are possible with APEX 20KE devices. See Tables 12 and 13 on
page 23 for more information.
46 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Clock multiplication and division are useful for communications
applications. The ClockBoost feature can be used when transfer rates must
be multiplied or divided. The multiplication and division of clocks is also
needed to maintain bit rates when converting between parallel data
streams and serial data streams.
In microprocessor-based systems, a system clock may run at a lower rate
than other system components. For example, an embedded processor or
its peripheral circuits may run at a faster rate than the system I/O bus
clock. Embedded applications also require faster internal rates for
operations such as synchronization and counting. The ClockBoost feature
can be used to multiply a slower system bus clock for an embedded
application in an APEX 20K device. The multiplication and division
capabilities of an APEX 20K device give designers the ability to develop
SOPC
designs. Figure 19 shows clock synthesis in an embedded application.
Figure 19. Embedded Application Using Clock Synthesis
The ClockBoost feature can be used to create variable-size pulse widths.
By using a multiplied frequency and a counter, you can create pulse
widths of various sizes depending on the multiplied frequency driving
the counter. These pulses can be used to interface with external SRAM or
DRAM. For example, write enable (WE), row address strobe (RAS), and
column address strobe (CAS) signals can be generated for a DRAM
interface, meeting appropriate address and data setup times. See
Figure 20.
Microprocessor
System
Clock 8 MHz Logic
Logic
Logic
Logic
PLL
2×
PLL
4×
PLL
8×
PLL
16×
16 MHz
32 MHz
64 MHz
128 MHz
Altera Corporation 47
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 20. Using Multiplication to Generate Pulses
Removing Board Delay
APEX 20KE device feedback pins allow the designer to reduce the clock
skew between several devices on a board. The PLL actively aligns the
feedback input to the CLK input clock. The PLL dynamically adjusts the
output during operation to account for delay changes that occur due to
temperature or voltage. While designing the board, you should match the
return delay containing the feedback input with the delay to each device
involved. Similar delays ensure that the aligned feedback input edge is
also aligned at the destination devices, eliminating delay. Figure 21
illustrates how board delay is reduced using an APEX 20KE device.
CLK
CLK × 2
ADDR
DATA
WE
A0 A1 A2
D1
CLK
CLK × 4
Pulse
48 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 21. Reducing Board Delay Using an APEX 20KE Device Note (1)
Note:
(1) For board design, the route delay from CLKLK_OUT1 to each device and the return
route delay to CLKLK_FB1 should be equal.
1Minimize the delays between the CLKLK_OUT and CLKLK_FB
signals in APEX 20KE devices. Be sure the PLL clock-to-output
time plus board fly time is less than 5 ns or 50% of the input clock
period, whichever is less.
LVDS
In EP20K400E and larger devices, two of the general-purpose PLLs can be
configured for use in LVDS interfaces. These PLLs interface with the
APEX 20KE LVDS differential input and output blocks. You can multiply
the clock input by 4, 7, or 8 for LVDS/CMOS data conversion using
dedicated, built-in parallel-to-serial and serial-to-parallel converters.
When the APEX 20KE device is configured to use LVDS, it uses PLL 3 to
multiply the LVDSRXINCLK1p input. Serial-to-parallel conversion
circuitry uses the multiplied clock to convert the high-speed serial LVDS
data to low-speed parallel CMOS data. The multiplication factor used
should match the multiplexer/de-multiplexer ratio desired. For example,
if a conversion of 1-to-8 is required for a 622-Mbps LVDS channel, the
multiplication factor needed is 8 with a clock input of 77.75 MHz. If
needed, the serial-to-parallel converter and PLL can be bypassed for low-
speed LVDS data inputs. Figure 22 shows the built-in LVDS input
interface with the LVDS serial input at 622 Mbps and the
multiplexer/de-multiplexer ratio at 1-to-8.
APEX 20KE Device
CLK
CLKLK_FB
CLKLK_OUT
Device
Device
Device
Altera Corporation 49
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 22. APEX 20KE LVDS Receiver Interface
When the APEX 20KE device is configured to use LVDS, it uses PLL 4 to
multiply the LVDSTXINCCLK1p input. Parallel-to-serial conversion
circuitry uses the multiplied clock to convert the low-speed parallel
CMOS data to high-speed serial LVDS output data. The multiplication
factor should match the multiplexer/de-multiplexer ratio desired. For
example, if a conversion of 7-to-1 is needed for a 462-Mbps LVDS output,
the multiplication factor needed is seven with an input clock of 66 MHz.
If needed, the parallel-to-serial converter and PLL can be bypassed for a
low-speed LVDS serial output. Figure 23 shows the built-in LVDS output
interface that converts internal parallel data into LVDS serial data with a
7-to-1 ratio at 462 Mbps.
Figure 23. APEX 20KE Transmitter Interface
Note:
(1) In LVDS mode, PLL 4 is fed by LVDSTXINCLK1p or one of the three remaining internal global clocks (G1, G2, G3).
These remaining global clocks cannot be used if fed by a general-purpose PLL (receiver PLL is allowed).
I/O
Serial-to-Parallel
Converter
data[7..0]
Dedicated Clock
622 MHz (8×)
77.75 MHz (1×)
Serial Data 622 Mbps
LVDSRXINCLK1P
77.75 MHz Clock
PLL 3
APEX 20KE LVDS
+
+
Built-in I/O
Parallel-to-Serial
Converter
data[6..0]
66 MHz (1×)
66-MHz LVDSTXINCLK1p 462 MHz (7×)
PLL 4
Internal Global
Clocks (1)
Serial Data 462 Mbps
APEX 20KE LVDS Interface
+
+
LVDSTXOUTCLK1
+
50 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
T1 & E1 Clock Domain Conversion
In APEX 20KE devices, the ClockBoost circuitry can be used to convert a
T1 clock frequency (1.544 MHz) to an E1 clock frequency (2.048 MHz) and
vice versa. The ClockLock circuit has a special mode to perform T1/E1
conversions; this multiplication is accomplished by setting the
CLOCK0_BOOST, CLOCK1_BOOST, CLOCK0_DIVIDE, and
CLOCK1_DIVIDE parameters to 256/193 or 193/256.
As with any type of clock domain data transfer, use the appropriate
asynchronous design techniques to transfer data from one clock domain
to the other. For example, the DCFIFO FIFO function can be used to buffer
the data transfer. Figure 24 shows a DCFIFO that interfaces between clock
domains. For example, a DCFIFO is fed with input data clocked by the PLL
input T1 clock. The output of the DCFIFO should be clocked with the
converted E1 clock from the PLL output. Output data is synchronized to
the PLL output E1 clock. This same practice is used for synchronization
across other clock domains.
Figure 24. Using DCFIFO to Interface between Clock Domains
Time-Domain Multiplexing
The ClockBoost feature allows designers to implement time-domain
multiplexed applications in which a given circuit is used more than once
per clock cycle. Depending on whether the circuit is clocked by the 2× or
4× ClockBoost circuitry in the APEX 20K device, it can operate two or four
times, respectively, per system cycle. With time-domain multiplexing, a
given function can be implemented with fewer LEs or ESBs.
rdreq
wrreq wrreq
33_MHz_data
50_MHz_data
50_MHz
33_MHz
RDCLK
RDREQ (ACK)
WRCLK
DATA
Q
DCFIFO
WRREQ
PLL used
for ClockBoost
Circuitry
Altera Corporation 51
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
For example, in a circuit using two 16 × 16 multipliers, each multiplier
uses 447 LEs for a total of 894 LEs. Alternatively, you could implement the
circuit as one multiplier that is used twice per clock cycle by using a clock
that is 2× the system clock. The input of the multiplier is multiplexed so it
can switch between two sets of inputs; the output is de-multiplexed so
that it can drive out the two multiplication results. While some LEs are
needed to accomplish the multiplexing, the cost is outweighed by the LEs
saved by using one multiplier. Figure 25 shows a schematic of the time-
domain multiplexed circuit.
Figure 25. Time-Domain Multiplexed Circuit
D
dataa1[15..0]
D
datab1[15..0]
D
D
D
dataa2[15..0]
D
datab2[15..0]
ENA
ENA
16 × 16
Multiplier
productb[31..0]
producta[31..0]
control signal
ClockLock
ClockBoost × 2
clk
52 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
The same example can be applied to a circuit requiring four multipliers;
the circuit would use a 4× clock and 4-to-1 multiplexers instead of the
2-to-1 multiplexers shown in Figure 25. A control line bus can be created
using a one-hot counter or state machine to enable one output bus register
per 4× clock cycle, permitting one multiplier to be used four times in a
single system clock cycle. Table 16 shows the reduction in resource
requirements.
ClockShift Applications
Phase and time delay adjustment of PLL clock outputs have many
interface applications. Delay adjustment allows the designer to overcome
strict timing margins that would not be possible to overcome without
clock adjustment. By adjusting the clock output’s lead or lag, you can use
a known clock delay between various clocks to improve the perceived
clock-to-output timing for the PLD or external devices.
Some high-speed devices, such as SDRAMs, have access times that
require fast setup times on the interface device for a given critical path. To
meet device-to-device timing requirements, the internal clock to the
destination chip’s input register can be adjusted to lag a specified amount
of time from the input clock. By adding clock lag, you can obtain a faster
setup time on the destination device input register. Figure 26 shows an
APEX 20KE and ASIC device-to-device interface with timing. For
example, the APEX 20KE device may be receiving data from an ASIC with
a 5.5 ns tCO. Assuming a 133-MHz system speed and a board propagation
delay of 1 ns (tPD) between the ASIC and APEX 20KE device, the
tCO + tDELAY = 6.5 ns. Only 1.0 ns is left for setup time into the APEX 20KE
device (7.5 ns period). Timing can be met by adjusting the APEX 20KE
internal clock to lag by an amount of tSU (PLD) – tSU (needed).
Table 16. Resources Required for 16 × 16 Multipliers
Design LEs Required
Two 16 × 16 multipliers 894
Two 16 × 16 multipliers, time-domain multiplexed with 2×
ClockBoost 547
Four 16 × 16 multipliers 1,788
Four 16 × 16 multipliers, time-domain multiplexed with 4×
ClockBoost 741
Altera Corporation 53
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Figure 26. APEX 20KE and ASIC Device-to-Device Interface with Timing
In cases where feedback is not used, clock delay control can be used to
adjust clock delay to other devices based on their distance from the clock
source. Designers can manually adjust the external clock output of the
APEX 20KE device to compensate for board delay.
Phase adjustment is also useful for interfaces to an external device. An
input clock can be phase shifted with two separate altclklock circuits
and then output to the two external outputs. This along with the input
could be used for a three-phase DC motor control.
Conclusion The advanced APEX 20K ClockLock and ClockBoost features use PLLs to
provide significant improvements in system performance and design
versatility. The reduction in clock delay and the elimination of clock skew
within the device improves design speed, and time-domain multiplexing
improves area usage. The ClockBoost feature simplifies board design by
running the internal logic of the device at a faster rate than the input clock
frequency. The advanced APEX 20KE ClockLock and ClockBoost feature
set is further enhanced with m/(n × k) multiplication, LVDS I/O
interfaces, and phase adjustment for more complex clock synthesis
applications.
ASIC APEX 20KE
tSU tPD tSU
PLL
CLKIN
PLL with Shift
t = 7.5 ns
CLK
t + t = 6.5 ns
CO PD
t (Needed) = 1 ns
SU
t (APEX)
SU
54 Altera Corporation
AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices
Revision
History
The information contained in Application Note 115 (Using the ClockLock &
ClockBoost PLL Features in APEX Devices) version 2.1 supersedes
information published in previous versions.
Version 2.1 Changes
Updated Tables 3, 4, 6, and 11
Added Tables 7, 8
Updated Figures 7 and 23
Updated APEX 20KE Devices section
Version 2.01 Changes
Version 2.01 contains the following changes:
Updated information in Board Layout from pages 16 to 19
Added Figures 9, 26
Updated Table 11
AN 115: Using the ClockLock & ClockBoost Features in APEX Devices
Altera Corporation 55
Notes:
®
Altera, APEX, APEX 20K, APEX 20KE, ClockBoost, ClockLock, ClockShift, MegaWizard, Quartus,
Quartus II, and specific device designations are trademarks and/or service marks of Altera Corporation in the
United States and other countries. Altera acknowledges the trademarks of other organizations for their
respective products or services mentioned in this document. Altera products are protected under numerous
U.S. and foreign patents and pending applications, maskwork rights, and copyrights. Altera warrants
performance of its semiconductor products to current specifications in accordance with Altera’s standard
warranty, but reserves the right to make changes to any products and services at any time without notice.
Altera assumes no responsibility or liability arising out of the application or use of any
information, product, or service described herein except as expressly agreed to in writing by
Altera Corporation. Altera customers are advised to obtain the latest version of device
specifications before relying on any published information and before placing orders for
products or services.
Copyright 2001 Altera Corporation. All rights reserved.
101 Innovation Drive
San Jose, CA 95134
(408) 544-7000
http://www.altera.com
Applications Hotline:
(800) 800-EPLD
Customer Marketing:
(408) 544-7104
Literature Services:
(888) 3-ALTERA
lit_req@altera.com
AN 115: Using the ClockLock & ClockBoost Features in APEX Devices
56 Altera Corporation
Printed on Recycled Paper.