Section E H-MOSS(R) Controls Index Product Page Hubbell Sensors Technology Technologies for Smart Buildings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-2 Energy Savings and Code Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3 Wall Switches Adaptive Technology, Occupancy and Vacancy . . . . . . . . . . . . . . . . . . . . . . E-5 Passive Infrared, Occupancy and Vacancy and Digital Timers . . . . . . . . . . E-6 Ceiling, Wall and End Mount Sensors Low Voltage and Line Voltage Ceiling Sensors . . . . . . . . . . . . . . . . . . . . . . . E-7 Wall Mount Sensors and OPTIMYZER(R) High Bay, Low Bay . . . . . . . . . . . . E-8 Daylight Harvesting and Control Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-9 MAXXTM Harsh Environment Occupancy Sensors Watertight Wall Mount PIR Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-11 Extreme Temperature PIR Ceiling Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . E-11 OPTIMYZER(R) Watertight End Mount PIR Sensor. . . . . . . . . . . . . . . . . . . . E-11 Plug Load Control Products System Overview/Methods for Complaince . . . . . . . . . . . . . . . . . . . . . . . . E-12 Pre-Marked Receptacles and Control Units . . . . . . . . . . . . . . . . . . . . . . . . E-13 WL-Series Wireless Sensors and Controls Wall Switches, Ceiling and Wall Mount Sensors . . . . . . . . . . . . . . . . . . . . . E-15 Specifications, Coverage Patterns and Wiring Schematics Wall Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-16 Ceiling and Wall Mount Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-18 Control Units and Add-A-Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-19 OPTIMYZER(R) High Bay Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-22 MAXXTM Harsh Environment Occupancy Sensors . . . . . . . . . . . . . . . . . . . E-22 MAXXTM OPTIMYZER(R) Watertight Sensors . . . . . . . . . . . . . . . . . . . . . . . . E-23 Plug Load Control, Wired and Wireless . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-25 WL-Series Wireless Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-26 Switches, Ceiling and Wall Mount Sensors H-MOSS|MAXX(R) Sensors WL-Series Wireless Sensors and Controls High Bay and Daylight Harvesting www.hubbell-wiring.com (R) Wiring Device-Kellems E-1 H-MOSS(R) Controls Technologies for Smart Buildings H-MOSS(R) Occupancy Sensors Combine Innovative Technologies for Industry Proven Performance. Adaptive Technology Adaptive Technology is a Hubbell breakthrough that delivers benefits to both building owners and occupants. The building owner achieves reduced energy costs, fewer adjustments and less maintenance, and the building occupant experiences fewer false-offs and disturbances. Adaptive technology occupancy sensors use microprocessors that make all the decisions for setting adjustments. Internal software constantly monitors the controlled area and automatically adjusts the sensitivity and timer based on environmental history. This means that instead of manually adjusting the sensor for seasonal changes, modified airflow, furniture layout or occupancy pattern changes, the sensor automatically adjusts itself. These automatic adjustments eliminate the need for multiple manual adjustments by maintenance personnel or outside contractors. Hubbell offers adaptive technology throughout its product offering--wall switches, ceiling and wall mount sensors--in conjunction with dual technology, ultrasonic and passive infrared products. How to Select the Right Technology for the Proper Application Dual Technology Dual technology occupancy sensors combine both passive infrared (PIR) and ultrasonic (US) technologies for maximum reliability. Because US and PIR need to both detect occupancy to turn lighting ON, dual technology sensors minimize the risk of lights coming ON when the space is unoccupied--false triggering. Continued detection by only one technology then keeps lighting ON as necessary. Dual technology sensors offer the best performance for most applications. E-2 Ultrasonic (US) Ultrasonic (US) technology senses occupancy by bouncing sound waves (32 kHz - 45 kHz) off of objects and detecting a frequency shift between the emitted and reflected sound waves. Movement by a person or object within a space causes a shift in frequency, which the sensor interprets as occupancy. While US occupancy sensors have a limited range, they are excellent at detecting even minor motion such as typing and filing, and they do not require an unobstructed line-of-sight. This makes US technology sensors ideal for an application like an office with cubicles or a restroom with stalls. (R) Wiring Device-Kellems Passive Infrared (PIR) Passive infrared (PIR) technology senses occupancy by detecting the movement of heat emitted from the human body against the background space. Unlike US technology, PIR sensors require an unobstructed line-of-sight for detection. These sensors use a segmented lens, which divides the coverage area into zones. Movement between zones is then interpreted as occupancy. PIR sensors are ideal for detecting major motion (e.g. walking), and they work best in small, enclosed spaces with high levels of occupant movement. www.hubbell-wiring.com H-MOSS(R) Controls Energy Savings and Code Compliance Typical Applications Application Office Small Large Open Office Wall Switch Ceiling Sensor Wall Sensor Applications are generalized. Consult your Hubbell representative for the type of technology and products that fit your needs. Storage/ Warehouse Rest Room Conference Room Classroom Sensor Technology Adaptive Dual + + + + + Ultrasonic + + + Small Large Small Large Small Large Hall + + + + + + Ceiling + + + + + + + + + + + + + + + Hubbell Occupancy Sensors Play a Key Role + + + + + Wall + Electrical bill impact for a typical office building* In the U.S., lighting consumes 22% of electricity and represents $40 billion a year in energy costs. Using advanced technology, Hubbell's H-MOSS(R) Occupancy Sensors are doing their part to save energy and provide sustainability by automatically and effectively turning lights on when a room is occupied and off when a room is vacant. In a typical office building, where lighting accounts for 35 to 45% of energy use, H-MOSS Occupancy Sensors have the potential to reduce wasted lighting by 13% to 90% for a significant return on investment (ROI). Lighting Uses 39% of Total Electricity Lighting Other 39% Savings 16% 14% Potential electricity bill savings** Refrigeration Code Compliance Hubbell offers a broad range of occupancy and vacancy sensors and lighting controls that meet the latest codes and standards, including ASHRAE/IESNA 90.1 and California Energy Commission (CEC) Title 24. H-MOSS Occupancy Sensors can also provide LEED(R) points in categories like Sustainable Sites, Energy and Atmosphere, Indoor Environmental Quality and Innovative Design Process. Wall Switch + Small Large Sensor Style PIR 5% Office Equipment 15% Climate Control 27% Note: *Energy Information Administration: - Commercial Buildings - Energy Consumption Survey **Based on 40% lighting savings from sensors. Actual results may vary. Backed by Hubbell Service and Support H-MOSS(R) Occupancy Sensors are backed by Hubbell HSI = GREEN SM Sustainability Initiative and superior service and support including: * Valuable online H-MOSS ROI worksheet for calculating energy savings * Detailed H-MOSS online e-learning courses that can be taken anywhere, anytime * Product selection guide for choosing the right H-MOSS Occupancy Sensor and technology * Online specification assistance through spec wizard, AutoCAD drawings, templates, BIM objects and documentation * Comprehensive design assistance for deploying occupancy sensors in a variety of applications * Highly knowledgeable network of specification professionals and trained, dedicated sales staff * Backed by Hubbell who is committed to safeguarding the environment through environmental stewardship, innovative products and efficient operations www.hubbell-wiring.com (R) Wiring Device-Kellems E-3 H-MOSS(R) Controls Adaptive Technology Wall Switches Features and Benefits Dual (Ultrasonic and Passive Infrared) Steel mounting strap Impact resistant hard lens is standard and color matched to the switch Built-in photocell with manual super saver mode for daylight harvesting Dual technology sensing combines the individual advantages of passive infrared and ultrasonic detection Auto or manual ON operating modes; available in either single relay or dual relay versions for enhanced savings with bi-level switching applications Designed for use on 120V AC or 277V AC circuits; no neutral needed for fast retrofits Adaptive technology - "Install and forget" operation, analyzes environment and adjusts sensitivity and timer, eliminating the need for manual adjustment AD2000W1 Passive Infrared Steel mounting strap Heavy duty relay controls up to 1000 watts at 120V AC or 1800 watts at 277V AC High density 1200 square foot 180 coverage with tough tamper resistant lens Photocell can prevent lights from turning ON with sufficient natural light Nightlight version available to provide minimum illumination when the lights are OFF Front press switch allows the occupant to switch the sensor from automatic operation to momentary OFF mode Tamper-resistant push button covers the time-out, service switch, vacancy and occupancy operation mode settings Designed for use on 120V AC or 277V AC circuits; no neutral needed for fast retrofits ATP2000W E-4 (R) Wiring Device-Kellems www.hubbell-wiring.com H-MOSS(R) Controls Wall Switches Featuring Adaptive Technology Adaptive Technology * * * * * * * "Install and forget" operation Zero arc point switching Dual 120/277V AC operation; no neutral required Auto or manual ON operating modes (2000 series) Manual ON (Vacancy) operating mode (2001 series) No minimum load requirements Hard lens (dual technology, passive infrared) * Steel mounting strap * Built-in photocell with manual super saver mode for daylight harvesting * Bi-level switching or dual load control (2 or 2N suffix) * Compatible with most LED and CFL * CEC Title 24 Compliant * cULus AD2000W1 AD2001W1 Dual (Ultrasonic and Passive Infrared) 1000 square foot coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC, 1800W Fluorescent at 277V AC, 50/60Hz. Description Color Single Circuit 1 button for Auto control manual/auto control with no button Dual (ultrasonic and passive infrared) Black Gray Ivory Light Almond White Black Gray Ivory Light Almond White AD2000BK1 AD2000GY1* AD2000I1* AD2000LA1* AD2000W1* AD2001BK1 AD2001GY1 AD2001I1 AD2001LA1 AD2001W1 Manual ON (Vacancy) AD2000BK1N AD2000GY1N AD2000I1N* AD2000LA1N AD2000W1N* -- -- -- -- -- Dual Circuit 2 buttons for Auto control manual/auto control with no button AD2000BK2 AD2000GY2 AD2000I2* AD2000LA2 AD2000W2* AD2001BK2 AD2001GY2 AD2001I2 AD2001LA2 AD2001W2 AD2000BK2N AD2000GY2N AD2000I2N AD2000LA2N AD2000W2N -- -- -- -- -- AD2000W1N AD2000W2N Note: *Neutral wire versions, use ADN prefix when ordering. Wallplate sold separately. See pages E-16 and E-17 for technical specifications, coverage patterns and wiring schematics. Ultrasonic 400 square foot coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC, 1800W Fluorescent at 277V AC, 50/60Hz. Description Color Single Circuit 1 button for Auto control manual/auto control with no button Ultrasonic Black Gray Ivory Light Almond White Black Gray Ivory Light Almond White AU2000BK1 AU2000GY1 AU2000I1* AU2000LA1 AU2000W1* AU2001BK1 AU2001GY1 AU2001I1 AU2001LA1 AU2001W1 Manual ON (Vacancy) AU2000BK1N AU2000GY1N AU2000I1N* AU2000LA1N AU2000W1N* -- -- -- -- -- Dual Circuit 2 buttons for Auto control manual/auto control with no button AU2000BK2 AU2000GY2 AU2000I2 AU2000LA2 AU2000W2 AU2001BK2 AU2001GY2 AU2001I2 AU2001LA2 AU2001W2 AU2000BK2N AU2000GY2N AU2000I2N AU2000LA2N AU2000W2N -- -- -- -- -- AU2000W1 AU2001W1 AU2000W2 AU2001W2 Note: *Neutral wire versions, use AUN prefix when ordering. Wallplate sold separately. See pages E-16 and E-17 for technical specifications, coverage patterns and wiring schematics. Passive Infrared 1000 square foot coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC, 1800W Fluorescent at 277V AC, 50/60Hz. Description Color Single Circuit 1 button for Auto control manual/auto control with no button Passive infrared Black Gray Ivory Light Almond White Black Gray Ivory Light Almond White AP2000BK1 AP2000GY1* AP2000I1* AP2000LA1* AP2000W1* AP2001BK1 AP2001GY1 AP2001I1 AP2001LA1 AP2001W1 Manual ON (Vacancy) AP2000BK1N AP2000GY1N AP2000I1N* AP2000LA1N AP2000W1N* -- -- -- -- -- Dual Circuit 2 buttons for Auto control manual/auto control with no button AP2000BK2 AP2000GY2 AP2000I2* AP2000LA2 AP2000W2* AP2001BK2 AP2001GY2 AP2001I2 AP2001LA2 AP2001W2 AP2000BK2N AP2000GY2N AP2000I2N AP2000LA2N AP2000W2N -- -- -- -- -- Note: *Neutral wire versions, use APN prefix when ordering. Wallplate sold separately. See pages E-16 and E-17 for technical specifications, coverage patterns and wiring schematics. www.hubbell-wiring.com (R) Wiring Device-Kellems AP2000W1 AP2001W1 AP2000W2 AP2001W2 E-5 H-MOSS(R) Controls Wall Switches and Digital Timers Featuring Passive Infrared Technology Adaptive Technology, Passive Infrared ATP2000W * "Install and forget" operation * Passive infrared technology * Dual 120/277V AC operation, no neutral required * 1200 sq. ft. coverage * Built-in photocell for daylight harvesting * * * * * Wallplate included Steel mounting strap Compatible with most LED and CFL CEC Title 24 Compliant cULus Description Color Standard with Nightlight with Neutral with Nightlight and Neutral Adaptive auto-adjusting; selectable manual/auto-ON operation; dual-voltage 120/277V AC; 3-way capable Gray Ivory Light Almond White ATP2000GY ATP2000I ATP2000LA ATP2000W ATP2000NGY ATP2000NI ATP2000NLA ATP2000NW -- ATP2004I -- ATP2004W -- ATP2004NI -- ATP2004NW Note: See page E-17 for technical specifications, coverage patterns and wiring schematics. Passive Infrared WS2000W WS1000W * * * * * Passive infrared technology Manual adjustment time delay (20 sec. to 30 min.) Photocell (WS2000 series) No neutral required 1200 sq. ft. coverage * * * * * Wallplate included Steel mounting strap Compatible with most LED and CFL CEC Title 24 Compliant cULus Description Color Standard with Nightlight with Neutral with Nightlight and Neutral Manual adjusting; selectable manual/auto-ON operation; dual-voltage 120/277V AC; 3-way capable Gray Ivory Light Almond White WS2000GY WS2000I WS2000LA WS2000W WS2000NGY WS2000NI WS2000NLA WS2000NW -- WS2004I -- WS2004W -- WS2004NI -- WS2004NW Manual adjusting; auto-ON operation; 120V AC only Ivory White WS1000I WS1000W WS1000NI WS1000NW -- -- -- -- Manual adjusting; Manual-ON operation; 120V AC only Ivory White WS1001I WS1001W WS1001NI WS1001NW -- -- -- -- Note: See page E-17 for technical specifications, coverage patterns and wiring schematics. DT2000W Digital Timer Description Color Catalog Number Dip switch enabled preset intervals, user adjustable up to 4 hours, 3-way capable, 960W @ 120V AC and 1200W @ 277V AC. Includes an ON/OFF momentary push button switch feature. White DT2000W Count Down Timers DT5030W Description Color 30 Minutes: OFF, 5, 10, 20, 30 60 Minutes: OFF, 15, 30, 45, 60 12 Hours: OFF, 2, 4, 8, 12 1000W @ 120V AC and 1400W @ 277V AC Ivory Light Almond White DT5030I DT5030LA DT5030W DT5060I DT5060LA DT5060W DT5012I DT5012LA DT5012W Low Voltage Switches * Attractive, architectural design * Available latching or momentary contact Description Color Catalog Number Low voltage switch, latching, 1 button Ivory White Ivory White Ivory White DSL30I1 DSL30W1 DSM30I1 DSM30W1 DSM30I2 DSM30W2 Low voltage switch, momentary, 1 button Low voltage switch, momentary, 2 button DSL30W1 DSM30W1 E-6 * Mounts to standard single gang box * 2-year warranty Note: Wallplate sold separately. (R) Wiring Device-Kellems www.hubbell-wiring.com H-MOSS(R) Controls Ceiling Sensors Featuring Adaptive Technology Adaptive Technology * "Install and forget" operation * All digital sensing technology * Photocell and relay to interface with auxiliary systems such as HVAC (CRP models) * Non-volatile memory settings retained after power outage * * * * * * * Mounting base included with sensor Low voltage units: 24V DC, 33mA Line voltage units: 20A, 120-277V AC 32kHz (ATD/ATU500C and CRP - 40kHz) Compatible with most LED and CFL CEC Title 24 Compliant cULus ATD2000 Dual (Ultrasonic and Passive Infrared) Combines the excellent minor motion detection of ultrasonic with the outstanding passive infrared (PIR) long-range major motion detection. Coverage Area Description Color 2000 sq. ft. (360) 1000 sq. ft. (180) 500 sq. ft. (180) Low voltage sensor with photocell and isolated relay Low voltage sensor Line voltage sensor Office White Office White Office White ATD2000CRP ATD1000CRP ATD500CRP ATD2000C ATD1000C ATD500C ATD2000CL ATD1000CL -- Note: Low voltage ATD ceiling sensors must use a CU series control unit. See page E-9 for details. See pages E-18 to E-21 for technical specifications, coverage patterns and wiring schematics. ATD1000C/ ATD500C Ultrasonic Excellent minor motion detection. Coverage Area Description Color 2000 sq. ft. (360) 1000 sq. ft. (180) 500 sq. ft. (180) Low voltage sensor with photocell and isolated relay Low voltage sensor Line voltage sensor Office White Office White Office White ATU2000CRP ATU1000CRP ATU500CRP ATU2000C ATU1000C ATU500C ATU2000CL ATU1000CL -- ATU2000C Note: Low voltage ATU ceiling sensors must use a CU series control unit. See page E-9 for details. See pages E-18 to E-21 for technical specifications, coverage patterns and wiring schematics. Passive Infrared Outstanding long range major motion detection. Coverage Area Description Color 1500 sq. ft. (360) 450 sq. ft. (360) Low voltage sensor with photocell and isolated relay Low voltage sensor Line voltage sensor Office White Office White Office White ATP1500CRP ATP1500C ATP1500CL ATP600CRP ATP600C ATP600CL ATU1000C/ ATU500C Note: Low voltage ATP ceiling sensors must use a CU series control unit. See page E-9 for details. See pages E-18 to E-21 for technical specifications, coverage patterns and wiring schematics. Low Profile, Line Voltage Passive Infrared Outstanding long range major motion detection in a compact low profile housing. Coverage Area Voltage Color Load Rating 120-347V AC with photocell White 800W Inc., 1000W Fl. @ 120V AC 1800W Fluorescent @ 277V AC 2200W Fluorescent @ 347V AC 1500 sq. ft. LVPR1500R ATP1500C/ ATP600C Ceiling Sensors Accessories Description Catalog Number Ceiling sensor infrared, NEMA 4X enclosure ACIPE Ceiling mount raceway adapter ACMRA Ceiling mount wire guard ACMG www.hubbell-wiring.com ACIPE ACMRA (R) ACMG Wiring Device-Kellems LVPR1500R E-7 H-MOSS(R) Controls Wall Mount Sensors and OPTIMYZER(R) High Bay, Low Bay Featuring Adaptive Technology Adaptive Technology Wall Mount Sensors * "Install and forget" operation * Swivel mounting bracket included for wall or ceiling mounting * All digital sensing technology * Compatible with most LED and CFL ATD1600W * Photocell for daylight harvesting and relay interface with auxiliary systems such as HVAC (RP models) * 24V DC, 33mA * CEC Title 24 Compliant *cULus Dual (Ultrasonic and Passive Infrared) Description Coverage Color Catalog Number Low voltage sensor 32kHz with photocell and isolated relay Low voltage sensor 32kHz 1600 sq. ft. 1600 sq. ft. Office White Office White ATD1600WRP ATD1600W Description Coverage Color Catalog Number Low voltage sensor with photocell and isolated relay Low voltage sensor Low voltage sensor for aisle and high bay applications, with photocell and isolated relay Low voltage sensor for aisle and high bay applications 1600 sq. ft. 1600 sq. ft. 120 linear feet Office White Office White Office White ATP1600WRP ATP1600W ATP120HBRP 120 linear feet Office White ATP120HB Passive Infrared ATP1600W, ATP120HB Note: All wall mount sensors must use a CU series control units. See page E-9 for details. See pages E-18 to E-21 for technical specifications, coverage patterns and wiring schematics. Wall Mount Sensors Accessories AWSG AWMG Description Catalog Number Wall switch wire guard AWSG Wall mount wire guard AWMG OPTIMYZER(R) High Bay and Low Bay Sensors * * * * * HMHB219 HMHBL180 HMHBLA HMHBL360 HMHBLEA Digital passive infrared (PIR) sensor Multiple (single and dual) output versions Single and dual timer operation Low-profile design No minimum load * Supports mounting heights up to 45 feet (High Bay) * Supports mounting heights between 8-16 feet (Low Bay) * Universal voltage (120/277/347V AC) models available Daylight Harvesting Passive Infrared Description Voltage Catalog Number Fluorescent high bay PIR sensor, 1 relay with photocell 120-347V AC HMHB219 Fluorescent high bay PIR sensor, 2 relays with photocell 120-347V AC HMHB229 Fluorescent high bay PIR sensor, 1 double pole relay with photocell 208/240V AC HMHB23A9 Fluorescent high bay PIR sensor, 1 double pole relay with photocell 480V AC HMHB23B9 Fluorescent high bay PIR sensor with photocell 24V DC HMHB2LV9* Note: 360 high bay lens included. Low bay lens options sold separately, see below for details. *For use with CU300HD (120/277V AC, 50/60Hz) control unit. See page E-22 for technical specifications and coverage patterns. Replacement Lenses and Accessories HMHBSA E-8 Description High Bay Low Bay 180 Lens HMHBL180 HMLBL180 360 Lens HMHBL360 HMLBL360 Aisle lens HMHBLA HMLBLA End of aisle lens HMHBLEA HMLBLEA Mounting extension adapter HMHBSA HMHBSA (R) Wiring Device-Kellems www.hubbell-wiring.com H-MOSS(R) Controls Daylight Harvesting and Control Units Featuring Daylight Harvesting and Load Control Daylight Harvesting * Multiple calibration options * Selectable 3- or 8-second dimming rate * Low-profile design * Light-sensitivity wide range of options Description Voltage Catalog Number Single zone continuous automatic dimming control Indoor photocell Outdoor photocell Atrium photocell Skylight photocell Control module Daylight tracker with ON/OFF control Daylight tracker with dimming control 10V DC 24V DC 24V DC 24V DC 24V DC 24V DC 24V DC 24V DC DHADC DHIP DHOP DHAP DHSP DHCM DHT* DHTD DHADC DHIP, DHOP DHAP, DHSP Note: *For use with CU series control units, see below for details. For use with 0-10V DC dimming ballasts. For use with DHCM and CU series control units. Control Units The CU300 series provides 24V DC power supply for sensors or sensor/Add-A-Relay combinations. The control units contain an internal relay for the control of an external load. Control units are plenum rated cULus Listed. Description Catalog Number Automatic-ON operation, 120/277V AC, 50/60Hz for use with 1 to 4 ATD, ATU and ATP series ceiling/wall mount sensors Manual-ON operation, 120/277V AC, 50/60Hz for use with 1 to 4 ATD, ATU and ATP series ceiling/wall mount sensors Auto or manual-ON operation, 120/277V AC, 50/60Hz for use with 1 to 6 ATD, ATU and ATP series ceiling/wall mount sensors, heavy duty latching relay for reactive loads and plug-load control Automatic-ON operation, 347V AC, 60Hz, for use with 1 to 3 ATD, ATU and ATP series ceiling and wall mount sensors CU300A CU300M CU300HD DHCM DHT CU300A(M), CU347A CU347A Note: See page E-19 for technical specifications. CU300HD Add-A-Relay Hubbell AAR Add-A-Relay contains an internal relay for control of an external load. The AAR requires a 24V DC power supply from the Hubbell CU series control unit. The AAR is typically used when it is desired to switch more than one circuit when occupancy is sensed or the load exceeds the maximum rating of the control unit. Description Catalog Number For use with CU series control units and Hubbell ATD, ATU and ATP series ceiling and wall mount sensors Heavy duty latching relay; for use with CU300HD in Plug load applications AAR AAR AAR20P Note: See page E-19 for technical specifications. AAR20P Enclosed 10 Amp SPDT Relays Description Catalog Number Enclosed relay 10 Amp SPDT with 10-30V AC/DC/120V AC coil AAR10C120 Enclosed relay 10 Amp SPDT with 10-30V AC/DC/208-277V AC coil AAR10C277 AAR10C277 Multi-Level Relays Description Catalog Number Enclosed independent control for multiple ballast light fixtures from one existing wall switch, bi-level; 120/208-277V AC AARBL2 Enclosed independent control for multiple ballast light fixtures from one existing wall switch, tri-level; 120/208-277V AC AARBL3 www.hubbell-wiring.com AARBL2 (R) Wiring Device-Kellems E-9 H-MOSS(R) Controls MAXXTM Harsh Environment Occupancy Sensors Features and Benefits H-MOSS|MAXX(R) products provide users with methods to reduce energy usage in harsh environments. These applications often have lights being left on and ventilation/HVAC systems constantly working. MAXXTM products are designed to withstand these challenging environments and provide increased operating efficiency. 1/2" threaded nipple (HAP4) IP66, NEMA 4X, outdoor rated Multiple mounting kits for existing work boxes and hubs; pendent or wall mounting flexibility Photocell makes sure lights stay off when there is sufficient daylight Isolated relay provides signalling to HVAC and ventilation systems Integrated lens guard protects against accidental damage Stainless steel hardware and settings access cover Housing manufactured from chemical resistant Valox(R) AHP1600WRP with HAP4 Fixture or work box mounting with 1/2" threaded nipple IP65, NEMA 3R watertight, and outdoor rated Digital passive infrared (PIR) sensor Two photocells for daylight harvesting Supplied with 360 lens; aisle, end-of-aisle and 180 lenses available separately HMHB21UPCW Valox(R) is a trademark of SABIC Innovative Plastics, acquired from General Electric Company. E-10 (R) Wiring Device-Kellems www.hubbell-wiring.com H-MOSS(R) Controls MAXXTM Harsh Environment Occupancy Sensors Featuring Passive Infrared Technology Watertight Wall Mount PIR Sensor IP66, NEMA 4X, outdoor rated, heavy duty wall or pendant mount sensor with -40F to 149F (-40C to 65C) operating temperature range and 160 of coverage. Description Voltage Catalog Number PIR sensor, with isolated relay and photocell 24V DC AHP1600WRP HAP1 Adaptor plate for single gang FS boxes -- Adaptor hub and nipple for Killark NJ series boxes -- HAP2 Adaptor plate for Killark(R) NV series boxes -- HAP3 1/2" NPT threaded hub -- HAP4 Note: For use with CU300HD (120/277V AC, 50/60Hz) control unit. See page E-22 for technical specifications and coverage patterns. AHP1600WRP Extreme Temperature PIR Ceiling Sensor Upgraded ceiling sensor with -40F to 149F (-40C to 65C) operating temperature range. Use ACIPE to make NEMA 4X watertight. Description Voltage Catalog Number Sensor with isolated relay and photocell 24V DC AHP1500CRP IP66, NEMA 4X enclosure ACIPE -- Note: For use with CU300HD (120/277V AC, 50/60Hz) control unit. See page E-22 for technical specifications and coverage patterns. AHP1500CRP with ACIPE Heavy Duty Control Unit Robust latching relay provides reliable performance over many different applications, including plug loads. 20A 100-277V AC, 1HP @ 120V AC, 2HP @ 240/277V AC. Auto or Manual-ON operation. Powers up to six low voltage sensors. Description Voltage Catalog Number Heavy duty control unit 120-277V AC CU300HD CU300HD Note: See page E-19 for technical specifications. OPTIMYZER(R) Watertight End Mount PIR Sensor IP65, NEMA 3R, outdoor rated, -40F to 149F (-40C to 65C) operating temperature range. Description Voltage Catalog Number Single relay with photocell 120-347V AC HMHB21UPCW 2 relays with photocell 120-347V AC HMHB22UPCW 1 double pole relay with photocell 208, 240V AC HMHB23APCW 1 double pole relay with photocell 480V AC HMHB23BPCW Low voltage with photocell 24V DC HMHB2LVPCW* HMHB21UPCW Note: 360 high bay lens included. Low bay lens options sold separately, see below for details. *For use with CU300HD (120/277V AC, 50/60Hz) control unit. See page E-23 for technical specifications and coverage patterns. Replacement Lenses Description High Bay Low Bay 180 Lens HMHBL180 HMLBL180 360 Lens HMHBL360 HMLBL360 Aisle lens HMHBLA HMLBLA End of aisle lens HMHBLEA HMLBLEA www.hubbell-wiring.com (R) Wiring Device-Kellems HMHBL180 HMHBL360 HMHBLA HMHBLEA E-11 H-MOSS(R) Controls Plug Load Control Products System Overview / Methods for Complaince ASHRAE 90.1-2010 mandates that 50% of all outlets in private offices, open offices, and computer classrooms must be automatically controlled by occupancy or time based schedules. This also includes outlets in modular furniture. Hubbell provides solutions for compliance that are cost effective and installer friendly. Bellow are two examples. Additional examples and design resources are located at www.hubbell-wiring.com/energy.aspx Wired BR15C1WHI Utilizing low voltage wiring provides installers with a familiar method of wiring and installation. Specify CU300HD to control outlets and use AAR or CU300A to control the lighting. Utilize alternating outlet or split receptacle wiring as required to control at least 50% of the outlets in the space. CU300HD Controlling 50% of Outlets BR20C2WHI Wireless Wireless communication takes complexity out of retrofit and difficult installations by eliminating low voltage wires running between lighting and receptacle control units. This gives installers flexibility to quickly deploy, add additional devices, and configure and re-configure the system as needed. Hubbell's WL series controls utilize Clear ConnectTM communication and are compatible with other Clear ConnectTM devices, such as Hubbell's wireless occupancy sensors. WLC301 DR15C1I Controlling 50% of Outlets DR20C2I Clear ConnectTM is a registered trademark of Lutron Electronics Co., Inc. E-12 (R) Wiring Device-Kellems www.hubbell-wiring.com H-MOSS(R) Controls Plug Load Control Products Featuring Clear ConnectTM Technology Hubbell Plug Load Control Products * Wired or wireless flexibility * Listed for 20A enclosed switching * Heavy duty 60A rated mechanical latching relay; silver alloy contacts * 24V DC, 250mA DC power output on applicable units * Low voltage output short circuit protection * UL2043 plenum rated except WLC402W * Compatible with most LED and CFL * Zero cross switching Wired Heavy Duty Control Unit Robust latching relay provides reliable performance over many different applications, including plug loads. 20A 100-277V AC, 1HP @ 120V AC, 2HP @ 240/277V AC. Auto or Manual-ON operation. Powers up to six low voltage sensors. Description Voltage Catalog Number Heavy duty control unit 100-277V AC CU300HD CU300HD AAR20P Heavy duty latching relay; for use with CU300HD Note: See page E-25 for technical specifications and wiring schematics. Straight Blade Specification Grade Receptacles Pre-Marked for Plug Load Applications Description Color 15A Duplex 20A Duplex 15A Decorator 20A Decorator Receptacles marked permanently for Plug Load applications Ivory Light Almond White BR15C1I BR15C1LA BR15C1WHI BR20C2I BR20C2LA BR20C2WHI DR15C1I DR15C1LA DR15C1WHI DR20C2I DR20C2LA DR20C2WHI Note: See Section A for additional products and colors. BR15C1WHI DR20C2I Wireless Operates in a "quiet" 434MHz FCC band. Range: 30 feet obstructed or 60 feet line of sight. Heavy Duty Control Unit with Wireless Transmitter CU300HD with functionality of WLCA integrated to wirelessly activate additional load control units. 20A 100-277V AC, 1HP @ 120V AC, 2HP @ 240/277V AC. Auto or Manual-ON operation. Powers up to six low voltage sensors. Description Voltage Catalog Number Heavy duty control unit with Clear ConnectTM 100-277V AC WLCU301 WLCU301 Wireless Status Transmitter Low voltage powered unit transmits occupancy or timer status to associated load control receivers. Use with CU300xx and low voltage sensors/timers to upgrade existing lighting control systems to support plug load control. Description Voltage Catalog Number Wireless transmitter with Clear Connect, for use with CU300xx 24V DC WLCA WLCA Heavy Duty Load Control Units with Wireless Receiver These units receive wireless Clear ConnectTM commands to turn ON and OFF power to downstream loads. Utilize these control units to wirelessly switch a circuit of receptacles or any other applicable load. 20A 100-277V AC, 1HP @ 120V AC, 2HP @ 240/277V AC. Description Voltage Catalog Number Single (1) circuit heavy duty control unit with Clear ConnectTM 100-277V AC WLC301 Dual (2) circuit heavy duty control unit with Clear ConnectTM 100-277V AC WLC302 WLC301 WLC302 Furniture Feed Box with Heavy Duty Relays and Wireless Receiver Furniture feed box receives wireless Clear ConnectTM commands and controls two circuits in furniture electrical feeds. It supports wall mounting to existing 1 or 2-gang junction boxes. Additionally, the box can be secured to the furniture or on the floor. 20A 100-277V AC, 1HP @ 120V AC, 2HP @ 240/277V AC. Description Voltage Catalog Number Dual (2) circuit heavy duty furniture feed box with Clear ConnectTM 100-277V AC WLC402W Note: See page E-25 for technical specifications and wiring schematics. WLC402W Clear ConnectTM is a registered trademark of Lutron Electronics Co., Inc. www.hubbell-wiring.com (R) Wiring Device-Kellems E-13 H-MOSS(R) Controls WL-Series Wireless Sensors and Controls Features and Benefits Three operation modes available: Auto-ON, Auto-ON Low-Light and Manual-ON Passive infrared motion detection with advanced digital signal processing for fine motion detection Lens illuminates during test mode to verify coverage Adjustments available for Timeout, Activity, and Auto-ON settings Auto-ON Low-Light feature will only turn lights on automatically if there is less than approximately 10 Lux (1 foot candle) of ambient light Accessible test buttons make setup easy WLP450C 10-year battery life design LED and CFL compatible with supplied load adaptor 8A lighting, 3A fan load capacity Digital push button operation provides user control Green LED provides operation and setup feedback Service switch prevents lights from coming on during re-lamping No neutral required, no leakage to ground WLS1278W Clear ConnectTM is a registered trademark of Lutron Electronics Co., Inc. E-14 (R) Wiring Device-Kellems www.hubbell-wiring.com H-MOSS(R) Controls WL-Series Wireless Sensors and Controls Featuring Clear ConnectTM Technology Hubbell's WL-Series Wireless Sensors and Controls are the ideal solution for renovation projects aimed at reducing energy consumption. These sensors use DSP Enhanced passive infrared technology to detect movement of heat from people to turn lights ON when a room is occupied and OFF when vacant. The sensors wirelessly transmit Clear ConnectTM commands to the associated control devices, reducing the need for additional wiring for ease and speed of installation and energy savings. * Eliminates need to run extra wires * Supports highly reconfigured spaces * Helps complete projects quickly * Helps manage energy consumption * Compatible with must LED and CFL Wireless Ceiling and Wall Mount Sensors Wireless Wall Switches Wireless Wall Mount Sensor Wireless Daylight Sensor Wireless Wall Switches Description Color Catalog Number 8A Lighting, 3A Fan (1/10 HP motor, 120V AC only), Spec Grade Electronic Switch 120-277V AC; no neutral wire required Ivory White WLS1278I WLS1278W Accessory Switch 120V AC Ivory White WLAS120I WLAS120W Accessory Switch 277V AC Ivory White WLAS277I WLAS277W WLS1278I WLAS277W Compatible Transmitters: WLP series and WLDH sensors, or any Lutron Clear Connect enabled sensor. Wireless Ceiling Mount Sensor Description Color Catalog Number Ceiling mount 360 / 324-676 sq. ft. White WLP450C Wireless Wall Mount Sensor WLP450C * Detection at longer distances is best when motion occurs at right angles to the sensor * Mount Hallway Sensor at the end of a hallway with a clear view down the length of a hall * Multiple sensors can be used to extend coverage Description Wall mount 180 / 3000 sq. ft. Corner mount 90 / 2500 sq. ft. Hallway up to 150 linear feet Color White White White Catalog Number WLP3000W WLP2500W WLP150H Compatible Controls: WSL1278xx switch, WLC316R control unit, or any Lutron Clear Connect enabled control device. WLP150H Wireless Control Unit Description Catalog Number Wireless load control unit with isolated relay, 16A, 120V AC or 277V AC WLC316R Compatible Transmitters: WLP series and WLDH sensors, or any Lutron Clear Connect enabled sensor. WLC316R Wireless Daylight Sensor Description Color Catalog Number Daylight sensor 0-107,000 Lux (0-10,000 foot candles) White WLDH Compatible Controls: WSL1278xx switch, WLC316R control unit, or any Lutron Clear Connect enabled control device. Note: See pages E-26 to E-28 for technical specifications, coverage patterns and wiring schematics. WLDH Clear ConnectTM is a registered trademark of Lutron Electronics Co., Inc. www.hubbell-wiring.com (R) Wiring Device-Kellems E-15 H-MOSS(R) Controls Specifications and Coverage Patterns Wall Switches Adaptive Dual Technology Wall Switches Adaptive Technology Ultrasonic and PIR Wall Switches Electrical Power Supply Load Capacity Incandescent 120V Ballast 277V Ballast Motor Load Agency Approvals AD2000 Series 120/277V AC, 50/60Hz AP2000 and AU2000 Series Minor Motion: Ultrasonic 120/277V AC, 50/60Hz 0 to 800 watts 0 to 1000 watts 0 to 1800 watts 1/4HP cULus Listed 0 to 800 watts 0 to 1000 watts 0 to 1800 watts 1/4HP cULus Listed Physical Housing Lens Dimensions Mounting Height Wall Switches Coverage Patterns PIR Minor Motion: Ultrasonic PIR Major Motion: Ultrasonic PIR Major Motion: 26' 21' 28' 29' 24' High impact plastic (UL 94-5V) Dual element pyrometer and 12 element cylindrical hard lens (AP2000 only) Face 2.57"H x 1.71"W, 0.53"D (from wall out) 42 to 54 inches above floor Environmental Operating 32 F to 104F (0C to 40C); 0% to 95% non-condensing relative humidity Controls Time Delay Digital, adaptive 4 to 30 minutes 28' 50' AD2000 Series Ambient Light Front Press Switch Sensitivity Service Switch Digital, adaptive 4 to 30 minutes 20 minutes default Adjustable ambient light override, 10 to 500 foot candles Auto/OFF Auto/OFF Adaptive 0% to 100% Adaptive 0% to 100% Air gap OFF Air gap OFF Sensing Indicator Passive Infrared Red LED (AD series only) Red LED (AP series only) Ultrasonic Green LED (AD series only) Green LED (AU series only) 28' 28' 50' AP2000 Series 21' 14.5' 24' 14.5' 26' AU2000 Series Wiring Schematic AD, AU, AP, 2000 Series Wall Switch Sensors Single Circuit Wiring 120/277V AC Black Red Dual Circuit Sensor, Wired for Dual Circuits Line circuit 1 120/277V AC Black Red Load 1 Line circuit 120/277V AC Black Load 1 For step dimming, bi-level, and dual ballasted fixtures Green Ground Green Ground Blue Load 2 White Single Circuit Sensors, Wired as 3-Way Sensors* Green Blue Load 2 Dual Circuit Sensors, Wired as 3-Way Sensors* Lighting Load A Green Ground Neutral Hot Hot Black Red Load 1 Green Ground Ground Neutral Dual Circuit Sensor, Wired for Dual Circuits with Neutral Lighting Load A Black Red Red Blue Lighting Load B Note: *Load can not exceed the rating of one switch. Sensor is shipped with all dip switches in the OFF position (factory default). E-16 (R) Wiring Device-Kellems www.hubbell-wiring.com Ultrasonic H-MOSS(R) Controls Specifications and Wiring Schematics Wall Switches Adaptive Technology PIR Wall Switches ATP2000, WS2000 and WS1000 Series Wall Switches Coverage Patterns Electrical Power Supply Load Capacity Incandescent 120V Ballast 277V Ballast Agency Approvals Warranty ATP/WS2000 Series 120/277V AC, 60Hz WS1000 Series 120V AC, 60Hz 0 to 1000 watts 0 to 1000 watts 0 to 1800 watts cULus Listed 5 years 0 to 500 watts 0 to 500 watts N/A cULus Listed 5 years Physical Housing Lens Dimensions Mounting Height ATP/WS2000 and WS1000 Series Flame retardant UL 94 V-0 ABS Polyethylene Face 2.59"H x 1.30"W, 0.61"D (from wall out) 42 to 54 inches above floor Environmental Operating ATP/WS2000 and WS1000 Series 32F to 122F (0C to 50C) with rate of change not exceeding 20F (11C) per hour; 20% to 90% non-condensing relative humidity -40F to 150F (-40C to 65C); 20% to 90% non-condensing relative humidity Storage Controls Time Delay Ambient Light Front Press Switch Service Switch Sensing Indicator Passive Infrared ATP/WS2000 Series ATP: Auto WS: Manual 20 seconds to 30 minutes Digital, pushbutton, 10 to 500 foot candles ON/OFF OFF (service) Vac (manual-ON) Occ (auto-ON) Minor Motion: PIR Major Motion: PIR 16' 12' 12' 16' 20' 40' ATP2000, WS1000, WS2000 Series WS1000 Series Manual 20 seconds to 30 minutes Mounting Height 48" (121.9 cm) N/A 20' (6.1m) 40' (12.2m) ON/OFF OFF (service) ON (normal operation) Vertical Coverage ATP2000, WS1000, WS2000 Series ATP/WS2000 and WS1000 Series Red LED Wiring Schematic ATP2000, WS1000 and WS2000 Series Wall Switches Sensors Wired as 3-Way Sensors* Normal Wiring (ATP/WS2000 Only) Neutral White (Neutral Version Only) Load Neutral White (Neutral Versions Only) Load Hot Red Black Black White Hot Yellow Red Red Green ATP/WS2000 Only Ground Green Green Yellow Ground Note: *Load can not exceed the rating of one switch. www.hubbell-wiring.com (R) Wiring Device-Kellems E-17 H-MOSS(R) Controls Specifications and Coverage Patterns Ceiling and Wall Mount Sensors Adaptive Dual Technology, Ultrasonic and Passive Infrared Ceiling and Wall Mount Sensors ATD, ATU, and ATP Series Electrical Power Requirements Isolated Relay (sensors with RP suffix) Agency Approvals 24V DC nominal, 33mA from Hubbell CU series control unit Normally open and normally closed; terminals available Physical Ceiling Sensors Wall Mount Sensors Housing Lens Dimensions Color Mounting Height Flame retardant UL 94 V-0 ABS Polyethylene 1.5"H x 4.5"D Office white 8 to 12 feet Flame retardant UL 94 V-0 ABS Polyethylene 6"H x 2"W x 1.5"D Office white 8 to 12 feet, 8 to 30 feet (ATP120HB series) UL Listed Environmental Operating 32F to 104F (0C to 40C) with rate of change not exceeding 20F (11C) per hour; 0% to 95% non-condensing relative humidity -20F to 150F (-29C to 65C); 0% to 95% non-condensing relative humidity Storage Controls Time Delay Ambient Light Sensitivity Test (8 seconds), adaptive 8 to 40 minutes 1 to 1000 foot candles Adaptive 0 to 100% Sensing Indicators Ultrasonic (ATD and ATU Series) Green LED Passive Infrared (ATD and ATP Series) Red LED Ceiling Sensors Coverage Patterns Minor Motion: Ultrasonic PIR Major Motion: Ultrasonic 22' 12' PIR 12' 32' 23' 22' 12' 32' 23' 45' 20' 23' 64' ATD2000C Series 45' 18' 26' ATD500C Series 64' 32' 23' 11' 7' 12' 14' 32' ATD1000C Series 11' 7' 22' 22' 23' ATP1500C Series 32' 32' 23' 17' 23' 23' 17' 64' 16' ATP600C Series ATU2000C Series ATU1000C Series ATU500C Series 20' 64' 16' ATU2000C Series Hallway Application E-18 LVPR1500R(P) (R) Wiring Device-Kellems www.hubbell-wiring.com H-MOSS(R) Controls Specifications and Coverage Patterns Ceiling, Wall Mount Sensors and Control Units Wall Mount Sensors Coverage Patterns Minor Motion: 23' Ultrasonic 32' PIR 23' Major Motion: Ultrasonic PIR 32' 120' 7' 7' 32' ATP120HB Series Top View 32' 23' 23' 120' 30 20 20' 20' 40' 20' 40' 10 20' 40' ATD1600W Series 0 40' ATP1600W Series Side View Control Units - CU300/347A Series Electrical CU300A(M) CU347A CU300HD Power Supply Power Output Load Capacity Incandescent, LED & CFL 120V Ballast 230V Ballast 277V Ballast 347V Ballast AT Sensor/AAR Capacity Agency Approvals 120-277V AC, 50/60Hz 24V DC, 150mA 347V AC, 60Hz 24V DC, 100mA 100-277V AC, 50/60Hz 24V DC, 250mA 0 to 1800 watts 0 to 2400 watts N/A 0 to 5540 watts N/A 1 to 4 combined UL Listed, cULus Certified N/A N/A N/A N/A 0 to 5205 watts 1 to 3 combined UL Listed, cULus Certified 20A, 100-277V AC; 1HP @ 120V AC, 2HP @ 240/277V AC Motor Loads: 1HP @ 120V 2HP @ 240/277V 1 to 6 combined UL Listed, cULus Certified Physical Housing Dimensions Color Flame retardant UL 94-5VA thermoplastic 3.69"L x 2.33"W x 1.36"H Black Flame retardant UL 94-5VA thermoplastic 4.00"L x 3.4"W x 1.73"H Black 32F to 104F (0C to 40C); 0% to 90% non-condensing relative humidity -20F to 150F (-29C to 65C); 0% to 90% non-condensing relative humidity -40F to 149F (-40C to 65C). Below 32F (0C) must use suitably rated non-metallic enclosure. 0% to 90% humidity, non-condensing Environmental Operating Storage Add-A-Relay Control Units Electrical AAR AAR20P Power Input Load Capacity Incandescent, LED & CFL 120V Ballast 230V Ballast 277V Ballast 347V Ballast AT Sensor/AAR Capacity Agency Approvals 24V DC nominal, 33mA from Hubbell CU series control unit 24V DC nominal, 50mA from Hubbell CU300HD series control unit 20A, 100-277V AC; 1HP @ 120V AC, 2HP @ 240/277V AC Motor Loads 1HP @ 120V 2HP @ 240/277V 0 to 1800 watts 0 to 2400 watts 0 to 3680 watts 0 to 5540 watts 0 to 5205 watts UL Listed 1 to 6 combined UL Listed, cULus Certified Flame retardant UL 94-5V thermoplastic 3.69"L x 2.33"W x 1.36"H Black Flame retardant UL 94-5VA thermoplastic 4.00"L x 3.4"W x 1.73"H Black 32F to 104F (0C to 40C); 0% to 90% non-condensing relative humidity -20F to 150F (-29C to 65C); 0% to 90% non-condensing relative humidity -40F to 149F (-40C to 65C). Below 32F (0C) must use suitably rated non-metallic enclosure. 0% to 90% humidity, non-condensing Physical Housing Dimensions Color Environmental Operating Storage www.hubbell-wiring.com (R) Wiring Device-Kellems E-19 H-MOSS(R) Controls Wiring Schematics Ceiling and Wall Mount Sensors Adaptive Dual Technology, Ultrasonic, and Passive Infrared Ceiling and Wall Mount Sensors ATD, ATU and ATP Series Single Circuit Application: 1 to 4 sensors wired to control unit with optional override off switch. CU Series Control Unit CU Series Control Unit N H Red Switch* Red Red Blue Red Blk Blue Red Blk Blue Red Blk Blue Red Blk Red (+24V) Black Blue Black White Red Blue White Red Red Black Blue Black Blk N H Single Circuit Application: Two control units wired in parallel to operate 5 to 8 sensors in a single zone. Maximum 4 sensors per control unit any sensor will activate lighting. ATD, ATU and ATP Series Sensors** ATD, ATU and ATP Series Sensors** Lighting Load Lighting Load White Blue Black *Optional Override Off Switch CU Series Control Unit Two Circuit Application: 1 to 4 sensors wired to control unit and Add-A-Relay (control unit switches circuit 1, Add-A-Relay switches circuit 2). White Red Blk Red Blue Blue Red Red White Blk Red (+24V) Black Blue Black Lighting Load CU Series Control Unit CU Series Control Unit N H White Red Red Black Blue Blue Circuit 2 N H Red Red Red (+24V) Black Blue Black AAR Add-A-Relay Blk Circuit 1 Blue Lighting Load Red ATD, ATU and ATP Series Sensors** Two Circuit Application: Two control units wired in two circuits to operate 2 to 8 sensors in a single zone. Maximum 4 sensors per control unit any sensor will activate both lighting loads. Blk Red Red Blk Blue Red Blue White Red Red Black Blue Black Blk Circuit 1 N H Red Red ATD, ATU and ATP Series Sensors** Lighting Load White CU Series Control Unit (Specify Voltage) E-20 (R) Red Blue Red Red Blk White Blue Red (+24V) Black Blue Black Red Circuit 2 N H Note: **For wiring sensors with isolated relay and photocell option (models with "RP" suffix): Photocell Option: Cap off Blue sensor wire. Connect Gray sensor wire to Blue control unit wire. Isolated Relay Option: Common-Blue/White wire, Normally Closed-Black/White wire, Normally Open-Yellow/White wire. Black Blk Lighting Load Blue Lighting Load White Wiring Device-Kellems www.hubbell-wiring.com H-MOSS(R) Controls Wiring Schematics Ceiling and Wall Mount Sensors Adaptive Technology Dual, Ultrasonic, and Passive Infrared Ceiling and Wall Mount Sensors ATD, ATU and ATP Series Single Circuit, Dual Level Switching Application: 1 to 4 sensors wired to control unit with optional override off switches. Single Circuit, 3-Way Switching Application: 1 to 4 sensors wired to control unit with optional override off switches. Traveler Traveler Single Pole Switch Red Blk 3-Way Switch 3-Way Switch Red Blue Blk Blue Red Blk Blue Red Inboard Ballast Single Pole Switch Red CU Series Control Unit (Specify Voltage) Red Blk Red Red Blk Black Blue Blue Blue Red Black White Lighting Load Outboard Ballast CU Series Control Unit (Specify Voltage) Red White ATD, ATU and ATP Series Sensors** H N Red Red Blk Black Blue Blue Black White White N H ATD, ATU and ATP Series Sensors** Multi-Circuit Application: 1 to 4 sensors wired to control unit that is wired to a multi-pole lighting contactor. Single Circuit, 4-Way Switching Application: 1 to 4 sensors wired to control unit with optional override off switches. CU Series Control Unit N Traveler H Red (+24V) Black Traveler Black White Blue Red Blk Blue Red Blk Blue Red 3-Way Switch Red 4-Way Switch 3-Way Switch Blk Red Blue Lighting Contactor Traveler CU Series Control Unit (Specify Voltage) ATD, ATU, ATP, PIR Series Sensors** Red Red Blk Blue Multipole, Normally Open Lighting contactor to be supplied by Contractor Lighting Load C White Red Red Red Blk Black Blue Blue ATD, ATU and ATP Series Sensors** Black White White H N Note: **For wiring sensors with isolated relay and photocell option (models with "RP" suffix): Photocell Option: Cap off Blue sensor wire. Connect Gray sensor wire to Blue control unit wire. Isolated Relay Option: Common-Blue/White wire, Normally Closed-Black/White wire, Normally Open-Yellow/White wire. www.hubbell-wiring.com (R) Wiring Device-Kellems E-21 H-MOSS(R) Controls Specifications and Coverage Patterns OPTIMYZER(R) High Bay Controls and Harsh Environment Sensors OPTIMYZER(R) High Bay Controls HMHB Series User Interface Timer time-outs Passive infrared Daylight sensor Coverage Load ratings (line voltage units) Operating environment Construction Size and weight Color Mounting Certifications Warranty Coverage Pattern (1) twelve pin dip switch Primary: 8-second test mode, 4, 8, 16 and 30 minute time-outs Secondary: (Can be disabled) 30, 60 and 90 minute time-outs Dual element pyrometer and spherical Fresnel lens Dual element pyrometer and spherical Fresnel lens designed for robust detection of a walking person* 360 lens provided, 180 aisle and end-of-aisle lenses also available 120V AC: 0 to 800W ballast or tungsten 208/240V AC: 0 to 1200W ballast 277V AC: 0 to 1200W ballast 480V AC: 0-2400W ballast 347V AC: 0 to 1500W ballast 1/4 HP motor load @ 120V AC, HP @ 347V AC Output (Low voltage sensors): * 24V DC active high-logic control signal * Relay: N/O + N/C contacts; 500mA rated @ 24V DC; 3-wire isolated relay Indoor use only Operating temperature: (standard version) 32F to 149F (0C to 65C); Relative humidity (non-condensing): 0% to 95% Casing: High-impact injection-molded thermoplastic Size: 4.0" Diameter x 1.5" Height; Weight: 7 oz. White Mounts directly to end of a fixture through an extended 1/2 inch chase nipple for deeper body fixtures, an optional Extender Adapter (HMHBSA available separately) positions the sensor flush or below the bottom of the reflector for a full field of view cULus Listed 5 year limited Minor Motion: Major Motion: PIR PIR H = 0' to 30' R1 = 1.4 x H R1 H = 30' to 45' R2 R2 = 1.1 x H Note: *When used with program start ballast, a 1-2 second delay from occupancy detection to lamp turn-on may be experienced. MAXXTM Harsh Environment Occupancy Sensors AHP Series Electrical Power Requirements Isolated Relay (sensors with RP suffix) Agency Approvals Physical Housing Protection Lens Dimensions Color Mounting Height Physical Environmental Operating Controls 22' 12' Time Delay Ambient Light Sensitivity Sensing Indicators 32' 23' Infrared Passive 45' Coverage Pattern 40' 22' 32' 23' 12' 20' 23' 64' (R) PIR 40' AHP1600WRP Test (8 seconds), adaptive 8 to 4012' minutes 1 to 1000 foot candles Adaptive 0 to 100% Red LED Major Motion: PIR 20' 20' -40F to 149F (-40C to 65C) with rate of change not exceeding 20F (11C) per hour; 0% to 95% non-condensing relative humidity 22' 22' 12' 11' 7' 14' 32' Valox(R) is a trademark of SABIC Innovative Plastics, acquired from General Electric Company. E-22 Minor Motion: 32' 24V DC nominal, 33mA from Hubbell CU series control unit 23' Normally open and normally closed Terminals available cULus Listed Ceiling Sensor (R) Flame retardant UL 94 V-0 ABS Flame retardant 32' UL 94 V-0 Valox NEMA 4X, when used with ACIPE NEMA 4X, IP66, outdoor use rated Polyethylene 23' Polyethylene 6"H x 2"W x 1.5"D 4.5" Diameter x 1.5" Height Gray Office White 8 to 12 feet 8 to 12 feet Wall Mount Sensor Wiring Device-Kellems 18' 26' AHP1500CRP www.hubbell-wiring.com H-MOSS(R) Controls Specifications and Coverage Patterns MAXXTM OPTIMYZER(R) and HMLBL 360 MAXXTM OPTIMYZER(R) Watertight End Mount PIR Sensor HMHBxxUPCW Series User Interface Timer time-outs Passive infrared Daylight sensor Coverage Load ratings (line voltage units) Operating environment Construction Size and weight Color Mounting Certifications Warranty Coverage Pattern (1) twelve pin dip switch Primary: 8-second test mode, 4, 8, 16 and 30 minute time-outs Secondary: (Can be disabled) 30, 60 and 90 minute time-outs Dual element pyrometer and spherical Fresnel lens Dual element pyrometer and spherical Fresnel lens designed for robust detection of a walking person* 360 lens provided, 180 aisle and end-of-aisle lenses also available 120V AC: 0 to 800W ballast or tungsten 208/240V AC: 0 to 1200W ballast 277V AC: 0 to 1200W ballast 480V AC: 0-2400W ballast 347V AC: 0 to 1500W ballast 1/4 HP motor load @ 120V AC, HP @ 347V AC Output (Low voltage sensors): * 24V DC active high-logic control signal * Relay: N/O + N/C contacts; 500mA rated @ 24V DC; 3-wire isolated relay Indoor and outdoor use Operating temperature: -40F to 149F (-40C to 65C) Casing: High-impact injection-molded thermoplastic Size: 4.0" Diameter x 1.5" Height; Weight: 7 oz. White Mounts directly to end of a fixture through an extended 1/2 inch chase nipple for deeper body fixtures, an optional Extender Adapter (HMHBSA available separately) positions the sensor flush or below the bottom of the reflector for a full field of view Conforms to UL STD 508, UL STD 244A, Conforms to IP65 5 year limited Minor Motion: Major Motion: PIR PIR H = 0' to 30' R1 = 1.4 x H R1 H = 30' to 45' R2 R2 = 1.1 x H Note: *When used with program start ballast, a 1-2 second delay from occupancy detection to lamp turn-on may be experienced. OPTIMYZER(R) Low Mount Lens Modification HMLBL 360 Coverage Patterns Minor Motion: PIR Major Motion: PIR Top View 24' HMLBL360 Side View 8' 24' 48' www.hubbell-wiring.com (R) Wiring Device-Kellems E-23 H-MOSS(R) Controls Specifications and Coverage Patterns MAXXTM OPTIMYZER(R) OPTIMYZER(R) High Bay Controls HMHB Series, Low Voltage Sensor with Control Unit Neutral Hot Lighting Load A O v erride S w itch (O p tional) O N When O ccup ied Low Voltage S ensors(dev ices) Red Red Red (+ 24 VD C ) Red (+ 24 VD C ) Black (com m on) Black (com m on) Black White Blue (control) Blue (control) C U 3 0 0 A(M ) C U 3 0 0 HD f or M AX X TM P ow er P ack Version G ray (O ccup ancy and P hoto S ensor C ontrol) Blue/ White (Relay C om m on) Black/ White (Relay Norm ally C losed) Y ellow / White (Relay Norm ally O p en) Lighting Load B O v erride S w itch (O p tional) O N When O ccup ied + Low Light Lev el Red (+ 24 VD C ) Red Red Black (com m on) Blue (control) AAR or AAR20 P f or M AX X TM S lav e P ack Version Phase 2 To Next Device Phase 1 Violet White Black Lighting Load Phase 1 Red OPTIMYZER(R) High Bay Controls HMHB Series, Dual Relay, Single Fixture Blue OPTIMYZER(R) High Bay Controls HMHB Series, Dual Relay, Two Fixtures Neutral Neutral Hot White White Lighting Load B Black Black Black G ray Lighting Load A Black S ingle F ix ture Lighting Load A B Violet (2-Relay Version) White (Neutral) White Violet (2-Relay Version) White (Neutral) Black Hot Red Red Blue (2-Relay Version) E-24 Phase 2 (R) Wiring Device-Kellems Blue (2-Relay Version) www.hubbell-wiring.com H-MOSS(R) Controls Specifications and Wiring Schematics Plug Load Control Products WLC Load Control with Wireless Clear Connect Communication Electrical Power Supply Power Output Circuits Controlled Load Capacity Agency Approvals Device Type (Transmit or Receive) Range (Standard/ Obtructed) Range (Unobstructed, line of sight) Physical Housing Dimensions Color WLCA 24V DC N/A N/A WLCU301 WLC301 WLC302 100-277V AC, 50/60Hz 100-277V AC, 50/60Hz 100-277V AC, 50/60Hz 24V DC 250mA N/A N/A 1 1 2 100-277V AC, 20A 100-277V AC, 20A 100-277V AC, 20A 1HP @ 120V AC 1HP @ 120V AC 1HP @ 120V AC 2HP @ 240/277V AC 2HP @ 240/277V AC 2HP @ 240/277V AC UL Listed, cULus, FCC, IC, UL/cUL 916 listed for energy management equipment TX TX RX RX WLC402W 100-277V AC, 50/60Hz N/A 2 100-277V AC, 20A 1HP @ 120V AC 2HP @ 240/277V AC 30 ft. (10m) 30 ft. (10m) 30 ft. (10m) 30 ft. (10m) 30 ft. (10m) 60 ft. (30m) 60 ft. (30m) 60 ft. (30m) 60 ft. (30m) 60 ft. (30m) Black Black Flame retardant UL 94-5VA thermoplastic 4.00"L x 3.4"W x 1.73"H Black Black RX 4.68"L x 4.94"W x 2.78"H White Wired Lighting and Plug Load Control CU300HD Controlling 50% of Outlets Wireless Lighting and Plug Load Control Easily upgrade existing occupancy based lighting control systems to support automated plug load controls. WLC301 Controlling 50% of Outlets WLC301 Controlling 50% of Outlets Use WLC302 or -402 for dual circuit control Clear ConnectTM is a registered trademark of Lutron Electronics Co., Inc. www.hubbell-wiring.com (R) Wiring Device-Kellems E-25 H-MOSS(R) Controls Specifications and Coverage Patterns WL-Series Wireless Sensors Wireless Wall Switch (WLS1278 Series) Operating voltage: 120/277V AC, 50/60Hz; Green indicator light Indoor use only Ambient operating temperature: 32F to 104F (0C to 40C); relative humidity: 0% to 90% humidity, non-condensing #20 to 16 AWG (0.5 to 1.5mm2) solid or stranded wire Up to 9 WLAS accessory switches can be configured to work together with one WLS1278 RF range is 30 ft. (10m) obstructed, 60 ft. (18m) line of sight UL Listed, CSA Certified, FCC Approved; Complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules 1 year Range Diagram Wireless Control Unit (WLC316R) Electrical Operating Environment Load Isolated Relay Range Certifications Warranty Operating voltage: 120/277V AC, 50/60Hz LED status indicator: displays load status and provides programming feedback Power failure memory: (Relay returns to previous level prior to interruption) Output is non-latching Indoor use only Ambient operating temperature: 32F to 131F (0C to 55C); Relative humidity: 0% to 90% humidity, non-condensing Maximum load: 16A general purpose. No minimum Motor rating: 0.5 HP (120V AC), 1.5 HP (277V AC) Normally open (NO) and normally closed (NC) dry contacts Maintained latching output The isolated relay is not rated to control unclamped, inductive loads Inductive loads include, but are not limited to relays, solenoids and motors to control these types of equipment RF range is 30 ft. (10m) obstructed, 60 ft. (18m) line of sight UL Listed, UL 2043 Plenum Rated, FCC Approved. Complies with the limits for a Class B device, pursuant to Part 15 of the FCC rules. CSA and IC 1 year Install in center of room to maximize RF coverage. Wireless Occupancy Sensor 30 ft (10 m) Electrical Operating Environment Wire Size Capacity Range Certifications Warranty 30 ft (10 m) Maximum Wireless Transmitter must be installed within 30 ft (10 m) of the load control unit. 40 ft (12 m) Line of sight distance 60 ft (18 m) Contact Hubbell first for applications using foil-backed or metallic ceiling tiles. Contact Hubbell first for applications using foil-backed or metallic ceiling tiles. Wireless Sensor Coverage Patterns Ceiling Mount WLP450C Top View Wall Mount WLP3000W Top View Corner Mount WLP2500W Top View 25' 18' 50' 35' 0' 18' 25' 50' 60' 7' 11' Side View Side View Side View 8' 50' 60' 7 50' 0 6' 7 35' 0 12' Sensor Coverage Chart (for sensor mounted in center of room) Ceiling height 8 ft. (2.4m) 9 ft. (2.7m) 10 ft. (3.0m) 12 ft. (3.7m) Maximum room dimensions for complete floor coverage* 18 ft. x 18 ft. (5.5m x 5.5m) 324 sq. ft. (30.2m2) 20 ft. x 20 ft. (6.1m x 6.1m) 400 sq. ft. (37.2m2) 22 ft. x 22 ft. (6.7m x 6.7m) 484 sq. ft. (44.9m2) 26 ft. x 26 ft. (7.9m x 7.9m 676 sq. ft. (62.4m2) Note: *12 ft. (3.7m) is the recommended maximum mounting height. Clear ConnectTM is a registered trademark of Lutron Electronics Co., Inc. E-26 (R) Wiring Device-Kellems www.hubbell-wiring.com H-MOSS(R) Controls Specifications and Coverage Patterns WL-Series Wireless Sensors Wireless Hallway Sensor Electrical Operating voltage: 3V Operating current: 14 A nominal 10-year battery life design Supplied with one CR 123 lithium battery Non-volatile memory (saved changes are stored during power loss) Construction High impact, UL 94-5V plastic Operating Environment Indoor use only Operating temperature: 32F to 104F (0C to 40C) Range RF range is 30 ft. (10m) obstructed, 60 ft. (18m) line of sight Sensor Coverage Test Dedicated test button Lens illuminates orange in response to motion during test mode Wireless Communication Test Dedicated test button; Turn associated loads ON and OFF Time Out Options 1 minute (intended for use in high-activity, briefly occupied areas only); 5 minutes; 15 minutes (default setting); 30 minutes Auto-On Options "Enabled" - Sensor turns lights ON and OFF automatically - default setting "Disabled" - Lights must be turned ON manually from a switching device Sensor turns lights OFF automatically Sensitivity Options Low Activity (default setting); Medium Activity; High Activity Certifications cULus Listed, FCC Certified, IC Certified Meets CA (USA) Energy Commission Title 24 requirements Warranty 1 year Wireless Hallway Sensor Coverage Patterns Top View 150' 10' Side View 150' 7' 0 WLP150H Sensor Coverage Chart (Hallway) Width of Hall Length of Hall 6 ft. (1.0m) or less 50 ft. (15.2m) 8 ft. (2.4m) 100 ft. (30.5m) 10 ft. (3.0m) or more 150 ft. (45.7m) Note: Sensor mounting shown at 7 ft. (2.1m)Mounting height should be between 6 and 8 ft. (1.6 and 2.4m). Clear ConnectTM is a registered trademark of Lutron Electronics Co., Inc. www.hubbell-wiring.com (R) Wiring Device-Kellems E-27 H-MOSS(R) Controls Wiring Schematics WL-Series Wireless Sensors Wireless Wall Switch (WLS1278 Series) Single Location Installation WLS1278xx* Switch Blue - unused, tighten1 Brass Optional Hot/Live 120V AC 50/60 Hz or 277V AC 50/60 Hz Black Green Load LUT-MLC* Ground Neutral Note: *The included LUT-MLC ensures proper function when ffl luorescent, CFL, or LED loads are used. Install the LUT-MLC inside a load fixture or in a separate J-box of the circuit. 1 When using controls in single location installations, tighten the blue terminal without any wires attached. DO NOT connect the blue terminal to any other wiring or to ground. 2 Up to 9 Accessory Switches may be connected to the Wireless Switch. Total blue terminal wire length may be up to 250 ft. (76m). 3 Requires WLAS120 for 120V AC applications, and WLAS277 for 277V AC applications. Multi-Location Installation2 with WLAS1278xx or WLAS277xx3 WLAS Series Companion Switch Brass Blue WLAS Series Companion Switch Brass Blue WLS1278xx Switch Brass Blue Optional Hot/Live 120V AC 50/60 Hz or 277V AC 50/60 Hz Black Green Black Green Ground Black Ground Green Load LUT-MLC* Ground Neutral Clear ConnectTM is a registered trademark of Lutron Electronics Co., Inc. E-28 (R) Wiring Device-Kellems www.hubbell-wiring.com