Power Entry Module with RFI Power Line Filter for General
or Medical Applications
The L series power entry modules are compact units that
combine a multi-function power entry module and high per-
formance RFI filtering capabilities. They are available with
either a four-voltage selector or a DPST on/off switch. Both
variations can be specified with North American or
European fusing capabilities and are available in either
flange or snap-in mounting.
These filters are UL recognized, CSA certified, and VDE
approved. The L series modules offer a choice of filters for
general or medical applications.
EDL Models
The RFI filter is for general purpose applications where
line-to-line and line-to-ground noise must be controlled.
The filter is designed to meet the very low leakage
requirements of VDE portable equipment. They are
available in three current ratings.
EHL Models
This medical filter provides susceptibility protection
without the leakage current associated with line-to-ground
capacitors. Designed to allow equipment to meet UL544
for patient care and non-patient care equipment, the EHL
filter has a maximum leakage current of 2 µA at 120 VAC
60 Hz. See Appendix C for more information on medical
applications and UL standards.
Note: When using the models with an IEC connector,
remember that the leakage current of the companion line
cord, GA400, is more significant than that of the filter -
which may disqualify this line cord from use in patient care
applications.
118 Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
specified. Values in italics Specifications subject Germany: 49-89-6089-0
are metric equivalents. to change.
L Series
L Series
CORCOM Product Guide
UL Recognized
CSA Certified
VDE Approved
EDL1S/EHL1S
EDL4C/EHL4C
Voltage Selection
To change selected voltage: disconnect the power cord;
open cover using a small blade screwdriver or similar tool;
insert the tool into the voltage selection slot and remove
wheel from unit; select desired voltage; replace wheel into
unit and close cover, making sure the selected voltage
appears in connector window.
Voltage
selection
slot
4-Voltage
selection
wheel
Cover
Fuseholder
Note: All models have North American or dual European fusing capability
and are available in either flange or snap-in mounting.
119
Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
specified. Values in italics Specifications subject Germany: 49-89-6089-0
are metric equivalents. to change.
Power Entry Modules
LSeries
CORCOM Product Guide
Power Entry Module with RFI Power Line Filter for General
or Medical Applications (Continued)
Hot
Neutral Note 1 H
Ground
G
On/Off
2
(1) 1
(1a)
(2)
4(2a)
3
Note 2
Device
Cutomer
Transformer
Primaries
Electrical Schematics
DL Models (with switch)
Hot
Neutral
Note 1 G
Ground
H
On/Off
Note 2
Customer
Transformer
Primaries
100V
120V
100V
20V
120V
220V
240V
AA
BB
CC
DD
EE
FF
A
B
C
D
E
F
HL Models (with 4-voltage selection)
Hot
Neutral
Note 1 G
Ground
H
On/Off
Note 2
Cutomer
Transformer
Primaries
100V
120V
100V
20V
120V
220V
240V
AA
BB
CC
DD
EE
FF
A
B
C
D
E
F
DL Models (with 4-voltage selection)
Note 1: Provision for dual European style fusing.
Note 2: On/Off switch present only with "S" suffix.
Resistor location for reference only.
Hot
Neutral Note 1 H
Ground
G
On/Off
2
(1) 1
(1a)
(2)
4(2a)
3
Note 2
Device
Customer
Transformer
Primaries
HL Models (with switch)
Specifications
Maximum leakage current, each line-to-ground:
EDL EHL
Models Models
@120 VAC 60 Hz: 0.25 mA 2 µA
@250 VAC 50 Hz: 0.50 mA 5 µA
Hipot rating (one minute):
line-to-ground 1500 1500
line-to-line 1450 1450
Operating frequency: 50/60 Hz
Operating voltages:
1S & 1SC Suffix (fixed): 250 VAC Max.
4&4C Suffix (selectable): 100, 120, 220, 240 VAC
Rated current:
2EDL & 2EHL 2A
4EDL & 4EHL 4A
6EL, 6EDL & 6EHL 6A
Switch: Double-insulated, rated
for 10,000 operations at full
load. 51 Amp inrush capability.
Fuse (not included): Accepts one .25" x 1.25" fuse
or two 5 x 20 mm fuses
Terminals: 110 [2.79]except for switch
.187 [4.8]for switch
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current Frequency-MHz
Rating .05 .15 1 5 10 30
EDL Models
2A 6 14 24 40 45 50
4A 2 818 32 38 45
6A 1 6 17 31 37 45
EHL Models
06A 3 8 15 18 18 18
Line-to-line in 50 ohm circuit
Current Frequency-MHz
Rating .05 .5 1 3 5 10 30
EDL Models
2A 7 16 21 23 37 47 50
4A 6 14 18 23 26 45 47
6A 6 15 20 25 24 45 50
EHL Models
06A 4 14 20 28 32 38 42
Case Dimensions
ABCDEF
Part No. (max) ±.015 (max) (max) (max) (max)
±.381
Flange 1.98 1.575 2.3 2.14 1.66 1.11
Unfiltered 50.29 40.0 58.42 54.36 42.16 28.19
Snap-in 1.28 2.3 2.14 1.66 1.11
Unfiltered 32.51 58.42 54.36 42.16 28.19
Flange 1.98 1.575 2.3 2.14 2.01 1.11
Filtered 50.29 40.0 58.42 54.36 51.05 28.19
Snap-in 1.28 2.3 2.14 2.01 1.11
Filtered 32.51 58.42 54.36 51.05 28.19
120 Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
specified. Values in italics Specifications subject Germany: 49-89-6089-0
are metric equivalents. to change.
L Series
CORCOM Product Guide
Power Entry Module with RFI Power Line Filter for General
or Medical Applications (Continued)
Case Styles — Unfiltered Models
Flange Models
Typical dimensions:
Mounting Holes: .126 [3.20 ]Dia. (2)
All backplate terminals: .110 [2.79 ]terminals, except for switch.
Switch terminals are .187 [4.765 ]Note: Snap-in models allow front mounting only.
(1) For panel thickness of .031-.079 [0.8-2.0]
(2) For panel thickness of .083-.126 [2.1-3.2]
(3) For snap-in application, the 1.22 [28.5]sides of the cutout must have a .02 [.508]radius on
the installation side.
All backplate terminals: .110 [2.79]terminals, except for switch. Switch terminals are .187 [4.75]
Note: Snap-in models allow front mounting only.
GH
3
1
4
2
B
AE
.221
5.61
F
C D
.06
1.52R
2.201
55.91
2.213
56.21
1.122
28.50
1.575
40.00
.020
.508 R
*
*
*
*
+.008 -.00
+.203 -.00
Snap-In Models
ACE
BDF
A
GH
E
.221
5.61
F
C D
.06
1.52R
2.201
55.91
2.213
56.21
1.122
28.50
.020
.508 R
*
*
*
*
+.008 -.00
+.203 -.00
(1)
(2)
Back View
Side View
Back View
Recommended Panel Cutout
Recommended Panel Cutout
Side View
Snap-In Models
Case Styles — Filtered Models
ACE
BDF
GH
Snap-in version
D
E
.221
5.61
C
Side View
Side View
Note: Metric fuse models have additional jumper from filter-to-module.
Flange Models
121
Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
specified. Values in italics Specifications subject Germany: 49-89-6089-0
are metric equivalents. to change.
Power Entry Modules
LSeries
CORCOM Product Guide
Power Entry Module with RFI Power Line Filter for General
or Medical Applications (Continued)
UNFILTERED MODELS
Part Current Available Voltage DPST Mounting Fuseholder
Number Rating Selection On/Off Style Type
Position Switch
6EL1S 6A 1
Flange North American
6EL1SC 6A 1
Snap-In North American
6EL1SM 6A 1
Flange Metric
6EL1SCM 6A 1
Snap-In Metric
6EL4 6A 4 Flange North American
6EL4C 6A 4 Snap-In North American
6EL4M 6A 4 Flange Metric
6EL4CM 6A 4 Snap-in Metric
FILTERED MODELS
Part Filter Current Available Voltage DPST Mounting Fuseholder
Number Type Rating Selection On/Off Style Type
Position Switch
2EDL1S Linear 2A 1
Flange North American
2EDL1SC Linear 2A 1
Snap-In North American
2EDL1SM Linear 2A 1
Flange Metric
2EDL1SCM Linear 2A 1
Snap-In Metric
2EDL4 Linear 2A 4 Flange North American
2EDL4C Linear 2A 4 Snap-In North American
2EDL4M Linear 2A 4 Flange Metric
2EDL4CM Linear 2A 4 Snap-in Metric
4EDL1S Linear 4A 1
Flange North American
4EDL1SC Linear 4A 1
Snap-in North American
4EDL1SM Linear 4A 1
Flange Metric
4EDL1SCM Linear 4A 1
Snap-in Metric
4EDL4 Linear 4A 4 Flange North American
4EDL4C Linear 4A 4 Snap-in North American
4EDL4M Linear 4A 4 Flange Metric
4EDL4CM Linear 4A 4 Snap-in Metric
6EDL1S Linear 6A 1
Flange North American
6EDL1SC Linear 6 1
Flange North American
6EDL1SM Linear 6 1
Flange Metric
6EDL1SCM Linear 6 1
Snap-in Metric
6EDL4 Linear 6 4 Flange North American
6EDL4C Linear 6 4 Snap-in North American
6EDL4M Linear 6 4 Flange Metric
6EDL4CM Linear 6 4 Snap-in Metric
6EHL1S Medical 6 1
Flange North American
6EHL1SC Medical 61
Snap-in North American
6EHL1SM Medical 6 1
Flange Metric
6EHL1SCM Medical 6 1
Snap-in Metric
6EHL4 Medical 6 4 Flange North American
6EHL4C Medical 6 4 Snap-in North American
6EHL4M Medical 6 4 Flange Metric
6EHL4CM Medical 6 4 Snap-in Metric
Includes DPST switch