Power Protection and Conditioning
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© January 2017
48
The MCR provides excellent noise ltering and surge
protection to protect connected equipment from damage,
degradation or misoperation. Combined with the excellent
voltage regulation inherent to SolaHD’s ferroresonant design,
they can increase the actual Mean Time Between
Failure (MTBF) of protected equipment. These units are a
perfect choice where dirty power caused by impulses, swell,
sags, brownouts and waveform distortion can lead to costly
downtime because of damaged equipment.
Applications
Computers/ Printers
Telephone/FAX systems
POS terminals
Security systems
Laboratory equipment
LAN networks
Features
±3% output voltage regulation
Noise attenuation
- 120 dB common mode
- 60 dB transverse mode
Surge protection tested to ANSI/IEEE C62.41
Class A & B waveform (<10 V let-through typical)
Harmonic ltering
Galvanic isolation provides exceptional
circuit protection.
Point-of-use protection (cord & plug connected)
- Easy & Flexible Installation
25 year typical MTBF
No maintenance required
Certifications and Compliances
All Models
• RoHS Compliant
Listed
- UL 1012
Select Models
Listed (1500VA Units)
- UL 1012, CSA C22.2 No. 66
Certied (70VA-1kVA Units)
- CSA C22.2 No. 66
Related Products
DIN Rail AC UPS (SDU)
Off-Line UPS (S1K Mini-Tower)
Line-Interactive UPS (S3K Mini-Tower)
MCR Portable Series – Power Line Conditioning with Voltage Regulation
E47379
Selection Tables: Single Phase
Group A – MCR Portable Series, 60 Hz
VA Catalog
Number
Voltage
Input/Output
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Ship Weight
lbs (kg)
Receptacle (No.)
Type (NEMA)
Plug
(NEMA)
70 63-13-070-6 120 6.00 (152.4) 7.00 (177.8) 9.00 (228.6) 18.0 (8.16) (4) 5-15R 5-15P
150 63-13-115-6 120 6.00 (152.4) 7.00 (177.8) 9.00 (228.6) 21.0 (9.53) (4) 5-15R 5-15P
250 63-13-125-6 120 6.00 (152.4) 7.00 (177.8) 9.00 (228.6) 26.0 (11.79) (4) 5-15R 5-15P
500 63-13-150-6 120 9.00 (228.6) 9.00 (228.6) 16.00 (406.4) 32.0 (14.51) (4) 5-15R 5-15P
750 63-13-175-6 120 9.00 (228.6) 9.00 (228.6) 16.00 (406.4) 64.0 (29.03) (4) 5-15R 5-15P
1000 63-13-210-6 120 9.00 (228.6) 9.00 (228.6) 16.00 (406.4) 69.0 (31.30) (4) 5-15R 5-15P
1500* 63-13-215-6 120 11.00 (279.4) 11.00 (279.4) 17.00 (431.8) 95.0 (43.09) (6) 5-15R 5-20P
2000 63-13-220-6 120 11.00 (279.4) 11.00 (279.4) 17.00 (431.8) 115.0 (52.16) (4) 5-15R, (1) L5-30R L5-30P
3000* 63-13-230-6 120 11.00 (279.4) 11.00 (279.4) 17.00 (431.8) 143.0 (64.86) (4) 5-15R, (1) L5-30R 5-50P
*
* Only
LR044950
Power Protection and Conditioning
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© January 2017
49
Plug & Receptacle Reference Chart
5-15R
5-15P L5-30P
Back Panels
60 Hz, 2000–3000 VA,
(4) 5-15R and (1)
L5-30R Receptacle
60 Hz, 70 – 1000 VA,
(4) 5-15R Receptacles
Specifications
Parameter Condition Value
Input
Voltage Continuous at full load (lower input voltage possible at lighter load) +10% to -20% of nominal
For temporary surge or sags +20% to -35% of nominal
Current 1At Full Load & 80% of nominal input voltage Iin (VA/.89)/(Vin x 80%)
Frequency See Operating Characteristics section for details. 60 Hz depending on model
Output 1
Line Regulation Vin >80% and <110% of nominal ± 3% for 60 Hz units
Overload Protection At Nominal Input Voltage Current limited at 1.65 times rated current
Output Harmonic Distortion At full load within input range 3% total RMS content
Noise Attenuation -Common Mode
-Transverse Mode
120 dB
60 dB
Let-Through ANSI/IEEE C62.41 Class A & B Waveform <10V typical
General
Efficiency At Full Load 92% Typical
Storage Temperature Humidity <95% non-condensing -20° to +85°C
Operating Temperature Humidity <95% non-condensing -20° to 40°C
Audible Noise Full Resistive Noise 35 dBA to 65 dBA
Warranty 10 + 2 year limited warranty
Notes:
1 - It is recommended that the unit run at a minimum of 40-50% load.
Power Protection and Conditioning
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© January 2017
50
Model Comparison
BTU Output Chart for CVS and MCR Series
Note: Ratings are for a 40oC ambient temperature.
Description Hardwired CVS Hardwired MCR Portable MCR
VA Ratings 30 to 7500 VA 120 to 15000 VA 70 to 3000 VA
Input Voltage Range +10/-20% of nominal
Voltage Regulation ±1% for an input line variation of +10/-20%.
No loss of output for line loss of 3 msec.
±3% for an input line variation of +10/-20% (50 Hz hardwired units ±5%.)
No loss of output for complete line loss of 3 msec.
Overload Limits output current to 1.65 x rated current at nominal input.
Output Harmonic
Distortion 3% total RMS content at full load.
Noise Isolation 40 dB common and normal code. 120 dB common mode and 60 dB normal mode.
Surge Protection
Up to 6000 Volt surges are suppressed to a
let through of less than 1% per ANSI/IEEE
C62.41 Class A & B waveforms.
ANSI/IEEE C62.41 Class A & B 6000 waveforms are
suppressed to a let-through of less than 0.2%.
Efficiency Up to 92% at full load Up to 90% at full load
Operating
Temperature -20oC to 50oC -20oC to 40oC
Audible Noise 32 dB to 65 dB 35 dB to 65 dB 34 dB to 49 dB
Warranty 10 year limited warranty
VA Ratings 120 250 500 750 1000 1500 2000 3000 5000 7500 10000 15000
Total BTUs 136 225 280 444 519 686 1229 1331 2117 2407 3209 4813
Note: All values are typical and may vary based on VA ratings of actual units.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Sola/Hevi-Duty:
63-13-125-6 63-13-230-6 63-13-215-6 63-13-150-6 63-13-175-6 63-13-070-6 63-13-210-6 63-13-115-6 63-13-
220-6