Analog and Discrete Outputs D10 Expert Fiber-Optic Sensor
page 3
Banner Engineering Corp. • Minneapolis MN, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Programming Options
Response
Range
Light/Dark Operate
Selection Toggle to select the condition for which each output will conduct: when the target is present or when the target is absent.
OFF-Delay Timing
Selection
Programmable OFF-delay pulse stretcher: 0, 2, 5, 10, 15, 20, 30, 40, 60, 80, or 100 milliseconds
Analog Outputs: Off-delay acts as a smoothing function
Display Selection Discrete Output: Raw signal value or % excess signal
Analog Output: Raw signal value or analog value (0-10V dc or 4-20 mA)
Power Level/Speed
Selection
Tracking Feature Sets Output 2 to identical settings as Output 1; Output 2 settings can then be revised as desired. (See Advanced Setup procedure,
page 11.)
Factory Default Settings
The following settings are preset at the factory; revert sensor to factory defaults using Advanced Setup procedure (page 8).
• Light operate (lo) • Output 1 displayed • Analog: full scale
• No OFF delay (t 0) • High Speed (HS); 200 µs response • Discrete: switch-point positioned
• Raw signal value (1234) • Maximum power setting at middle of range
Super High-Power
SHP
High-Power
HP
High-Speed
HS
25 µs 100 µs75 µs50 µs
50 µs 2.5 ms1 ms200 µs
Super High-Speed
SHS
9 mm 16 mm13 mm9 mm
6 mm 30 mm18 mm10 mm
100 mm 300 mm250 mm175 mm
20 mm 90 mm55 mm30 mm
1200 mm1000 mm550 mm
30 mm 150 mm100 mm50 mm
175 mm 475 mm400 mm250 mm
Maximum Range*
FiberColor
PIT16U
680 nm Red
100 mm 400 mm250 mm150 mm
2400 mm1700 mm1000 mm
PIT16U
PBT66U
PBT46U
PBT26U
PBT16U
PIT66U
PIT46U
PIT26U
525 nm Green
600 mm
300 mm
** 3.5 mm3 mm**
PBT16U
PIT66U
PIT46U
PIT26U
180 mm
100 mm
40 mm
180 mm
100 mm
40 mm
280 mm
160 mm
55 mm
320 mm
180 mm
70 mm
30 mm 60 mm42 mm30 mmPBT46U
12 mm 25 mm20 mm12 mmPBT26U
55 mm 100 mm80 mm55 mmPBT66U
D10 Programming
Programming Procedures
Two push buttons, Dynamic (+) and Static (-), may be used to access and set
programming parameters. For remote programming, connect a switch or digital input to
the gray wire; length of the individual pulses is equal to the value T:
0.04 seconds ≤T ≤0.8 seconds
Returning to RUN Mode
TEACH and SETUP modes each may be exited in one of two ways: by exercising the 60-
second time-out, or by cancelling out of the process. In TEACH mode, the sensor will
return to RUN mode without saving any of the new settings; in SETUP mode, the sensor
will return to RUN mode but save all of the settings. To cancel out of TEACH mode,
press and hold the Static (-) button for 2 seconds; to cancel out of SETUP mode, press
and hold both the Static (-) and Dynamic (+) buttons for 2 seconds.
Output 2
The set-point(s) for each output can be set independently of one another. However, the
functional range available for output 2 is dictated by the automatic power and gain
settings established for output 1. Whenever output 1 is taught, output 2 also must be
retaught. Applications hint: teach the weakest signal on output 1 first.
*Diffuse mode performance based on 90%
reflectance white test card.
** ø0.010" bifurcated fiber not recommended in
these speed settings. Contact Banner
Applications for more information.
Discrete Response
Repeatability