150WSingleOutputwithPFCFunction ASP-150 series
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
High power density 8.4w/in
100% full load burn-in test
No load power consumption<1W@240VAC
ZCS/ZVS technology to reduce power dissipation
3 years warranty
3
Features :
SPECIFICATION
OVERTEMPERATURE 90 10 (RTH2)detectonheatsinkofpowertransistor
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
Fixed.Canbemodifiedbetweentherangeabovebyfactory
ASP-150-12 ASP-150-15 ASP-150-20 ASP-150-24 ASP-150-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
WORKINGHUMIDITY
WORKINGTEMP.
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
12V 15V 20V 24V 48V
11A 9.5A 7.5A 6.3A
0~6.3A
151.2W
3.2A
0~11A 0~9.5A 0~7.5A 0~3.2A
132W 142.5W 150W 153.6W
150mVp-p 180mVp-p 200mVp-p 240mVp-p 240mVp-p
11~13.2V 14~17V 17~22V 22~27V 45.6~52.8V
2.0% 2.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.5%
0.5%1.0%
0.5% 0.5%
0.5%1.0% 0.5%
3000ms,80msatfullload
50ms/230VAC 16ms/115VACatfullload
90~264VAC127~370VDC
47~63Hz
PF 0.95/230VACPF 0.98/115VAC atfullload
88% 88% 90%
17.5~20.25V 22.5~28V
90%
27.5~32.4V
89%
53.3~64.8V
2A/115VAC1A/230VAC
COLDSTART 80A/230VAC
<2mA /240VAC
105~135% ratedoutputpower
13.7~16.2V
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
20~90%RHnon-condensing
-20~+60 (Refertooutputloadderatingcurve)
-20~+85 ,10~95%RH
0.05%/ (0~50
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes
149.3Khrsmin.MIL-HDBK-217F(25 )
169*60.7*28.5mm(L*W*H)
0.32Kg;48pcs/15.8Kg/0.79CUFT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
UL60950-1,CB(IEC60950-1)approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,lightindustrylevel,criteria A
EMICONDUCTION&RADIATION
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:4.25KVDCI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Heat Sink HS1,HS3 & HS2,HS3 can not be shorted.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
FileName:ASP-150-SPEC2010-10-18
http://store.iiic.cc/