AXICOM Telecom-, Signal and RF Relays Cradle Relay N V23154 / V23162 108-98012 * Nov. 07 * Rev. C * ECOC: JM10 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco Electronics expressly disclaims all implied warranties (and all express warranties, except as otherwise stated in this datasheet) regarding the information contained herein, including but not limited to any implied warranties or merchantability or fitness for a particular purpose. It is recommended that you test any new or replacement product before incorporating into a system. The dimensions in this datasheet are for reference purpose only and are subject to change without notice. Specifications are subject to change without notice. Index Dimensions Coil Data and operating range Relay Code Coil Data and Ordering Information Instructions for Impulse Operation Nomograph for Determining Factor q Contact Data Insulation / General Data All specifications subject to change. Consult Tyco Electronics for latest specifications. 4 6 7 9 17 18 19 21 2 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 PCB, hand solder or plug-in relays, for DC operation, non-polarized, non-latching ROHS compliant (Directive 2002/95/EC) as per product date code 0501. Features * Multi purpose relay * highly reliable * great variety of contact arrangements and materials to meet specific applications * Contacts for signal loads and currents up to 5 A * AC and DC, latching and non-latching, coils operating voltage 1.5 V ... 125 V * Sockets for easy and quick mounting of relays (see data sheet Accessories) Typical applications * Measurement and control equipment * Press controls with high safety requirements (forcibly guided springs) * Telecommunications Relay types * Size I or II, depending on contact set * Standard contact sets with max. 4 changeover, 2 break or 6 make contacts, special configurations on request * Single or bifurcated contacts * Hand solder terminals also for plug-in connection with screw fixing or PCB terminals * Dust-protected with plastic cover, V23154 - xxx hermetically sealed with metal enclosure, V23162 - xxx All specifications subject to change. Consult Tyco Electronics for latest specifications. 3 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Dimensions Type V23154-C0xx Size I Dimensions in mm Type V23154-D0xx Size II Hand solder terminals, silver-plated Also for plug-in connection and screw fixing With earth terminal Dust-protected Type V23154-MXX Size I Type V23154-NXX Size II For printed circuit mounting With or without earth terminal Dust-protected For sockets and hold-down springs see data sheet Accessories All specifications subject to change. Consult Tyco Electronics for latest specifications. 4 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Dimensions Type V23162-A0xx Size I Dimensions in mm Type V23162-B0xx Size II / V23162-H0xx Size II Hand solder terminals, silver or gold plated Also for plug-in connection and screw fixing Hermetically sealed For sockets and hold-down springs see data sheet Accessories Mounting hole layout for V23154 - M/Nxx View onto the component side of the PCB (top view) M = Earth terminal a) Hole for mechanical armature actuation, if required b) Hole for socket mounting with screw M1.6. All specifications subject to change. Consult Tyco Electronics for latest specifications. 5 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Coil Data and operating range Nominal voltage from 5 Vdc to 125 Vdc Typical nominal power consumption, at 20 C Class of the operative range acc to EN 61810-1 / IEC 61810-1 and VDE 0435 Part 201 Operating voltage (according to the coil type) 0.8 W 2 max. 98% of the nominal voltage Terminals: Coil with 1 winding Start 4 End 1 Coil with 2 windings (upon request) Start 3 End 2 for winding I Start 4 End 1 for winding II The minimum voltage UI depends on the contact set and the ambient temperature, the maximum voltage UII only depends on the ambient temperature. Between minimum voltage UI tamb and operating voltage U a safety margin of approx. 20% is recommended. UI tamb (1.2) < UI UII tamb UI tamb = UI * U20 C * kI tamb UII tamb = UIl 20 C * kII tamb tamb = Ambient temperature U = Operating voltage UI tamb = Minimum voltage at ambient temperature, tamb UII tamb = Maximum voltage at ambient temperature, tamb kI and kII = Factors All specifications subject to change. Consult Tyco Electronics for latest specifications. 6 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Relay Code V 2 3 1 5 4 Identification of the Cradle N Relay, dust protected Relay type C0 = D0 = M0 = N0 = M4 = N4 = Size I, for plug-in and screw fixing, hand solder terminals silver-plated, with earth terminal, dust-protected Size II, for plug-in and screw fixing, hand solder terminals silver-plated, with earth terminal, dust-protected Size I, for printed circuit mounting, with earth terminal, dust-protected Size II, for printed circuit mounting, with earth terminal, dust-protected Size I, for printed circuit mounting, without earth terminal, dust-protected Size II, Coil number Monostable, 1 coil 711 = 5 V nominal voltage 712 = 6V 717 = 12 V 721 = 24 V 726 = 48 V 734 = 60 V 735 = 110 V 703 = 125 V Contact set / type of contact see page 19 Ordering example: V23154-D0721-B110 Cradle relay N, size II, plug-in, dust-protected, hand solder terminals, silver-plated, coil 24 Vdc, 4 changeover contact set, single contacts, contact material silver, gold-flashed. Note: The ordering scheme enables a multitude of variations. However, not all variations are defined as construction specifications (ordering code) and thus in the current delivery program. All specifications subject to change. Consult Tyco Electronics for latest specifications. 7 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Relay Code V 2 3 1 6 2 Identification of the Cradle N Relay, hermetically sealed Relay type A0 = B0 = H0 = Size I, for plug-in and screw fixing, hand solder terminals tinned, hermetically sealed Size II, for plug-in and screw fixing, hand solder terminals tinned, hermetically sealed Size II, for plug-in and screw, fixing, hand solder terminals, gold-plated Coil number Monostable, 1 coil 711 = 5 V nominal voltage 712 = 6V 717 = 12 V 721 = 24 V 726 = 48 V 734 = 60 V 735 = 110 V 703 = 125 V Contact set / type of contact see page 19 Ordering example: V23162-A0721-B104 Cradle relay N, size I, plug-in, hemeticaly sealed, hand solder terminals, silver-plated, coil 24 Vdc, 2 changeover contact set, single contacts, contact material silver, gold-flashed. Note: The ordering scheme enables a multitude of variations. However, not all variations are defined as construction specifications (ordering code) and thus in the current delivery program. All specifications subject to change. Consult Tyco Electronics for latest specifications. 8 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Coil Data (values at 20 C) Nominal Voltage Unom Vdc Operating voltage range Minimum Voltage Umin Vdc V23154-C0XX standard, size I 5.00 1.80 5.00 1.80 7.00 2.70 7.00 2.70 10.00 7.10 12.00 6.60 12.00 5.30 12.00 7.10 15.00 6.80 15.00 6.80 15.00 9.10 15.00 9.10 20.00 8.90 20.00 8.90 20.00 8.90 20.00 8.90 20.00 11.90 24.00 11.20 24.00 11.00 24.00 11.00 24.00 14.50 24.00 14.50 25.00 20.80 32.00 16.90 32.00 16.90 32.00 16.90 32.00 22.60 32.00 22.60 32.00 22.60 48.00 23.00 48.00 23.00 48.00 23.00 48.00 30.00 48.00 30.00 60.00 27.00 72.00 36.00 72.00 36.20 72.00 36.20 72.00 36.20 72.00 36.20 72.00 36.20 72.00 48.40 72.00 48.40 110.00 49.00 125.00 61.00 125.00 81.00 125.00 81.00 V23154-C0XX 5A, size I 1.10 1.10 7.00 7.00 0.40 0.40 2.70 2.70 Ordering Information Coil power mW Coil Resistance 15% Relay code Tycp part number 7.20 7.20 10.50 10.50 16.00 20.50 20.00 20.00 24.50 24.50 24.50 24.50 32.00 32.00 32.00 32.00 32.00 36.00 40.00 40.00 40.00 40.00 36.30 54.00 54.00 54.00 54.00 54.00 54.00 75.00 75.00 75.00 75.00 75.00 92.00 100.00 114.00 114.00 114.00 114.00 114.00 114.00 114.00 164.00 190.00 190.00 190.00 893 893 845 845 714 626 655 655 692 692 692 692 727 727 727 727 727 823 647 647 647 647 856 602 602 602 602 602 602 720 720 720 720 720 766 894 682 682 682 682 682 682 682 807 748 748 748 28 28 58 58 140 230 220 220 325 325 325 325 550 550 550 550 550 700 890 890 890 890 730 1700 1700 1700 1700 1700 1700 3200 3200 3200 3200 3200 4700 5800 7600 7600 7600 7600 7600 7600 7600 15000 20900 20900 20900 V23154C711B104 V23154C711B604 V23154C712B104 V23154C712B604 V23154C430B104 V23154C418B104 V23154C717B104 V23154C717C104 V23154C719B104 V23154C719B604 V23154C719C104 V23154C719C404 V23154C720B101 V23154C720B103 V23154C720B104 V23154C720B604 V23154C720C104 V23154C421B104 V23154C721B104 V23154C721B604 V23154C721C104 V23154C721C404 V23154C496C104 V23154C722B101 V23154C722B104 V23154C722B604 V23154C722C104 V23154C722C404 V23154C722C604 V23154C726B101 V23154C726B104 V23154C726B604 V23154C726C104 V23154C726C404 V23154C734B104 V23154C404B104 V23154C704B101 V23154C704B102 V23154C704B104 V23154C704B108 V23154C704B604 V23154C704C104 V23154C704C404 V23154C735B104 V23154C703B104 V23154C703C101 V23154C703C403 5-1393806-3 5-1393806-4 5-1393806-5 5-1393806-6 2-1393806-0 1393806-8 6-1393806-7 6-1393806-8 7-1393806-1 7-1393806-2 7-1393806-3 7-1393806-4 7-1393806-6 7-1393806-7 7-1393806-8 7-1393806-9 8-1393806-1 1-1393806-1 8-1393806-6 8-1393806-7 8-1393806-8 8-1393806-9 2-1393806-5 9-1393806-3 9-1393806-4 9-1393806-5 9-1393806-7 9-1393806-8 9-1393806-9 1393807-5 1393807-6 1393807-7 1393807-8 1393807-9 1-1393807-4 1393806-2 4-1393806-1 4-1393806-2 4-1393806-3 4-1393806-4 4-1393806-5 4-1393806-6 4-1393806-7 1-1393807-6 3-1393806-6 3-1393806-7 3-1393806-8 1.70 1.70 10.50 10.50 807 807 845 845 1.5 1.5 58 58 V23154C702F101 V23154C702F106 V23154C712F105 V23154C712F106 3-1393806-3 3-1393806-4 5-1393806-7 5-1393806-8 Maximum voltage Umax Vdc All specifications subject to change. Consult Tyco Electronics for latest specifications. 9 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Coil Data (values at 20 C) Nominal Voltage Unom Vdc Operating voltage range Minimum Voltage Umin Vdc V23154-C0XX 5A, size I 9.00 12.00 12.00 14.50 19.00 19.00 24.00 24.00 24.00 33.00 33.00 33.00 48.00 48.00 60.00 72.00 72.00 110.00 125.00 Maximum voltage Umax Vdc Ordering Information Coil power mW Coil Resistance 15% Relay code Tycp part number 3.90 7.10 7.10 6.60 8.20 8.20 15.00 11.00 11.00 16.00 16.00 16.00 23.00 30.00 27.00 36.20 36.20 49.00 61.00 14.00 20.00 20.00 24.00 31.00 31.00 36.00 40.00 40.00 54.00 54.00 54.00 75.00 75.00 92.00 114.00 114.00 164.00 190.00 736 655 655 647 681 681 823 647 647 641 641 641 720 720 766 682 682 807 748 110 220 220 325 530 530 700 890 890 1700 1700 1700 3200 3200 4700 7600 7600 15000 20900 V23154C715F105 V23154C717F105 V23154C717F106 V23154C719F105 V23154C720F105 V23154C720F106 V23154C421F105 V23154C721F105 V23154C721F106 V23154C722F101 V23154C722F105 V23154C722F106 V23154C726F105 V23154C726F106 V23154C734F106 V23154C704F105 V23154C704F106 V23154C735F106 V23154C703F106 6-1393806-3 6-1393806-9 7-1393806-0 7-1393806-5 8-1393806-2 8-1393806-3 1-1393806-3 9-1393806-1 9-1393806-2 1393807-1 1393807-2 1393807-3 1-1393807-1 1-1393807-2 1-1393807-5 4-1393806-8 1413000-2 1-1393807-7 4-1393806-0 V23154-D0XX standard, size II 5.00 2.50 5.00 2.50 5.00 3.00 5.00 3.00 7.00 3.60 7.00 3.60 7.00 4.40 8.50 4.80 8.50 4.80 8.50 5.80 10.00 5.80 10.00 5.80 10.00 5.80 10.00 7.10 12.00 8.80 12.00 7.10 12.00 7.10 12.00 7.10 12.00 7.10 12.00 7.10 12.00 10.50 15.00 9.10 15.00 9.10 15.00 9.10 15.00 9.10 15.00 9.10 15.00 9.10 15.00 11.00 16.00 15.20 16.00 15.20 16.00 15.20 16.00 15.20 7.20 7.20 7.20 7.20 10.50 10.50 10.50 14.00 14.00 14.00 16.50 16.50 16.50 16.50 20.50 20.00 20.00 20.00 20.00 20.00 20.00 24.50 24.50 24.50 24.50 24.50 24.50 24.50 27.00 27.00 27.00 27.00 893 893 893 893 845 845 845 657 657 657 667 667 667 667 626 655 655 655 655 655 655 692 692 692 692 692 692 692 656 656 656 656 28 28 28 28 58 58 58 110 110 110 150 150 150 150 230 220 220 220 220 220 220 325 325 325 325 325 325 325 390 390 390 390 V23154D711B110 V23154D711B628 V23154D711C110 V23154D711C410 V23154D712B110 V23154D712B610 V23154D712C110 V23154D715B110 V23154D715B610 V23154D715C110 V23154D716B110 V23154D716B117 V23154D716B610 V23154D716C110 V23154D418B110 V23154D717B110 V23154D717B112 V23154D717B124 V23154D717B529 V23154D717B610 V23154D717C110 V23154D719B110 V23154D719B112 V23154D719B117 V23154D719B124 V23154D719B210 V23154D719B610 V23154D719C110 V23154D479B110 V23154D479B111 V23154D479B117 V23154D479B128 2-1393808-8 2-1393808-9 3-1393808-0 3-1393808-1 3-1393808-3 3-1393808-4 3-1393808-5 3-1393808-8 3-1393808-9 4-1393808-0 4-1393808-3 8-1422029-0 4-1393808-5 4-1393808-6 3-1393807-0 4-1393808-9 5-1393808-0 5-1393808-1 5-1393808-2 8-1422029-2 5-1393808-3 5-1393808-6 5-1393808-7 5-1393808-8 5-1393808-9 6-1393808-0 6-1393808-1 1413000-3 7-1393807-5 7-1393807-6 1422029-6 7-1393807-7 All specifications subject to change. Consult Tyco Electronics for latest specifications. 10 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Coil Data (values at 20 C) Nominal Voltage Unom Vdc Operating voltage range Minimum Voltage Umin Vdc V23154-D0XX standard, size II 16.00 18.90 20.00 11.90 20.00 11.90 20.00 11.90 20.00 11.90 20.00 11.90 20.00 14.40 20.00 14.40 20.00 14.40 20.00 14.40 20.00 14.40 24.00 15.00 24.00 15.00 24.00 15.00 24.00 15.00 24.00 18.20 24.00 18.20 24.00 14.50 24.00 14.50 24.00 14.50 24.00 14.50 24.00 14.50 24.00 14.50 24.00 14.50 24.00 14.50 24.00 14.50 24.00 14.50 24.00 14.50 24.00 22.00 24.00 18.00 24.00 18.00 24.00 18.00 24.00 18.00 25.00 20.80 25.00 20.80 32.00 22.60 32.00 22.60 32.00 22.60 32.00 22.60 32.00 22.60 32.00 22.60 32.00 22.60 32.00 22.60 32.00 22.60 32.00 22.60 32.00 33.80 32.00 33.80 48.00 30.00 48.00 30.00 48.00 30.00 48.00 30.00 48.00 30.00 48.00 30.00 Maximum voltage Umax Vdc 27.00 32.00 32.00 32.00 32.00 32.00 32.00 32.00 32.00 32.00 32.00 36.00 36.00 36.00 36.00 36.00 36.00 40.00 40.00 40.00 40.00 40.00 40.00 40.00 40.00 40.00 40.00 40.00 40.00 40.00 40.00 40.00 40.00 36.30 36.30 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 75.00 75.00 75.00 75.00 75.00 75.00 Ordering Information Coil power mW 656 727 727 727 727 727 727 727 727 727 727 823 823 823 823 823 823 647 647 647 647 647 647 647 647 647 647 647 647 647 647 647 647 856 856 602 602 602 602 602 602 602 602 602 602 602 602 720 720 720 720 720 720 All specifications subject to change. Consult Tyco Electronics for latest specifications. Coil Resistance 15% 390 550 550 550 550 550 550 550 550 550 550 700 700 700 700 700 700 890 890 890 890 890 890 890 890 890 890 890 890 890 890 890 890 730 730 1700 1700 1700 1700 1700 1700 1700 1700 1700 1700 1700 1700 3200 3200 3200 3200 3200 3200 Relay code Tycp part number V23154D479C110 V23154D720B110 V23154D720B112 V23154D720B116 V23154D720B117 V23154D720B610 V23154D720C110 V23154D720C112 V23154D720C410 V23154D720C412 V23154D720C610 V23154D421B110 V23154D421B117 V23154D421B124 V23154D421B612 V23154D421C110 V23154D421C410 V23154D721B110 V23154D721B112 V23154D721B114 V23154D721B116 V23154D721B117 V23154D721B124 V23154D721B129 V23154D721B142 V23154D721B510 V23154D721B610 V23154D721B612 V23154D721C110 V23154D721C112 V23154D721C114 V23154D721C117 V23154D721C410 V23154D496B110 V23154D496B112 V23154D722B110 V23154D722B112 V23154D722B113 V23154D722B114 V23154D722B116 V23154D722B117 V23154D722B124 V23154D722B129 V23154D722B129 V23154D722B610 V23154D722C110 V23154D722C410 V23154D726B110 V23154D726B112 V23154D726B117 V23154D726B124 V23154D726B129 V23154D726B610 7-1393807-8 6-1393808-5 6-1393808-6 6-1393808-7 6-1393808-8 6-1393808-9 7-1393808-0 7-1393808-1 7-1393808-3 7-1393808-4 7-1393808-5 3-1393807-7 3-1393807-9 4-1393807-0 4-1393807-1 4-1393807-2 4-1393807-3 8-1393808-3 8-1393808-4 8-1393808-5 8-1393808-6 8-1393808-7 8-1393808-8 8-1393808-9 9-1393808-0 9-1393808-1 9-1393808-2 9-1393808-3 9-1393808-5 9-1393808-6 9-1393808-7 9-1393808-8 9-1393808-9 8-1393807-2 8-1393807-3 1-1393809-4 1-1393809-5 1-1393809-6 1-1393809-7 1-1393809-8 1-1393809-9 2-1393809-0 1413000-1 1419138-9 2-1393809-1 2-1393809-2 2-1393809-3 3-1393809-2 3-1393809-4 3-1393809-5 3-1393809-6 3-1393809-7 3-1393809-8 11 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Coil Data (values at 20 C) Nominal Voltage Unom Vdc Operating voltage range Minimum Voltage Umin Vdc Maximum voltage Umax Vdc Ordering Information Coil power mW Coil Resistance 15% Relay code Tycp part number V23154-D0XX standard, size II 48.00 45.00 48.00 37.00 48.00 37.00 48.00 37.00 60.00 36.00 60.00 36.00 60.00 43.00 72.00 48.00 72.00 48.00 72.00 48.00 72.00 48.00 72.00 48.40 72.00 48.40 72.00 48.40 72.00 48.40 72.00 48.40 72.00 48.40 72.00 48.40 72.00 48.40 72.00 58.70 72.00 58.70 72.00 58.70 110.00 65.00 110.00 65.00 110.00 65.00 125.00 81.00 125.00 81.00 75.00 75.00 75.00 75.00 92.00 92.00 92.00 100.00 100.00 100.00 100.00 114.00 114.00 114.00 114.00 114.00 114.00 114.00 114.00 114.00 114.00 114.00 164.00 164.00 164.00 190.00 190.00 720 720 720 720 766 766 766 894 894 894 894 682 682 682 682 682 682 682 682 682 682 682 807 807 807 748 748 3200 3200 3200 3200 4700 4700 4700 5800 5800 5800 5800 7600 7600 7600 7600 7600 7600 7600 7600 7600 7600 7600 15000 15000 15000 20900 20900 V23154D726C110 V23154D726C112 V23154D726C117 V23154D726C410 V23154D734B110 V23154D734B610 V23154D734C410 V23154D404B110 V23154D404B112 V23154D404B117 V23154D404B610 V23154D704B110 V23154D704B112 V23154D704B114 V23154D704B116 V23154D704B117 V23154D704B119 V23154D704B121 V23154D704B210 V23154D704C110 V23154D704C112 V23154D704C113 V23154D735B110 V23154D735B117 V23154D735B610 V23154D703B110 V23154D703B117 3-1393809-9 4-1393809-0 4-1393809-1 4-1393809-2 5-1393809-6 5-1393809-7 5-1393809-8 1-1393807-8 1-1393807-9 2-1393807-0 2-1393807-1 1393808-6 1393808-8 1393808-9 1-1393808-0 1-1393808-1 1-1393808-2 1-1393808-3 1-1393808-4 1-1393808-6 1-1393808-7 1-1393808-8 6-1393809-2 6-1393809-3 6-1393809-4 1393808-1 1393808-3 V23154-D0XX 5A , size II 5.00 1.80 7.00 3.60 12.00 6.60 12.00 7.10 15.00 6.80 20.00 11.90 20.00 8.90 24.00 15.00 24.00 11.00 24.00 14.50 32.00 22.60 48.00 30.00 60.00 27.00 72.00 36.00 72.00 48.40 110.00 65.00 125.00 81.00 7.20 10.50 20.50 20.00 24.50 32.00 32.00 36.00 40.00 40.00 54.00 75.00 92.00 100.00 114.00 164.00 190.00 893 845 626 655 692 727 727 823 647 647 602 720 766 894 682 807 748 28 58 230 220 325 550 550 700 890 890 1700 3200 4700 5800 7600 15000 20900 V23154D711F104 V23154C712B104 V23154D418F104 V23154D717F104 V23154D719F104 V23154D720F104 V23154D720F304 V23154D421F104 V23154D721F104 V23154D721F304 V23154D722F104 V23154D726F104 V23154D734F104 V23154D404F104 V23154D704F104 V23154D735F104 V23154D703F104 3-1393808-2 3-1393808-6 3-1393807-1 5-1393808-4 6-1393808-2 7-1393808-6 7-1393808-7 4-1393807-4 1393809-1 1393809-2 2-1393809-4 4-1393809-4 6-1393809-0 2-1393807-2 1-1393808-9 6-1393809-5 1393808-4 V23154-M0XX standard, size I 7.00 2.70 12.00 5.30 12.00 7.10 15.00 6.80 15.00 9.10 10.50 20.00 20.00 24.50 24.50 845 655 655 692 692 58 220 220 325 325 V23154M712B104 V23154M717B104 V23154M717C104 V23154M719B104 V23154M719C104 1-1393810-8 2-1393810-1 2-1393810-2 2-1393810-3 2-1393810-4 All specifications subject to change. Consult Tyco Electronics for latest specifications. 12 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Coil Data (values at 20 C) Nominal Voltage Unom Vdc Operating voltage range Minimum Voltage Umin Vdc Maximum voltage Umax Vdc Ordering Information Coil power mW Coil Resistance 15% Relay code Tycp part number V23154-M0XX standard, size I 20.00 8.90 20.00 8.90 24.00 11.00 24.00 11.00 24.00 14.50 32.00 16.90 32.00 16.90 33.00 22.60 33.00 22.60 48.00 23.00 48.00 30.00 72.00 36.20 125.00 61.00 32.00 32.00 40.00 40.00 40.00 54.00 54.00 54.00 54.00 75.00 75.00 114.00 190.00 727 727 647 647 647 602 602 641 641 720 720 682 748 550 550 890 890 890 1700 1700 1700 1700 3200 3200 7600 20900 V23154M720B104 V23154M720B604 V23154M721B104 V23154M721B604 V23154M721C104 V23154M722B104 V23154M722B604 V23154M722C104 V23154M722C404 V23154M726B104 V23154M726C104 V23154M704B104 V23154M703B104 2-1393810-5 2-1393810-6 2-1393810-7 2-1393810-9 3-1393810-0 3-1393810-4 3-1393810-5 2-1419172-5 3-1393810-6 3-1393810-8 4-1393810-0 1-1393810-5 1-1393810-4 V23154-M0XX 5A, size I 7.00 2.70 19.00 8.20 24.00 11.00 24.00 11.00 24.00 11.00 33.00 16.00 48.00 23.00 72.00 36.20 10.50 31.00 40.00 40.00 40.00 54.00 75.00 114.00 845 681 647 647 647 641 720 682 58 530 890 890 890 1700 3200 7600 V23154M712F101 V23154M720F105 V23154M721F101 V23154M721F105 V23154M721F106 V23154M722F106 V23154M726F106 V23154M704F101 1-1393810-9 2-1422030-5 3-1393810-1 3-1393810-2 3-1393810-3 3-1393810-7 4-1393810-1 1-1393810-6 V23154-M4XX standard, size I 12.00 7.10 15.00 9.10 24.00 14.50 20.00 24.50 40.00 655 692 647 220 325 890 V23154M4717C104 V23154M4719C104 V23154M4721C104 4-1393810-5 4-1393810-6 4-1393810-7 V23154-M4XX 5A, size I 24.00 11.00 40.00 647 890 V23154M4721F106 2-1422030-4 V23154-N0XX standard, size II 7.00 3.60 10.00 7.10 12.00 7.10 12.00 10.50 15.00 9.10 20.00 11.90 20.00 11.90 20.00 17.70 20.00 14.40 20.00 17.70 24.00 14.50 24.00 14.50 24.00 14.50 24.00 22.00 24.00 22.00 32.00 22.60 32.00 33.80 32.00 27.40 48.00 30.00 48.00 45.00 10.50 16.50 20.00 20.00 24.50 32.00 32.00 32.00 32.00 32.00 40.00 40.00 40.00 40.00 40.00 54.00 54.00 54.00 75.00 75.00 845 667 655 655 692 727 727 727 727 727 647 647 647 647 647 602 602 602 720 720 58 150 220 220 325 550 550 550 550 550 890 890 890 890 890 1700 1700 1700 3200 3200 V23154N712B110 V23154N716C110 V23154N717B110 V23154N717C414 V23154N719B110 V23154N720B110 V23154N720B610 V23154N720C110 V23154N720C112 V23154N720C410 V23154N721B110 V23154N721B112 V23154N721B610 V23154N721C110 V23154N721C114 V23154N722B110 V23154N722C110 V23154N722C112 V23154N726B110 V23154N726C110 5-1393810-4 5-1393810-8 5-1393810-9 6-1393810-0 6-1393810-3 6-1393810-4 6-1393810-5 6-1393810-6 6-1393810-7 6-1393810-8 7-1393810-0 7-1393810-1 7-1393810-2 7-1393810-3 7-1393810-4 7-1393810-6 7-1393810-7 7-1393810-8 8-1393810-0 8-1393810-2 All specifications subject to change. Consult Tyco Electronics for latest specifications. 13 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Coil Data (values at 20 C) Nominal Voltage Unom Vdc 48.00 48.00 48.00 48.00 60.00 72.00 72.00 72.00 Operating voltage range Minimum Voltage Umin Vdc Maximum voltage Umax Vdc Ordering Information Coil power mW Coil Resistance 15% Relay code Tycp part number 37.00 37.00 45.00 45.00 36.00 48.00 58.70 58.70 75.00 75.00 75.00 75.00 92.00 100.00 114.00 114.00 720 720 720 720 766 894 682 682 3200 3200 3200 3200 4700 5800 7600 7600 V23154N726C117 V23154N726C119 V23154N726C121 V23154N726C124 V23154N734B110 V23154N404B110 V23154N704C114 V23154N704C121 8-1393810-3 8-1393810-4 8-1393810-5 8-1393810-6 8-1393810-9 4-1393810-8 5-1393810-2 5-1393810-3 V23154-N0XX 5A, size II 12.00 5.30 20.00 8.90 24.00 11.00 32.00 16.90 48.00 23.00 60.00 27.00 72.00 36.20 125.00 61.00 20.00 32.00 40.00 54.00 75.00 92.00 114.00 190.00 655 727 647 602 720 766 682 748 220 550 890 1700 3200 4700 7600 20900 V23154N717F104 V23154N720F104 V23154N721F104 V23154N722F104 V23154N726F104 V23154N734F104 V23154N704F104 V23154N703F104 6-1393810-1 6-1393810-9 7-1393810-5 7-1393810-9 8-1393810-7 9-1393810-0 1422030-1 5-1393810-1 V23154-N4XX standard, size II 10.00 9.00 20.00 11.90 24.00 22.00 48.00 30.00 60.00 36.00 16.50 32.00 40.00 75.00 92.00 667 727 647 720 766 150 550 890 3200 4700 V23154N4716C110 V23154N4720B110 V23154N4721C110 V23154N4726B110 V23154N4734B110 1393811-1 1393811-2 1393811-7 1-1393811-0 1-1393811-1 V23154-N4XX 5A, size II 24.00 11.00 60.00 27.00 110.00 49.00 40.00 92.00 164.00 647 766 807 890 4700 15000 V23154N4721F104 V23154N4734F104 V23154N4735F104 1393811-8 1-1393811-2 1-1393811-3 V23162-A0XX standard, size I 5.00 1.80 12.00 5.30 12.00 5.30 15.00 6.80 20.00 8.90 20.00 8.90 20.00 11.90 20.00 11.90 24.00 11.20 24.00 11.20 24.00 11.00 24.00 11.00 24.00 14.50 24.00 14.50 32.00 16.90 32.00 16.90 32.00 16.90 32.00 22.60 48.00 23.00 48.00 23.00 48.00 30.00 48.00 30.00 72.00 36.00 7.20 20.00 20.00 24.50 32.00 32.00 32.00 32.00 36.00 36.00 40.00 40.00 40.00 40.00 54.00 54.00 54.00 54.00 75.00 75.00 75.00 75.00 100.00 893 655 655 692 727 727 727 727 823 823 647 647 647 647 602 602 602 602 720 720 720 720 894 28 220 220 325 550 550 550 550 700 700 890 890 890 890 1700 1700 1700 1700 3200 3200 3200 3200 5800 V23162A711B104 V23162A717B104 V23162A717B604 V23162A719B104 V23162A720B104 V23162A720B604 V23162A720C104 V23162A720C404 V23162A421B104 V23162A421B604 V23162A721B104 V23162A721B604 V23162A721C104 V23162A721C404 V23162A722B101 V23162A722B104 V23162A722B604 V23162A722C104 V23162A726B104 V23162A726B604 V23162A726C404 V23162A735C104 V23162A404B104 2-1393818-5 2-1393818-8 2-1393818-9 3-1393818-2 3-1393818-3 3-1393818-4 3-1393818-5 3-1393818-6 1393818-6 1393818-7 3-1393818-7 3-1393818-8 4-1393818-0 4-1393818-1 4-1393818-5 4-1393818-6 4-1393818-7 4-1393818-8 5-1393818-1 5-1393818-2 5-1393818-3 5-1393818-5 1393818-1 All specifications subject to change. Consult Tyco Electronics for latest specifications. 14 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Coil Data (values at 20 C) Nominal Voltage Unom Vdc Operating voltage range Minimum Voltage Umin Vdc Maximum voltage Umax Vdc Ordering Information Coil power mW Coil Resistance 15% Relay code Tycp part number V23162-A0XX standard, size I 72.00 36.00 72.00 36.20 72.00 36.20 72.00 48.40 72.00 48.40 110.00 65.00 125.00 61.00 125.00 81.00 100.00 114.00 114.00 114.00 114.00 164.00 190.00 190.00 894 682 682 682 682 807 748 748 5800 7600 7600 7600 7600 15000 20900 20900 V23162A404B604 V23162A704B104 V23162A704B604 V23162A704C402 V23162A704C404 V23162A735C404 V23162A703B104 V23162A703C404 1419147-6 1-1393818-9 2-1393818-0 2-1393818-1 2-1393818-2 5-1393818-6 1-1393818-6 1-1393818-7 V23162-A0XX 5A, size I 1.10 12.00 12.00 24.00 24.00 24.00 33.00 33.00 48.00 72.00 72.00 72.00 125.00 0.50 5.30 7.10 11.00 11.00 14.50 16.00 16.00 30.00 48.00 36.20 48.40 81.00 1.70 20.00 20.00 40.00 40.00 40.00 54.00 54.00 75.00 100.00 114.00 114.00 190.00 807 655 655 647 647 647 641 641 720 894 682 682 748 1.5 220 220 890 890 890 1700 1700 3200 5800 7600 7600 20900 V23162A702F106 V23162A717F105 V23162A717F106 V23162A721F101 V23162A721F105 V23162A721F106 V23162A722F101 V23162A722F105 V23162A726F106 V23162A404F106 V23162A704F105 V23162A704F106 V23162A703F106 1-1393818-5 3-1393818-0 3-1393818-1 4-1393818-2 4-1393818-3 4-1393818-4 4-1393818-9 5-1393818-0 5-1393818-4 1393818-2 2-1393818-3 2-1393818-4 1-1393818-8 V23162-B0XX standard, size II 7.00 3.60 8.50 7.60 10.00 5.80 12.00 7.10 12.00 7.10 12.00 8.70 15.00 9.10 20.00 11.90 20.00 11.90 20.00 11.90 20.00 11.90 20.00 17.70 20.00 14.40 20.00 17.70 24.00 15.00 24.00 15.00 24.00 14.50 24.00 14.50 24.00 14.50 24.00 22.00 24.00 22.00 32.00 22.60 32.00 22.60 32.00 22.60 32.00 33.80 48.00 30.00 48.00 30.00 48.00 30.00 10.50 14.00 16.50 20.00 20.00 20.00 24.50 32.00 32.00 32.00 32.00 32.00 32.00 32.00 36.00 36.00 40.00 40.00 40.00 40.00 40.00 54.00 54.00 54.00 54.00 75.00 75.00 75.00 845 657 667 655 655 655 692 727 727 727 727 727 727 727 823 823 647 647 647 647 647 602 602 602 602 720 720 720 58 110 150 220 220 220 325 550 550 550 550 550 550 550 700 700 890 890 890 890 890 1700 1700 1700 1700 3200 3200 3200 V23162B712B110 V23162B715C110 V23162B716B110 V23162B717B110 V23162B717B610 V23162B717C112 V23162B719B110 V23162B720B110 V23162B720B112 V23162B720B117 V23162B720B610 V23162B720C110 V23162B720C112 V23162B720C410 V23162B421B110 V23162B421B610 V23162B721B110 V23162B721B112 V23162B721B610 V23162B721C110 V23162B721C410 V23162B722B110 V23162B722B112 V23162B722B610 V23162B722C410 V23162B726B110 V23162B726B112 V23162B726B610 8-1393818-1 8-1393818-4 8-1393818-5 8-1393818-7 8-1393818-8 8-1393818-9 9-1393818-1 9-1393818-4 9-1393818-5 9-1393818-6 9-1393818-7 9-1393818-8 9-1393818-9 1393819-1 6-1393818-1 6-1393818-3 1393819-4 1393819-5 1-1393819-0 1-1393819-2 1-1393819-3 1-1393819-5 1-1393819-6 1-1393819-7 1-1393819-8 2-1393819-0 2-1393819-1 2-1393819-3 All specifications subject to change. Consult Tyco Electronics for latest specifications. 15 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Coil Data (values at 20 C) Nominal Voltage Unom Vdc Operating voltage range Minimum Voltage Umin Vdc Maximum voltage Umax Vdc Ordering Information Coil power mW Coil Resistance 15% Relay code Tycp part number V23162-B0XX standard, size II 48.00 45.00 60.00 36.00 72.00 48.00 72.00 48.40 72.00 48.40 72.00 48.40 110.00 65.00 110.00 65.00 110.00 98.00 110.00 98.00 125.00 81.00 125.00 81.00 75.00 92.00 100.00 114.00 114.00 114.00 164.00 164.00 164.00 164.00 190.00 190.00 720 766 894 682 682 682 807 807 807 807 748 748 3200 4700 5800 7600 7600 7600 15000 15000 15000 15000 20900 20900 V23162B726C110 V23162B734B610 V23162B404B110 V23162B704B110 V23162B704B112 V23162B704B610 V23162B735B110 V23162B735B610 V23162B735C110 V23162B735C410 V23162B703B110 V23162B703B610 2-1393819-6 2-1393819-9 5-1393818-7 7-1393818-6 7-1393818-7 7-1393818-8 3-1393819-0 3-1393819-1 3-1393819-2 3-1393819-3 7-1393818-3 7-1393818-4 V23162-B0XX 5A, size II 7.00 12.00 15.00 20.00 24.00 24.00 32.00 48.00 72.00 110.00 125.00 3.60 7.10 9.10 11.90 15.00 14.50 22.60 30.00 48.40 65.00 81.00 10.50 20.00 24.50 32.00 36.00 40.00 54.00 75.00 114.00 164.00 190.00 845 655 692 727 823 647 602 720 682 807 748 58 220 325 550 700 890 1700 3200 7600 15000 20900 V23162B712F104 V23162B717F104 V23162B719F104 V23162B720F104 V23162B421F104 V23162B721F104 V23162B722F104 V23162B726F104 V23162B704F104 V23162B735F104 V23162B703F104 8-1393818-2 9-1393818-0 9-1393818-3 1393819-2 6-1393818-4 1-1393819-4 1-1393819-9 2-1393819-7 8-1393818-0 3-1393819-4 7-1393818-5 V23162-H0XX standard, size II 8.50 5.10 20.00 11.90 20.00 11.90 20.00 17.70 20.00 17.70 24.00 15.00 24.00 14.50 24.00 14.50 24.00 22.00 32.00 33.80 32.00 33.80 14.00 32.00 32.00 32.00 32.00 36.00 40.00 40.00 40.00 54.00 54.00 657 727 727 727 727 823 647 647 647 602 602 110 550 550 550 550 700 890 890 890 1700 1700 V23162H715B110 V23162H720B110 V23162H720B610 V23162H720C410 V23162H720C610 V23162H421B610 V23162H721B110 V23162H721B610 V23162H721C410 V23162H722C110 V23162H722C410 4-1393819-2 4-1393819-4 4-1393819-6 4-1393819-7 4-1393819-8 3-1393819-7 4-1393819-9 5-1393819-0 5-1393819-1 5-1393819-3 5-1393819-4 V23162-H0XX 5A, size II 7.00 3.60 15.00 9.10 24.00 14.50 24.00 14.50 32.00 22.60 72.00 48.40 125.00 81.00 10.50 24.50 40.00 40.00 54.00 114.00 190.00 845 692 647 647 602 682 748 58 325 890 890 1700 7600 20900 V23162H712F104 V23162H719F104 V23162H721F104 V23162H721F107 V23162H722F104 V23162H704F104 V23162H703F104 4-1393819-1 4-1393819-3 5-1393819-2 1419147-7 5-1393819-5 4-1393819-0 3-1393819-9 All specifications subject to change. Consult Tyco Electronics for latest specifications. 16 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Instructions for Impulse Operation The maximum voltage stated in the table (page 6) can be increased for impulse operation as follows: UII Impuls = UII tamb = q = UII tamb . q Maximum continuous voltage at ambient temperature t amb Factor The impulse voltage must not exceed 80% of the test voltage (winding/frame or winding/winding) or 2.5 times the value of the maximum voltage listed in the table (page 6). Ift ED 3 s then q = Ift ED t2 If tED Pulse width Cycle time > 3 s the value of q must be obtained from the nomograph (next page). = = = Examples of various periodic pulse trains (energizing side) 1. Periodic recurrence of one energizing pulse 2. Periodic recurrence of two unequal energizing pulses tED tI + tII = = tI + tII Pulse widths within one cycle All specifications subject to change. Consult Tyco Electronics for latest specifications. 17 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Nomograph for Determining Factor q All specifications subject to change. Consult Tyco Electronics for latest specifications. 18 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Contact Data B104/B110/ B112 Ordering code block 3 Number of contacts and Type Contact assembly B604/B610/ C104/C110/ C404/C410 F104 ... F107 B612 C112 max. 4 changeover contacts, 2 break contacts or 6 make contacts single contacts silver, gold F gold-flashed 150 Vdc 36 Vdc Contact material Max. switching voltage Max. switching current Max. switching capacity bifurcated contacts silver, gold F gold-flashed 150 Vdc 36 Vdc single contacts silver, gold-flashed 250 Vdc 125 Vac 30 Vac 125 Vac 30 Vac 250 Vac 2A 35 to 70 W see load limit curve below 50 VA 0.2 A 2A 35 to 70 W see load limit curve below 50 VA 0.2 A 5A 50 to 140 W see load limit curve below 500 VA 5W 5 VA Max. continuous current at max. ambient temperature 5W 5 VA 2A 5A Max. DC Load Breaking Capacity for contact sets B1xx and C1 xx for contact sets F1xx 150 250 V_ V_ 200 120 140 W U U 70 W 150 100 100 W 100 80 80 60 60 50 50 40 40 50 W 40 W 30 30 0,3 0,4 0,5 0,6 0,8 1 1,5 I 2A 20 0,2 0,3 0,4 0,5 0,6 0,8 1 1,5 2 3 I 4 5A Safe breaking, no stationary arc Contact material silver, gold-flashed I U = switching current = switching voltage All specifications subject to change. Consult Tyco Electronics for latest specifications. 19 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Contact sets Size I Number of contacts and type 2 changeover contacts 2 make contacts 2 break contacts 1 break 1 make contact Symbols with base conncections coil I 3 - coil II + 2 4 - + 1 Contacts in release condition, coil polarity to set the relay Contact assembly Contact material silver, gold-flashed Ordering code block 3 Contact material gold F Ordering code block 3 single contacts bifurcated contacts B104 C104 B604 C404 single contacts F105 F107 F106 Size II Number of contacts and type 6 make contacts 4 changover contacts 2 changover contacts Symbols with base conncections coil I 3 - coil II + 2 4 - + 1 Contacts in release condition, coil polarity to set the relay Contact assembly Contact material silver, gold-flashed Ordering code block 3 Contact material gold F Ordering code block 3 single contacts bifurcated contacts single contacts bifurcated contacts single contacts B112 C112 B110 C110 F104 B610 C410 B612 All specifications subject to change. Consult Tyco Electronics for latest specifications. 20 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 Insulation Ordering code block 3 Test voltage (1 min) winding / frame contact / contact contact / frame contact / coil B1xx B6xx C1xx C4xx 500 Vacrms 500 Vacrms 500 Vacrms 1000 Vacrms F1xx 500 Vacrms 1000 Vacrms 1000 Vacrms 1500 Vacrms General Data Ordering code block 3 Operate time at Unom and 20 C, typical Reset time typical B1xx B6xx C1xx 7.5 ms 3 ms Maximum switching rate without load 50 operations/s Ambient temperature range acc. to EN 61810-1 / IEC 61810-1 and VDE 0435 part 201 -40 C ... +70 C Thermal resistance 50 K/W Maximum temperature 100 C Continuous thermal load 1.6 W Degree of protection acc. to EN 60529 / IEC 60529 / VDE 0470 part 1 F1xx 10 operations/s dust-protected IP 30 or hermetically sealed IP 67 approx.108 operations Mechanical endurance Mounting position Processing information C4xx approx. 107 operations any Ultrasonic cleaning should be avoided if possible or carried out only after consulting the manufacturer Weight V23154-C0/-MO Size I V23154-D0/-NO Size II V23162-A0xxx Size I V23162-B0xxx Size II All specifications subject to change. Consult Tyco Electronics for latest specifications. approx. 20 g approx. 25 g approx. 30 g approx. 35 g 21 of 23 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay N V23154/V23162 IM Relays D2n Relays 4th generation slim line - low profile polarized 2 c/o telecom signal relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 1.5 ... 24 V, coil power consumption of 50 ... 200 mW, latching relays with 1 coil 100 mW. The IM relay is available as through hole and surface mount type (J-Legs and Gull Wings) and capable to switch loads up to 60 W/62,5 VA. It is currently the only 2 A rated 4G relay on the market. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The IM relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 10 x 6 mm board space and 5.65 mm height. 2nd generation non polarized 2 c/o relay for telecom and various other applications. Nominal voltage range from 3 ... 48 V, coil power consumption from 150 .... 500 mW. The D2n relay is capable to switch currents up to 3 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 20 x10 mm board space and 11 mm height. P2 Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 140 mW, latching relays with 1 coil 70 mW. The P2 Relay is available as through hole or surface mount type and capable to switch currents up to 5 A. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The P2 relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height. FX2 Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW. The FX2 relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The FX2 relay is tested according CECC/ IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10,7 mm height. FT2 / FU2 Relays P1 Relays Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for a wide range of applications, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 65 mW, latching relays with 1 coil 30 mW. The P1 relay is available as through hole or surface mount type and capable to switch currents up to 1 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 13 x 7,6 mm board space and 7 mm height for THT or 8 mm height for SMT version. W11 Relays Low cost, non polarized 1 c/o relay for various applications. Nominal voltage range from 3 ... 24 V, coil power consumption 450 mW, sensitive versions 200 mW. The W11 relay is capable to switch currents up to 3 A. Dielectric strength 1000 Vrms. Dimensions approx. 15,6 x 10,6 mm board space and 11,5 mm height. Reed Relays High sensitive, non polarized relay for telecom and various other applications, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal voltage range from 5 ... 24 V, coil power consumption 50...280 mW for 1 n/o and 125 ... 280 mW for 2 n/o or 1 c/o versions. Reedrelays are available in DIP or SIL housing and capable to switch currents up to 0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric strength 1500 Vdc. Dimensions approx. 19,3 x 7 mm board space and 5 ... 7,5 mm height for DIP or 19,8 x 5 mm board space and 7,8 mm height for SIL version. Cradle Relays 3rd generation non polarized, non latching 2 c/o telecom relay with bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power consumption 200 ... 300 mW. Most sensitive 48 V relay. Available as through hole and surface mount type. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The FT2/FU2 relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height. Extremely reliable and mature relay family of 1st generation for various signal switching applications. Available as non polarized, polarized / latching and relay with AC coil. The benefit is the possibility of combining various contact sets from 1 up to 6 poles, single and bifurcated contacts, different contact materials with a coil voltage range from 1,5 Vdc to 220 Vac. Cradle relays are available as dust protected and hermetically sealed versions, with plug in or solder terminals and are capable to switch currents up to 5 A. Forcibly guided (linked) contact sets optional. Dielectric strength 500 Vrms. Dimensions from approx. 19 x 24 to 19x35 mm board space and 30 mm height. FP2 Relays Other Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW.. The FP2 Relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills FCC part 68 (1,5 kV - 10 / 160 s). The FP2 is tested according CECC/IECQ approved. Dimensions approx. 14 x 9 mm board space and 5 mm height. We offer a variety of different relay families for maintenance and replacement purposes. These relays are up to 60 years old now, such as Card Relay SN (V23030 series), Small General Purpose Relay (V23006 series), Small Polarized Relay (V23063 ... V23067 and V23163 ... V23167 series). Accessories like sockets, hold down springs, etc. optional. MT2 2nd generation non polarized, non latching 2 c/o telecom and signal relay with bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power consumption 150/200/300/400 and 550 mW. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 20 x 10 mm board space and 11 mm height. High Frequency Relays HF3 / HF3S / HF6 series RF relays offering excellent RF characteristics in a small package. All HF series relays are suitable for SMD soldering processes. Available as non latching or latching versions with 1 or 2 coils and a nominal coil voltage range from 3 ... 24 V, a coil power consumption of 140 mW or 70 mW (single coil latching types). HF3: Low cost RF relay suitable up to 3 GHz. Impedance 50 and 75 Ohm. 50 W hot switching and 50 W RF power carry capability. Dimensions 14.6 x 7.3 x 10.3 mm. HF3S: High performance, high power RF relay suitable up to 3 GHz, 50 W hot switching and 150 W RF power carry capability. Dimensions 15 x 7.6 x 10.6 mm. HF6: High performance, high power RF relay suitable up to 6 GHz, 50 W hot switching and 50 W RF power carry capability. Dimensions 15 x 7.6 x 10.6 mm. All specifications subject to change. Consult Tyco Electronics for latest specifications. 22 of 23 Tyco Electronics Logistics AG Werk Axicom Au Seestrasse 295 CH-8804 Au-Wadenswil / Switzerland Phone +41 44 782 91 11 Fax +41 44 782 90 00 E-mail: axicom@tycoelectronics.com Tyco Electronics Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38573 Fax +49 30 386 38575 E-mail: axicom@tycoelectronics.com Tyco Electronics EC Trutnov s.r.o. Komenskeho 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com AXICOM Telecom-, Signal and RF Relays Tyco Electronics Corporation POB 3608, Harrisburg, PA 17105, USA Phone +1 800-522-6752