AC READ CHARACTERISTICS
Over Operating Range with VPP = VCC
PARAMETER SYMBOL 57C128FB-35 57C128FB-45 57C128FB-55 57C128FB-70 UNITS
MIN MAX MIN MAX MIN MAX MIN MAX
Address to Output Delay tACC 35 45 55 70
CE to Output Delay tCE 35 45 55 70
OE to Output Delay tOE 20 25 25 25 ns
Output Disable to
Output Float tDF 20 25 25 25
Address to Output Hold tOH 0000
DC READ CHARACTERISTICS
Over Operating Range with VPP = VCC
SYMBOL PARAMETER TEST CONDITIONS MIN MAX UNITS
VIL Input Low Voltage (Note 5) –0.1 0.8 V
VIH Input High Voltage (Note 5) 2.0 VCC + 0.3 V
VOL Output Low Voltage IOL = 16 mA 0.4 V
VOH Output High Voltage IOH = –4 mA 2.4 V
ISB1 VCC Standby Current (CMOS) (Notes 1 and 3) 500 µA
ISB2 VCC Standby Current (TTL) (Notes 2 and 3) 15 mA
(Notes 1 and 4) Comm'l 30 mA
ICC1 VCC Active Current (CMOS) Outputs Not Loaded Industrial 40 mA
Military 40 mA
(Notes 2 and 4) Comm'l 50 mA
ICC2 VCC Active Current (TTL) Outputs Not Loaded Industrial 60 mA
Military 60 mA
IPP VPP Supply Current VPP = VCC 100 µA
VPP VPP Read Voltage VCC –0.4 VCC V
ILI Input Leakage Current VIN = 5.5V or Gnd –10 10 µA
ILO Output Leakage Current VOUT = 5.5 V or Gnd –10 10 µA
OPERATING RANGE
RANGE TEMPERATURE VCC
Commercial 0°C to +70°C +5V ± 10%
Industrial –40°C to +85°C +5V ± 10%
Military –55°C to +125°C +5V ± 10%
WS57C128FB
3-8
ABSOLUTE MAXIMUM RATINGS*
Storage Temperature............................–65° to + 150°C
Voltage on any Pin with
Respect to Ground ....................................–0.6V to +7V
VPP with Respect to Ground...................–0.6V to + 13V
ESD Protection..................................................>2000V
*NOTICE:
Stresses above those listed under "Absolute Maximum
Ratings" may cause permanent damage to the device.
This is a stress rating only and functional operation of
the device at these or any other conditions above
those indicated in the operational sections of this
specification is not implied. Exposure to absolute
maximum rating conditions for extended periods of
time may affect device reliability.
NOTES: 1. CMOS inputs: GND ± 0.3V or VCC ± 0.3V.
4. Add 4 mA/MHz for A.C. power component.
2. TTL inputs: VIL
≤0.8V, VIH ≥2.0V. 5. These are absolute voltages with respect to device ground pin and
3. Add 1 mA/MHz for A.C. power component. include all overshoots due to system and/or tester noise.
Do not attempt to test these values without suitable equipment.