E2ECE2EC
2
Specifications
JRATINGS/CHARACTERISTICS
Description 2-wire DC models 3-wire DC models (NPN) 3-wire DC models (PNP)
Part number E2EC-
CR8Dj
E2EC-
C1R5Dj
E2EC-
C3Dj
E2EC-
X4Dj
E2EC-
CR5C1
E2EC-
C2R5C1
E2EC-
CR5B1
E2EC-
C2R5B1
Body Size 3mm 5.4 mm 8mm 3mm 3mm 8mm 3mm 8mm
Type Inductive
Supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. 5to24VDC(4.75to30VDC),ripple(P-P):10%max.
Current consumption --- 10 mA max.
Leakage current 0.8 mA max. ---
Sensing object Magnetic metals (Refer to Engineering Data for non-magnetic metals.)
Sensing distance 0.8 mm
±15%
1.5 mm
±10%
3mm
±10%
4mm
±10%
0.5 mm
±15%
2.5 mm
±10%
0.5 mm
±15%
2.5 mm
±10%
Sensing distance (with
standard sensing
object)
0to
0.56 mm
(0.02 in)
(iron: 5 x 5
x 1 mm)
0to
1.05 mm
(0.04 in)
(iron: 5 x 5
x 1 mm)
0to
2.1 mm
(0.08 in)
(iron: 8 x 8
x 1 mm)
0to
2.8 mm
(0.11 in)
(iron: 12 x
12 x 1 mm)
0to
0.3 mm
(0.011 in)
(iron: 5 x 5
x 1 mm)
0to
1.7 mm
(0.067 in)
(iron: 8 x 8
x 1 mm)
0to
0.3 mm
(0.011 in)
(iron: 5 x 5
x 1 mm)
0to
1.7 mm
(0.067 in)
(iron: 8 x 8
x 1 mm)
Differential travel 10% max. of sensing distance
Control Type DC 2-wire NPN-NO open collector PNP-NO open collector
output Max. load 5to100mA 100 mA max. at 30 VDC
Residual voltage 3.0 V max. (under load current of 100 mA with cable
length of 2 m)
1.0 V max. (under load current of 100 mA with cable
length of 2 m)
Operation (with
sensing object
approaching)
D1 models: Load operates.
D2 models: Load is reset.
Load operates.
Temperature influence ±20% max. of sensing distance at 23°C (73.4°F) in temperature range of --25°C and 70°C(--13°F to 158°F)
Voltage influence ±2.5% max. of sensing distance in rated voltage
when operated within ±15% of the rated supply
voltage
±5% max. of sensing distance in rated voltage range
of 4.75 to 30 V
Response frequency
(see note)
1.5 kHz 1kHz
Circuit protection Surge absorber and load short-circuit protection Surge absorber
Indicator D1 models: Operation indicator (red LED), operation
set indicator (green LED)
D2 models: Operation indicator (red LED)
Detection indicator (red LED)
Head Case Brass
material Sensing
surface
ABS resin
Weight Approx. 45 g (1.59 oz)
Enclosure rating IEC IP67 IEC IP64
Ambient temperature Operating: --25°Cto70°C(--13°F to 158°F)withnoicing
Ambient humidity Operating: 35% to 95%
Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z directions
Shock resistance Malfunction: 1,000 m/s2(3,280 ft/sec2) (approx.
100G) for 10 times each in X, Y, and Z directions
Malfunction: 500 m/s2(1,640 ft/sec2) (approx. 50G)
for 10 times each in X, Y, and Z directions
Insulation resistance 50 MΩ(at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC (50/60 Hz) for 1 min between current
carry parts and case
500 VAC (50/60 Hz) for 1 min between current carry
parts and case
Note: Response frequencies are mean values measured with standard sensing objects, each separated from one another with a dis-
tance that is double the size of the sensing object and located at a distance that is half the sensing distance.