Optimal Installation
Exclusive dual port design eliminates
the need for additional splicing
connectors when wiring multiple
luminaires, minimizing component
costs and labor.
Daisy chain to...
PUSH WIRE® Connector for Luminaire Disconnect,
873 Series LUMI-NUTS®
...Multiple
Fixtures
----------- ________________
Field Wiring Factory Wiring
Push-wire connectors for luminaire disconnect,
2-pole connectors
873-902
873-902/K194-4045 25 pc/box
873-902/VE00-0500 500 pc/bag
873-902/VE00-5000 5,000 pc/bag
Item Pack.-unit
No. pcs
Push-wire connectors for luminaire disconnect,
3-pole connectors, for switching and dimming applications
873-903
873-903/K194-4045 20 pc/box
873-903/VE00-0500 500 pc/bag
Item Pack.-unit
No. pcs
Listed
PUSH WIRE® Connector for Luminaire Disconnect,
873 Series LUMI-NUTS®
...Multiple
Ballasts
*
u2QOsKfNSDFaAJ9q:;[
*
u2QOKfNSDFAJ9q:;[ *
u2QOsKfNSDFaAJ9q:;[
3-x-0,75-–-1,5-mm2„e“- 3-x-AWG-18
-–-16-„sol.“
5-x-0,75-–-1,5-mm2„e“- 5-x-AWG-18
-–-16-„sol.“
400 V/ 4 kV/ 2** 600 V, 10 A u
18 A 600 V, 10 A 2
8-x-0,75-–-1,5-mm2„e“- 8-x-AWG-18
-–-16-„sol.“
400 V/ 4 kV/ 2** 600 V, 10 A u
18 A 600 V, 10 A 2
3-x-0.75-–-1.5-mm2“s”- 3-x-AWG-18
-–-16-“sol.”
5-x-0.75-–-1.5-mm2“s”- 5-x-AWG-18
-–-16-“sol.”
400 V/ 4 kV/ 2** 600 V, 10 A u
18 A 600 V, 10 A 2
l 10 – 13 mm / 0.45 in
8-x-0.75-–-1.5-mm2“s”
8-x-AWG-18-–
-16-“sol.”
400 V/ 4 kV/ 2** 600 V, 10 A u
18 A 600 V, 10 A 2
l 10 – 13 mm / 0.45 in
3-x-0,75-–-1,5-mm2«r»- 3-x-AWG-18
-–-16-«s»
5-x-0,75-–-1,5-mm2«r»- 5-x-AWG-18
-–-16-«s»
400 V/ 4 kV/ 2** 600 V, 10 A u
18 A 600 V, 10 A 2
l 10 – 13 mm / 0.45 in
8-x-0,75-–-1,5-mm2«r»- 8-x-AWG-18
-–-16-«s»
400 V/ 4 kV/ 2** 600 V, 10 A u
18 A 600 V, 10 A 2
l 10 – 13 mm / 0.45 in
Male Connector Female Connector
2 x AWG 18-12 “sol.” per pole 1 x AWG 18 “sol.” per pole
2 x AWG 16-12 <19 “str.” per pole 600 V
600 V 6 A
20 A Current capacity at
max conductor size
l 11-13 mm/0.47 in 9-11 mm/0.39 in
Item Pack.-unit
No. pcs
Push-wire connectors for luminaire disconnect,
3-pole connectors, with “make first/break last” ground circuit
873-953
873-953/VE00-0500 500 pc/bag
Male Connector Female Connector
2 x AWG 16-12 “sol.” per pole 1 x AWG 18 “sol.” per pole
2 x AWG 16-12 <19 “str.” per pole 600 V
600 V 6 A
20 A Current capacity at
max conductor size
l 11-13 mm/0.47 in 9-11 mm/0.39 in
Male Connector Female Connector
2 x AWG 16-12 “sol.” per pole 1 x AWG 18 “sol.” per pole
2 x AWG 16-12 <19 “str.” per pole 600 V
600 V 6 A
20 A Current capacity at
max conductor size
l 11-13 mm/0.47 in 9-11 mm/0.39 in
L
N
Daisy Chain
Additional Specifications
Meets: 2008 NEC 410.130(G) and CEC 30-308(4) for non-residential fluorescent luminaires
UL2459 listed insulated multi-pole splicing connector (luminaire disconnect)
CSA 22.2 No. 2459 certified insulated multi-plole splicing connector (luminaire disconnect)
EN/IEC 60998 and EN/IEC61984 certified connector
Max operating temperature: 105oC
Flammability rating: UL94V-0
Luminaire Disconnect
3NLY
Fits through 1/2 in knockout
42mm
13.2mm
13mm
42mm
13.2mm
19mm
42mm
13.2mm
19mm