NESSCAP
®
Ultracapacitor Datasheet
© NESSCAP 2003. All Rights reserved. Design, Specifications are subject to change without notice.
NESSCAP Co., Ltd.
750-8 Gome-Ri, Kiheung-Eup, Yongin-City, Kyonggi-Do 449-901, Korea
Tel: +82-31-289-0721 Fax: +82-31-286-6767 e-mail: marketing@nesscap.com
www.nesscap.com
NESSCAP 100F/2.7V
ESHSR-0100C0–002R7
Features
- Cylindrical cell
- Snap-in terminals
Dimensions in mm (not to scale)
Specifications
Rated Capacitance, C (DCC
(
1
)
, 25oC) 100 Farads
(1) Discharging with constant current
Capacitance Tolerance -10% / +20%
Rated Voltage, VR 2.7 V
Surge Voltage 2.85 V
Rated Current (25oC)(2) 21.4 A
(2) 5 sec discharge rate to 1/2 V
R
Max. Current (25oC)(3) > 58.7 A
(3) 1 sec discharge rate to 1/2 V
R
Max. Stored Energy (at VR) 364.5J (0.1013 Wh)
Gravimetric 4.50 Wh/kg
Specific Energy Volumetric 5.92 Wh/l
Gravimetric 6.23 kW/kg
Specific Power(4)
(at matched load) Volumetric 8.20 kW/l
(4) Power density at which one-half the energy of
the discharge is in the form of electricity and
one-half is in heat.
AC (1kHz) 10 m
Maximum Internal
Resistance (ESR) DC (11A ) 13 m
Dimensions
φ
22 x l 45 mm
Volume 17.1 ml
Weight 22.5 g
Operating temperature range(5) -40 ~ 60 °C
(5) ⏐∆C< 20% and ESR < 2 times of initially
measured value at 25
o
C, respectively
Storage temperature rang e -40 ~ 70 °C
Max. Leakage Current, LC( 12h, 25oC) 1.7 mA
Life Time at RT (6) 10 years
Cycle Life (25oC)(6), (7) 500,000 cycles
(6) ⏐∆C< 30% and ESR < 2 times of initially
measured value, respectively and LC < specified
value
(7) 1 cycle: charging to V
R
for 20s, constant
voltage charging for 10s, discharging to 1/2V
R
for 20s, rest for 10s
Safety vent
6±1 PCB
p
atterns : 2-Ø
2±0.1
45+2max.
Ø22+1max.
Sleeve
10±
0.2