Special Features
Electrical Specs
Special Features
40 Amps
•High efficiency (91% Typical)
•-40°C to +70°C Ambient Air Operation
•Industry standard package
1.48" x 2.30" x 0.38"
•High capacitive load limit on start-up
•Remote sense compensation
•Basic insulation
•Regulation to zero load
•Fixed frequency switching (200KHz)
Input
Input Range 36 to 75 VDC
Input Surge 100V /100ms
Efficiency 91%@3.3V Typ
Output
Load Regulation 10mV typical down to no load
(3V3 output and below)
Line Regulation 10mV typical
(3V3 output and below)
Voltage Tolerance ±1%
Noise/Ripple 100mV max typ
150mV max for 5V
Remote sense Up to 10% of Vo
Transient Response 5% max deviation with 25% to 75% full
(output 5V and above)
200mV (output below 5V)
500µs (max) recovery
Overvoltage Protection 140% nominal output
Current Limit 140% nominal output
Switching Frequency 200KHz (typ)
Control
Voltage Adjust 90 to 110% for 5V output
80 to 110% for 3.3V and below
Enable TTL compatible
(positive & negative enable options)
Ambient air operating temperature range:
-40°C to +70°C
Storage temperature: -40°C to +125°C
Overtemperature protection: 115°C typical
MTBF: > 1 million hours
UL,cUL 60950
TUV EN60950
Environmental
Total Power: 144W
Input Voltages: 48V
No. of Outputs: Single
Safety
ALQ40
High Efficiency Quarter Brick
Preliminary
REV 03: Dec 2003