1075 FIBER SENSORS High Speed High Accuracy Eddy Current Type Digital Displacement Sensor GP-X SERIES Related Information General terms and conditions.............. F-3 Glossary of terms.......................... P.1587 Selection guide............................ P.1021~ General precautions...................... P.1595 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller panasonic.net/id/pidsx/global High-speed sampling and high resolution. The new choice for even more variegated data collection and processing. They perform with a 0.3 % F.S. linearity for stainless steel and iron Because they perform with a 0.3 % F.S. linearity, they can be used for sensing stainless steel and iron enabling precise measurements not affected by the work's material. Specifications corresponding to each material (stainless steel, iron, aluminum) has already been inputted in the controller enabling the easy selection of the setting that is the most suitable for the particular material used. GP-A Aluminum Stainless steel Iron Distance Before correction Distance After correction We've realized a 25 s (40,000 times/sec.) ultra high sampling speed They possess a 0.02 % F.S. resolution for highly accurate measurement With a 25 s ultra high sampling speed, the GP-X series won't miss even high speed work displacements. With high resolution, 0.02 % F.S. (Note), they can perform high-accuracy measurements of micro-displacements. In particular, the sensor head GP-X3SE for 0.8 mm 0.049 in sensing can differentiate ultra micro displacement of 0.32 m 0.013 mil (Average number of samples: 64). Other Products GP-X Optimal correction of the output feature Output value STATIC CONTROL DEVICES Output value MEASUREMENT SENSORS These devices boast a 0.07 % F.S./C temperature characteristics By combining the sensor head with the controller, we've realized 0.07 % F.S./C. They are highly resistant to ambient temperature changes enabling stable microdisplacement measurements. Note: GP-XC3SE and GP-XC5SE Resolution: 0.04 % F.S. High Speed High Accuracy Eddy Current Type Digital Displacement Sensor GP-X SERIES APPLICATIONS 1076 FIBER SENSORS Stroke end sensing Eccentricity sensing Height sensing LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS GP-X3SE GP-X10M GP-X12ML SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS ENVIRONMENTAL RESISTANCE / VARIETY SENSOR OPTIONS IP67G sensor head variation Controller 6 types of sensor heads from the ultra compact o3.8 mm o0.150 in cylindrical type to the long range sensing type o22 mm o0.866 in are available. All sensor heads are oil-proof as per IP67G enabling safe, stable performance. NPN output type, PNP output type DIN 48 mm 1.890 in size SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES * Please check the resistivity of the sensor against the cutting oil you are using beforehand. LASER MARKERS PLC HUMAN MACHINE INTERFACES GP-X22KL Sensing range: 0 to 10 mm 0 to 0.394 in Appearance: o22 mm o0.866 in / M12 GP-X12ML Sensing range: 0 to 5 mm 0 to 0.197 in Appearance: M12 GP-X10M Sensing range: 0 to 2 mm 0 to 0.079 in Appearance: M10 GP-X3SE Sensing range: 0 to 0.8 mm 0 to 0.031 in Appearance : o3.8 mm o0.150 in GP-X5SE Sensing range: 0 to 1 mm 0 to 0.039 in Appearance : o5.4 mm o0.213 in GP-X8S Sensing range: 0 to 2 mm 0 to 0.079 in Appearance: o8 mm o0.315 in ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS MOUNTING / MAINTENANCE Sensor heads with superior workability and maintainability Replacement of sensor heads possible As a result of damage or other mishap rendering maintenance necessary, you can replace the sensor head with new one leaving the controller as it is. One-touch connector hook up The sensor head and the controller connection is a simple one-touch connector type. Sensor head extensions possible Between the sensor head and the controller, a GP-XCCJ7 extension cable (optional) can be used up to a 10 m 32.808 ft total length. One-touch connector Selection Guide Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products GP-X Sensor head Extension cable GP-XCCJ7: 7 m 22.966 ft Sensor cable: 3 m 9.843 ft Total length: 10 m 32.808 ft GP-A 1077 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS High Speed High Accuracy Eddy Current Type Digital Displacement Sensor GP-X SERIES FUNCTIONS The 5-digit, dual, 2-color digital display offers great visibility Digital input display enabling easy setting If the measurement results fall within the setting range (GO), they will appear on the lower digital display in green. If they are out of range (HI, LO), they will be displayed in the upper digital display in orange. The display position and color change allows for accurate visibility even for momentary changes. Its dual digital display enables numerical setting while verifying setting items for each mode. Even when sensing, it enables the verification of the main settings. Sensing values Upper threshold value Lower threshold value SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES Out of setting range (upper threshold) (Orange) Sensing values within setting range (Green) Out of setting range (lower threshold) (Orange) Setting value is verifiable even in sensing mode Simple setting mode Manual mode Average number of samples setting value The RS-232C communication connector is standard equipment It is capable of various controls such as saving measurement data to PC and the controller's inputted settings and loading stored memory. ENERGY MANAGEMENT SOLUTIONS Exclusive RS-232C cable (Accessory for the intelligent monitor GP-XAiM) Cable length: 3 m 9.843 ft [PC side connector: D-SUB (9 pins)] Link cable for controller communication unit (Optional) SL-F Cable length: 150 mm, 250 mm, 1,000 mm 5.906 in, 9.843 in, 39.307 in FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products GP-X GP-A Connector for RS-232C communication Controller communication unit GP-XCOM Enables sensors data comparisons and calculations 3-value judgment output for calculating measurement data conformity and calculation results between 2 interconnected controllers is rendered possible. The calculation function equipment renders digital panel controllers unnecessary. High Speed High Accuracy Eddy Current Type Digital Displacement Sensor GP-X SERIES OPTIONS 1078 FIBER SENSORS Datalink between sensors possible The controller communication unit GP-XCOM (optional) can be linked to up to 8 controllers and load via just one RS-232C cable each controller settings and measurement data to a PC. LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Maximum of eight units AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Controller communication unit Data sent to a PC via the RS-232C Link cable An intelligent monitor (GP-XAiM) optimal for collecting and analyzing measurement data is also available An intelligent monitor capable of the settings for each measurement conditions and waveform display monitoring. It can perform waveform monitoring, which could until now only be done by the oscilloscope, as well as the simple loading and saving onto a PC of settings for each condition and function. (Exclusive RC-232C cable is attached.) PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC BCD output unit GP-XBCD (Optional) Mutual interference prevention function The sensor head can be made interference prevention by linking up to 8 controllers via an interference prevention output cable and shifting the oscillation timing. This enables precise measurements to be obtained even in cases where many sensor heads are crowded in the same area. HUMAN MACHINE INTERFACES UV CURING SYSTEMS * When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid. Removable type terminal block It is equipped with a removable type European terminal block very convenient during assembly, when dividing the equipment into segments or when performing maintenance. It also features an reverse insertion prevention construction. 4 types of measurement modes available Measurement modes compatible to the most widely used applications are available. Because of this, inputting setting values can be done with ease. Please select the most appropriate mode to suit your specific application. 4 types of selectable memory functions The setting data can be processed in 4 types of memory when measuring. This function enables either the changing of the workpiece, the sensing of multiple products or sensing after product changeover to be done smoothly. 20 kHz high-speed data output The measurement data can be processed quickly in the PLC. (Sampling rate: 20 kHz) Cable with connector on one end for BCD output unit GP-XBCC3 (Optional) Cable length: 3 m 9.843 ft Controller side: BCD connector Output side: Multi-core cable GP-XBCC3 BCD output unit GP-XBCD European terminal block ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS Selection Guide Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products GP-X GP-A 1079 FIBER SENSORS High Speed High Accuracy Eddy Current Type Digital Displacement Sensor ORDER GUIDE LASER SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Type Appearance (mm in) Sensor heads Controller o3.8 o0.150 Non-threaded type sensor head PHOTOELECTRIC SENSORS o5.4 o0.213 0 to 1 mm 0 to 0.039 in 17 0.669 83 3.268 17 0.669 STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products GP-X GP-A Threaded type sensor head MEASUREMENT SENSORS M12 48 1.890 17 0.669 21 0.827 35 1.378 0 to 2 mm 0 to 0.079 in 0 to 5 mm 0 to 0.197 in M12 o22 o0.866 0 to 2 mm 0 to 0.079 in 48 1.890 SIMPLE WIRE-SAVING UNITS M10 Sensing range 0 to 0.8 mm 0 to 0.031 in 17 0.669 o8 o0.315 SENSOR OPTIONS WIRE-SAVING SYSTEMS GP-X SERIES 0 to 10 mm 0 to 0.394 in Set model No. (Sensor head model No.) Comparative output GP-XC3SE (GP-X3SE) NPN open-collector transistor GP-XC3SE-P (GP-X3SE) PNP open-collector transistor GP-XC5SE (GP-X5SE) NPN open-collector transistor GP-XC5SE-P (GP-X5SE) PNP open-collector transistor GP-XC8S (GP-X8S) NPN open-collector transistor GP-XC8S-P (GP-X8S) PNP open-collector transistor GP-XC10M (GP-X10M) NPN open-collector transistor GP-XC10M-P (GP-X10M) PNP open-collector transistor GP-XC12ML (GP-X12ML) NPN open-collector transistor GP-XC12ML-P (GP-X12ML) PNP open-collector transistor GP-XC22KL (GP-X22KL) NPN open-collector transistor GP-XC22KL-P (GP-X22KL) PNP open-collector transistor The controller is not available for sale by itself. Sensor heads can only be replaced with the sensor heads with the same set model name. Different sensor heads cannot be used. High Speed High Accuracy Eddy Current Type Digital Displacement Sensor GP-X SERIES OPTIONS 1080 FIBER SENSORS LASER SENSORS Designation BCD output unit Model No. GP-XBCD Description PHOTOELECTRIC SENSORS This unit outputs measurement values in BCD data format at a high speed. * Sampling frequency: 20 kHz MICRO PHOTOELECTRIC SENSORS AREA SENSORS Cable with connector on one end for BCD output unit GP-XBCC3 Length: 3 m 9.843 ft Controller communication unit GP-XCOM Up to 8 controllers can be linked PRESSURE / FLOW SENSORS SL-F150 Length: 150 mm 5.906 in INDUCTIVE PROXIMITY SENSORS SL-F250 Length: 250 mm 9.843 in SL-F1000 Length: 1,000 mm 39.370 in Intelligent monitor GP-XAiM Monitoring settings for each measurement condition and measurement waveforms is enabled by way of a PC. * One exclusive RS-232C cable (3 m 9.843 ft length) is attached. Extension cable for sensor head GP-XCCJ7 Length: 7 m 22.966 ft MS-SS3 Mounting bracket for GP-X3SE MS-SS5 Mounting bracket for GP-X5SE MS-SS8 Mounting bracket for GP-X8S Link cable for controller communication unit Sensor head mounting bracket Cable for BCD data output unit * 26-core cable with connector on one end SAFETY LIGHT CURTAINS / SAFETY COMPONENTS This cable links the controller communication units. Select as per the cable length. PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS This cable with connector is for extensions between the sensor head and controller. BCD output unit Cable with connector on one end for BCD output unit Controller communication unit Link cable for controller communication unit * GP-XBCD * GP-XBCC3 * GP-XCOM * SL-F MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS Intelligent monitor * GP-XAiM Extension cable for sensor head PLC * GP-XCCJ7 HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS BCD output unit GP-XBCD Cable with connector on one end for BCD output unit GP-XBCC3 Link cable for controller communication unit SL-F Controller communication unit GP-XCOM MACHINE VISION SYSTEMS UV CURING SYSTEMS Sensor head mounting bracket * MS-SS Selection Guide Laser Displacement Magnetic Displacement The sensor head can be easily fixed. Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products GP-X GP-A 1081 PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Controllers Type WIRE-SAVING SYSTEMS Set model No. Item Sampling frequency 40 kHz (25 s) Linearity (Note 2) 0.07 % F.S./C or less Analog voltage outputs (Note 4) Output voltage: -5 to +5 V (Note 5), Output impedance: 100 approx. Response time Comparative outputs (HI, GO, LO) Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products HI / GO / LO 3 value output HI : ON when measured value > the upper limit value GO: ON when upper limit value measured value lower limit value LO : ON when lower limit value > measured value Incorporated Photo-coupler input * Input current: 9 mA or less * Operating voltage: ON voltage 17 V or more (between +24 V and input) OFF voltage 4 V or less (between +24 V and input) * Input impedance: 5 k approx. Serial I/O Zero-set setting method Indicators MODE Photo-coupler input * Input current: 9 mA or less * Operating voltage: ON voltage 17 V or more (between 0 V and input) OFF voltage 4 V or less (between 0 V and input) * Input impedance: 5 k approx. RS-232C Push button setting / External input setting Orange LED (lights up when in mode status) HI Orange LED (lights up when the upper limit value is exceeded) GO Green LED (lights up when within the upper and lower limit value) LO Orange LED (lights up when less than the lower limit value) TIMING Green LED (lights up as per the external or internal trigger timing) Upper level digital display part 5 digit orange LED (display of numerical values out of upper and lower limit value) Lower level digital display part 5 digit green LED (display of numerical values within the upper and lower limit value) Environmental resistance Contact Displacement External input PNP open-collector transistor * Maximum source current: 100 mA * Applied voltage: 30 V DC or less (between comparative output and +V) * Residual voltage: 1.6 V or less (at 100 mA source current) 0.4 V or less (at 16 mA source current) DC-12 or DC-13 Short-circuit protection HUMAN MACHINE INTERFACES Magnetic Displacement 75 s (maximum speed) NPN open-collector transistor * Maximum sink current: 100 mA * Applied voltage: 30 V DC or less (between comparative output and 0 V) * Residual voltage: 1.6 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) Utilization category PLC Laser Displacement Within 0.3 % F.S. Temperature characteristics (Note 3) Output operation Selection Guide 150 mA or less Resolution (Note 2) LASER MARKERS UV CURING SYSTEMS EMC Directive, RoHS Directive 24 V DC 10 % Ripple P-P 10 % or less GP-XC3SE / GP-XC5SE: 0.04 % F.S. (64 times average processing) GP-XC8S / GP-XC10M / GP-XC12ML / GP-XC22KL: 0.02 % F.S. (64 times average processing) Output number MACHINE VISION SYSTEMS GP-XC-P Current consumption STATIC CONTROL DEVICES FA COMPONENTS PNP output GP-XC CE marking directive compliance MEASUREMENT SENSORS ENERGY MANAGEMENT SOLUTIONS NPN output Supply voltage SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS GP-X SERIES SPECIFICATIONS FIBER SENSORS LASER SENSORS High Speed High Accuracy Eddy Current Type Digital Displacement Sensor Pollution degree Ambient temperature Ambient humidity Vibration resistance Shock resistance Material GP-X Weight GP-A Accessory 3 (Industrial environment) 0 to +50 C +32 to +122 F (No dew condensation allowed), Storage: 0 to +50 C +32 to +122 F 35 to 85 % RH, Storage: 35 to 85 % RH 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each Enclosure: Polycarbonate Net weight: 120 g approx. ATA4811 (Controller mounting frame): 1 set Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 2) This value was obtained at a constant +25 C +77 F. 3) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and controller. 4) When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid. 5) Adjusted to a 0 to +5 V factory setting. High Speed High Accuracy Eddy Current Type Digital Displacement Sensor GP-X SERIES 1082 SPECIFICATIONS FIBER SENSORS LASER SENSORS Sensor heads Type Item Model No. Non-threaded type Threaded type For 0.8 mm 0.031 in sensing For 1 mm 0.039 in sensing For 2 mm 0.079 in sensing For 2 mm 0.079 in sensing For 5 mm 0.197 in sensing For 10 mm 0.394 in sensing GP-X3SE GP-X5SE GP-X8S GP-X10M GP-X12ML GP-X22KL Sensing range (Note 2) 0 to 0.8 mm 0 to 0.031 in 0 to 1 mm 0 to 0.039 in 0 to 2 mm 0 to 0.079 in 0 to 2 mm 0 to 0.079 in 0 to 5 mm 0 to 0.197 in 0 to 10 mm 0 to 0.394 in Standard sensing object Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in Temperature characteristics (Note 3) 0.07 % F.S./C or less Environmental resistance Pollution degree IP67 (IEC), IP67G (Note 6) Ambient temperature 250 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each 500 m/s acceleration (50 G approx.) in X, Y and Z directions five times each Material Shock resistance 2 Enclosure Stainless steel (SUS303) Cable protector Sensing part Brass (Nickel plated) - PAR ABS PA Cable High frequency coaxial cable with connector, 3 m 9.843 ft long (Note 4) Cable extension Extension up to total 10 m 32.808 ft is possible with the optional cable. Net Weight (Note 5) 40 g approx. 40 g approx. 40 g approx. 50 g approx. - Accessories 45 g approx. Model No. 80 g approx. Nut: 2 pcs., Toothed lock washer: 1 pc. Item Current consumption Controller communication unit GP-XBCD 20 mA or less Outputs 5 digits BCD, Polarity indication, VALID N-channel MOSFET open drain * Maximum sink current: 50 mA * A pplied voltage: 30 V DC or less (between output and GND) * Residual voltage: 1 V or less (at 50 mA sink current) Hold input Non-voltage contact or NPN open-collector transistor input * Low: 0 to 1 V * High: Open Material Weight Accessory Enclosure: ABS Net weight: 30 g approx. Mounting bracket [Stainless steel (SUS304)]: 1 pc. Note: Connects to the control device with GP-XBCC3 cable with connector on one end for BCD output unit (3 m 9.843 ft cable length, optional). Model No. Item Current consumption SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS STATIC CONTROL DEVICES Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 2) The sensing range is specified for the standard sensing object. 3) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. 4) For the flexible cable type, please contact our office. 5) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. 6) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand. BCD output unit SENSOR OPTIONS MEASUREMENT SENSORS PP ABS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PARTICULAR USE SENSORS 35 to 85 % RH, Storage: 35 to 85 % RH Voltage withstandability AREA SENSORS INDUCTIVE PROXIMITY SENSORS -10 to +55 C +14 to +131 F, Storage: -20 to +70 C -4 to +158 F Ambient humidity MICRO PHOTOELECTRIC SENSORS PRESSURE / FLOW SENSORS 3 (Industrial environment) Protection PHOTOELECTRIC SENSORS GP-XCOM LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 5 mA or less Material Enclosure: ABS Weight Net weight: 20 g approx. Selection Guide Mounting bracket [Stainless steel (SUS304)]: 1 pc. Laser Displacement Accessory Note: Each GP-XCOM is connected using a link cable for controller communication units (SL-F, optional). When GP-XCOM is used, controllers cannot communicate if their software versions are not compatible (Ver. 1.06 or earlier version with Ver 2.00 or later version). Check the software version and use the correct combination. Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products GP-X GP-A 1083 I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS PHOTOELECTRIC SENSORS I/O circuit diagram D1 MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS Tr6 Tr5 ZD6 Tr4 ZD5 Tr3 ZD4 Tr2 ZD3 2 3 5 6 7 4 17 PARTICULAR USE SENSORS 47 + - SENSOR OPTIONS Main circuit 5 k 5 k 5 k Alarm output 100 mA max. Load - 24 V DC 10 % ZD2 Tr3 100 mA max. Strobe output Interference prevention output + 100 mA max. Used for interference prevention function. 2 ZD3 Tr4 ZD4 Tr5 Output COM. 0V 9 Analog voltage output (-5 to +5 V) (Note) 8 For analog voltage output GND 47 + 10 11 ZD6 12 5 k Memory selection input 2 3 Comparative output HI 100 mA max. 5 Alarm output 100 mA max. 17 47 5 k 100 mA max. Comparative output GO 100 mA max. Strobe output Interference prevention Load output Used for interference 7 prevention function. Zero-set input Memory selection input 1 100 mA max. Comparative output LO 6 ZD5 Tr6 14 Timing input 5 k +24 V 5 k ENERGY MANAGEMENT SOLUTIONS 15 +24 V 5 k FA COMPONENTS 5 k Reset input 5 k Interference prevention input Used for interference prevention function. 16 *1 *2 *1 *1 Load Load 24 V DC 10 % Load 0V Analog voltage output (-5 to +5 V) (Note) 8 For analog voltage output GND 13 Input COM. (+24 V) *1 11 - Load 9 10 + *1 *1 *2 *1 Zero-set input Memory selection input 1 12 14 15 16 Input COM. 13 (0 V) Internal circuit Users' circuit Symbols ... D1: Reverse supply polarity protection diode ZD1 to ZD6: Surge absorption zener diode Tr1 to Tr6: NPN output transistor *1 Reset input Interference prevention input Used for interference prevention function. Users' circuit Note: Devices connected to the analog voltage output must have an input impedance set at 1 M or more. Symbols ... D1: Reverse supply polarity protection diode ZD1 to ZD6: Surge absorption zener diode Tr1 to Tr6: PNP output transistor *1 Non-voltage contact or NPN open-collector transistor Non-voltage contact or PNP open-collector transistor or Contact Displacement or * Zero-set input, reset input, memory selection input Low (0 to 4 V): Effective High (+V or open): Ineffective Digital Panel Controller Timing input Internal circuit Note: Devices connected to the analog voltage output must have an input impedance set at 1 M or more. Collimated Beam Sensors Metal-sheet Double-feed Detection Memory selection input 2 *1 5 k MACHINE VISION SYSTEMS Other Products Load ZD1 Tr2 Output COM. +24 V HUMAN MACHINE INTERFACES Magnetic Displacement Load 1 +24 V PLC Laser Displacement Comparative output HI 100 mA max. Tr1 +24 V LASER MARKERS Selection Guide 4 Load - 5 k STATIC CONTROL DEVICES UV CURING SYSTEMS 100 mA max. +V 18 +24 V SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS 47 Comparative output GO Terminal No. D1 1 Tr1 ZD2 I/O circuit diagram Terminal No. +V 18 Comparative ZD1 output LO Load INDUCTIVE PROXIMITY SENSORS WIRE-SAVING SYSTEMS PNP output type controller NPN output type controller Main circuit LASER SENSORS GP-X SERIES High Speed High Accuracy Eddy Current Type Digital Displacement Sensor *2 * Zero-set input, reset input, memory selection input Low (0 V or open): Ineffective High (+17 or +24 V): Effective *2 NPN open-collector transistor PNP open-collector transistor GP-X GP-A * Timing input Low (0 to 4 V): Effective High (+V or open): Ineffective * Timing input Low (0 V or open): Ineffective High (+17 to +24 V): Effective Memory selection input Memory No. Memory selection input Memory selection 1 Memory selection 2 Memory No. Memory selection 1 Memory selection 2 0 High High 0 Low 1 Low High 1 High Low Low 2 High Low 2 Low High 3 Low Low 3 High High High Speed High Accuracy Eddy Current Type Digital Displacement Sensor PRECAUTIONS FOR PROPER USE * Never use this product as a sensing device for personnel protection. * In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. * The sensor head and the controller are adjusted in order to conform to the default specification linearity. * In the event of replacing sensor heads, input the sensor head's characteristic code and conduct 3-point correction (calibration). * Should you use an extension cable, turn the sensor head cable length selection switch located on the back of the controller to "3 m + 7 m 9.843 ft + 22.966 ft". Then reintroduce the power supply and conduct 3-point correction (calibration). Conditions in use for CE conformity * This product is CE compliant and complies with EMC directives. EN 61000-6-2 is the applicable standard that covers immunities relating to use of this product, but in order to comply with this standard, the following conditions must be satisfied. Conditions * The controller should be connected less than 10 m 32.808 ft from the power supply. * The signal line to connect with the controller should be less than 30 m 98.425 ft. * A ferrite clamp must be mounted within 10 mm 0.394 in from connector fitted onto the GP-XBCC3 cable with connector on one end for BCD output units. Linearity in case of disc-shaped or cylindrical objects * In case the sensing object is disc-shaped or cylindrical, the linearity varies with the sensing object size. In the event the sensing object is larger than the sizes indicated in the table below, the linearity specification (within 0.3 % F.S.) is satisfied by performing zeroadjustment and span adjustment when in contact using the scaling function. Sensor head Iron disc o (mm) t: 1 mm in 0.039 in t Iron cylinder : 135 mm 5.315 in Disc diameter Cylinder diameter o (mm in) o (mm in) GP-X3SE 6 0.236 16 0.630 GP-X5SE 8 0.315 16 0.630 GP-X8S 12 0.472 50 1.969 GP-X10M 12 0.472 50 1.969 GP-X12ML 25 0.984 55 2.165 GP-X22KL 30 1.181 165 6.496 o (mm in) Mounting sensor head * The tightening torque should be under the value given below. * Make sure to use an M3 or smaller set screw having a cup-point. Set screw (M3 or less) A (Cup-point) Model No. GP-X3SE GP-X5SE GP-X8S A (mm in) 4 to 16 0.157 to 0.630 5 to 16 0.197 to 0.630 Tightening torque 0.1 N*m or less 0.44 N*m or less 0.58 N*m or less 1084 Refer to p.1595 for general precautions. B Attached toothed lock washer B Attached toothed lock washer B Attached toothed lock washer Mounting plate Mounting plate Mounting plate Model No. B (mm in) Tightening torque GP-X10M 7 0.276 or more 9.8 N*m or less GP-X12ML 14 0.551 or more 20 N*m or less GP-X22KL 20 0.787 or more (Note 1) 20 N*m or less * As metal around the sensor head may affect the sensing performance, pay attention to the following points. * Since the analog output may change if the sensor head is completely embedded in metal, keep the minimum distance specified in the table below. Sensor head D Metal GP-X5SE C (mm in) D (mm in) o10 o0.394 3 0.118 GP-X8S o18 o0.709 GP-X10M o14 o0.551 GP-X12ML o50 o1.969 14 0.551 GP-X22KL o50 o1.969 20 0.787 Mutual interference * If several sensor heads are mounted close together, some specifications may not be satisfied. Therefore, proceed with the interference prevention function enabled. The interference prevention function eliminates interference among sensors by alternating sensor oscillations. Contact our office for details about time charts etc. If not using the interference prevention function, leave a distance more than the values given below. E F Sensor head MICRO PHOTOELECTRIC SENSORS AREA SENSORS PRESSURE / FLOW SENSORS Distance from surrounding metal GP-X3SE PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Notes: 1) Without nut. If a nut is installed, the dimension will be 23.5 mm 0.926 in or more. 2) Mount such that the nuts do not protrude from the threaded portion. C FIBER SENSORS LASER SENSORS Mounting with nut INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS E (mm in) F (mm in) GP-X3SE 15 0.591 9 0.354 GP-X5SE 30 1.181 11 0.433 GP-X8S 40 1.575 15 0.591 Selection Guide GP-X10M 40 1.575 15 0.591 GP-X12ML 170 6.693 50 1.969 Laser Displacement GP-X22KL 200 7.874 200 7.874 Magnetic Displacement Contact Displacement Sensing range * The sensing range is specified for the standard sensing object [stainless steel (SUS304) / iron [Cold rolled carbon steel (SPCC)], 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in]. For sensing metals other than the standard sensing objects, use the correction coefficient stated below as a guideline. Verify with the actual sensor before using. Collimated Beam Sensors Metal-sheet Double-feed Detection Correction coefficient GP-X Sensor head Metal Mounting with set screw GP-X SERIES Stainless steel (SUS304), Iron Aluminum GP-X3SE GP-X10M GP-X5SE GP-X8S GP-X12ML GP-X22KL 1 0.5 approx. Others * After turning on the power, wait 15 min. or more [20 min.for the GP-XC3SE(-P) and GP-XC5SE(-P)] before usingthe product. The power supply circuit is not stable immediately after the power is turned on, and this may cause measurement values to be distorted. In addition, note that there will also be a muting period of approx. 2 sec. Digital Panel Controller Other Products GP-A 1085 FIBER SENSORS LASER SENSORS High Speed High Accuracy Eddy Current Type Digital Displacement Sensor GP-X SERIES DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. Controller PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Comparative output operation indicators (Orange / Green / Orange) 5-digit, dual numerical display (Orange / Green) AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Timing indicator (Green) 10 0.394 PRESSURE / FLOW SENSORS GP-X series INDUCTIVE PROXIMITY SENSORS SHIFT key SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Zero-set key MODE indicator (Orange) ENTER key MODE key Connector for RS-232C Sensor head cable length selection switch UP key Coaxial connector for sensor head connection DOWN key Panel cut-out dimensions 45 +0.6 0 1.772 +0.024 0 STATIC CONTROL DEVICES LASER MARKERS 45 +0.6 0 1.772 +0.024 0 PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS 44.5 1.752 48 1.890 PARTICULAR USE SENSORS SENSOR OPTIONS Terminal block (16.7) (0.657) 73 2.874 45 +0.6 0 1.772 +0.024 0 When mounted in series A = (48 x n - 2.5) +0.6 0 A = (1.890 x n - 0.098) +0.024 0 45 +0.6 0 1.772 +0.024 0 A Minimum 90 3.543 Minimum 90 3.543 FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Note: The panel thickness should be 1 to 5 mm 0.039 to 0.197 in. Minimum 100 3.937 Note: The panel thickness should be 1 to 2.5 mm 0.039 to 0.098 in. Selection Guide GP-X3SE Sensor head Laser Displacement Magnetic Displacement 17 0.669 Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Sensor head o2.5 o0.098 high frequency coaxial cable, 3 m 9.843 ft long 17 0.669 Coaxial connector for controller connection (6.2) (0.244) (o6.4) (o0.252) (o6.4) (o0.252) o3.8 o0.150 (17) (0.669) (25.7) (1.012) Digital Panel Controller Other Products GP-X GP-X5SE o2.5 o0.098 high frequency coaxial cable, 3 m 9.843 ft long Coaxial connector for controller connection GP-X8S (17) (0.669) (25.7) (1.012) o5.4 o0.213 Sensor head GP-X10M Sensor head GP-A o2.5 o0.098 high frequency coaxial cable, 3 m 9.843 ft long 17 0.669 (6.2) (0.244) o2.5 o0.098 high frequency coaxial cable, 3 m 9.843 ft long Coaxial connector for controller connection 14 0.551 17 0.669 (17) (0.669) (25.7) (1.012) Coaxial connecfor for controller connection (o6.4) (o0.252) (o6.4) (o0.252) o8 o0.315 (6.2) (0.244) (17) (0.669) (25.7) (1.012) Toothed lock washer (internal tooth) M10 x 1 0.039 o18 o0.709 Nut 3 0.118 High Speed High Accuracy Eddy Current Type Digital Displacement Sensor DIMENSIONS (Unit: mm in) GP-X12ML 7 0.276 (6.2) (0.244) 21 0.827 GP-X22KL o2.5 o0.098 high frequency coaxial cable, 3 m 9.843 ft long Coaxial connector for controller connection Sensor head 35 1.378 20 0.787 (6.2) (0.244) o2.5 o0.098 high frequency coaxial cable, 3 m 9.843 ft long 17 0.669 Coaxial connector for controller connection (17) (0.669) (25.7) (1.012) Toothed lock washer (internal tooth) M12 x 1 0.039 Nut 3.5 0.138 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS (o6.4) (o0.252) o10.1 o0.398 o21 o0.827 1086 The CAD data can be downloaded from our website. Sensor head 17 0.669 GP-X SERIES o22 o0.866 3.5 0.138 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS (17) (0.669) (o6.4) (25.7) (1.012) (o0.252) M12 x 1 0.039 Nut o21 o0.827 Toothed lock Diameter of washer toothed lock (internal tooth) washer ( GP-XBCD PRESSURE / FLOW SENSORS ) BCD output unit (Optional) Assembly dimensions with controller INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Mounting frame Connector for controller connection 40 1.575 STATIC CONTROL DEVICES Controller Mounting bracket BCD output unit LASER MARKERS Connector for BCD output (68) (2.677) 55 2.165 20 0.787 (8.5) (0.335) Panel thickness dimension 1 to 2.5 0.039 to 0.098 PLC HUMAN MACHINE INTERFACES (74.6) (2.937) GP-XCOM (27.8) (1.094) Connector for BCD output (68) (2.677) Cable with connector for BCD output unit Controller communication unit (Optional) Assembly dimensions with controller ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Laser Displacement Connector for communication Mounting frame Connector for controller connection 40 1.575 Mounting bracket Communication unit Terminator switch Controller (68) (2.677) 20 0.787 (8.5) (0.335) Panel thickness dimension 1 to 2.5 0.039 to 0.098 Communication cable Connector for communication MS-SS3MS-SS5MS-SS8 2-o3.5 o0.138 mounting holes A C B 4 0.157 4 0.157 8 0.315 16 0.630 Material: Nylon 66 4 0.157 D (68) (2.677) (74.6) (2.937) Sensor head mounting bracket (Optional) Model No. Symbol MS-SS3 MS-SS5 MS-SS8 A 16 0.630 18 0.709 20 0.787 B 9 0.354 10 0.394 11 0.433 C 6.3 0.248 8.3 0.327 10.3 0.406 D 4.9 0.193 6.1 0.240 6.5 0.256 Applicable sensor head model No. GP-X3SE GP-X5SE GP-X8S Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Terminator switch 55 2.165 Magnetic Displacement Digital Panel Controller Other Products GP-X GP-A