BURNDY Compression TWO HOLE HYLUGTM FLEX CONDUCTOR STANDARD BARREL COLOR CODE AND DIE INFORMATION BEVELED ENTRY INSPECTION WINDOW TYPES YA-L-2TC, YA-L-2TC-FX, YAV-L-2TC-FX CRIMP ELECTRO-TIN PLATED CABLE ACCOMMODATION For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. UL Listed 90 C, 600 Volts to 35 KV B C-64 COPPER COMPRESSION TERMINAL B B T T Fig. 1 Catalog Number YA8CL2TC10 YA8CL2TC10-45 YA8CL2TC10-90 YA8CL2TC14 YA8CL2TC14-45 YA8CL2TC14-90 YA8CL2TC14E1 YA8CL2TC14E1-45 YA8CL2TC14E1-90 YA8CL2TC14E2 YA8CL2TC14E2-45 YA8CL2TC14E2-90 YA8CL2TC38 YA8CL2TC38-45 YA8CL2TC38-90 YAV6C-L2TC10-FX YAV6C-L2TC10-FX-45 YAV6C-L2TC10-FX-90 YAV6C-L2TC10E2-FX YAV6C-L2TC10E2-FX-45 YAV6C-L2TC10E2-FX-90 YAV6C-L2TC10E4-FX YAV6C-L2TC10E4-FX-45 YAV6C-L2TC10E4-FX-90 YAV6C-L2TC10E9-FX YAV6C-L2TC10E9-FX-45 YAV6C-L2TC10E9-FX-90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG *** MM2 # 10 5/8 .41 1/4 5/8 .44 1/4 1 .44 1/4 3/4 .44 3/8 1 .58 # 10 5/8 .44 # 10 3/4 .48 # 10 11/16 .44 # 10 1/2 .48 37/24 #8 WELD ** 10 #8 AWG 61/24 ** #6 WELD #6 AWG 16 * Use PUADP-1 adaptor with "U" dies in Y46 HYPRESSTM. ** The MM2 conductor size referenced here is for both Class 2 and Class 5 conductor. *** The MM2 conductor sizes listed are the recommendations for Class 5 conductor. Figure Dimensions (B) (T) (L) 1.84 .44 .08 1.83 1.37 1.95 .44 .08 1.94 1.49 2.33 .44 .08 2.32 1.87 2.08 .44 .08 2.07 1.62 2.52 .44. .06 2.46 2.05 1.94 .50 .07 1.86 1.38 2.06 .50 .08 2.06 1.57 2.00 .50 .07 1.95 1.44 1.81 .50 .08 1.77 1.27 Fig. 3 Fig. 2 Conductor Stud Stud Hole Hole Tongue Size Spacing Width T Dieless (# of crimps) Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 Wire Color Die Strip Code Index Length MRC840 (1) MY29-3 (1) MY29-11 (1) Y8MRB-1 (1) Y2MR (1) Y1MR (1) W8CVT (1) W8CRT (1) X8CRT (1) W8CVT (1) W8CRT (1) X8CRT (1) U8CRT (1) Red 49 7/16 MRC840 (1) MY29-11 (1) Y2MR (1) Y644M (1) Y1MR (1) W5CVT (1) W5CRT (1) X5CRT (1) W5CVT (1) W5CRT (1) X5CRT (1) U5CRT (1) Blue 7 1/2 See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for "FX" connectors. For nest/indentor system contact factory. For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B TWO HOLE HYLUGTM FLEX CONDUCTOR STANDARD BARREL (Continued) T Fig. 1 Conductor Catalog Number YAV6C-L2TC14-FX YAV6C-L2TC14-FX-45 YAV6C-L2TC14-FX-90 YAV6C-L2TC14E2-FX YAV6C-L2TC14E2-FX-45 YAV6C-L2TC14E2-FX-90 YAV6C-L2TC14E1-FX YAV6C-L2TC14E1-FX-45 YAV6C-L2TC14E1-FX-90 YAV6C-L2TC516-FX YAV6C-L2TC516-FX-45 YAV6C-L2TC516-FX-90 YAV6C-L2TC38-FX YAV6C-L2TC38-FX-45 YAV6C-L2TC38-FX-90 YAV6C-L2NTC-FX YAV6C-L2NTC-FX-45 YAV6C-L2NTC-FX-90 YAV4C-L2NT10-FX YAV4C-L2NT10-FX-45 YAV4C-L2NT10-FX-90 YAV4C-L2NT10E1-FX YAV4C-L2NT10E1-FX-45 YAV4C-L2NT10E1-FX-90 YAV4C-L2TC14-FX YAV4C-L2TC14-FX-45 YAV4C-L2TC14-FX-90 YAV4C-L2TC14E2-FX YAV4C-L2TC14E2-FX-45 YAV4C-L2TC14E2-FX-90 YAV4C-L2TC14E1-FX YAV4C-L2TC14E1-FX-45 YAV4C-L2TC14E1-FX-90 YAV4C-L2TC516-FX YAV4C-L2TC516-FX-45 YAV4C-L2TC516-FX-90 YAV4C-L2TC38-FX YAV4C-L2TC38-FX-45 YAV4C-L2TC38-FX-90 YAV4C-L2NTC-FX YAV4C-L2NTC-FX-45 YAV4C-L2NTC-FX-90 YAV2C-L2TC14-FX YAV2C-L2TC14-FX-45 YAV2C-L2TC14-FX-90 YAV2C-L2TC14E2-FX YAV2C-L2TC14E2-FX-45 YAV2C-L2TC14E2-FX-90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG *** MM2 Stud Stud Hole Hole Tongue Size Spacing Width 1/4 5/8 .48 1/4 3/4 .48 1/4 1 .48 61/24 ** #6 WELD 16 #6 AWG 5/16 1 .52 3/8 1 .58 1/2 1-3/4 .83 # 10 5/8 .41 # 10 1 .41 1/4 5/8 .55 1/4 3/4 .55 91/24 105/24 #4 WELD 1/4 1 .55 5/16 1 .55 3/8 1 .58 1/2 1-3/4 .83 1/4 5/8 .68 1/4 3/4 .68 #4 AWG 125/24 150/24 #2 WELD #2 AWG 35 * Use PUADP-1 adaptor with "U" dies in Y46 HYPRESSTM. ** The 16 MM2 referenced here is for both Class 2 and Class 5 conductor. *** The MM2 conductor sizes listed are the recommendations for Class 5 conductor. B B T Figure Dimensions (B) (T) (L) 2.06 .50 .08 2.02 1.52 2.19 .50 .08 2.15 1.64 2.44 .50 .08 2.40 1.89 2.50 .50 .07 2.45 1.95 2.62 .50 .06 2.56 2.07 3.81 .50 .12 3.67 3.29 1.95 .50 .09 1.94 1.43 2.33 .50 .09 2.31 1.80 2.08 .50 .09 2.06 1.55 2.20 .50 .09 2.19 1.68 2.45 .50 .09 2.44 1.93 2.52 .50 .09 2.50 1.99 2.68 .50 .08 2.64 2.11 3.87 .50 .12 3.91 3.32 2.26 .63 .10 2.22 1.60 2.38 .63 .10 2.34 1.73 Dieless (# of crimps) T Fig. 2 Fig. 3 Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 Wire Color Die Strip Code Index Length C-65 MY29-11 (1) Y2MR (1) Y644M Y1MR (1) W5CVT (1) W5CRT (1) X5CRT (1) W5CVT (1) W5CRT (1) X5CRT (1) U5CRT (1) Blue 7 7/16 W4CVT (1) W4CRT (1) X4CRT (1) W4CVT (1) W4CRT (1) X4CRT (1) U4CRT (1) Gray 8 1/2 W2CVT (1) W2CRT (1) X2CRT (1) W2CVT (1) W2CRT (1) X2CRT (1) U2CRT (1) Brown 10 11/16 MY29-11 (1) Y2MR (2) Y644M (1) Y1MR (2) See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for "-FX" connectors. For nest/indentor system contact factory. For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B TWO HOLE HYLUGTM FLEX CONDUCTOR STANDARD BARREL (Continued) T Fig. 1 Conductor Catalog Number C-66 YAV2C-L2TC14E1-FX YAV2C-L2TC14E1-FX-45 YAV2C-L2TC14E1-FX-90 YAV2C-L2TC516-FX YAV2C-L2TC516-FX-45 YAV2C-L2TC516-FX-90 YAV2C-L2TC38-FX YAV2C-L2TC38-FX-45 YAV2C-L2TC38-FX-90 YAV2C-L2NTC-FX YAV2C-L2NTC-FX-45 YAV2C-L2NTC-FX-90 YAV1C-L2TC14-FX YAV1C-L2TC14-FX-45 YAV1C-L2TC14-FX-90 YAV1C-L2TC14E1-FX YAV1C-L2TC14E1-FX-45 YAV1C-L2TC14E1-FX-90 YAV1C-L2TC14E2-FX YAV1C-L2TC14E2-FX-45 YAV1C-L2TC14E2-FX-90 YAV1C-L2TC516-FX YAV1C-L2TC516-FX-45 YAV1C-L2TC516-FX-90 YAV1C-L2TC38-FX YAV1C-L2TC38-FX-45 YAV1C-L2TC38-FX-90 YAV1C-L2NTC-FX YAV1C-L2NTC-FX-45 YAV1C-L2NTC-FX-90 YAV25-L2TC14-FX YAV25-L2TC14-FX-45 YAV25-L2TC14-FX-90 YAV25-L2TC14E2-FX YAV25-L2TC14E2-FX-45 YAV25-L2TC14E2-FX-90 YAV25-L2TC516E2-FX YAV25-L2TC516E2-FX-45 YAV25-L2TC516E2-FX-90 YAV25-L2TC516-FX YAV25-L2TC516-FX-45 YAV25-L2TC516-FX-90 YAV25-L2TC38-FX YAV25-L2TC38-FX-45 YAV25-L2TC38-FX-90 YAV25-L2TC12E1-FX YAV25-L2TC12E1-FX-45 YAV25-L2TC12E1-FX-90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG *** MM2 150/24 #2 WELD Stud Stud Hole Hole Tongue Size Spacing Width 1/4 1 .68 5/16 1 .68 35 #2 AWG 3/8 1 .68 1/2 1-3/4 .83 1/4 5/8 .75 1/4 1 .75 1/4 3/4 .75 175/24 225/24 #1 WELD 5/16 1 .75 3/8 1 .75 1/2 1-3/4 .83 #1 AWG 1/4 5/8 .83 1/4 3/4 .83 5/16 3/4 .83 5/16 1 . .83 3/8 1 .83 1/2 1 .83 275/24 1/0 WELD 1/0 AWG 50 * Use PUADP-1 adaptor with "U" dies in Y46 HYPRESSTM. *** The MM2 conductor sizes listed are the recommendations for Class 5 conductor. See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for "-FX" connectors. For nest/indentor system contact factory. B B T Figure Dimensions (B) (T) (L) 2.63 .63 .10 2.60 1.98 2.71 .63 .10 2.70 2.04 2.82 .63 .10 2.78 2.17 4.07 .63 .08 3.93 3.34 2.35 .69 .12 2.32 1.64 2.71 .69 .12 2.69 2.00 2.47 .69 .12 2.45 1.76 2.79 .69: .12 2.76 2.08 2.91 .69 .12 2.88 2.20 4.10 .69 .11 4.04 3.38 2.39 .69 .12 2.35 1.66 2.51 .69 .12 2.47 1.79 2.57 .69 .12 2.53 1.85 2.82 .69 .12 2.78 2.10 2.95 .69 .12 2.91 2.23 3.20 .69 .12 3.16 2.48 Dieless (# of crimps) T Fig. 2 Fig. 3 Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 MY29-11 (1) Y2MR (2) Y644M (1) Y1MR (2) Wire Color Die Strip Code Index Length W2CVT (1) W2CRT (1) X2CRT (1) W2CVT (1) W2CRT (1) X2CRT (1) U2CRT (1) Brown 10 11/16 W1CVT (1) W1CRT-1 (1) X1CRT-1 (1) W1CVT (1) W1CRT-1 (1) X1CRT-1 (1) U1CRT-1 (1) Green 11 11/16 W25VT (2) W25RT (2) X25RT (2) W25VT (2) W25RT (2) X25RT (2) U25RT (1) Pink 12 11/16 MY29-11 (1) Y644M (1) For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B TWO HOLE HYLUGTM FLEX CONDUCTOR STANDARD BARREL (Continued) T Fig. 1 Conductor Catalog Number YAV25-L2NTC-FX YAV25-L2NTC-FX-45 YAV25-L2NTC-FX-90 YAV26-L2TC14-FX YAV26-L2TC14-FX-45 YAV26-L2TC14-FX-90 YAV26-L2TC14E2-FX YAV26-L2TC14E2-FX-45 YAV26-L2TC14E2-FX-90 YAV26-L2TC516-FX YAV26-L2TC516-FX-45 YAV26-L2TC516-FX-90 YAV26-L2TC38-FX YAV26-L2TC38-FX-45 YAV26-L2TC38-FX-90 YAV26-L2TC12E1-FX YAV26-L2TC12E1-FX-45 YAV26-L2TC12E1-FX-90 YAV26-L2NTC-FX YAV26-L2NTC-FX-45 YAV26-L2NTC-FX-90 YAV27-L2TC14-FX YAV27-L2TC14-FX-45 YAV27-L2TC14-FX-90 YAV27-L2TC38-FX YAV27-L2TC38-FX-45 YAV27-L2TC38-FX-90 YAV27-L2NTC-FX YAV27-L2NTC-FX-45 YAV27-L2NTC-FX-90 YAV27-L2NTC516-FX YAV27-L2NTC516-FX-45 YAV27-L2NTC516-FX-90 YAV28-L2TC14E2-FX YAV28-L2TC14E2-FX-45 YAV28-L2TC14E2-FX-90 YAV28-L2TC14-FX YAV28-L2TC14-FX-45 YAV28-L2TC14-FX-90 YAV28-L2TC516-FX YAV28-L2TC516-FX-45 YAV28-L2TC516-FX-90 YAV28-L2TC38-FX YAV28-L2TC38-FX-45 YAV28-L2TC38-FX-90 YAV28-L2NTC-FX YAV28-L2NTC-FX-45 YAV28-L2NTC-FX-90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG 275/24 1/0 AWG 1/0 WELD *** MM2 Stud Stud Hole Hole Tongue Size Spacing Width 50 1/2 1-3/4 .83 1/4 5/8 .93 1/4 3/4 .93 5/16 1 .93 325/24 2/0 WELD 70 2/0 AWG 3/8 1 .93 1/2 1 .93 1/2 1-3/4 .93 1/4 5/8 1.03 3/8 1 1.03 450/24 3/0 WELD 95 3/0 AWG 1/2 1-3/4 1.03 5/16 1 1.03 1/4 3/4 1.12 1/4 5/8 1.12 5/16 1 1.12 3/8 1 1.12 1/2 1-3/4 1.20 550/24 ** 4/0 WELD 120 4/0 AWG * Use PUADP-1 adaptor with "U" dies in Y46 HYPRESSTM. ** The 120 MM2 referenced here is for both Class 2 and Class 5 conductor. *** The MM2 conductor sizes listed are the recommendations for Class 5 conductor. B B T Figure Dimensions (B) (T) (L) 4.14 .69 .12 4.10 3.41 2.56 .81 .13 2.49 1.70 2.68 .81 .13 2.61 1.83 2.99 .81 .13 2.93 2.14 3.12 .81 .13 3.05 2.26 3.37 .81 .13 3.30 2.51 4.31 .81 .13 4.24 3.45 2.83 1.00 .14 2.69 1.74 3.35 1.00 .14 3.23 2.30 4.54 1.00 .14 4.42 3.49 3.22 1.00 .14 3.11 2.18 2.91 1.03 .15 2.80 1.86 2.86 1.03 .15 2.74 1.78 3.30 1.03 .15 3.18 2.22 3.43 1.03 .15 3.30 2.34 4.18 1.03 .15 4.05 3.09 Dieless (# of crimps) T Fig. 2 Fig. 3 Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 Wire Color Die Strip Code Index Length C-67 W25VT (2) W25VT (2) U25RT (1) Pink 12 11/16 W26VT (2) W26RT (2) X26RT (2) W26VT (2) W26RT (2) X26RT (2) U26RT (1) Black 13 13/16 W27VT (2) W27RT (2) X27RT (3) W27VT (2) W27RT (2) X27RT (3) U27RT (1) Orange 14 1 W28VT (2) W28RT (2) X28RT (3) W28VT (2) W28RT (2) X28RT (3) U28RT (1) Purple 15 1-1/16 MY29-11 (1) Y644M (1) See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for "-FX" connectors. For nest/indentor system contact factory. For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B TWO HOLE HYLUGTM FLEX CONDUCTOR STANDARD BARREL (Continued) T Fig. 1 Conductor Fig *** Catalog Number # AWG MM2 1 C-68 YAV28-L2TC14E2 YAV28-L2TC14E2-45 2 YAV28-L2TC14E2-90 3 YAV28-L2NT38-FX 1 YAV28-L2NT38-FX-45 2 YAV28-L2NT38-FX-90 3 550/24 YAV28-LTC12E1-FX 1 ** YAV28-LTC12E1-FX-45 2 4/0 WELD YAV28-LTC12E1-FX-90 3 120 YAV28-L2TC12-FX 1 4/0 AWG YAV28-L2TC12-FX-45 2 YAV28-L2TC12-FX-90 3 YAV28-L2NTC-FX 1 YAV28-L2NTC-FX-45 2 YAV28-L2NTC-FX-90 3 YAV29-L2TC14E2-FX 1 YAV29-L2TC14E2-FX-45 2 YAV29-L2TC14E2-FX-90 3 YAV29-L2TC14-FX 1 YAV29-L2TC14-FX-45 2 YAV29-L2TC14-FX-90 3 YAV29-L2TC516-FX 1 YAV29-L2TC516-FX-45 2 YAV29-L2TC516-FX-90 3 YAV29-L2TC38-FX 1 YAV29-L2TC38-FX-45 2 550/24 YAV29-L2TC38-FX-90 3 YAV29-L2NTC-FX 1 4/0 WELD YAV29-L2NTC-FX-45 2 YAV29-L2NTC-FX-90 3 YAV29-L2NT38-FX 1 YAV29-L2NT38-FX-45 2 YAV29-L2NT38-FX-90 3 YAV29-LTC12E1-FX 1 YAV29-LTC12E1-FX-45 2 YAV29-LTC12E1-FX-90 3 YAV29-L2TC12-FX 1 YAV29-L2TC12-FX-45 2 YAV29-L2TC12-FX-90 3 YA30-L2TC38-FX 1 YA30-L2TC38-FX-45 2 YA30-L2TC38-FX-90 3 YA30-L2TC12-FX 1 250 FLEX YA30-L2TC12-FX-45 2 CLASS G 259 STR YA30-L2TC12-FX-90 3 CLASS H 427 STR YA30-L2NTC-FX 1 YA30-L2NTC-FX-45 2 YA30-L2NTC-FX-90 3 Stud Stud Hole Hole Tongue Size Spacing Width 1/4 3/4 1.14 3/8 1 .94 1/2 1 1.14 1/2 1-1/4 1.14 1/2 1-3/4 1.14 1/4 3/4 1.12 1/4 5/8 1.12 5/16 1 1.12 3/8 1 1.12 1/2 1-3/4 1.20 3/8 1 .94 1/2 1 1.14 1/2 1-1/4 1.14 3/8 1 1.20 1/2 1-1/4 1.20 1/2 1-3/4 1.20 * Use PUADP-1 adaptor with "U" dies in Y46 HYPRESSTM. ** The 120 MM2 referenced here is for both Class 2 and Class 5 conductor. *** The MM2 conductor sizes listed are the recommendations for Class 5 conductor. B B T Figure Dimensions (B) (T) (L) 2.99 1.03 .15 2.87 1.90 3.44 1.03 .15 3.36 2.36 3.68 1.03 .15 3.55 2.59 3.93 1.03 .15 3.80 2.84 4.62 1.03 .15 4.49 3.53 2.91 1.03 .16 2.80 1.86 2.86 1.03 .16 2.74 1.78 3.30 1.03 .16 3.18 2.22 3.43 1.03 .16 3.30 2.34 4.18 1.03 .16 4.05 3.09 3.44 1.03 .16 3.36 2.36 3.68 1.03 .16 3.55 2.59 3.93 1.03 .16 3.80 2.84 3.45 1.03 .16 3.36 2.37 3.95 1.03 .16 3.86 2.87 4.63 1.03 .16 4.55 3.56 Dieless (# of crimps) T Fig. 2 Fig. 3 Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 Wire Color Die Strip Code Index Length MY29-11 (1) Y644M (1) W28VT (2) W28RT (2) X28RT (3) W28VT (2) W28RT (2) X28RT (3) U28RT (1) Purple 15 1-1/16 Y644M (1) W29VT (2) X29RT (4) W29VT (2) W29RT (2) X29RT (4) U29RT (1) Yellow 16 1-1/16 Y644M (1) W29VT (2) X29RT (4) W29VT (2) W29RT (2) X29RT (4) U29RT (1) Yellow 16 1-1/16 See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for "-FX" connectors. For nest/indentor system contact factory. For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B TWO HOLE HYLUGTM FLEX CONDUCTOR STANDARD BARREL (Continued) T Catalog Number YA31-L2TC38-FX YA31-L2TC38-FX-45 YA31-L2TC38-FX-90 YA31-L2TC12-FX YA31-L2TC12-FX-45 YA31-L2TC12-FX-90 YA31-L2NTC-FX YA31-L2NTC-FX-45 YA31-L2NTC-FX-90 YA31-L2NTC38-FX YA31-L2NTC38-FX-45 YA31-L2NTC38-FX-90 YA32-L2TC38-FX YA32-L2TC38-FX-45 YA32-L2TC38-FX-90 YA32-L2NTC-FX YA32-L2NTC-FX-45 YA32-L2NTC-FX-90 YA34-L2TC38-FX YA34-L2TC38-FX-45 YA34-L2TC38-FX-90 YA34-L2TC12-FX YA34-L2TC12-FX-45 YA34-L2TC12-FX-90 YA34-L2NTC-FX YA34-L2NTC-FX-45 YA34-L2NTC-FX-90 YA34-L2TC516-FX YA34-L2TC516-FX-45 YA34-L2TC516-FX-90 YA34-L2NT38-FX YA34-L2NT38-FX-45 YA34-L2NT38-FX-90 YA34-L2NTC38-FX YA34-L2NTC38-FX-45 YA34-L2NTC38-FX-90 YA36-L2TC38-FX YA36-L2TC38-FX-45 YA36-L2TC38-FX-90 YA36-L2NTC-FX YA36-L2NTC-FX-45 YA36-L2NTC-FX-90 YA38-L2TC38-FX YA38-L2TC38-FX-45 YA38-L2TC38-FX-90 YA38-L2TC12-FX YA38-L2TC12-FX-45 YA38-L2TC12-FX-90 AWG *** MM2 Stud Stud Hole Hole Tongue Size Spacing Width 3/8 250 FLEX 637/24 1 1.29 1/2 1-1/4 1.29 150 1/2 1-3/4 1.29 CLASS I, K, M 3/8 1-3/4 1.29 3/8 775/24 1 1.38 185 313.1 kcmil 1/2 1-3/4 1.38 3/8 1 1.52 1/2 1-1/4 1.52 373.7 kcmil 1/2 1-3/4 1.52 925/24 240 (350 MCM NOM) 5/16 1 1.55 3/8 1 .96 3/8 1-3/4 1.55 3/8 1100/24 1 1.72 444.4 kcmil 535.3 kcmil 1325/24 300 (500 MCM NOM) 1/2 1-3/4 1.72 3/8 1 1.81 1/2 1-1/4 1.81 * Use PUADP-1 adaptor with "U" dies in Y46 HYPRESSTM. *** The MM2 conductor sizes listed are the recommendations for Class 5 conductor. See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for "-FX" connectors. For nest/indentor system contact factory. T Fig. 1 Conductor Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 B B T Figure Dimensions (B) (T) (L) 3.51 1.06 .18 3.43 2.41 4.01 1.06 .18 3.93 2.91 4.70 1.06 .18 4.62 3.60 4.26 1.06 .18 4.18 3.16 3.69 1.19 .19 3.59 2.45 4.88 1.19 .19 4.78 3.64 3.88 1.27 .23 3.81 2.54 4.38 1.27 .23 4.31 3.04 5.06 1.27 .23 5.00 3.73 3.75 1.27 .23 3.69 2.42 3.88 1.27 .23 3.81 2.54 4.63 1.27 .23 4.56 3.29 4.24 1.38 .27 4.21 2.81 5.24 1.38 .27 5.21 3.81 4.35 1.45 .27 4.30 2.84 4.67 1.45 .27 4.61 3.16 Dieless (# of crimps) Fig. 2 Fig. 3 Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 Wire Color Die Strip Code Index Length C-69 W30VT (2) W30VT (2) W30RT (2) U30RT (2) White 17 1-1/8 W31VT (2) W31VT (2) W31RT (2) U31RT (2) Red 18 1-1/4 W32VT (2) W32VT (2) W32RT (2) U32RT (2) Blue 19 1-5/16 - - U34RT (2) - - U38XRT (2) Y644M (1) For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. Brown 20 1-7/16 Pink L99 1-7/16 BURNDY Compression B TWO HOLE HYLUGTM FLEX CONDUCTOR STANDARD BARREL (Continued) T AWG *** MM2 Stud Stud Hole Hole Tongue Size Spacing Width 1/2 1-3/4 1.81 535.3 kcmil 1325/24 5/16 1 1.84 300 3/8 (500 MCM NOM) 1 1.63 1/2 1-3/4 1.63 600 kcmil - 1/2 1-3/4 1.91 1/2 1-3/4 1.95 646 kcmil 400 3/8 1 1.98 1600/24 1/2 1-3/4 1.63 3/8 1 2.19 1/2 1-3/4 2.19 5/8 1-1/2 2.19 777.7 kcmil 1925/24 500 1/2 1-1/4 2.19 (750 MCM NOM) 1/2 1-1/2 2.19 3/8 1 1.63 1/2 1-3/4 1.63 * Use PUADP-1 adaptor with "U" dies in Y46 HYPRESSTM. *** The MM2 conductor sizes listed are the recommendations for Class 5 conductor. See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for "-FX" connectors. For nest/indentor system contact factory. T Fig. 1 Conductor Fig Catalog Number # C-70 YA38-L2NTC-FX 1 YA38-L2NTC-FX-45 2 YA38-L2NTC-FX-90 3 YA38-L2TC516-FX 1 YA38-L2TC516-FX-45 2 YA38-L2TC516-FX-90 3 YA38-L2NT38-FX 1 YA38-L2NT38-FX-45 2 YA38-L2NT38-FX-90 3 YA38-L2NNT-FX 1 YA38-L2NNT-FX-45 2 YA38-L2NNT-FX-90 3 YA39-L2NTC-FX 1 YA39-L2NTC-FX-45 2 YA39-L2NTC-FX-90 3 YA40-L2NTC-FX 1 YA40-L2NTC-FX-45 2 YA40-L2NTC-FX-90 3 YA40-L2TC38-FX 1 YA40-L2TC38-FX-45 2 YA40-L2TC38-FX-90 3 YA40-L2NNT-FX 1 YA40-L2NNT-FX-45 2 YA40-L2NNT-FX-90 3 YA44-L2TC38-FX 1 YA44-L2TC38-FX-45 2 YA44-L2TC38-FX-90 3 YA44-L2NTC-FX 1 YA44-L2NTC-FX-45 2 YA44-L2NTC-FX-90 3 YA44-L2TC58-FX 1 YA44-L2TC58-FX-45 2 YA44-L2TC58-FX-90 3 YA44-L2TC12-FX 1 YA44-L2TC12-FX-45 2 YA44-L2TC12-FX-90 3 YA44-L2TC12E3-FX 1 YA44-L2TC12E3-FX-45 2 YA44-L2TC12E3-FX-90 3 YA44-L2NT38-FX 1 YA44-L2NT38-FX-45 2 YA44-L2NT38-FX-90 3 YA44-L2NNT-FX 1 YA44-L2NNT-FX-45 2 YA44-L2NNT-FX-90 3 B B T Figure Dimensions (B) (T) (L) 5.35 1.45 .27 5.30 3.84 4.04 1.45 .27 3.98 2.53 4.35 1.45 .27 4.30 2.84 5.35 1.45 .27 5.30 3.84 5.36 1.42 .27 5.31 3.87 5.38 1.42 .30 5.38 3.91 4.28 1.42 .30 4.20 2.72 5.38 1.42 .30 5.38 3.91 4.74 1.65 .33 4.71 3.02 5.74 1.65 .33 5.71 4.02 5.55 1.65 .33 5.52 3.83 5.05 1.65 .33 5.02 3.33 5.30 1.65 .33 5.27 3.58 4.74 1.65 .33 4.71 3.02 5.74 1.65 .33 5.71 4.02 Dieless (# of crimps) Fig. 2 Fig. 3 Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 Wire Color Die Strip Code Index Length - - U38XRT (2) Pink L99 1-7/16 - - U38RT (2) Purple 23 - - U39RT (2) Black - - U44XRT (2) Yellow L115 1-5/8 1-3/8 24 1-5/16 Y644M (1) For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.