Embedded Power for Business-Critical Continuity Rev. 2.16.09_115 PTH12010 Series of 6 PTH12010 12 Vin Single Output Total Power: # of Outputs: 66W Single Specifications Input Special Features Input voltage range: (See Note 3) 10.8 - 13.2 Vdc * 12 A output current * 12 V input voltage * Wide-output voltage adjust * 1.2 Vdc to 5.5 Vdc for suffix `W' and 0.8 Vdc to 1.8 Vdc for suffix `L' * Auto-trackTM sequencing* * Margin up/down controls * Efficiencies up to 94% * Output ON/OFF inhibit * Output voltage sense * Point-of-Load-Alliance (POLA) compatible * Available RoHS compliant * 2 Year Warranty Input current: No load 10 mA typ. Remote ON/OFF: (See Note 1) Positive logic Safety * UL/cUL CAN/CSA-C22.2 No. 60950-1-03/UL 60950-1, File No. E174104 * TUV Product Service (EN60950) Certificate No. B 04 06 38572 044 * CB Report and Certificate to IEC60950, Certificate No. US/8292/UL Start-up time: 1 V/ms Undervoltage lockout: 9.0 - 9.5 V typ. Track input voltage: Pin 8 (See Note 6) 0.3 Vin Suffix `-W' Suffix `-L' 1.2 - 5.5 Vdc 0.8 - 1.8 Vdc Output Voltage adjustability: (See Note 4) Setpoint accuracy: 2.0% Vo Line regulation: 10 mV typ. Load regulation: 12 mV typ. Total regulation: 3.0% Vo Minimum load: 0A Ripple and noise: 20 MHz bandwidth 25 mV pk-pk Temperature co-efficient: -40 C to +85 C 0.5% Vo Transient response: (See Note 5) 70 s recovery time Margin adjustment: 5.0% Vo Overshoot/undershoot 100 mV All specifications are typical at nominal input, full load at 25 C unless otherwise stated Cin = 560 F, Cout = 0 F *Auto-trackTM is a trade mark of Texas Instruments Embedded Power for Business-Critical Continuity Rev. 2.16.09_115 PTH12010 Series of 6 EMC Characteristics Electrostatic discharge: EN61000-4-2, IEC801-2 Conducted immunity: EN61000-4-6 Radiated immunity: EN61000-4-3 General Specifications Efficiency: See tables on page 3 Insulation voltage: Non-Isolated Switching frequency: Suffix `-W' Suffix `-L' 300 kHz to 400 kHz 200 kHz to 300 kHz Approvals and standards: EN60950, UL/cUL60950 Material flammability: UL94V-0 Dimensions: (L x W x H) Weight: MTBF 34.80 x 15.75 x 9.00 mm 1.370 x 0.620 x 0.354 in 5g (0.18 oz) Telcordia SR-332 7,092,000 hours Environmental Specifications Thermal performance: Operating ambient, temperature Non-operating -40 C to +85 C -40 C to +125 C MSL (`Z' suffix only) JEDEC J-STD-020C Level 3 Protection Short circuit: Auto reset 20 A typ. Embedded Power for Business-Critical Continuity Rev. 2.16.09_115 PTH12010 Series of 6 Ordering Information Output Power (max) Input Voltage Output Voltage 66 W 10.8 - 13.2 Vdc 66 W 10.8 - 13.2 Vdc Output Currents Min Max Efficiency (max) 0.8 - 1.8 Vdc 0A 12 A 89% 10 mV 12 mV PTH12010L 1.2 - 5.5 Vdc 0A 12 A 94% 10 mV 12 mV PTH12010W Part Number System with Options Regulation Line Load M odel Numbers (8, 9) PTH12010WAST Product Family Point of Load Alliance Compatible Packaging Options No Suffix = Trays T = Tape and Reel (7) Input Voltage 12 = 12 V Mounting Option (8) D = Horizontal Through-Hole (RoHS 6/6) H = Horizontal Through-Hole (RoHS 5/6) S = Surface-Mount Solder Ball (RoHS 5/6) Z = Surface-Mount Solder Ball (RoHS 6/6) Output Current 01 = 12 A Pin Option A = Through-Hole Std. Pin Length (0.140") A = Surface-Mount Tin/Lead Solder Ball Mechanical Package Always 0 Output Voltage Code W = Wide, L = Low Voltage Output Voltage Adjustment of the PTH12010 Series The ultra-wide output voltage trim range offers major advantages to users who select the PTH12010. It is no longer necessary to purchase a variety of modules in order to cover different output voltages. The output voltage can be trimmed in a range of 1.2 V to 5.5 V for suffix `W' and 0.8 Vdc to 1.8 Vdc for suffix `L'. When the PTH12010 converter leaves the factory the output has been adjusted to the default voltage of 1.2 V for the PTH12010W and 0.8 V for PTH12010L. Efficiency Table - PTH12010W (Io = 8 a) Output Voltage Efficiency Vo = 5.0 V 94% Vo = 3.3 V 93% Vo = 2.5 V 91% 2 Vo = 2.0 V 90% 3 Vo = 1.8 V 89% 4 Vo = 1.5 V 88% Vo = 1.2 V 86% Efficiency Table - PTH12010L (Io = 8 a) Output Voltage Efficiency Vo = 1.8 V 89% Vo = 1.5 V 88% Vo = 1.2 V 86% Vo = 1.0 V 84% Vo = 0.8 V 82% Notes 1 5 6 7 8 9 Remote ON/OFF. Positive Logic ON: Pin 3 open; or V > Vin - 0.5 V OFF: Pin 3 GND; or V < 0.8 V (min - 0.2 V). See Figures 1, 2 and 3 for safe operating curves for the PTH12010W and Figures 6 and 7 for PTH12010L. A 560 F electrolytic input capacitor is required for proper operation. The capacitor must be rated for a minimum of 800 mA rms of ripple current. An external output capacitor is not required for basic operation. Adding 330 F of distributed capacitance at the load will improve the transient response. 1 A/s load step, 50 to 100% Iomax, Cout = 330 F. If utilized Vout will track applied voltage by 0.3 V (up to Vo set point). Tape and reel packaging only available on the surface-mount versions. To order Pb-free (RoHS compatible) surface-mount parts replace the mounting option `S' with `Z', e.g. PTH12010WAZ. To order Pb-free (RoHS compatible) through-hole parts replace the mounting option `H' with `D', e.g. PTH12010WAD. NOTICE: Some models do not support all options. Please contact your local Emerson Network power representative or use the on-line model number search tool at http://www.PowerConversion.com to find a suitable alternative. Embedded Power for Business-Critical Continuity Rev. 2.16.09_115 PTH12010 Series of 6 90 90 80 80 TEMPERATURE (C) TEMPERATURE (C) PTH12010W Characteristic Data 70 60 Nat conv 100 LFM 200 LFM 400 LFM 50 40 70 60 50 40 30 20 Nat conv 100 LFM 200 LFM 400 LFM 30 0 2 4 6 8 10 20 12 0 2 OUTPUT CURRENT (A) 4 6 8 10 12 OUTPUT CURRENT (A) Figure 2 - Safe Operating Area Vin = 12 V, Output Voltage = 3.3 V (See Note A) Figure 1 - Safe Operating Area Vin = 12 V, Output Voltage = 5 V (See Note A) 100 80 90 70 60 EFFICIENCY (%) TEMPERATURE (C) 90 Nat conv 100 LFM 200 LFM 400 LFM 50 40 70 1.5V 60 1.2V 50 30 20 Vout 5.0V 3.3V 2.5V 2.0V 1.8V 80 40 0 2 4 6 8 10 12 OUTPUT CURRENT (A) 0 2 4 6 8 10 12 OUTPUT CURRENT (A) Figure 3 - Safe Operating Area Vin = 12 V, Output Voltage 1.8 V (See Note A) Figure 4 - Efficiency vs Load Current Vin = 12 V (See Note B) Track Margin Down Margin Up Notes 10 9 8 1 A 7 B PTH12010 (Top View) Vin 3 Inhibit + Vout 6 2 Cin 560F (Required) 4 5 Vo Sense RSET 1%, 0.1W (Required) + Cout 330F (Optional) GND GND Figure 5 - Standard Application L O A D SOA curves represent the conditions at which internal components are within the Emerson Network Power derating guidelines. Characteristic data has been developed from actual products tested at 25 C. This data is considered typical data for the converter. Embedded Power for Business-Critical Continuity Rev.Rev.mm.dd.yy 2.16.09_115 short PTH12010 title of product Series of 6x 90 100 80 90 70 60 EFFICIENCY (%) TEMPERATURE (C) PTH12010L Characteristic Data 100 LFM Nat conv 50 40 30 20 70 60 50 0 2 4 6 8 Vout 1.8V 1.5V 1.2V 1.0V 0.8V 80 10 0 2 4 6 8 10 12 OUTPUT CURRENT (A) OUTPUT CURRENT (A) Figure 7 - Efficiency vs Load Current Vin = 12 V (See Note B) Figure 6 - Safe Operating Area Vin = 12 V, Output Voltage 1.8 V (See Note A) Track Margin Down Margin Up 10 9 8 1 7 PTH12010 (Top View) Vin 3 Inhibit + Vout 6 2 Cin 560F (Required) 4 5 Vo Sense RSET 1%, 0.1W (Required) + Cout 330F (Optional) L O A D GND GND Figure 8 - Standard Application Notes A B SOA curves represent the conditions at which internal components are within the Emerson Network Power derating guidelines. Characteristic data has been developed from actual products tested at 25 C. This data is considered typical data for the converter. Embedded Power for Business-Critical Continuity Mechanical Drawings 1.370 (34.80) 0.060 (1.52) 1 0.060 (1.52) 0.625 (15.88) 8 9 10 o0.040 (1.02) 5 Places 0.070 (1.78) (Standoff Shoulder) Lowest Component 0.010 min. (0.25) Bottom side Clearance 6 5 4 3 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 7 0.620 0.500 (15.75) (12.70) 2 Americas 0.140 (3.55) 0.125 (3.18) 0.125 (3.18) 0.375 (9.52) Rev. 2.16.09_115 PTH12010 Series of 6 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) TOP VIEW Host Board 0.350 (8.89) MAX. Dimensions in Inches (mm) Tolerances (unless otherwise specified) 2 Places 0.030 ( 0.76) 3 Places 0.010 ( 0.25) SIDE VIEW 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: Figure 9 - Plated Through-Hole www.PowerConversion.com techsupport.embeddedpower @emerson.com 1.370 (34.80) 0.125 (3.18) 0.125 (3.18) 0.375 (9.52) 0.060 (1.52) 1 10 0.060 (1.52) 0.625 (15.88) 9 0.350 (8.89) max.* 7 8 *After solder reflow on customer board Solder Ball o0.040 (1.02) 10 Places 0.500 0.620 (12.70) (15.75) Lowest Component 0.010 min. (0.25) Bottom side Clearance 2 3 4 6 5 SIDE VIEW TOP VIEW Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Host Board Embedded Power Monitoring Dimensions in Inches (mm) Tolerances (unless otherwise specified) 2 Places 0.030 ( 0.76) 3 Places 0.010 ( 0.25) Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Figure 10 - Surface-Mount Pin Connections While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Pin Connections cont. Pin No. Function Pin No. Function Pin 1 Ground Pin 6 Vout Pin 2 Vin Pin 7 Ground Pin 3 Inhibit* Pin 8 Track Pin 4 Vo adjust Pin 9 Margin down* Pin 5 Vo sense Pin 10 Margin up* Services Surge Protection EmersonNetworkPower.com * Denotes negative logic: Open = Normal operation Ground = Function active Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2008 Emerson Electric Co.