Operator Interfaces OI Touchscreen Family Operator Interface Touchscreen Family PLCs Smart design to fit your needs Operator Interfaces From the large 12.1" TFT LCD Screen, to the compact 4.6" STN LCD, our screens support either monochrome or 256 colors with high pixel resolution to give you sharp images and excellent visibility. In keeping with IDEC's attention to detail, our slimbody design adapts to applications where space is limited. With up to 8MB of memory and a 200MHz 32-bit RISC CPU, IDEC Touchscreens put control, power and speed at your fingertips. Versatile, High functionality Automation Software IDEC Touchscreens can function as either a stand alone controller or communicate with IDEC PLCs and a wide array of major manufacturers' PLCs. Touchscreens interface with any of your equipment to provide graphical data presentations in vivid color and to display bar graphs and meters to represent analog data. Illuminated pushbuttons can replace physical mechanical switches; pilot lamps can display on/off states and show almost any production information you need to monitor. 12.1" HG4F Programming power made easy Power Supplies IDEC's powerful WindO/I-NV2 software lets you create colorful graphical interfaces for easier production supervision and control. A built-in library of over 5000 bitmap images helps you easily display almost every manufacturing activity you want to control. Our programming software is intuitive and userfriendly. With re-sizeable pop-up screens, Windows compatible fonts, and multilingual text capabilities, you enjoy the utmost flexibility in designing and programming. 10.4" HG3F Sensors 5.7" HG2F USA: 800-262-IDEC Canada: 888-317-IDEC Communication & Networking 4.6" HG1F 71 Operator Interfaces OI Touchscreen Family PLCs Features The OI Touchscreen Family is ideally matched to today's sophisticated technology. Using a wide range of graphical options, you can represent specific equipment, make production information immediately apparent and instantly display safety problems. Consolidating controls on an IDEC touchscreen eliminates costly investments in wiring and installation of multiple pushbutton indicators on a traditional control panel. Just think how you can benefit with touchscreens. An expansion digital I/O module gives you the option of expanding your system with 16 DC inputs and 16 transistor outputs for basic PLC control (excluding 4.6" HG1F touchscreen). Basic Data Representation A built-in software library of over 5000 bitmapped images lets you graphically represent almost any plant activity or equipment that you want to monitor or control. In addition to representing meters, bar graphs and switches, you can also incorporate keypads to facilitate changing values. Our user-friendly programming software lets you design each screen by simply selecting objects from a pull-down menu or from a row of object icons and dropping it onto the screen work area. All bitmap images are available in 256 colors and are easily re-configurable. Ethernet Support Remote Network Local Area Network Ethernet The built-in 10BaseT Ethernet port found on the 10.4" and 12.1" touchscreens allow communications with PLCs using Ethernet/IP, Modbus TCP/IP or IDEC networking protocol. The touchscreens also allow you to remotely monitor machine-operating status via the Internet or your Local Area Network using any web browser. Regardless of your location, you can use your PC's browser (Netscape or Internet Explorer) to collect data about any touchscreen project. You can efficiently monitor and manage production activity from your office without the time or expense of travel. Recipe, Alarm and Trend Logging Compact Flash Card The Recipe function allows you to conveniently set operational parameters, which can be individually defined for different processes. The Alarm function stores historical events with a date and time stamp compliant to the ISA (Instrument Society of America) Standards, adding additional options to display and manage alarm messages. Trend Logging expresses data in graphical form according to the time period you define. Using these functions, you can quickly view production information and collect and manage data. OI Touchscreens (excluding 4.6" HG1F) support Compact Flash (CF) Cards with up to 512 MB of memory. In addition to storing recipe, alarm and trending data, the CF Card can also store screen captures in a BMP format for documentation purposes. The CF Card can hold one or more projects and you can easily transfer a project directly to another touchscreen by simply inserting the card into the second touchscreen and downloading what you need. Communication & Networking Sensors Power Supplies Automation Software Operator Interfaces Expansion I/O 72 www.idec.com Operator Interfaces OI Touchscreen Family Features, con't To meet your application needs, IDEC offers 12.1" and 10.4" TFT LCD screens, and 4.6" and 5.7" STN LCD screens that come with 256 colors or in monochrome to provide you with either multicolored or gray scale graphics. All screens have high pixel resolution and super bright LCD screens with 400 cd/m2 for the 12.1", 450 cd/m2 for the 10.4" screen, 250 cd/m2 for the 5.7" and 500 cd/m2 for the 4.6" screen to provide sharp quality images, with RS-232 / RS-485 / RS-422 communication. In addition, all IDEC Touchscreens communicate with IDEC as well as many other industry leading PLC manufacturers. Support of Leading Manufacturer's PLCs Their slim body style of: 35.3mm depth for the 4.6" HG1F, 50mm depth for the 5.7" HG2F, 49.6mm depth for the 10.4" HG3F, and 52.1mm depth for the 12.1" HG4F, provide an advantage in space in a panel. The OI Touchscreen Family is UL listed for use in hazardous locations (Class I Div. 2). In addition the 4.6" and 5.7" screens are IP65 and Nema Type 13 rated, while the 10.4" and 12.1" screens are IP66, Nema Type 4, 4X, 13 rated so they can be used in the most demanding industrial applications. PLCs The 10.4" and 12.1" IDEC Touchscreens can remotely communicate with multiple devices or PLCs over an Ethernet network, using Ethernet/IP, Modbus TCP/IP, or IDEC 1:N drivers. Only one centrally located IDEC touchscreen is necessary to communicate with up to 16 PLCs that are located in different locations. The Ethernet/IP driver supports the following Allen Bradley Series PLCs: Micrologix, SLC500, PLC5 and ControlLogix. Operator Interfaces Approvals and International Ratings Automation Software OI Link Communication IDEC Touchscreen communications capabilities expand well beyond IDEC brand PLCs. Other major PLC manufacturers supported are: Allen Bradley, Mitsubishi, Omron, Automation Direct (Koyo), Keyence, GE, Modicon, Siemens, Sharp, Hitachi, Schneider, Yaskawa, Fanuc, Matsushita Electric Works (Panasonic) and Yokogawa. Printer Function Use this capability to print alarm data so a hard-copy record of specific events can be maintained. Copies of screens can also be printed when needed for documentation. Serial printers are supported on all OI Touchscreens, while Parallel Printers are supported on 10.4" and 12.1" models. Power Supplies This permits a single PLC to communicate with multiple IDEC touchscreens, where one touchscreen serves as the master and up to 15 as slaves. An OI Link will accommodate communications over a maximum distance of 200 meters. The OI Link should be used whenever you are using more than one touchscreen in a location to monitor and control a single PLC. Barcode Reader Support Pass Thru Function Debugging Functions Two modes are available for either monitoring data or troubleshooting. Once you download the project you created in WindO/I-NV2 to the touchscreen, you can use the Debugging Mode to communicate directly with the touchscreen and switch between screens or view and modify batch data from the controls of your PC. In Simulation Mode, you can use simple On/Off control without connecting to the PLC. Communication & Networking This mode allows a single IDEC touchscreen to communicate with multiple PLCs. It is used when you need only one centrally located touchscreen to monitor and control PLCs in different locations. Depending on the PLC type, a maximum of 31 PLCs can be connected to one touchscreen. PLC manufacturers supported for 1:N communication are: IDEC OpenNet Controller and MicroSmart family, Automation Direct (Koyo): DirectLogic-DL205/405 and Modicon: Modbus RTU. Sensors IDEC Touchscreens provide a serial port that you can configure for use by special communication devices such as barcode readers. A barcode reader can send data directly to the touchscreen, where it can be used for quick viewing before being transferred to the PLC for further data manipulation. 1:N PLC Communication This function lets you download a PLC program from a PC through the touchscreen without interrupting operations. Only one cable is needed to program both units. The Pass Thru communications function is applicable to the following PLCs: IDEC OpenNet Controller and MicroSmart family, and Mitsubishi MELSECFX, FX3UC and Q. USA: 800-262-IDEC Canada: 888-317-IDEC 73 Operator Interfaces OI Touchscreen Family WindO/I-NV2 Operator Interfaces PLCs Programming Software Easy Programming: Intuitive Drag & Drop Functionality The WindO/I-NV2 software for all OI Touchscreens is the programming tool that lets you create colorful graphical interfaces to visualize operating conditions. The software is very intuitive with drag and drop functionality. The Help menus are a great source of information and a built-in library of bitmaps provides over 5000 images to help expand your creativity. The software also includes a debug function where you can go online with the touchscreen for monitoring and changing data. Flexible Screen Display for Efficient Editing With WindO/I-NV2 software, screens can be easily arranged. A total of 3000 base screens can be created (as allowed by the memory size). Sub-screens known as pop-up menus can be resized, made (showing backgrounds) using the superimpose function, and can be made to appear anywhere inside the base screen. Automation Software Easy to manage Projects and Screens Screens and Project Settings List: * Screens can be duplicated and their properties can be changed easily. * Project settings can be edited. * Devices, text, and images can be imported or exported. Screen Preview List: * Screens can easily be selected using the preview image function. Power Supplies Object List: * Each object displays its properties such as; type of device used, conditions and operations. Buttons: * A button selected from an object list is shown on the editing screen. Communication & Networking Sensors Extensive Image Library A built-in symbol library provides over 5000 symbols to help you create cutting-edge graphical screens. Image data from BMP, JPG, DXF, WMF, and ICO files can also be imported. 74 www.idec.com Operator Interfaces OI Touchscreen Family WindO/I-NV2 Software, con't Compatible with Standard WindowsTM Fonts Multilingual Capabilities for Worldwide Applications PLCs Operator Interfaces Fonts used in WindowsTM can be used on the OI Touchscreens, making it possible to choose from a variety of text styles. * The OI Touchscreen family can support other languages. With the text group function you can create a text database in different languages. Once the touchscreen is in a different country (e.g. China or Mexico) the customer can easily switch all text messages from English to Chinese or Spanish by a touch of a button. Automation Software * Windows 2000, Vista and XP make it possible to input Japanese, Simplified Chinese, Traditional Chinese, and Korean languages, Western European languages (English, German, French, Italian, Spanish, Dutch, Norwegian, Danish, Finnish, Swedish, etc.) Central European languages (Czech, Hungarian, Romanian, Croatian, Slovene, Polish, and Slavic), Baltic languages, Cyrillic languages (Russian, Ukranian, Bulgarian, Macedonian). Easy Programming of Operating Conditions Script function Power Supplies * Operating conditions for objects such as switches, lamps, bit/word write, screen switching, and many more are easy to use. Step by step wizards guide the user through the set-up process. Create Recipes to set parameters for different processes * Upload or download parameters to and from the PLC * 1,024 available channels; store up to 8,000 parameters per channel Set up Alarm Log function for messages and alerts * Meets ISA standards for visual alarm management * Select size and contrast of alarm message and status * Scroll a list of alarm messages Sensors * Monitors alarm conditions from a PLC and stores historical events with a date and time stamp * Users with programming knowledge in C can combine conditional statements, mathematical operations and other functions to create simple and complex processes. * Greatly reduce the programming required in the PLC. * A syntax check function is also available to provide easy program troubleshooting. Security function Communication & Networking Create Trend Graphs to monitor critical data points * Provides different levels of security and restrictions for multiple users on editing projects or displaying screens and objects. * Quickly view production information * Collect and manage data * Up to 16 channels in a graph USA: 800-262-IDEC Canada: 888-317-IDEC 75 Operator Interfaces OI Touchscreen Family Available Functions PLCs Category Communication Item Operator Interfaces Automation Software CC Switch Option HG4F DM link communication OI link communication Ethernet -- -- -- No host 1 MB 2 MB 2 MB 8 MB* 8 MB* RS232C/RS485 (422) Ethernet -- -- -- CF card slot -- -- -- -- 256 colors -- Monochrome -- -- Brightness Resolution Touch Switch CC Switch Expansion Unit (cd/m2) 500 250 250 450 400 (pixels) 300 x 100 320 x 240 320 x 160** 640 x 480 800 x 600 Available Functions Sensors -- 16 x 12 16 x 8 32 x 24 40 x 30 -- 4 x 1 row (bottom) -- -- Digital I/O unit -- System program download Font download Download via Ethernet -- -- -- Download via OI link Project transfer via CF card -- Printer output Backlight replacement Environment resistance Simulation Pass through Device monitor Web server function -- -- -- Overlapped screens Sub-screen superimpose Text group switching Script Part operating condition setting Logging Recipe Password setting Bit button Word button Goto screen button Print button Key button Keypad Selector switch Potentiometer Numerical input Character input Pilot lamp Picture display Message display Message switching display Alarm list display Alarm log display Numerical display Bar graph Trend chart Pie chart Meter Calendar Bit write command Word write command Goto screen command Timer Print command WindO/I-NV2 Functions -- Alarm log Parts Screen print command Debugging Log data upload tool Graphic library tool Screen import Text browser Device browser Script browser Picture browser Basic/advanced mode Preview Windows font Library function Global replace Work space *2MB used for OS **four tactile push regions (40 x 70 pixels) 76 HG3F Parallel Functions Power Supplies Standard Display Color Features Communication & Networking HG2F PLC link communication User Memory Interface HG1F www.idec.com Operator Interfaces OI Touchscreen Family Part Numbers OI Touchscreen Part Numbers 12.1" 10.4" 5.7" with CC Click 4.6" Description Color TFT LCD Touchscreen HG4F-JT22TFB Black* Color TFT LCD Touchscreen HG4F-JT22TFW-DH485-500 Light Gray Color TFT LCD Touchscreen with DF1 / DH485 converter/cable package for SLC 500 (w/RJ45 connector) HG3F-FT22TFW Light Gray Color TFT LCD Touchscreen HG3F-FT22TFB Black* Color TFT LCD Touchscreen HG3F-FT22TFW-DH485-500 Light Gray Color TFT LCD Touchscreen with DF1/DH485 converter/cable package for SLC 500 (w/RJ45 connector) HG2F-SS22VCF Light Gray Color STN LCD Touchscreen Light Gray Monochrome STN LCD Touchscreen HG2F-SS22VCF-DH485-500 Light Gray Color STN LCD Display with DF1 / DH485 converter/ cable package for SLC500 (w/RJ45 connector) HG2F-SB22VCF-DH485-500 Light Gray Monochrome STN LCD Display with DF1 / DH485 converter / cable package for SLC500 (w/RJ45 connector) HG2F-SS52VCF Light Gray Color STN LCD Touchscreen w/ CC Click Tactile Touchbutton Technology HG2F-SB52VCF Light Gray Monochrome STN LCD Touchscreen w/ CC Click Tactile Touchbutton Technology HG1F-SB22BF-W Light Gray Monochrome STN LCD Touchscreen, RS-232 comm. HG1F-SB22BF-B Black Monochrome STN LCD Touchscreen, RS-232 comm. HG1F-SB22YF-W Light Gray Monochrome STN LCD Touchscreen, RS-485/RS-422 comm. HG1F-SB22YF-B Black Monochrome STN LCD Touchscreen, RS-485/RS-422 comm. Automation Software HG2F-SB22VCF Operator Interfaces 5.7"* Bezel Color Light Gray PLCs HG4F-JT22TFW *Black bezel models available upon request. Accessories Accessories Accessory Converters Protective Sheet Replacement Backlight 32 Point Digital I/O HG9Y-ZSS2W Cable connecting PC to Touchscreen via RS-232 Serial Port HG9Z-XCM1A USB to RS-232 Convertor for PCs without Serial Ports FC4A-USB AB SLC500 (w/RJ45 connector) DF1 / DH485 Communication Package for HG2F/3F/4F HG9Z-GWDF1DH485-3 AB SLC500 (w/RJ45 connector) DF1 / DH485 Communication Package for 4.6" HG1F HG9Z-GWDF1DH485-4 For 12.1" HG4F (minimum order quantity is 2 pcs.) HG9Z-4DAP For 10.4" HG3F (minimum order quantity is 2 pcs.) HG9Z-3DAP For 5.7"HG2F (minimum order quantity is 5 pcs.) HG9Z-2D2 For 4.6" HG1F (minimum order quantity is 5 pcs.) HG9Z-1D For 10.4" HG3F & 12.1" HG4F (minimum order quantity is 10 pcs.) HG9Z-4K1 For 5.7" HG2F (minimum order quantity is 4 pcs.) HG9Z-2K1 For 4.6" HG1F (minimum order quantity is 10 pcs.) SLD-K02 For 12.1" HG4F HG9Z-4FB For 10.4" HG3F HG9Z-3FB2 For 5.7" HG2F HG9Z-2B1 For 4.6" HG1F HG9Z-1FB For all OI touchscreens HG9Z-2G1 For 10.4" HG3F & 12.1" HG4F (16 Inputs & 16 Outputs) HG9Z-3P102 For 5.7" HG2F (16 Inputs & 16 Outputs) HG9Z-2P101 Compact Flash Card 128MB CF Card for 5.7" HG2F, 10.4" HG3F, 12.1" HG4F HG9Z-MF128 Replacement Battery Lithium Battery for 4.6" HG1F HG9Z-XR1 USA: 800-262-IDEC Canada: 888-317-IDEC Communication & Networking OI Link Unit WindO/I-NV2 Programming software for all IDEC Touchscreen Series Sensors Mounting Clips Part Number Power Supplies Programming Tools Description 77 Operator Interfaces OI Touchscreen Family Cables PLCs Manufacturer Series FA-3S Applicable CPU PF3S-CP12/CP13 PF3S-CP11/CP11T FA-2J PF2J Micro3 FC2A Operator Interfaces Micro3C FC2A-%C IDEC OpenNet FC3A Communication Type RS232 RS232 PF2-CLA Automation Software Power Supplies PLC-5E SLC-5/03, SLC5/04, SLC5/05 1785 1747-L53, 1747-L54, 1747-L55 Communication & Networking Sensors Allen Bradley SLC5/05 1747-L55 MicroLogix 1000, 1100, 1200, 1500 1761, 1762, 1763, 1764 MicroLogix 1100 1763 ControlLogix 1756 CompactLogix 1768, 1769 FlexLogix 1794-L33, 1794-L34 Built-in Port HG9Z-1C121A HG9Z-3C115A Built-in Port HG9Z-XC183 HG9Z-3C125A RS485 Built-in Port HG9Z-1C131A HG9Z-2C145A RS232 Built-in Port HG9Z-XC183 HG9Z-3C125A RS485 Built-in Port HG9Z-1C131A HG9Z-2C145A Not Supported CAT 5 Ethernet Crossover cable RS485 RS422 FC4A-SX5ES1E Built-in Port FC4A-KC1CA FC4A-PC1/HPC1 HG9Z-XC183 or FC4A-KC1CA FC4A-KC2CA FC4A-PC2/HPC2 HG9Z-1C121A HG9Z-3C115A FC4A-PC3/HPC3 HG9Z-1C131A HG9Z-2C145A Not Supported CAT 5 Ethernet Crossover cable Contact IDEC* Contact IDEC* FC4A-SX5ES1E Built-in Port 1770-KF2 Built-in Port 1770-KF2 Ethernet 1785-ENET Not Supported CAT 5 Ethernet Crossover cable Ethernet Built-in Port Not Supported CAT 5 Ethernet Crossover cable RS232 Built-in Port HG9Z-XC100 HG9Z-2C125A DH485 Built-in Port please purchase IDEC converter: HG9ZGWDF1DH485-4 (DF1-DH485 converter) please purchase IDEC converter: HG9Z-GWDF1DH485-3 (DF1-DH485 converter) Ethernet 1761-NET-ENI Not Supported CAT 5 Ethernet Crossover cable Ethernet Buit-in Port Not Supported CAT 5 Ethernet Crossover cable RS232 Built-in Port HG9Z-XC500 HG9Z-2C135A Ethernet 1761-NET-ENI Not Supported CAT 5 Ethernet Crossover cable Ethernet Built-in Port Not Supported CAT 5 Ethernet Crossover cable RS232 Built-in Port Contact IDEC* Contact IDEC* Ethernet 1756-ENBT Not Supported CAT 5 Ethernet Crossover cable RS232 Built-in Port Contact IDEC* Contact IDEC* Ethernet Buit-in Port Not Supported CAT 5 Ethernet Crossover cable RS232 Built-in Port Contact IDEC* Contact IDEC* 1. * Consult IDEC for wiring schematic and cable. 2. Visit www.idec.com/oi for the most up-to-date list of cables. 78 Contact IDEC* RS485 RS232 1785 Contact IDEC* RS232 Ethernet PLC-5 HG2F/3F/4F Comm. Cable P/N PF3S-SIF2 PF3S-SIF4 RS232 FC4A, FC5A HG1F Comm. Cable P/N PF2-CLA RS485 Ethernet MicroSmart/Pentra MicroSmart Communication Module Required www.idec.com Operator Interfaces OI Touchscreen Family Cables Manufacturer Series Applicable CPU Communication Type Communication Module Required HG1F Comm. Cable P/N HG2F/3F/4F Comm. Cable P/N DL05 Ethernet D0-ECOM/DO-ECOM100 Not Supported CAT 5 Ethernet Crossover cable Direct Logc 06 DL06 Ethernet D0-ECOM/D0-ECOM100 Not Supported CAT 5 Ethernet Crossover cable D2-240 RS232 Built-in Port HG9Z-XC400 Contact IDEC* D2-240, D2-250, D2-250-1, D2-260 Ethernet Not Supported CAT 5 Ethernet Crossover cable Contact IDEC* Contact IDEC* Not Supported CAT 5 Ethernet Crossover cable Contact IDEC* HG9Z-2C155A Contact IDEC* Contact IDEC* Direct Logic 205 Automation Direct (Koyo) PLCs Direct Logc 05 D2-ECOM D2-ECOM-F Built-in Port RS232 D4-430, D4-440 D4-DCM RS422 Direct Logic 405 Operator Interfaces D2-ECOM100 Built-in Port D4-ECOM D4-430, D4-440,D4-450 Ethernet D4-ECOM-F D4-ECOM100 CPU 212, 214, 215, 216, 221, 222, 224, 224XP, 226, 226XM S7-300 CPU 313, 314, 315, 315-2DP, 316, 318 RS485 Built-in Port RS232 CP-340-RS232C or CP-341-RS232C CP-340-RS 422/485 or CP-341-RS 422/485 Siemens RS485 S7-400 CP-440-RS 422/485 or CP-441-RS 422/485 CPU 412, 414, 416, 416F-2, 417 CP-440-RS232C or CP-441-RS232C RS232 TWDLCA10DRF Schneider (Telemecanique, SquareD) HG9Z-1C121A HG9Z-3C115A HG9Z-1C121A HG9Z-3C115A RS232 TWD NAC 232D HG9Z-XC183 HG9Z-3C125A RS485 TWDNAC485D HG9Z-1C121A HG9Z-3C115A RS485 TWDNAC485T HG9Z-1C131A HG9Z-2C145A RS485 Built-in Port HG9Z-1C121A HG9Z-3C115A RS232 TWDNOZ232D HG9Z-XC183 HG9Z-3C125A RS485 TWDNOZ485D HG9Z-1C121A HG9Z-3C115A RS485 TWDNOZ485T or TWDXCPODM+ TWDNAC485T HG9Z-1C131A HG9Z-2C145A RS485 TWDXCPODM + TWDNAC485D HG9Z-XC183 HG9Z-3C125A RS232 TWDXCPODM + TWDNAC232D HG9Z-1C121A HG9Z-3C115A Momentum 171CCC96020 RJ-45 Ethernet Port Built-in RJ-45 Port Not Supported CAT 5 Ethernet Crossover cable Others Any PLCs that support MODBUS/TCP protocol RJ-45 Ethernet Port Built-in RJ-45 Port Not Supported CAT 5 Ethernet Crossover cable FP0 RS232 Built-in-Port HG9Z-XC300 HG9Z-2C165A Contact IDEC* Contact IDEC* FP RS232 FP1 RS422 Communication & Networking Panasonic (Aromat) TWDLMDA*DTK/DUK/DRT (* 20 & 40 CPUs) Built-in Port Built-in Port Sensors Others Twido RS485 RS485 Power Supplies TWDLCA*DRF ( *16,24,40 CPUs) Automation Software S7-200 Built-in-Port AFP8550 Built-in-Port 1. * Consult IDEC for wiring schematic and cable. 2. Visit www.idec.com/oi for the most up-to-date list of cables. USA: 800-262-IDEC Canada: 888-317-IDEC 79 Operator Interfaces OI Touchscreen Family Cables Manufacturer Series Applicable CPU Communication Type Communication Module Required HG1F Comm. Cable P/N PLCs Built-in-Port FP Sigma Panasonic (Aromat) con't RS232 RS232 Operator Interfaces FP2, FP2SH Automation Software Built-in-Port RS232 RS485 AJ71C24-S3/S6/S8 or AJ71UC24 RS485 A1SJ71C24-R2/R4 or A1SJ71UC24-R2/R4 RS232 HG9Z-XC145 HG9Z-3C135A Contact IDEC* Contact IDEC* A1SJ71C24-R2/R4 or A1SJ71UC24-R2/R4 HG9Z-XC203 HG9Z-3C145A RS232 Built-in-Port HG9Z-XC203 RS232 A0J2-C214-S1 HG9Z-XC145 HG9Z-3C135A Contact IDEC* Contact IDEC* RS485 A0J2-C214-S1 RS485 AJ71C24-S6/S8 or AJ71UC24 RS232 AJ71C24-S6/S8 or AJ71UC24 HG9Z-XC145 HG9Z-3C135A RS232 A1SJ71C24-R2/R4 or A1SJ71UC24-R2/R4 HG9Z-XC203 HG9Z-3C145A RS485 A1SJ71C24-R2/R4 or A1SJ71UC24-R2/R4 Contact IDEC* Contact IDEC* RS422 Built-in-Port HG9Z-XC255 HG9Z-3C165A RS232 Built-in-Port HG9Z-XC265 Contact IDEC* RS232 QJ71C24, QJ71C24N QJ71C24N-R2 HG9Z-XC203 HG9Z-3C145A RS485 QJ71C24 , QJ71C24N QJ71C24N-R2 Contact IDEC* Contact IDEC* Ethernet QJ71E71-100 QJ71E71-B5 QJ71E71-B2" Not Supported CAT 5 Ethernet Crossover cable RS232 AJ71QC24N-R2 HG9Z-XC145 HG9Z-3C135A RS485 AJ71QC24N, AJ71QC24N-R4 Contact IDEC* Contact IDEC* Ethernet AJ71QE71N3-T Not Supported CAT 5 Ethernet Crossover cable Ethernet AJ71QE71N-B2 Not Supported CAT 5 Ethernet Crossover cable Ethernet AJ71QE71N-B5 Not Supported CAT 5 Ethernet Crossover cable A2A, A3A, A2U, A3U, A4U A2US, A2USH-S1 Power Supplies Contact IDEC* AFP3462 A1SH MELSEC-A Contact IDEC* AFP3462 AJ71C24-S3/S6/S8 or AJ71UC24 A1N, A2N, A3N A0J2, A0J2H FPG-COM3 (AFPG803) Built-in-Port FP10, FP10SH A2CCPUC24 HG9Z-2C165A FPG-COM1 (AFPG801) FPG-COM2 (AFPG802) RS485 FP HG2F/3F/4F Comm. Cable P/N A2N A1SJH, A1SH, A2SH, A2C, A0J2H Mitsubishi A2A, A3A, A2US, A2USH A2U, A2USH-S1 Q00CPU, Q01CPU Q02CPU Q02CPU-A Sensors MELSEC-Q Q02CPU, Q02HCPU, Q06HCPU, Q12PHCPU, Q25HCPU Communication & Networking Q00JCPU,Q00CPU,Q01CPU,Q02 CPU,Q02HCPU,Q06HCPU,Q12H CPU,Q25HCPU MELSEC-QnA Q4ACPU, Q4ARCPU, Q3ACPU, Q2ACPU-S1, Q2ACPU 1. * Consult IDEC for wiring schematic and cable. 2. Visit www.idec.com/oi for the most up-to-date list of cables. 80 www.idec.com Operator Interfaces OI Touchscreen Family Cables Manufacturer Series Applicable CPU Mitsubishi, continued MELSEC-FX HG1F Comm. Cable P/N HG2F/3F/4F Comm. Cable P/N RS232 A1SJ71QC24N-R2 HG9Z-XC203 RS485 A1SJ71QC24N Contact IDEC* HG9Z-3C145 Contact IDEC* Ethernet A1SJ71QE71N3-T Not Supported CAT 5 Ethernet Crossover cable Ethernet A1SJ71QE71N-B2 Not Supported CAT 5 Ethernet Crossover cable Ethernet A1SJ71QE71N-B5 Not Supported CAT 5 Ethernet Crossover cable Built-in Port HG9Z-XC255 HG9Z-3C165A RS422 Built-in Port w/ cable FX20P-CADP HG9Z-XC255 HG9Z-3C165A FX0,FX0N,FX2N,FX2NC,FX3U C,FX3U RS422 Built-in Port HG9Z-XC245 Contact IDEC* RS232 FX2N-232-BD Contact IDEC* Contact IDEC* RS422 FX2N-422-BD and FX-20PCADP HG9Z-XC255 HG9Z-3C165A FX2N-422-BD HG9Z-XC245 Contact IDEC* RS232 FX1N-232-BD Contact IDEC* Contact IDEC* RS422 FX1N-422-BD and FX-20PCADP HG9Z-XC255 HG9Z-3C165A FX1N-422-BD HG9Z-XC245 Contact IDEC* FX2N FX1N RS422 FX3UC, FX3U RS232 CPM1, CPM1A HG9Z-XC255 HG9Z-3C165A Contact IDEC* Contact IDEC* FX3U-232-BD Contact IDEC* Contact IDEC* RS232 CPM1-CIF01 HG9Z-XC213 HG9Z-3C155A RS422 CPM1-CIF11 Contact IDEC* Contact IDEC* HG9Z-XC213 HG9Z-3C155A HG9Z-XC155 HG9Z-3C135A Contact IDEC* Contact IDEC* RS232 Built-in-Port CPM1-CIF01 Power Supplies CPM2A Built-in Port FX3U-232ADP Automation Software RS422 FX0,FX0N,FX2N,FX2NC,FX3U C,FX3U Operator Interfaces FX1,FX2,FX2C Communication Module Required PLCs Q2ASH CPU-S1, Q2ASHCPU, Q2ASCPU-S1, Q2ASCPU Communication Type C120-LK201-V1 RS232 C500, C500F, C1000H, C2000, C2000H Omron SYSMAC-C C1000HF C200HE, C200HG, C200HX CQM1H, C200HSCPU21/23/31/33 C120-LK202-V1 RS422 C500-LK201-V1 RS422 C500-LK203 RS232 C500-LK203 HG9Z-XC155 RS232 C200H-LK201 HG9Z-XC155 RS422 C200H-LK202 RS422 C200HW-COM03/06 HG9Z-3C135A Contact IDEC* Contact IDEC* C200H-LK201 HG9Z-XC155 HG9Z-3C135A C200HW-COM02/040/5/06 HG9Z-XC213 HG9Z-3C155A RS232 C120-LK201-V1 HG9Z-XC155 HG9Z-3C135A RS422 C120-LK202-V1 Contact IDEC* Contact IDEC* RS232 Built-in-Port HG9Z-XC213 HG9Z-3C155A RS232 Communication & Networking C120, C120F C500-LK203 Sensors C200HS C500-LK201-V1 1. * Consult IDEC for wiring schematic and cable. 2. Visit www.idec.com/oi for the most up-to-date list of cables. USA: 800-262-IDEC Canada: 888-317-IDEC 81 Operator Interfaces OI Touchscreen Family Cables PLCs Manufacturer Series SYSMAC-C Operator Interfaces Omron con't Keyence CS1 Applicable CPU C200HE-CPU42, C200HGCPU43/63, C200HX-CPU44/64 CS1G, CS1H Contact IDEC* Contact IDEC* RS232 Built-in-Port HG9Z-XC213 HG9Z-3C155A RS232 Built-in-Port KV-700/1000 KV-700, KV-1000 RS232/485/422 KV-L-20R 10 I/Os, 14 I/Os RS232 Built-in-Port 23 I/Os, 28 I/Os RS485 Built-in-Port CPU 311, 313, 323, 331, 341, 350, 351, 352, 360, 363, 364, 374 RS485 Built-in-Port S10mini RS232 RS485 RS485 JW-21CM JW-50CU/CUH, JW-70CU/ CUH, JW-100CU/CUH RS485 JW-10CM JW-22CU, JW-70CU/CUH, JW-100CU/CUH RS232 Built-in Port Hitachi RS232 RS485 S10V Sensors TOYOPUC-PC2J Buit-in Port RS232 LQE160 RS485 LQE165 RS232 LQE560 RS485 LQE565 RS485 Buit-in Port RS232 LQE560 RS485 LQE565 PC2J RS485 Buit-in Port PC3J RS485 Buit-in Port PC3JD, PC3JG RS485 Buit-in Port TC200 TC3-13B1 RS232 Buit-in Port TCmini TC03-01, TC03-02 RS232 Buit-in Port YASKAWA ELECTRIC CORPORATION RS232 Buit-in Port Machine Controller MP920, MP930, MP2300 RS232 217IF FANUC Power Mate Power Mate-MODEL D RS422 Buit-in Port 16i, 160i RS232 Buit-in Port Toshiba Machine Works Communication & Networking TOYOPUC-PC3J LQP510 1. * Consult IDEC for wiring schematic and cable. 2. Visit www.idec.com/oi for the most up-to-date list of cables. 82 HG9Z-XC273A Built-in Port RS485 RS232 Contact IDEC* IC693CMM311 JW-21CU, JW-22CU, JW31CUH/H1, JW-32CUH/H1, JW-33CUH/H1/H2/H3 S10mini HG9Z-3C155A CS1W-SCB41 (port2) KV-10,16,24,40 JW-32CUH/H1, JW-33CUH/ H1/H2/H3 HG9Z-XC213 CS1W-SCB41 (port1) Visual KV New Satellite JW HG2F/3F/4F Comm. Cable P/N RS422 KV 10, 16, 24, 40, 80 CPU 331, 341, 350, 351, 352, 360, 363, 364, 374 JTEKT(TOYODA) Built-in-Port CJ1M, CJ1H, CJ1G Series 90-30 Automation Software RS232 HG1F Comm. Cable P/N Built-in-Port Conventional KV GE Fanuc Power Supplies RS232 Communication Module Required CJ1 VersaMax Nano/Micro SHARP Communication Type www.idec.com Contact IDEC* Contact IDEC* Operator Interfaces OI Touchscreen Family Cables Manufacturer FA-M3 Applicable CPU FA-M3(F3SP05, F3SP20, F3SP21, F3SP25, F3SP30, F3SP35, F3SP38, F3SP53, F3SP58, F3FP36, F3BP20, F3BP30) FA-M3(F3SP05, F3SP21, F3SP25, F3SP28, F3SP35, F3SP38, F3SP53, F3SP58) Communication Type RS232 F3LC11-1N RS485 F3LC11-2N RS232 Buit-in Port RS232 RS232 FLEX-PC RS485 F55 NJ-RS2 NJ-RS4 MICREX-F RS232 NV1L-RS2 RS232 NC1L-RS2 RS485 NC1L-RS4 F80H, F120H, F120S, F140S, F150S RS232 F30, F50, F50H, F55, F60, F70, F70S, F80H, F81, F120H, F120S, F140S, F150S, F250 RS232 T1: T1-16,T1-28,T1-40 RS232 Buit-in Port RS485 CU111 RS485 RS485 RS485 CU111 T2: PU224 RS485 Buit-in Port RS232 Buit-in Port RS485 CM231E RS232 CM232E Toshiba T2N: PU215N,PU235N, PU245N RS232 RS485 S2I/ S2E/L1/S2/S3: PU672T, PU662T, PU612E, L1PU11H,L1PU12H, S2PU82, S2PU72, S2PU32, S2PU22, S3PU65, S3PU55, S3PU45, S3PU21 RS485 Buit-in Port K10S1 RS232 Buit-in Port K200S K300S RS232 Buit-in Port RS232 G7L-CUEB RS232 G7L-CUEC RS232 G6L-CUEB RS232 G6L-CUEC RS232 G4L-CUEA Communication & Networking Buit-in Port Sensors RS485 K80S Contact IDEC* Buit-in Port T3/T3H: PU315, PU325, PU325H, PU326H K80S, K120S, K200S Contact IDEC* Buit-in Port RS485 T2E: PU234E MASTER-K FFK120A-C10 T1S: T1-40S PROSEC T Series LS Industrial Systems FFU120B Power Supplies RS232 V Series NS-RS1 Automation Software F70 NB-RS1-AC/DC RS485 RS485 FUJI HG2F/3F/4F Comm. Cable P/N Buit-in Port RS232 RS232 HG1F Comm. Cable P/N Operator Interfaces RS485 NB1, NB2, NB3, NJ-CPU-E4, NJ-CPU-A8, NJ-CPU-B16, NS Communication Module Required PLCs YOKOGAWA Series 1. * Consult IDEC for wiring schematic and cable. 2. Visit www.idec.com/oi for the most up-to-date list of cables. USA: 800-262-IDEC Canada: 888-317-IDEC 83 Operator Interfaces OI Touchscreen Family Specifications General Specifications Model HG1F HG2F HG3F PLCs Voltage 24V DC Voltage Range 20.4 to 28.8V DC 19.2 to 28.8V DC Power Consumption 10W maximum 25W maximum Inrush Current 20A maximum 15A maximum (cold start) Allowable Momentary Power Interruption Dielectric Strength 10 ms minimum 1,000V AC, 10 mA, 1 minute between power and FG terminals 1,500V AC, 10 mA, 1 minute between power and FG terminals 50 M minimum between power and FG terminals (500V DC megger) 10 M minimum between power and FG terminals (500V DC megger) Operator Interfaces Insulation Resistance CR2032 lithium batteryy Life approx. 4 years (25C) Backup Battery -- Operating Temperature 0 to 50C (no freezing) Operating Humidity 10 to 90% RH (no condensation) 20 to 85% RH (no condensation) -20 to +60C (no freezing) 10 to 90% RH (no condensation) 10 to 95% RH (no condensation) Pollution Degree 20 to 85% RH (no condensation) 2 (IEC 60664-1) Corrosion Immunity Automation Software 0 to 45C (no freezing) 10 to 95% RH (no condensation) Storage Temperature Storage Humidity Power Supplies HG4F Atmosphere free from corrosive gases 10 to 20Hz amplitude 0.625 mm, 20 to 55Hz acceleration 9.8 m/s2 (1G), 2 hours per axis on each of three mutually perpendicular axes Vibration Resistance (damage limits) Shock Resistance (damage limits) 147 m/s2 (15G), 11 ms, 5 shocks on each of three mutually perpendicular axes Noise Immunity Fast transient/burst test, common mode: Level 3, power terminals: 2 kV, communication line: 1 kV (IEC/EN 61000-4-4) Electrostatic Discharge ESD-3 (RH-1), Level 3, (contact 6 kV, aerial 8 kV) (IEC/EN 61000-4-2) Mounting Panel mounting Degree of Protection IP65 NEMA TYPE 13 IP66 NEMA TYPE 4, 4X, 13 Dimensions (mm) 147W x 47H x 39.3D 172W x 136H x 56D 324W x 240H x 56D 348W x 270H x 58D Weight (approx.) 280g 800g 2800g 3400g Operation Specifications Model HG2F HG1F Standard CC Switch Option Switching Element Touch Region Resolution 1x1 Operating Force 16 x 8 32 x 24 -- 4 x 1 row (bottom only) -- -- 2.5 to 5.0N 0.2 to 0.8N 0.2 to 0.8N 0.2 to 0.8N 1,000,000 operations Acknowledge Sound Electronic buzzer Sensors Screen Types Communication & Networking 40 x 30 16 x 12 Mechanical Life Base screen, popup screen, system screen Base screen: 3000 max., popup screen: 3015 max. Base screen: 3000 max., popup screen: 3000 max. User Memory 1MB (including expansion fonts) Parts Bit Button, Word Button, Goto Screen Button, Print Button, Key Button, Keypad, Selector Switch, Potentiometer, Numerical Input, Character Input, Pilot Lamp, Multi-state Lamp, Picture Display, Message Display, Message Switching Display, Alarm List Display, Alarm Log Display, Numerical Display, Bar Graph, Trend Chart, Pie Chart, Meter, Calendar, Bit Write Command, Word Write Command, Goto Screen Command, Timer, Print Command, Screen Script Command Calendar 8MB* ESC/P, PC-PR: Epson VP-700 SII: DPU414 Power Failure Backup ESC/P, PC-PR, PCL, EPSON LP2500/VP-700/PX-V600/ Stylus C83, C84, C87, C88, D88, HP Deskjet 3820 Backup data: Calendar, log data, keep internal relay, keep internal register Backup Duration Battery Life 2MB Year, Month, Day, Hour, Min., Sec., Day of Week Print Function (support) 1 month (at 25C) after full charging for two days 4 years (at 25C) -- *2MB for OS 84 HG4F Resistive membrane CC Switch Quantity Number of Screens HG3F www.idec.com Operator Interfaces OI Touchscreen Family Display Specifications Model HG2F HG1F Monochrome STN Monochrome Color STN Monochrome STN HG3F HG4F Color Color Color TFT Effective Display Area (mm) 115W x 39W 118.2W x 89.4H 211.2W x 158.4H 246W x 184.5H Display Resolution 300W x 100H 320W x 240H pixels 640W x 480H pixels 800W x 600H pixels 100,000 hours minimum 60,000 hours minimum LCD Life 50,000 hours minimum Contrast Adjustment Possible in steps using the front touch screen Backlight Cold-cathode tube 40,000 hours nominal (Note) Backlight Control Possible 1/4 size 8 x 8 pixels (Western European language: ISO 8859-1, Central European language: ANSI 1250, Japanese katakana and symbols: JIS 8-bit code) 1/2 size 8 x 16 pixels (Western European language ISO 8859-1, Central European language: ANSI 1250, Japanese katakana and symbols: JIS 8-bit code) 16 x 32 pixels, 24 x 48 pixels, 32 x 64 pixels (Western European language: ISO 8859-1) Full size 16 x 16 pixels (Japanese JIS first and second level characters, simplified Chinese, traditional Chinese, Korean) Double size 32 x 32 pixels (Japanese JIS first level characters, Mincho font) 40 characters x 30 lines (40 x 20, cc click type) 1/4 size 37 characters x 12 lines 1/2 size 37 characters x 6 lines 40 characters x 15 lines (40 x 10, cc click type) 80 characters x 30 lines 100 characters x 37 lines Full size 18 characters x 6 lines 20 characters x 15 lines (20 x 10, cc click type) 40 characters x 30 lines 50 characters x 37 lines Double size 9 characters x 3 lines 10 characters x 7 lines (10 x 5, cc click type) 20 characters x 15 lines 25 characters x 18 lines Character Magnification Graphics Type 100 characters x 75 lines 0.5, 1, 2, 3, 4, and 8 vertically and horizontally Blink (1 or 0.5 sec period), reverse, bold, shadowed Power Supplies Character Attribute 80 characters x 60 lines Automation Software Quantity of Characters 50,000 hours nominal (Note) Automatic OFF Backlight Replacement Display Character Size Cold-cathode tube (2 tubes) Operator Interfaces 50,000 hours nominal (Note) Backlight Life PLCs LCD Color Straight line, polyline, polygon, rectangle, circle, ellipse, arc, pie, equilateral polygons (3, 4, 5, 6, 8), paint, bitmap image Window Display 3 popup screens + 1 system screen Note: The backlight life refers to the time until the surface brightness reduces to a half after using continuously at room temperatures. Sensors Communication & Networking USA: 800-262-IDEC Canada: 888-317-IDEC 85 Operator Interfaces OI Touchscreen Family Interface Specifications CF Card Interface Specifications Interface Specifications Parallel Interface Specifications (HG3F/4F) Ethernet Specifications (HG3F/4F) Compact Flash Type I standard compliant* -- IEEE 802.3 standard compliant, 10Base-T -- Centronics interface compliant -- 50-pin compact flash card connector D-sub 25-pin female connector -- PLCs Electrical Characteristics Connector *Memory size supports up to 512MB. Interface Specifications Maintenance Communication RS232C EIA RS232C compliant Electrical Characteristics EIA RS232C compliant Transmission Speed 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps Transmission Speed 9600, 19200, 38400, 57600, 115200 bps Synchronization Asynchronous Synchronization Asynchronous Communication Method Half duplex, proprietary protocol Communication Method Half or full duplex Connector Mini DIN 8-pin connector Control System Hardware control or none Connector D-sub 25-pin female connector Operator Interfaces Electrical Characteristics Automation Software RS485 (422) OI Link Communication Electrical Characteristics EIA RS485 compliant Transmission Speed 38400, 57600, 115200 bps Electrical Characteristics EIA RS485 (422) compliant Synchronization Asynchronous Transmission Speed 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps Communication Method Half duplex, proprietary protocol Synchronization Asynchronous Connector Special connector Communication Method Half or full duplex Control System Hardware control or none Connector D-sub 25-pin female connector 1 Mounting Style Mounted on the rear of the HG unit Sensors Output Input Power Supplies Expansion Unit (Digital I/O Unit) Applicable Quantity Input Points 16 Voltage 12 to 24V DC (allowable range 10 to 28V DC) Isolation Method Photocoupler Output Points 16 Load Voltage 12 to 24V DC (allowable range 10 to 28V DC) Isolation Method Photocoupler Output Signal NPN open collector Output ON Voltage 1.6V maximum Output Current 30 mA max. per point, 200 mA total 24-pin connector (Fujitsu FCN-365P024-AG) 2 connectors for inputs and outputs Communication & Networking Connector 86 www.idec.com Operator Interfaces OI Touchscreen Family Dimensions & Panel Cutouts HG1F Dimensions HG1F Installation Panel Layout 65.8mm PLCs 76mm Mounting Clip 66+10 137+1.5 0 4mm 147mm Operator Interfaces 39.3mm Panel thickness: 1.6 to 5mm Mounting Clip 136.8mm HG2F Dimensions HG2F Installation Panel Layout Mounting Clip 126mm 136mm Panel 6mm HG2F Panel thickness: 1.6 to 5mm 56mm 172mm Automation Software 126.5+0.5 0 162.5+0.5 0 Mounting Clip 162mm HG3F Dimensions HG3F Installation Panel Layout Power Supplies Mounting Clip Panel 301mm 228+0.5 0 240mm 6mm HG3F Panel thickness: 2 to 5mm 55.8mm 324mm 302+0.5 0 Mounting Clip HG4F Dimensions Sensors 301mm HG4F Installation Panel Layout Mounting Clip Panel 258+10 Communication & Networking 270mm 331mm 332+10 6mm HG4F Panel thickness: 2 to 5mm 58mm 348mm Mounting Clip 331mm All dimensions in mm. USA: 800-262-IDEC Canada: 888-317-IDEC 87