2
G5V-2G5V-2
High Sensitivity Models
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
■Contact Ratings
Note Note:P level: l60 = 0.1 x 10–6/operation
■Characteristics
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC
Rated current 50 mA 30 mA 25 mA 16.7 mA 12.5 mA 8.33 mA 6.25 mA
Coil resistance 60
W
166.7
W
240
W
540
W
960
W
2,880
W
7,680
W
Coil inductance
(H) (ref. value) Armature ON 0.18 0.46 0.70 1.67 2.90 6.72 20.1
Armature OFF 0.57 0.71 0.97 2.33 3.99 9.27 26.7
Must operate voltage 75% max. of rated voltage
Must release voltage 5% min. of rated voltage
Max. voltage 180% of rated voltage at 23°C 150% of rated
voltage at
23°C
Power consumption Approx. 150 mW Approx.
200 mW Approx.
300 mW
Item Standard models High sensitivity models
Load Resistive load (cos
f
= 1)
Rated load 0.5 A at 125 VAC; 2 A at 30 VDC 0.5 A at 125 VAC; 1 A at 24 VDC
Contact material Ag + Au-clad
Rated carry current 2 A
Max. switching voltage 125 VAC, 125 VDC
Max. switching current 2 A 1 A
Max. switching power 62.5 VA, 60 W 62.5 VA, 24 W
Failure rate (reference value) 0.01 mA at 10 mVDC
Item Standard models High sensitivity models
Contact resistance 50 m
W
max. 100 m
W
max.
Operate time 7 ms max.
Release time 3 ms max.
Bounce time Operate: approx. 0.3 ms
Release: approx. 1.5 ms
Max. operating frequency Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 M
W
min. (at 500 VDC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between con-
tacts of different polarity
750 VAC, 50/60 Hz for 1 min between contacts
of same polarity
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between con-
tacts of different polarity
500 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Impulse withstand voltage 1,500 V (10 x 160 µs) between coil and contacts (conforms to FCC Part 68)
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 200 m/s2 (approx. 20G) Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)
Endurance Mec hanical: 15,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr)
Ambient temperature Operating:
-
25°C to 65°C (with no ic ing) Operating:
-
25°C to 70°C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 5 g