Agilent N6700 Modular Power System Family Low-Profile MPS Mainframes N6700B-N6702A, N6710B-N6712A DC Power Modules N6731B-N6784A Data Sheet Introducing... Seven new modules up to 500 W For details, see pages 7, 11, 12 For Power Solutions for R&D- See back cover * Ideal for ATE systems in R&D, design validation, and manufacturing * Small size: up to four outputs in 1U of rack space * Flexible, modular system: Lets you mix and match power levels and performance levels to optimize your investment * Performance modules for critical test requirements * Value modules for basic DC power requirements * Fast command processing time and output speed to improve throughput * Connect via GPIB, LAN, or USB * Fully compliant to LXI Class C specification Small Size and Flexibility for ATE Power supplies are a fundamental component of every test system in industries including aerospace and defense, consumer electronics, computers and peripherals, communications, semiconductor and automotive electronics. Today's complex automatic test equipment (ATE) systems often require multiple power sources. Test system designers are challenged to keep costs down by reducing rack space occupied by these multiple power supplies and to continually increase test system throughput. The Agilent N6700 Low-Profile Modular Power System (MPS) is a 1U (rack unit) high, multiple-output programmable DC power supply system that enables test system integrators to optimize performance, power and price to match test needs. The Agilent N6700 MPS gives test system designers the flexibility to mix and match from over 30 different DC power modules to create a 1- to 4-channel DC power system optimized to meet specific test requirements. Test system engineers can invest in high-performance outputs where speed and accuracy are needed, or purchase basic performance outputs for simple DC power requirements. N6700 System Features Figure 1. Connectivity: GPIB, 10/100 Base-T ethernet, and USB 2.0 all standard Small size The Agilent N6700 MPS uses an advanced switching power supply design that fits within 1U of rack space (1.75 in./44 mm). It has side air vents (no top or bottom air vents) so other instruments can be mounted directly above or below it. (Requires rack mount kit; see ordering information.) Built-in measurement of voltage and current The N6700 modules come standard with built-in measurement of voltage and current to simplify wiring and design of an ATE system. 2 Protection features Each N6700 module is protected against over-voltage, over-current, and over-temperature. A fault condition in one module can be detected within 10 microseconds by other modules so that they can be quickly shut down to avoid hazardous conditions on your device under test (DUT). Connectivity The N6700 MPS comes standard with GPIB, USB 2.0, and 10/100 Base-T ethernet LAN interfaces. While GPIB is best suited for use with existing systems, Agilent offers USB and LAN to allow you to take advantage of the availability, speed, and ease-of-use of common computer industry standard interfaces. The N6700 is fully compliant with the LXI Class C specification. Security When used in systems running GPIB, the LAN and/or USB interfaces can be disabled for extra security. Also, all non-volatile RAM data and settings can be cleared from the front panel. Control from any browser The N6700 can be controlled via a standard web browser. The N6700 contains a web server that provides web pages for monitor, control, and setup of the MPS. Output on V1 Module 1 V2 Delay 2 V3 Module 2 Module 3 Delay 3 Figure 2. Output sequencing Output sequencing Each DC power module can be individually set to turn on or to turn off with a delay. By adjusting the delay times and then commanding the N6700 to turn on, you can set the N6700 modules to sequence on in a particular order. The same sequencing capability is available to shut down the modules in a particular order. For applications that require more than four DC power modules to be sequenced, this output sequencing can be extended across multiple N6700 mainframes. When the I/O ports on the rear panel of the mainframes are wired together, a pair of synchronization signals can be sent between mainframes, allowing the output sequences of all mainframes to be synchronized. This capability is supported on N6700B, N6701A and N6702A mainframes. It is not supported on the discontinued N6700A mainframe. 3 Programmable voltage slew For some applications, like inrush limiting or powering rate-sensitive devices, it is necessary to slow down and control the speed of the power supply to maintain a specific voltage slew rate. The N6700 provides programmable voltage slew rate, so that you can easily control the speed at which the output slews from one voltage to another. You can set the speed of a voltage change anywhere from its maximum up/down programming speed to its slowest change of up to 10 seconds. Programmable voltage slew is available from the front panel when operating the N6700 manually or via computer control. Series operation To increase available voltage and power, similarly rated outputs can be operated directly in series. Easy parallel operation with virtual channels To increase available output power and current, identical outputs can be operated in parallel. To simplify parallel operation for applications requiring currents greater than any single output can provide, the N6700 offers virtual channels, a firmwarebased feature that allows the N6700 system to treat up to 4 channels as a single, synchronized channel. Once configured, all functions (sourcing, measurements, triggering, protection, and status monitoring) behave as if there is 1 channel of up to 4 times the capacity of a single channel, without writing a single line of code to manage the interaction and synchronization of the paralleled power supplies. Virtual channel capability is available from the front panel when operating the N6700 manually or via computer control. Power management feature allows you allocate mainframe power Often, a DUT requires a single high power DC source and several very low power DC sources. Since the DUT does not require full power to all outputs, you may choose to save money configuring a system where the sum of the power modules installed in a mainframe exceeds the total power available from the mainframe. In this case, the power management 4 features of the N6700 allow you to allocate mainframe power to the outputs where it is needed, achieving maximum asset utilization and flexibility. This feature provides safety from unexpected and dangerous shutdowns that can occur with power systems without power management when operated in a similar way. For example, if your DUT requires 280 W on its main input, and 10 W each on three auxiliary inputs, you can configure a system consisting of one 300 W DC module and three 100 W DC modules. Even though the sum of the module power is 600 W, you can still use the N6700B 400 W MPS mainframe. Thanks to the power management feature, you can allocate the full 300 W to the 300 W module while you allocate only 33 W to each of the 100 W modules. Note that if you install one of the new 500 W modules in an N6700B 400 W MPS mainframe, you may not be able to run this module at its full rated output power. Plug high power mainframes into standard AC sockets without dedicated high current AC circuits When you first turn on the N6702A 1200 W MPS mainframe, the mainframe automatically senses the power available from the AC line. If the AC line voltage is such that the resulting current would exceed a standard AC outlet rating, the mainframe automatically scales back the available output power to prevent overloading the AC line. The N6702A will limit the output power to 600 W allowing the high power mainframe to be plugged into any standard outlet. This is very convenient for initial bench checkout of the MPS system. It is also very convenient for test development, which is typically done on the bench when DUT is not yet driven to full power. You can also control this power reduction by manually allocating less than the full available mainframe power among the modules. As a result, the N6702A will draw less power (and less current) from the AC line. Triggering The N6700 Low-Profile MPS mainframe has hardware trigger in/trigger out signals which permit the N6700 to be synchronized with external events. For example, a switch closure in the fixture can trigger the N6700 to apply voltage to the DUT or take a measurement. Drivers The N6700 comes with both VXIplug&play drivers and IVI-COM drivers. LabView drivers are also available at NI.COM. Programming language The N6700 supports SCPI (Standard Commands for Programmable Instruments). Firmware updates The N6700 firmware is stored in FLASH ROM and can be easily updated when new features become available. Firmware can be downloaded into the N6700 over GPIB, LAN, or USB using the supplied firmware update utility program. Agilent recommends that you keep your N6700 system up to date with the latest firmware available at www.agilent.com/find/ N6700firmware. Output disconnect and polarity reversal relays Modules in the N6700 can be individually ordered with optional Output Disconnect Relays (option 761) or Output Disconnect/Polarity Reversal Relays (option 760). See the table on page 16 for option 760 and 761 availability. All relays are built into the module, so no additional wiring or rack space is needed to incorporate the relay function. Although the plus and minus rail of the output power mesh are physically disconnected from the output terminals with options 760 and 761, a small AC network is still connected across the plus and minus output terminals, This AC network is required for EMI compliance. 5 With option 761, Output Disconnect Relays, mechanical relays disconnect both the plus and minus side of the power supply, including the sense leads. With option 760, Output Disconnect/ Polarity Reversal Relays, mechanical relays switch the leads on both the plus and the minus side of the power supply, including the sense leads, resulting in a voltage polarity reversal at the DUT. In addition to polarity reversal, option 760 provides the same output disconnect function as option 761. Note: Output current is limited on some modules when option 760 Output Disconnect/Polarity Reversal Relays is installed. See the "Available options" table on page 16 for more information about maximum current limitations with option 760. Figure 3. Front panel with up to 4 channels displayed simultaneously (Picture shows 3 channels installed.) Figure 4. Rear panel (Picture shows 3 channels installed.) Front panel Quick disconnects In addition to full control over its three standard interfaces, the N6700 has a full featured front panel to permit easy manual operation for test prototyping, debugging, and troubleshooting when used in an ATE system. You can have confidence that the N6700 is working properly because you can view the settings and actual output values on all four outputs at the same time. Each power module has quick disconnects for easy system setup and maintenance. Quieter fans to keep noise down To reduce acoustic noise, the N6700 mainframes employ fan speed control. When operating at less than full output power, the cooling fans spin slower and generate less noise. Rack mount kit The N6700 is easily rack-mounted using the N6709A rack mount kit. This kit provides all the necessary hardware to rack mount one N6700 mainframe in only 1U of rack space. This rack mount kit includes front rack ears and rear supports which take the place of standard rack rails and/or slides. Note that standard rack rails or slides are not compatible with the N6700 because of its 1U size and airflow requirements. Universal AC input The N6700 has a universal input that operates from 100-240 Vac, 50/60/400 Hz. There are no switches to set or fuses to change when switching from one voltage standard to another. The AC input employs power factor correction. Figure 5. Quick disconnects for power and sense leads 6 Choosing the right DC Power Modules to meet your ATE needs N6750 high-performance series N6760 precision series For applications where the power supply plays a critical role - Now with available power up to 500 W For applications where precision is required - Now with available power up to 500 W The Agilent N6750 Series of highperformance, autoranging DC power modules provides low noise, high accuracy and programming speeds that are up to 10 to 50 times faster than other programmable power supplies. In addition, Agilent has, for the first time, included high-speed test extensions in general-purpose power supplies. The high-speed test extensions offer an oscilloscope-like digitizer that simplifies system configuration and increases measurement accuracy when viewing high-speed transient or pulse events within the DUT. In addition, autoranging output capabilities enable one power supply to do the job of several traditional power supplies. The Agilent N6760 Series of precision DC power modules provides precise control and measurements in the milliampere and microampere region with the ability to simultaneously digitize voltage and current, and capture those measurements in an oscilloscope-like data buffer. Figure 6b. The N6753A - N6756A High performance and the N6763A - N6766A Precision DC power modules each occupy two module slots within the mainframe. All other modules occupy 1 module slot. N6730/40/70 basic series For basic DC applications - Now with voltages up to 150 V The Agilent N6730, N6740 and N6770 Series of DC power modules provide programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources, such as fixture control. N6783 application-specific series For details on these products and how they can be used for specific applications visit www.agilent.com/find/N6783A-BAT www.agilent.com/find/N6783A-MFG and download the N6783A-BAT Data Sheet, 5990-8662EN and the N6783AMFG Data Sheet, 5990-8643EN. N6780 SMU series For applications where multi-quadrant operation and high-precision are required Figure 6a. The basic series For details on these products and how they can be used for applications including battery drain analysis and function test, visit www.agilent.com/find/N6780 and download the N6780 Series Source/ Measure Units (SMUs) for the N6700 Modular Power System Data Sheet, literature number 5990-5829EN Figure 6c. User re-configurable modular system 7 Additional Features When your testing requires a power supply to do more than just provide a constant DC level, the N6750 Series of high-performance, autoranging DC power modules and the N6760 Series of precision DC power modules are the perfect fit. These modules combine a fast output with flexible controls and sophisticated measurements. The N6750/60 is more than a power supply; it is a stimulus/ response instrument. To fit in 1U, the N6750/60 use an advanced switch-mode design that offers the low output noise and fast output speed typically found on linear power supplies. Low noise outputs Careful attention has been paid to this design to ensure low normal mode noise (ripple and peak-peak) as well as low common mode noise. This switching power supply outperforms most linear power supplies on the market. Fast voltage changes Autoranging for flexibility When it comes to speed, the N6750 high-performance autoranging DC power modules, the N6760 precision DC power modules, and the N6780 source measure units achieve performance unlike a typical DC power supply. Thanks to an active downprogramming circuit to rapidly pull down the output when lowering the module's output voltage, these power modules can rapidly program both up and down in voltage. Changing voltage from 0 V to 50 V, or 50 V to 0 V for example, can be accomplished in less than 1.5 milliseconds. The N6750 high-performance autoranging DC power modules and the N6760 precision DC power modules give you even more flexibility by providing autoranging outputs. This autoranging capability provides maximum output power at any output voltage up to 60 V. This allows one power supply to do the job of several power supplies because its operating range covers low voltage, high current as well as high voltage, low current operating points. Note that for smaller voltage changes, from 0 V to 5 V or 5 V to 0 V for example, the programming speed is less than 200 microseconds. These output speeds allow the N6750/60/80 to give maximum system throughput when your test calls for frequent changes in power supply voltage settings. For example, the N6755A highperformance autoranging DC module, rated at 20 V, 50 A, and 500 W can provide full power at 10 V @ 50 A (= 500 W), 20 V @ 25 A (= 500 W), 15 V @ 33 A (= 500 W), or anywhere in between. Voltage Autoranging 50 W Out 50 V 50 W Curve 10 V Curre 0 1 A Figure 7. Autoranging characteristic 8 5 A Therefore, this 500 W autoranging power supply, due to its extended voltage and current range, can produce voltage and current combinations in the range of a 1000 W nonautoranging power supply. The flexibility of autoranging is useful when the DUT operates over a wide range of voltages, when the ATE system needs to test a wide range of DUTs, or when margin is needed because the ATE power supply must be selected before final DUT power requirements are determined. High-speed test extensions To make your testing go even faster, the N6700 DC power modules offer High-Speed Test Extensions (HSTE). This enhancement to the DC power modules extends the capabilities to include features similar to a built-in arbitrary waveform generator and a built-in oscilloscope. HSTE is optional on the N6730/40/50/70 DC power modules. HSTE is standard on the N6760 precision DC power modules, the N6780 SMU modules, and the N6783 application-specific modules. Through the LIST mode of HSTE, you can download up to 512 setpoints of voltage and current. In LIST mode, you can program the output to execute a LIST of voltage and current setpoints. For each setpoint, a dwell time can be specified and the power supply will stay (i.e., dwell) at that setpoint for the programmed dwell time value. For each setpoint in the LIST, you can have a different dwell time from 0 to 262 seconds with 1 microsecond resolution.* Then, you can trigger the module to begin executing the list. The module will step thru the list, staying at each setpoint for the programmed dwell time, and then it will move on to the next point. This speeds up execution by removing the computer I/O from the process. The result is an output that automatically changes according to the programmed list, just like an arbitrary waveform generator. * Note that the output response time is less than 5 milliseconds per voltage change, so steps of less than 5 milliseconds will not achieve their final output voltage value before moving on to the next step. This is useful when trying to create a smooth waveform. Voltage Time in seconds Figure 8. High speed test extensions LIST mode provides "power ARB" capability 9 HSTE also provides an oscilloscopelike digitizer built into the power module to capture voltage and current measurements of up to 524,288 points at up to 97,656 samples per second. Note that the N6780 SMUs measure at 195,312 samples per second. For applications such as design validation of battery powered digital devices, the ability to capture dynamic information about the current flowing into the DUT allows designers to better understand the current drain on DUT batteries and optimize DUT power management during normal DUT operation and in DUT standby mode. The digitizer can also be synchronized with changes in the output. For example, the digitizer can make measurements in response to a trigger generated by a change in output voltage caused by LIST mode. In this configuration, you can ensure that measurements are made at the right moment during each step of an executing LIST. This is particularly useful if you are trying to measure current consumption during a rapidly changing voltage stimulus, such as current drawn during a pulsed output voltage. Precision low-level performance The N6760 Series of Precision DC Power Modules additionally provide dual ranges on both programming and measurement. In the low range, these power supplies provide precision in the milliampere and microampere regions. They are ideally suited for semiconductor and passive device testing, or where a precisely controlled output and highly accurate, precise measurements are needed during test. Source/measure unit modules for the most demanding applications The N6780 Series of Source/Measure Units offer the highest level of performance in the N6700 Series. These SMUs feature highly accurate measurements down to nanoamperes while providing operation as a DC voltage source, DC current source, and electronic load. For details on these products and how they can be used for applications including battery drain analysis and functional test, visit www.agilent.com/find/N6780 and download the N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System Data Sheet, literature number 5990-5829EN. 10 DC Power Module Feature Map For detailed product specifications and characteristics, refer to the Agilent N6700 Modular Power System Family Specifications Guide at http://cp.literature.agilent.com/litweb/pdf/N6700-90001.pdf. Feature ( = available) DC power N673xB, N674xB, N677xA High-performance N675xA Precision N676xA N6731B - N6736B N6751A N6761A 50 W output rating 100 W output rating N6741B - N6746B N6752A N6762A 300 W output rating N6773A - N6777A N6753A, N6754A N6763A, N6764A N6755A, N6756A N6765A, N6766A 500 W output rating Output disconnect relays Option 761 Option 761 Option 761 Output disconnect/polarity reversal relays Option 760 Option 760 Option 760 Autoranging output capability Voltage or current turn-on priority N6761A, N6762A Precision voltage and current measurements Low voltage and current output ranges N6761A, N6762A Low voltage and current measurement ranges 200 A measurement range (N6761A/N6762A only) Option 2UA Simultaneous voltage and current scope traces Output list capability (High speed test extensions) Option 054 Option 054 Array readback capability (High speed test extensions) Option 054 Option 054 Programmable sample rate (High speed test extensions) Option 054 Option 054 N6753A, N6756A N6763A, N6766A Double-wide (Occupies two channel locations) Feature ( = available) N6781A N6782A N6784A N6783A-BAT N6783A-MFG Output rating 20 W 20 W 20 W 24 W 18 W 2-quadrant operation Source/measure units (SMU) 4-quadrant operation Application-specific Auxiliary voltage measurement input Output disconnect relays Option 761 Option 761 Negative voltage protection Voltage or current priority mode Programmable output resistance 600 mV output range 300 mA output range 100 mA, 10 mA output ranges 1 V, 100 mV measurement ranges 100 mA, 1 mA, 10 A measurement ranges 150 mA measurement range Simultaneous voltage and current measurements Seamless measurement autoranging Output list capability Array readback capability Programmable sample rate 11 DC Power Module Key Performance Specifications Note: This data sheet does not include a comprehensive list of all power module specifications and characteristics. Complete performance specifications and supplemental characteristics for all power modules can be found at http://cp.literature.agilent.com/litweb/pdf/N6700-90001.pdf. See the Agilent N6700 Modular Power System Family Specifications Guide, part number N6700-90001. DC output ratings (volts/amps/watts) Ripple & noise (p-p/rms) Voltage programming accuracy Current programming accuracy Voltage measurement accuracy Current measurement accuracy N6731B 5 V/10 A/50 W 10 mV/2 mV 0.1% + 19 mV 0.15% + 20 mA 0.1% + 20 mV 0.15% + 20 mA N6732B 8 V/6.25 A/50 W 12 mV/2 mV 0.1% + 19 mV 0.15% + 20 mA 0.1% + 20 mV 0.15% + 10 mA N6733B 20 V/2.5 A/50 W 14 mV/3 mV 0.1% + 20 mV 0.15% + 20 mA 0.1% + 20 mV 0.15% + 5 mA N6734B 35 V/1.5 A/52.5 W 15 mV/5 mV 0.1% + 35 mV 0.15% + 20 mA 0.1% + 35 mV 0.15% + 4 mA N6735B 60 V/0.8 A/50 W 25 mV/9 mV 0.1% + 60 mV 0.15% + 20 mA 0.1% + 60 mV 0.15% + 4 mA N6736B 100 V/0.5 A/50 W 30 mV/18 mV 0.1% + 100 mV 0.15% + 10 mA 0.1% + 100 mV 0.15% + 2 mA N6741B 5 V/20 A/100 W 20 mV/2 mV 0.1% + 19 mV 0.15% + 20 mA 0.1% + 20 mV 0.15% + 20 mA N6742B 8 V/12.5 A/100 W 12 mV/2 mV 0.1% + 19 mV 0.15% + 20 mA 0.1% + 20 mV 0.15% + 10 mA N6743B 20 V/5 A/100 W 14 mV/3 mV 0.1% + 20 mV 0.15% + 20 mA 0.1% + 20 mV 0.15% + 5 mA N6744B 35 V/3 A/105 W 15 mV/5 mV 0.1% + 35 mV 0.15% + 20 mA 0.1% + 35 mV 0.15% + 4 mA N6745B 60 V/1.6 A/100 W 25 mV/9 mV 0.1% + 60 mV 0.15% + 20 mA 0.1% + 60 mV 0.15% + 4 mA N6746B 100 V/1 A/100 W 30 mV/18 mV 0.1% + 100 mV 0.15% + 10 mA 0.1% + 100 mV 0.15% + 2 mA N6751A 50 V/5 A/50 W 4.5 mV/0.35 mV 0.06% + 19 mV 0.1% + 20 mA 0.05% + 20 mV 0.1% + 4 mA N6752A 50 V/10 A/100 W 4.5 mV/0.35 mV 0.06% + 19 mV 0.1% + 20 mA 0.05% + 20 mV 0.1% + 4 mA N6753A 20 V/50 A/300 W 5 mV/1 mV 0.06% + 10 mV 0.1% + 30 mA 0.05% + 10 mV 0.1% + 30 mA N6754A 60 V/20 A/300 W 6 mV/1 V 0.06% + 25 mV 0.1% + 12 mA 0.05% + 25 mV 0.1% + 8 mA N6755A 20 V/50 A/500 W 5 mV/1 mV 0.06% + 10 mV 0.1% + 30 mA 0.05% + 10 mV 0.1% + 30 mA N6756A 60 V/17 A/500 W 6 mV/1 V 0.06% + 25 mV 0.1% + 12 mA 0.05% + 25 mV 0.1% + 8 mA N6761A 1 50 V/1.5 A/50 W 4.5 mV/0.35 mV 0.016% + 6 mV 0.04% + 0.2 mA 0.016% + 6 mV 0.04% + 0.16 mA N6762A 1 0.016% + 6 mV 0.04% + 0.2 mA 0.016% + 6 mV 0.04% + 0.16 mA 50 V/3 A/100 W 4.5 mV/0.35 mV 1 20 V/50 A/300 W 5 mV/1 mV 0.03% + 5 mV 0.1% + 15 mA 0.03% + 10 mV 0.1% + 10 mA N6764A 1 60 V/20 A/300 W 6 mV/1 V 0.03% + 12 mV 0.1% + 15 mA 0.03% + 25 mV 0.1% + 5 mA 1 20 V/50 A/500 W 5 mV/1 mV 0.03% + 5 mV 0.1% + 15 mA 0.03% + 10 mV 0.1% + 10 mA N6766A 1 60 V/17 A/500 W 6 mV/1 V 0.03% + 12 mV 0.1% + 15 mA 0.03% + 25 mV 0.1% + 5 mA N6773A 20 V/15 A/300 W 20 mV/3 mV 0.1% + 20 mV 0.15% + 60 mA 0.1% + 20 mV 0.15% + 15 mA N6774A 35 V/8.5 A/300 W 22 mV/5 mV 0.1% + 35 mV 0.15% + 60 mA 0.1% + 35 mV 0.15% + 12 mA N6775A 60 V/5 A/300 W 35 mV/9 mV 0.1% + 60 mV 0.15% +60 mA 0.1% + 60 mV 0.15% +12 mA N6776A 100 V/3 A/300 W 45 mV/18 mV 0.1% + 100 mV 0.15% + 30 mA 0.1% + 100 mV 0.15% + 6 mA N6777A 150 V/2 A/300 W 68 mV/27 mV 0.1% + 150 mV 0.15% + 30 mA 0.1% + 150 mV 0.15% + 6 mA N6763A N6765A N6781A 1 N6782A 1 N6784A 1 N6783A-BAT 2 20 V/ 3 A/20 W 12 mV/1.2 mV 0.025% + 1.8 mV 0.04% + 0.3 mA 0.025% + 1.2 mV 0.03% + 0.25 mA 20 V/3 A/20 W 12 mV/1.2 mV 0.025% + 1.8 mV 0.04% + 0.3 mA 0.025% + 1.2 mV 0.03% + 0.25 mA 20 V/ 3 A/20 W 12 mV/1.2 mV 8 V/-2 A to 3 A/24 W 8 mV/1.5 mV N6783A-MFG 2 6 V/-2 A; 3 A/18 W 8 mV/1.5 mV 0.025% + 1.8 mV 0.04% + 0.3 mA 0.025% + 1.2 mV 0.03% + 0.25 mA 0.1% + 10 mV 0.1% + 1.8 mA 0.05% + 5 mV 0.1% + 0.6 mA 0.1% + 10 mV 0.1% + 1.8 mA 0.05% + 5 mV 0.1% + 0.6 mA 1 These power modules have multiple output and measurement ranges; values shown are for the highest range. 2 These power modules have multiple measurement ranges; values shown are for the highest range. 12 DC Power Analyzer Mainframe Key Characteristics Interface capabilities GPIB SCPI - 1993, IEEE 488.2 compliant interface LXI compliance Class C USB 2.0 Requires Agilent IO Library version M.01.01 or 14.0 and up 10/100 LAN Requires Agilent IO Library version L.01.01 or 14.0 and up Environmental conditions Operating environment Indoor use, installation category II (for AC input), pollution degree 2 Temperature range 0 C to 55 C (output current is derated 1% per C above 40 C ambient temperature) Relative humidity Up to 95% Altitude Up to 2000 meters AC input Input ratings ~ 100 VAC - 240 VAC; 50/60/400 Hz Power consumption 1000 VA (N6700B) 1440 VA (N6701A) 1440 VA (N6702A @ < 180 VAC input) 2200 VA (N6702A @ > 180 VAC input) Power factor 0.99 @ nominal input and rated power Net weight N6700B with 4 modules (typical) 12.73 kg/28 lbs. N6701A with 4 power modules 11.82 kg/26 lbs. N6702A with 4 power modules 14.09 kg/31 lbs. Dimensions N6700B /N6701A N6702A Height/width/depth 44.45 mm/432.5 mm/585.6 mm 1.75 in./17.03 in./23.06 in. 44.45 mm/432.5 mm/633.9 mm 1.75 in./17.03 in./24.96 in. 13 Ordering Information The DC power analyzer system is available two ways 1. You can order an N6700B, N6701A or N6702A mainframe and various modules as separate products. (See steps below.) Each item will arrive in a separate box so that you can assemble the system yourself. 2. You can order an N6710B, N6711A or N6712A system, which is a build-to-order system that is shipped as a fully assembled multiple-output power supply. (See pages 18 and 19 for N6710B, N6711A and N6712A ordering information. When ordering the N6700 MPS as a mainframe and modules, follow these steps. Step 4 For proper operation, you must fill any empty module slots with filler panels. When configuring a mainframe with less than four filled module slots, you MUST order a filler panel kit. Each kit contains three filler panels. Each filler panel fills one empty module slot. Step 5 If you will be rack mounting your N6700, you MUST order the rack mount kit. Mainframes N6700B Low-profile modular power system mainframe, 400 W Holds 1 to 4 modules. Total available output power = 400 W N6701A Low-profile modular power system mainframe, 600 W Holds 1 to 4 modules. Total available output power = 600 W N6702A Low-profile modular power system mainframe, 1200 W Holds 1 to 4 modules. Total available output power = 1200 W Available options to the N6710B, N6711A, and N6712A systems Step 1 N6709A Rack mount kit Required for rack mounting. Standard rack mount hardware will not work. N6708A Filler panel kit Required when you have less than 4 modules in a mainframe. Each filler kit contains 3 filler panels. OL1 Full documentation on CD-ROM and printed users guide 900 Power cord, United Kingdom, P/N 8120-1351 901 Power cord, Australia, New Zealand, P/N 8120-1369 902 Power cord, Europe, Korea, P/N 8120-1689 903 Power cord, USA, Canada, 120 V, P/N 8120-4383 904 Power cord, USA, Canada, 240 V, P/N 8120-0698 906 Power cord, Switzerland, P/N 8120-2104 912 Power cord, Denmark, P/N 8120-2956 917 Power cord, South Africa, India, P/N 8120-4211 918 Power cord, Japan, 100 V, P/N 8120-5342 Note: For model N6712A, the maximum output power is limited to 600 W at 100 VAC. To achieve full output power of 1200 W, you must use option 929 and operate at 200 VAC. 919 Power cord, Israel, P/N 8120-6800 920 Power cord, Argentina, P/N 8120-6869 921 Power cord, Chile, P/N 8120-6980 922 Power cord, China, P/N 8120-8376 927 Power cord, Thailand, Brazil, P/N 8120-8871 929 Power cord, Japan, 200 V, P/N 8121-1392 Note: This option is available only on model N6702A Select which mainframe you want based on your power requirements. Step 2 Select the appropriate documentation and line cord options. Step 3 Order 1 to 4 modules (see next page). If the sum of the power of the modules exceeds the available output power rating on the mainframe, see page 4 for an explanation of Agilent's power management capability. Each module occupies one module slot, except for the N6753A-N6756A and N6763A-N6766A which occupy two module slots. 14 Ordering Information, continued Modules Modules Order 1 to 4 modules to be installed in each N6700B, N6701A or N6702A mainframe. (To order modules as part of the N6710B, N6711A or N6712A build-to-order systems, see page 18). If the sum of the power of the modules exceeds the available output power rating on the mainframe, see page 4 for an explanation of Agilent's power management capability. N6730 50 W DC power modules You can individually specify each option for each module. For example, you can order one module with Option 761 Output Disconnect Relays while the remaining modules have no relay options. N6740 100 W DC power modules N6750 highperformance, auto-ranging DC power modules As your needs change and you want to change configuration or add more modules to existing N6700A, N6700B, N6701A or N6702A mainframes, use this ordering information to order the required modules. N6760 precision DC power modules N6770 300 W DC power modules N6780 ~20 W applicationspecific modules N6731B 5 V, 10 A, 50 W DC power module N6732B 8 V, 6.25 A, 50 W DC power module N6733B 20 V, 2.5 A, 50 W DC power module N6734B 35 V, 1.5 A, 50 W DC power module N6735B 60 V, 0.8 A, 50 W DC power module N6736B 100 V, 0.5 A, 50 W DC power module N6741B 5 V, 20 A, 100 W DC power module N6742B 8 V, 12.5 A, 100 W DC power module N6743B 20 V, 5 A, 100 W DC power module N6744B 35 V, 3 A, 100 W DC power module N6745B 60 V, 1.6 A, 100 W DC power module N6751A 50 V, 1.5 A, 50 W high-performance autoranging DC power module N6752A 50 V, 1.5 A, 50 W high-performance autoranging DC power module N6753A 20 V, 50 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6754A 60 V, 20 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6755A 20 V, 50 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6756A 60 V, 17 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6761A 50 V, 1.5 A, 50 W precision DC power module N6762A 50 V, 3 A, 100 W precision DC power module N6763A 20 V, 50 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots) N6764A 60 V, 20 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots) N6765A 20 V, 50 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots) N6766A 60 V, 17 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots) N6773A 20 V, 15 A, 300 W DC power module N6774A 35 V, 8.5 A, 300 W DC power module N6775A 60 V, 5 A, 300 W DC power module N6776A 100 V, 3 A, 300 W DC power module N6777A 150 V, 2 A, 300 W DC power module N6781A 20 V, 3 A, 20 W source/measure unit N6782A 20 V, 3 A, 20 W source/measure unit N6784A 20 V, 3 A, 20 W source/measure unit N6783A-BAT 8 V, 3 A, 24 W battery charge/discharge module N6783A-MFG 6 V, 3 A, 18 W mobile communications module 15 Ordering Information, continued Available options to N6700 modules N6731BN6736B 50 W DC power modules N6741BN6746B 100 W DC power modules N6751AN6756A highperformance autoranging DC power modules N6761AN6766A precision DC power modules N6773AN6776A 300 W DC power modules N6781A, N6782A, N6784A SMU modules N6783A-BAT N6783A-MFG applicationspecific Output disconnect relays 761 761 761 761 761 Standard 761 Output disconnect and polarity reversal relays 760 760 1, 2 760 1 760 1 760 2 Not available Not available High speed test extensions (HSTE) 054 054 054 Standard 054 Standard Standard Not available Not available Not available 2UA 3 Not available Not available Not available Commercial calibration with test results data UK6 UK6 UK6 UK6 UK6 UK6 UK6 ISO 17025 calibration certificate 1A7 1A7 1A7 1A7 1A7 Not available 1A7 200 microampere measurement range 1. Option 760 is not available on Models N6741B, N6751A, N6752A, N6761A, N6762A. 2. Option 760 limits the output current to 10 A maximum on Models N6742B and N6773A. 3. Option 2UA is only available on Models N6761A and N6762A. 16 N6700 build-to-order system Build-to-order system To purchase an N6700 system, order an N6710B, N6711A, or N6712A. These model numbers are build-toorder systems that are shipped as a fully tested and assembled multipleoutput power supplies. Each system consists of one mainframe plus optionally 1 to 4 modules. Each mainframe has four module slots to hold modules. Each module occupies one module slot, except for the N6753A-N6755A and the N6763A- N6766A, which occupy two module slots. To specify which modules you want installed in the system, the modules are ordered as options to the system model number If you order less than four modules, the empty slots will be automatically filled with blank filler panels. You must order at least one module. N6710B System Build-to-order modular power system, 400 W Consists of 1 N6700B mainframe with total available power of 400 W N6711A System Build-to-order modular power system, 600 W Consists of 1 N6701A mainframe with total available power of 400 W N6712A System Build-to-order modular power system, 1200 W Consists of 1 N6702A mainframe with total available power of 1200 W If the sum of the power of the modules exceeds the available output power rating on the mainframe, see page 4 for an explanation of Agilent's power management capability. If you prefer to purchase a mainframe and modules as separate pieces, see page 16. Available options to the N6715B system N6709A Rack mount kit Required for rack mounting. Standard rack mount hardware will not work Full documentation on CD-ROM and printed users guide OL1 Full documentation on CD-ROM and printed users guide 900 Power cord, United Kingdom, P/N 8120-1351 901 Power cord, Australia, New Zealand, P/N 8120-1369 902 Power cord, Europe, Korea, P/N 8120-1689 903 Power cord, USA, Canada, 120 V, P/N 8120-4383 904 Power cord, USA, Canada, 240 V, P/N 8120-0698 906 Power cord, Switzerland, P/N 8120-2104 912 Power cord, Denmark, P/N 8120-2956 917 Power cord, South Africa, India, P/N 8120-4211 918 Power cord, Japan, 100 V, P/N 8120-5342 Note: For model N6712A, the maximum output power is limited to 600 W at 100 VAC. To achieve full output power of 1200 W, you must use option 929 and operate at 200 VAC. 919 Power cord, Israel, P/N 8120-6800 920 Power cord, Argentina, P/N 8120-6869 921 Power cord, Chile, P/N 8120-6980 922 Power cord, China, P/N 8120-8376 927 Power cord, Thailand, Brazil, P/N 8120-8871 929 Power cord, Japan, 200 V, P/N 8121-1392 Note: This option is available only on model N6712A 17 Ordering Information, continued Modules as options to N6710B, N6711A, or N6712A Order 1 to 4 modules as options to an N6710B, N6711A or N6712A, specify its model number, followed by "-ATO." For example, to order an N6731B as an option to the N6710B, you would specify "-ATO." For example, to order an N6731B as an option to the N6710B, you would specify "N6731BATO"as the option. (To order modules as separate products, see page 16). If the sum of the power of the modules exceeds the available output power rating on the mainframe, see page 4 for an explanation of Agilent's power management capability. You can individually specify each option for each module. For example, you can order one module with Option 761 Output Disconnect Relays while the remaining modules have no relay options. Module options for N6710B, N6711A, and N6712A systems N6730 50 W DC power modules N6740 100 W DC power modules N6750 highperformance, auto-ranging DC power modules N6760 precision DC power modules N6770 300 W DC power modules N6780 ~20 W applicationspecific modules N6731B-ATO 5 V, 10 A, 50 W DC power module N6732B-ATO 8 V, 6.25 A, 50 W DC power module N6733B-ATO 20 V, 2.5 A, 50 W DC power module N6734B-ATO 35 V, 1.5 A, 50 W DC power module N6735B-ATO 60 V, 0.8 A, 50 W DC power module N6736B-ATO 100 V, 0.5 A, 50 W DC power module N6741B-ATO 5 V, 20 A, 100 W DC power module N6742B-ATO 8 V, 12.5 A, 100 W DC power module N6743B-ATO 20 V, 5 A, 100 W DC power module N6744B-ATO 35 V, 3 A, 100 W DC power module N6745B-ATO 60 V, 1.6 A, 100 W DC power module N6751A-ATO 50 V, 1.5 A, 50 W high-performance autoranging DC power module N6752A-ATO 50 V, 1.5 A, 50 W high-performance autoranging DC power module N6753A-ATO 20 V, 50 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6754A-ATO 60 V, 20 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6755A-ATO 20 V, 50 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6756A-ATO 60 V, 17 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6761A-ATO 50 V, 1.5 A, 50 W precision DC power module N6762A-ATO 50 V, 3 A, 100 W precision DC power module N6763A-ATO 20 V, 50 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots) N6764A-ATO 60 V, 20 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots) N6765A-ATO 20 V, 50 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots) N6766A-ATO 60 V, 17 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots) N6773A-ATO 20 V, 15 A, 300 W DC power module N6774A-ATO 5 V, 8.5 A, 300 W DC power module N6775A-ATO 60 V, 5 A, 300 W DC power module N6776A-ATO 100 V, 3 A, 300 W DC power module N6777A-ATO 150 V, 2 A, 300 W DC power module N6781A-ATO 20 V, 3 A, 20 W source/measure unit N6782A-ATO 20 V, 3 A, 20 W source/measure unit N6784A-ATO 20 V, 3 A, 20 W source/measure unit N6783A-BAT 8 V, 3 A, 24 W battery charge/discharge module N6783A-MFG 6 V, 3 A, 18 W mobile communications module 18 Need a power solution for R&D bench work? The Agilent N6705B DC Power Analyzer saves time * Provides unrivaled productivity gains for sourcing and measuring DC voltage and current into your DUT by integrating up to 4 advanced power supplies with DMM, scope, arb, and data logger features. * Eliminates the need to gather multiple pieces of equipment, create complex test setups including transducers (such as current probes and shunts) to measure current into your DUT. * Eliminates the need to develop and debug programs to control a collection of instruments and take useful measurements because all the functions and measurements are available at the front panel. * Modular system: Uses the same DC power modules at the N6700 low-profile modular power system Complete specifications can be found in the N6705B DC Power Analyzer Data Sheet, publication 5989-6319EN. For more information go to www.agilent.com/find/dcpoweranalyzer Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.axiestandard.org AdvancedTCA(R) Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium. Agilent Advantage Services is committed to your success throughout your equipment's lifetime. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair and reduce your cost of ownership. You can also use Infoline Web Services to manage equipment and services more effectively. By sharing our measurement and service expertise, we help you create the products that change our world. www.agilent.com/find/advantageservices www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. For more information on Agilent Technologies' products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 (11) 4197 3600 01800 5064 800 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 45 80 12 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany Ireland Israel Italy Netherlands Spain Sweden United Kingdom 49 (0) 7031 464 6333 1890 924 204 972-3-9288-504/544 39 02 92 60 8484 31 (0) 20 547 2111 34 (91) 631 3300 0200-88 22 55 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus Revised: January 6, 2012 Agilent Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management Sys System www.agilent.com/quality Agilent Channel Partners www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based highperformance measurement and automation system. www.agilent.com www.agilent.com/find/n6700 www.agilent.com/find/channelpartners Get the best of both worlds: Agilent's measurement expertise and product breadth, combined with channel partner convenience. Product specifications and descriptions in this document subject to change without notice. (c) Agilent Technologies, Inc. 2012 Published in USA, July 31, 2012 5989-1411EN