R
Long Range Ultrasonic Sensor E4R
Sensing Distance Adjustable
to 2.5 m
HMutual interference protection
HWide beam angle ideal for detecting
granular or high-viscosity materials
HCompact sensing head with separate
controller
Orderin
g
Information
JSENSOR SYSTEM
Description Part number
Ultrasonic sensing head E4R-A
Controller for sensing head E4R-2
Reference pulse unit to synchronize multiple sensors E4R-SP
Switching power supply to power controller E4R-2 S82K-00312
JREPLACEMENT PARTS
Description Part number
Socket for E4R-2 controller; mounts to panel or on DIN-rail track 14PFA
Socket for E4R-SP reference pulse unit 8PFA
Specifications
JSENSING HEAD
Part number E4R-A
Sensing method Reflective
Sensing distance 0.7 to 2.5 m (2.30 to 8.20 ft), adjustable
Standard sensing object 200 x 200 mm flat plate
Ultrasonic oscillation frequency 40 ±2kHz
Directional angle ±20°
Indicator —
Ambient operating temperature -- 2 5 °Cto55°C(--13°F to 131°F)withnoicing
Relative humidity 45% to 85% with no condensation
Vibration resistance 10 to 25 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z axes
Shock resistance 100 m/s2(approx. 10 G) 10 times each in X, Y, and Z axes
(This table continues on the next page.)
E4RE4R
2
Specifications Table -- continued from previous page
Part number E4R-A
Cable length Use shielded cable, 20 m (65.62 ft) max. between sensor and controller
Weight Approx. 400 g
Material Plastic
Temperature influence ±5% max. of sensing distance within the temperature range of --10°Cto40°C(14°F to 104°F)
Voltage influence ±5% max. of sensing distance within the permissible power supply voltage
JCONTROLLER
Part number E4R-2
Supply voltage 12 VDC ±15%
Current consumption Approx. 1.5 W (120 mA DC)
Response time ON: 150 ms; OFF time: 500 ms
Control output SPDT contact, 4 A at 220 VAC/24 VDC
Operation mode NO and NC switch selectable
indicator POWER and DETECT indicators
Ambient operating temperature -- 1 0 °Cto40°C(14°F to 104°F)
Relative humidity 45% to 85% with no condensation
Insulation resistance 20 MΩmin. at 500 VDC between current carrying parts and case
Dielectric strength 1500 VAC 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 25 Hz, 1.5-mm double amplitude for 2 hours each in X,Y and Z axes
Shock resistance 100 m/s2(approx. 10 G) 10 times each in X, Y, and Z axes
Enclosure rating IP10
Weight 400 g
En
g
ineerin
g
Data
JOPERATING RANGE DIAGRAMS (TYPICAL)
Distance (m)
Adjusted for 2.5
Adjusted for
1m
E4R sensor
30-mm dia. Rod
Operating width (mm)
30 mm dia. rod
200 x 200 mm Plastic Plate
Operating width (mm)
E4R sensor
Adjusted
for 1 m
Adjusted for 2.5 m
200 x 200 mm
plastic plate
Distance (m)
E4R E4R
3
Dimensions
Unit: mm (inch)
JE4R-A SENSOR
Mounting Bracket
Three, 5.5 dia.
46 max.
(1.81)
70 max.
(2.76)
88 max.
52
(2.05)
20
80 (3.15)
40
80
12
22.5
20
30_
JE4R-2 CONTROLLER
Note: The dimensions are external
dimensions that include the 14PFA
Surface-mounting Socket.
14PFA Socket
The 14PFA Surface-mounting Socket is provided with the E4R-2.
80.5 max.
87 max.
(3.43)
118 max.
72
(2.83)
71
60
(2.36)
4
112
(4.41)
30±1
JE4R-SP REFERENCE PULSE UNIT
Note: The 8PFA Surface-mounting Socket is provided with the E4R-SP.
82 max.
(3.29) 62.5 max.
(2.46)
50 max.
(1.97) 90 max.
(3.54)
53.5 73.4 78.2
62
E4RE4R
4
J14PFA PANEL AND DIN TRACK MOUNTING SOCKET (ORDER SEPARATELY)
14, M3.5 x 7 sems screws
Two, 4.5-dia.
holes
Terminal Arrangement and
Internal Connections (Top View)
Mounting Holes
Two, M4 or 4.5-dia. holes
Note: DIN track mounting is possible.
72 max.
(2.83)
81 max.
(3.19)
33.5 max.
(
1.32
)
118 max.
(4.65)
7.8
4
60±0.2
(2.36)
54
4
35.4
60±0.2
Installation
JCONNECTIONS
E4R-A/E4R-2
Sensor 1
Sensor 2
E4R-A
Use shielded cables for the oscillator’s transmission line
(connected to the OSC terminals) and the reception line
(connected to the REC terminals). Each cable must be a
maximum of 20 m in length.
The shielded cables connecting the Sensor and terminals 7, 14,
and 6 (or 5, 12, and 4) must be all parallel conductors with 11
strands of 0.16-mm dia. each with all conductors shielded
independently. The cable connected to terminal 3 must be a
single-conductor cable that is 0.2 to 0.3 mm2in size.
Note: 1. Sensors 1 and 2 are in OR operation.
2. If only a single Sensor is connected, leave the termi-
nals for the other Sensor open.
3. Set the slide switch to CLOSE.
Note: CHECK terminal allows connection of oscilloscope for
trouble shooting ultrasonic signal.
E4R E4R
JREFERENCE PULSE UNIT
Use the E4R-SP Reference Pulse Unit when more than one E4R-2 PowerSupply Unit is applied to a single application.The E4R-SP generates
reference pulses that synchronize a maximum of ten E4R-2 Power Supply Units in operation without mutual interference.
Reference
pulse signal
Sensor 1
Sensor 1
Sensor 2
Note: 1. Sensors 1 and 2 are in OR operation.
2. Set the slide switch of the E4R-2 to OPEN.
Sensor 2
Set the slide switch to E4R-2.
Supply 100 VAC or 12 VDC.
Reference
pulse signal
E4R-A
E4R-A
100 VAC
Precautions
JPOWER SUPPLY
If a switching power supply is to be used, the FG and G terminals
must be grounded.
E4R-2
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A.
OMRONELECTRONICSLLC
One EastCommerceDrive
Schaumburg, IL 60173
NOTE:DIMENSIONS SHOWN AREINMILLIMETERS.To convertmillimeterstoinches divideby 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 MilnerAvenue
Scarborough,OntarioM1B5V8
416-286-6465
R
OMRONON--LINE
Global-- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci