HE-S (AHES3, 4)
–3– ASCTB360E 201604-T
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. Coil holding voltage is the coil voltage after 100 ms from the applied nominal coil voltage.
*4. Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions.
*5. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*6. Regarding Form B contact, only the 2 Form A 1 Form B type applies.
Characteristics Item Specifications
Standard type Long life type
Contact
Arrangement 2 Form A, 2 Form A 1 Form B 2 Form A, 2 Form A 1 Form B
Form A
contact
Contact resistance (Initial) Max. 100mΩ (By voltage drop 6V DC 1A),
Max. 3mΩ (By voltage drop 6V DC 20A, Reference value)
Contact material AgSnO2 type
Form B
contact*6
Contact resistance (Initial) Max. 100mΩ (By voltage drop 6V DC 1A)
Contact material Au flashed AgNi type
Rating
Form A
contact
Nominal switching capacity
(Resistive load) 35A 277V AC
Max. switching voltage 480V AC, 110V DC
Contact carring power
(Resistive load) 9,695VA
Max. switching current 35A
Min. switching capacity
(Reference value)*1100mA 5V DC
Form B
contact*6
Nominal switching capacity
(Resistive load) 1A 277V AC, 1A 30V DC
Max. switching voltage 277V AC, 30V DC
Contact carring power
(Resistive load) 277VA
Max. switching current 1A
Min. switching capacity
(Reference value)*110mA 5V DC
Nominal operating power 1,880mW (after applying min.100ms coil nominal voltage)
170mW (30%V of coil holding voltage)
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500 V DC) Measurement at same location as “Breakdown voltage” section.
Short current (A contact, Initial) Max. 1,000A 1 ms, 3 times (Reference value)
Breakdown
voltage
(Initial)
Between open Form A contacts 2,000 Vrms for 1 min. (Detection current: 10mA)
Between Form A contact and coil 5,000 Vrms for 1 min. (Detection current: 10mA)
Between Form A contact sets 5,000 Vrms for 1 min. (Detection current: 10mA)
Between open Form B contacts 1,000 Vrms for 1 min. (Detection current: 10mA)
Between Form B contact and coil 2,000 Vrms for 1 min. (Detection current: 10mA)
Between Form A contact and
Form B contact 5,000 Vrms for 1 min. (Detection current: 10mA)
Surge breakdown voltage*2
(Between contact and coil)
10,000V (Between Form A contact and coil) (Initial)
2,500V (Between Form B contact and coil) (Initial)
Coil holding voltage*330 to 110%V (Form A contact carrying current: 35A, at –40 to +55°C –40 to +131°F)
30 to 60%V (Form A contact carrying current: 35A, at –40 to +85°C –40 to +185°F)
Operate time (at 20°C 68°F) (Initial) Max. 30 ms (at nominal coil voltage, excluding contact bounce time)
Release time (at 20°C 68°F)*4 (Initial) Max. 10 ms (at nominal coil voltage, excluding contact bounce time, without diode)
Mechanical
characteristics
Shock
resistance
Functional 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10 μs)
Destructive 980 m/s2 (Half-wave pulse of sine wave: 6 ms)
Vibration
resistance
Functional 10 to 55 Hz at double amplitude of 1.0 mm .039 inch (Detection time: 10 μs)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm .059 inch
Expected life
Mechanical Min. 5×106 (at 180 times/min.)
Electrical
(Form A
contact)
Resistive load
Min. 3×104 (35A 277V AC) (ON : OFF = 1s : 9s) Min. 5×104 (35A 277V AC) (ON : OFF = 1s : 9s)
— Min. 1×105 (30A 220V AC) (ON : OFF = 1s : 9s)
Min. 1×105 (20A 277V AC) (ON : OFF = 1s : 9s) Min. 2×105 (20A 277V AC) (ON : OFF = 1s : 9s)
Inductive load Min. 3×104 (35A 250V AC) (cos
φ
= 0.8)
(ON : OFF = 0.1s : 10s)
Min. 5×104 (35A 250V AC) (cos
φ
= 0.8)
(ON : OFF = 0.1s : 10s)
Electrical
(Form B
contact)*6
Resistive load Min. 1×105 (1A 277V AC) (ON : OFF = 1s : 9s)
Min. 1×105 (1A 30V DC) (ON : OFF = 1s : 9s)
Conditions Conditions for operation, transport and storage*5
Temperature: –40 to +55°C –40 to +131°F (Coil holding voltage 30 to 110%V)
Temperature: –40 to +85°C –40 to +185°F (Coil holding voltage 30 to 60%V or storage)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Air pressure: 86 to 106 kPa
Unit weight Approx. 64 g 2.26 oz