477
Amphenol
Contact Amphenol Aerospace for more information at 800-678-0141 • www.amphenol-aerospace.com
II
Dualok
III
SJT
38999
I
PCB
Accessories
Aquacon
HD
EMI Filter
Transient
Herm/Seal
Fiber
Optics
Contacts
Connectors
Cables
HIgH
SPEED
26482
Matrix 2 83723 III
Matrix|Pyle
5015
Crimp Rear
Release
Matrix
26500
Pyle 22992
Class L Back-
Shells
Options
Others
MIL-DTL-22992, Class L
Installation Instructions, cont.
Contact
Part Number Size Type Crimping
Tool* Locator* Die* Removal
Tool
M39029/48-327
M39029/49-335
M39029/48-328
4/0
4/0
4/0N
P
S
P
Pico Model 400B
or
400B-1
4297-1 414DA-4/0N-1 MS90562-1
M39029/48-323
M39029/49-333
M39029/48-324
1/0
1/0
1/0N
P
S
P
Pico Model 400B
or
400B-1
4297-3 414DA-1/0N MS90562-3
M39029/48-320
M39029/49-331
M39029/48-321
M39029/48-322
M39029/49-332
4
4
4N
4G
4G
P
S
P
P
S
Pico Model 400B
or
400B-1
4297-5 414DA-4N MS90562-5
M39029/48-317
M39029/49-329
M39029/48-318
M39029/48-319
M39029/49-330
6
6
6N
6G
6G
P
S
P
P
S
Pico Model 400B
or
400B-1
4297-6 414DA-6N MS90562-6
* Available from Pico Crimping Tools Co.,
9832 Jersey Ave., Santa Fe Springs, Ca
90670
Phone: 805-388-5510
Order MS90562 contact Removal Tool by MS part
number listed below:
MS Part
Number
Contact
Size
A Dia.
+.000
–.002
M81969/27-01 4/0 .790
M81969/27-02 2/0 .696
M81969/27-03 1/0 .558
M81969/27-04 2.462
M81969/27-05 4.376
M81969/27-06 6.354
MS90562 Contact Removal Tool
A
2.500 ±.016
All dimensions for reference only.
Contact Removal
Step 1) Loosen all rear accessories and slide back along cable.
Step 2) Remove spacer or grommet assembly with contacts
from connector insert.
Step 3) Using the appropriate size contact removal tool, push
tool over front of contact until it bottoms in spacer or
grommet assembly hole. This will open contact retaining
bushing and allow contact to be removed from the
spacer or grommet assembly from the rear. When using
jacketed cable, all contacts should be released from
contact retention bushings before removal from spacer
or grommet assembly is accomplished.
Connector Assembly
Step 1) If inserts are not already positioned in the
connector shell, align large tab on insert with
large slot in shell and push insert in until it
bottoms in shell.
Step 2) Apply a thin coating of Dow Corning DC-4
lubricant to the periphery of contact holes in
spacer or grommet assembly. Push contacts into
rear of spacer or grommet assembly until locked
into contact retainer bushing.
Step 3) Align contacts with proper holes in insert. Small
key of insert must be aligned with appropriate
keyway in spacer or grommet assembly. Slide
contacts into insert holes until spacer or grommet
assembly butts against insert. A thin lm of Dow
Corning DC-4 lubricant applied to the periphery
of insert contact holes will provide maximum
sealing efciency.
Step 4) Assemble accessories to connector. The back
adapter “O” ring should have a very thin lm of
Dow Corning DC-4 lubricant applied. Outer
surfaces only of gland should be lubricated with a
thin lm of UniTemp Grease EP. Avoid getting
grease on inside surfaces of gland and on cable
jacket.
Step 5) Tighten retaining nut or gland nut on shell or
adapter. A metal-to-metal seating condition is
desirable, but may not be attainable with
maximum cable diameters.
If crimping tools are available, contacts may be
afxed to conductors by soldering. Use rosin-alcohol
solder ux, a good grade of 60/40 solder and a 500
watt soldering iron or probe type resistance
soldering equipment. Pre-tin conductors before
soldering. Solder must not be present on shoulder or
retention area of contact.
Contact Installation
Step 1) Insert stripped conductors in contact wirewells. If contact bushing is used, insert
conductor in bushing and bushing in contact wirewell. If two or more ground wires
are inserted into a single contact, make sure all wires are fully seated in wirewell.
Step 2) Select correct crimping tool, locator and die combination from the table for contacts
to be installed. With conductor or contact bushing in place, insert contact into tool.
Close crimping die fully to form a uniform crimp.