Procedure
The MAX1416 EV kit is fully assembled and tested.
Follow the steps below to verify board operation.
Caution: Do not turn on the power until all connec-
tions are completed.
1) Visit the Maxim website (www.maxim-ic.com/evkitsoft-
ware) to download the latest version of the EV kit soft-
ware. Save the EV kit software to a temporary folder
and uncompress the file (if it is a .zip file).
2) Install the MAX1416 EV kit software on your computer
by running the INSTALL.EXE program. The program
files are copied and icons are created for them in the
Windows Start | Programs menu.
3) Ensure that jumpers JU1, JU2, and JU4 are closed
and that jumper JU3 is in the 1-2 position (see Table
1 for jumper settings).
4) Carefully connect the boards by aligning the 40-pin
header of the MAX1416 EV kit with the 40-pin con-
nector of the 68HC16MODULE-DIP module. Gently
press them together. The two boards should be flush
against one another.
5) Connect the +5VDC power source to the MAX1416
EV kit at terminal block TB1. Observe the polarity
marked on the board.
6) Connect the +7VDC to +20VDC power source to the
µC module at the terminal block located next to the
on/off switch, along the top-edge of the µC module.
Observe the polarity marked on the board.
7) Connect a cable from the computer’s serial port to
the µC module. If using a 9-pin serial port, use a
straight-through, 9-pin female-to-male cable. If the
only available serial port uses a 25-pin connector, a
standard 25-pin to 9-pin adapter is required. The
EV kit software checks the modem status lines
(CTS, DSR, and DCD) to confirm that the correct
port has been selected.
8) Start the MAX1416 program by opening its icon in the
Start | Programs menu.
9) Turn on the power supplies and slide SW1 to the ON
position. Select the correct serial port and press the
OK button. The program will automatically download
KIT1416.C16 to the module.
10) When the main window appears (Figure 1), click
Initialize and then Calibrate.
11) Apply input signals between AIN1+ and AIN1-. Tie
the unused analog input (AIN2+ and AIN2-) to GND.
Click Read or check Auto Read. Observe the code
and voltage readout on the screen.
Detailed Description
of Software
The main window of the evaluation software controls the
features of the MAX1416. The Measurement tab is used
to initialize, calibrate, and read data. Prior to reading the
MAX1416, select the appropriate MCLK master-clock
input source and click Initialize. The FS1 and FS0 bits in
the clock register determine the data rate.
The Initialize button writes the clock register INT,
CLKDIS, CLKDIV, CLK, and FS bits, and then writes to
the setup register with FSYNC = 1. The exact value
written to the clock register depends on the MCLK
input setting, and can be viewed by bringing up the
Clock tab after initialization.
The Calibrate button first writes the setup register with
FSYNC = 1, then writes setup with MD = 01 (self-cali-
bration mode) and FSYNC = 0. After DRDY returns low,
the MAX1416 setup register automatically returns to
MD = 00 and FSYNC = 0.
The Setup,Clock,Offset, and Gain tabs provide
read/write access to each of the registers. See
Figures 2–5.
The Comms and Data (Figure 6) tab provides access
to the Standby bit. The comms registers RS2, RS1,
RS0, and R/W bits are automatically set by each regis-
ter’s read and write buttons. The channel select bits
CH1 and CH0 are determined by which channel is
selected on the Measurement tab.
Sampling
To collect data, go to the Measurement tab and click
Sample. Select the sample size and click Begin
Sampling. After the samples have been collected, the
data is automatically uploaded to the host and is
graphed. Once displayed, the data can be saved to a
file (optional).
Saving Graphs to Disk
Data in the real-time graph and in the sampled data
graphs can be saved to a file (Figures 7–8). Only the
raw output codes are saved, but voltages can be
inferred based on the reference voltage and the maxi-
mum code value.
Evaluating Power-Down Mode
To enter standby mode, first make sure that Auto Read
is not checked in the Measurement tab sheet. Then go
to the Comms and Data tab and check Power Down,
then click Write.
Evaluate: MAX1416/MAX1415/MX7705
MAX1416 Evaluation Kit/Evaluation System
_______________________________________________________________________________________ 3