DIGITAL I/O MODULES DIN-RAIL MOUNTABLE OUTPUT MODULES FEATURES: CE Compliant DIN-Rail Mountable Single Point Output Modules (35mm DIN) UL Recognized/Horse Power Rated (E46203)/ CSA certified (38595) AC Output Rating 5 Amp at 12 to 280 VAC, with 250 Amp Single Cycle Surge Capability DC Output Rating 3 Amp at 3 to 60 VDC 3 to 32 VDC Input for AC Module, 5V or 24V for DC Module Zero Voltage Turn-on for AC Module 4 kV Optical Isolation with LED Indicator Barrier Strips Accept 14 to 28 AWG Wire Configured for Panel Mounting DIN RAIL AC OUTPUT MODULE 2.46 (62) 0.69 (17.5) 1 VAC VAC LOAD* (A) SCREW TERMINALS 2 REPLACEABLE 5A FUSE 3 LED S N U B LOAD* (B) ZERO VOLTAGE CIRCUIT +VCC LOGIC SUPPLY 0.16 (4) 4 INPUT 2.36 (60) 1.96 (50) 0.56 (14) *LOAD MAY BE WIRED IN LOCATION A OR B DIN RAIL DC OUTPUT MODULE 1 CASE COLORS: AC-BLACK DC-RED 1.77 (45) +VDC -VDC LOAD* (A) VAC SCREW TERMINALS 2 REPLACEABLE 5A FUSE 3 LED VAC +VCC LOGIC LOAD* (B) Rc AMPLIFIER +VCC LOGIC SUPPLY 0.125 (3) 4 INPUT 2.77 (70) DIMENSIONS: INCHES (MILLIMETERS) TOLERANCE: 0.020 (0.50) *LOAD MAY BE WIRED IN LOCATION A OR B. DC INDUCTIVE LOADS MUST BE DIODE SUPRESSED TO PREVENT DAMAGE TO THE I/O MODULE. (EQUIVALENT CIRCUIT DIAGRAMS) Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 2-30 DIGITAL I/O MODULES DIN-RAIL OUTPUT MODULES INPUT SPECIFICATIONS: (1) Model Number Parameter Nominal Voltage Minimum Voltage Maximum Voltage Drop-Out Voltage Maximum Current (2) Resistance (3) DROAC DRODC5 DRODC24 5-24 3.7 32 1.0 18.0 -- 5.0 3.5 8.0 1.0 18.0 250 24.0 18.0 32.0 1.0 13.0 2000 Units VDC VDC VDC VDC mA Ohms 2 OUTPUT SPECIFICATIONS: (1) Model Number Parameter Nominal Line Voltage Minimim Line Voltage Maximum Line Voltage Max Off-State Voltage (4) Max Off-State Leakage (5) Static Off-State dv/dt (6) Maximum Rated On-State Current (7) Min On-State Current Max Surge Current (8) On-State Voltage Drop (9) Horse Power Rating (13) DROAC DRODC5 DRODC24 120/240 VAC 12 VAC 280 VAC 600 Vpeak .1 mArms 200 V / sec 5-48 V 3.0 V 60 V 60 V 10 A N/A 5.0 Arms 50 mArms 250 Apeak 1.6 V 1/2 H.P. 3.0 A 10 mA 5.0 A 1.5 V N/A GENERAL SPECIFICATIONS: (1) Model Number DROAC DRODC5 DRODC24 Parameter Operating Temperature Range Storage Temperature Range Maximum Turn-on Time (10) Maximum Turn-off Time (10) Input/Output Isolation Voltage (11) Input/Output Capacitance (typical) Line Frequency Range Fuse (12) -30 to 80 -40 to 100 8.33 8.33 4000 8 47 to 63 5 -30 to 80 -40 to 100 0.1 0.75 4000 8 DC 5 Notes: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) Units C C mSec mSec VAC pF Hertz Amps Specifications apply to an ambient temperature of -30 to 80C unless otherwise noted. At nominal input voltage for DC modules, AC modules are current limited +/-10% at 25C . +/-10% at 25C for DC modules. Maximum 1 minute duration for OAC modules when applied as a DC voltage rather than peak AC voltage. At maximum line voltage, 25C for OAC modules, and 80C for ODC modules. Minimum dv/dt per EIA/NARM RS443, method RS397. dv/dt ratings do not apply to ODC modules. At 40C, derate OAC modules by 125 mA/C to 80C; derate ODC modules by 50 mA/C to 80C. At 25C. Maximum duration: 1 AC cycle for OAC modules, 1 second for ODC modules. At maximum rated on-state current and 25C. At maximum line voltage, maximum rated output current, nominal input voltage, 25C. Switching speed of OAC modules based upon 60 Hz line frequency. At 25C for 1 second maximum duration. Fuse is Buss, PC-TRON #PCE5. 1/2 H.P. at 240 VAC, 1/4 H.P. at 120 VAC. Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 2-31