MAFL-011026 MoCA Triplex Filter 5-85 / 105-1002 / 1125-1675 MHz Rev. V6 Functional Schematic Features 75 Ohm SMT unit RoHS* Compliant Description The MAFL-011026 is a low profile, surface mount filter with 3 transmission paths allowing full triplexer operation. The CATV reverse and forward bands are provided along with a further band meeting the MoCA specification. This filter is specifically designed for CATV and MoCA applications. Pin Configuration Ordering Information Part Number Package Pin Number Function MAFL-011026 200 piece reel 1 MoCA Port MAFL-011026-Tray 480 piece tray 4 Forward Port 7 Reverse Port 14 Common Port 2, 3, 5, 6, 8-13, 15-20 Ground * Restrictions on Hazardous Substances, European Union Directive 2011/65/EU. 1 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAFL-011026 MoCA Triplex Filter 5-85 / 105-1002 / 1125-1675 MHz Rev. V6 Electrical Specifications: TA = +25C, Z0 = 75 Reverse Path Insertion Loss 5 - 85 MHz dB -- 1.2 1.5 Reverse Path Rejection 105 - 126 MHz 126 - 1002 MHz 1125 - 1675 MHz 1675 - 3000 MHz dB 62 64 60 30 70 70 64 50 -- Forward Path Insertion Loss 105 - 126 MHz 126 - 860 MHz 860 - 1002 MHz dB -- 1.50 0.75 2.5 2.00 1.50 2.75 Forward Path Rejection 5 - 85 MHz 1125 - 1675 MHz 1675 - 3000 MHz dB 50 43 20 52 45 30 -- MoCA Path Insertion Loss 1125 - 1150 MHz 1150 - 1650 MHz 1650 - 1675 MHz dB -- 2.8 2.5 2.5 3.0 2.7 3.0 MoCA Path Rejection 5 - 85 MHz 85 - 1002 MHz 2300 - 3000 MHz dB 49 49 25 70 55 35 -- Input Return Loss 5 - 85 MHz 105 - 860MHz 860 - 1002MHz 1125 - 1675 MHz dB 16 16 12 12 18 18 16 16 -- Isolation - Forward to Reverse 5 - 38 MHz 38 - 85 MHz 105 - 1002 MHz dB 55 43 60 58 45 65 -- Isolation - Forward to MoCA 5 - 85 MHz 105 - 126 MHz 126 - 1002 MHz 1125 - 1675 MHz dB 49 49 49 43 70 70 53 45 -- Recommended Maximum Ratings RF Power 250 mW DC Current 30 mA Operating temperature -40C to +85C Storage temperature -40C to +85C 2 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAFL-011026 MoCA Triplex Filter 5-85 / 105-1002 / 1125-1675 MHz Rev. V6 PCB Layout Dimensions are in millimetres. Tolerance: .x 0.1mm Parts List PCB Stack-Up C1 Do Not Insert 0402 C2 Do Not Insert 0402 C3 2.7pF +/- 0.25pF 0402 C4 1.3pF +/- 0.1pF 0402 C5 0.6pF +/- 0.1pF 0402 C6 2.0pF +/- 0.1pF 0402 C7 7.5pF +/- 0.25pF 0402 Notes: C8 3.9pF +/- 0.25pF 0402 L1 82nH +/- 2% 0603 L2 5.6nH +/- 2% 0603 L3 6.8nH +/- 2% 0603 L4 12nH +/- 2% 0603 L5 22nH +/- 2% 0603 Gap dimension = 1.3mm Track dimension = 1.15mm Substrate is 1.6mm thick FR4 It is not recommended to run tracks under the filter A ground is required on the top layer of the application PCB RF shield should be kept a minimum of 10mm above the filter Any deviation from recommended footprint may compromise the filter performance For optimal filter performance the 4 transmission lines need to be at 75 impedance 3 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAFL-011026 MoCA Triplex Filter 5-85 / 105-1002 / 1125-1675 MHz Rev. V6 Application Schematic Triplex Filter DNI DNI Outline Dimensions Dimensions are in millimetres. Tolerance: .x 0.1 mm, except where specified. 4 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAFL-011026 MoCA Triplex Filter 5-85 / 105-1002 / 1125-1675 MHz Rev. V6 Typical Performance Curves Reverse Insertion Loss Forward Insertion Loss MoCA Insertion Loss Common Port Return Loss 5 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAFL-011026 MoCA Triplex Filter 5-85 / 105-1002 / 1125-1675 MHz Rev. V6 Typical Performance Curves Reverse Path Forward Path MoCA Path Reverse to Forward Isolation Forward to MoCA Isolation 6 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAFL-011026 MoCA Triplex Filter 5-85 / 105-1002 / 1125-1675 MHz Rev. V6 Tape & Reel Information Parameter Units Value Qty per reel - 200 Reel Size mm 330 Tape Width mm 72.0 Pitch mm 28.0 Ao mm 23.3 Bo mm 47.8 Ko mm 6.8 Orientation - F54 Reference Application Note ANI-019 for orientation Dimensions are in millimetres. 7 Tolerance: .x 0.1 mm, except where specified. M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAFL-011026 MoCA Triplex Filter 5-85 / 105-1002 / 1125-1675 MHz Rev. V6 Tray Information Parameter Units Value Min Order Qty - 480 Tray Length mm 270 Tray Width mm 200 Height mm 20.8 Ao mm 35 Bo mm 50 Ko mm 14.4 Orientation - See below Consecutive trays will be stacked alternately at 180 Dimensions are in millimetres. 8 Tolerance: .x 0.1 mm, except where specified. M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAFL-011026 MoCA Triplex Filter 5-85 / 105-1002 / 1125-1675 MHz Rev. V6 M/A-COM Technology Solutions Inc. All rights reserved. Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM") products. These materials are provided by MACOM as a service to its customers and may be used for informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM assumes no responsibility for errors or omissions in these materials. MACOM may make changes to specifications and product descriptions at any time, without notice. MACOM makes no commitment to update the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise, to any intellectual property rights is granted by this document. THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS, WHICH MAY RESULT FROM THE USE OF THESE MATERIALS. MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM customers using or selling MACOM products for use in such applications do so at their own risk and agree to fully indemnify MACOM for any damages resulting from such improper use or sale. 9 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support