For small diameter tubes Optical Bubble Sensor BE-A SERIES Fits perfectly with applicable tube sizes! Detects liquid and air bubbles without fail! Tube outer diameter o2 mm o0.078 in Tube outer diameter o3 mm o0.125 in Tube outer diameter o4 mm o0.156 in 2019.05 industrial.panasonic.com/ac/e/ Experience its ease of use! Optical bubble sensor is handy, simple, and precise! New proposals for ease of use One-touch attachment o2 mm o0.078 in tube type Simply attach the sensor with your hand! Hassle-free one-touch attachment without using tools! In the case of BE-A201(P) / BE-A301(P) In the case of BE-A401(P) o4 tube Push down Pull Pull Insert Tube Push down the tube into the sensor. *Tube: Equivalent to PFA New proposals for ease of use Stretch the tube and insert it into the sensor. *o4 tube: Equivalent to flexible PVC For small diameter tubes For o2 mm, o3 mm, o4 mm tubes Perfect fit into applicable tubes without obstructing flow rate. Compatible with tubes in inch size o2 mm tube type BE-A201(P) New proposals for ease of use o3 mm tube type BE-A301(P) High speed response time o4 mm tube type : BE-A201 (NPN output type) BE-A201P (PNP output type) Applicable tube : Transparent resin tube (Equivalent to PFA) Outer diameter : o2 mm 0.2 mm o0.078 in 0.008 in Inner diameter : o1 mm 0.2 mm o0.039 in 0.008 in Output operation: Liquid-absent-ON / Liquid-present-ON (equipped with two outputs) BE-A401(P) New proposals for ease of use Model No. Ultra compact New proposals for ease of use For a wide-range of power supply voltages High speed detection Fingertip size 5 to 24 V DC compliant 0.8 mm 0.032 in air gaps are reliably detected by optical technology at a response time of 20 s*. Ideal for traceability of the analysis process. Allows for installation in a narrow space. Allows for direct power supply from PC board. 0.8 mm 0.032 in New proposals for ease of use Built-in Amplifier No requirement of sensitivity adjustment Can be used immediately after installation by built-in amplifier. Equipped with two outputs, Liquid-absent-ON and Liquid-present-ON. *Refer to the specifications for detection conditions, BE-A201(P) has a response time of 30 s. 2 Allows for close proximity attachment Staggered pattern Parallel pattern (10 mm 0.394 in pitch) (15.5 mm 0.610 in pitch) o3 mm o0.125 in o4 mm o0.156 in tube type Model No. : tube type BE-A301 (NPN output type) BE-A301P (PNP output type) Model No. Applicable tube : Transparent resin tube (Equivalent to PFA) Outer diameter: o3 mm 0.2 mm o1/8 in 0.008 in Inner diameter: o2 mm 0.2 mm o1/16 in 0.008 in Output operation: Liquid-absent-ON / Liquid-present-ON (equipped with two outputs) : BE-A401 (NPN output type) BE-A401P (PNP output type) Applicable tube : Transparent resin tube (equivalent to flexible PVC) Outer diameter: o4 mm 0.15 mm o5/32 in 0.006 in Inner diameter: o2.4 mm 0.1 mm o3/32 in 0.004 in Output operation: Liquid-absent-ON / Liquid-present-ON (equipped with two outputs) Applications Liquid dispensing instrument Clinical laboratory instrument BE-A series Empty detection inside the tank BE-A series Air bubble detection after pumping BE-A series Air bubble detection before liquid dispensing Precise liquid dispensing Reagent/ cleaning fluid tank To dispensing nozzle 3 BE-A SERIES Type NPN output PNP output Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F. 2) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Refer to the figure 1 and 2. 3) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. 4) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. 5) Actual response time may differ from specification (typical example using applicable tube) due to dimension, light transmission or surface state of test tube in use. 6) Liquid being detected should also be kept within the rated ambient temperature range. 7) Confirm that the power supply voltage at the end of cable is more than 4.5 V when using an extension of over 20 m 65.167 ft. Bubble o2.5 mm o0.098 in cable 1 m 3.280 ft long 4-core x 0.09 mm 2 (AWG28) insulator diameter: o0.66 mm o0.026 in 2019.05 industrial.panasonic.com/ac/e/ (c)Panasonic Coporation 2019 Droplet fig.2 8.3 0.327 Operation indicator (Orange) 15.5 0.610 7 0.276 Beam axis o2.5 mm o0.098 in cable 1 m 3.280 ft long 4-core x 0.09 mm 2 (AWG28) insulator diameter: o0.66 mm o0.026 in Right side dimension (in common) Tube holder 9 0.354 2 x o3.5 o0.138 mounting holes 20 0.787 Beam axis If you have any question about Optical Bubble Sensor, please contact us by E-mail . No.PCE-BEA-1 May, 2019 14.7 0.579 8.3 0.327 9 0.354 7 0.276 Tube holder 3.5 0.138 15.5 0.610 2 0.079 o2.5 mm o0.098 in cable 1 m 3.280 ft long 4-core x 0.09 mm 2 (AWG28) insulator diameter: o0.66 mm o0.026 in 20 0.787 Beam axis Operation indicator (Orange) 2 x o3.5 o0.138 mounting holes 2 0.079 9 0.354 7 0.276 Bubble fig.1 BE-A401(P) 14.2 0.559 8.3 0.327 2 x o3.5 o0.138 mounting holes Tube holder 3.5 0.138 15.5 0.610 Air The CAD data can be downloaded from our website. BE-A301(P) Operation indicator (Orange) Liquid Air gap Liquid DIMENSIONS (Unit: mm in) BE-A201(P) Tube 16.5 0.650 2.5 0.098 10 0.394 Vibration resistance Shock resistance Emitter element Material Cable Cable extension (Note 7) Clamping torque Weight EMC Directive, RoHS Directive 0.8 mm 0.032 in or more Liquid (Note 3) o2 mm 0.2 mm o0.078 in 0.008 in o3 mm 0.2 mm o1/8 in 0.008 in o4 mm 0.15 mm o5/32 in 0.006 in o1 mm 0.2 mm o0.039 in 0.008 in o2 mm 0.2 mm o1/16 in 0.008 in o2.4 mm 0.1 mm o3/32 in 0.004 in Transparent resin tube (equivalent to flexible PVC) Transparent resin tube (equivalent to PFA) 5 to 24 V DC 10 % Ripple P-P 10 % or less 15 mA or less NPN open-collector transistor PNP open-collector transistor *Maximum sink current: 50 mA *Maximum source current: 50 mA *Applied voltage: 30 V DC or less (between output and 0 V) *Applied voltage: 30 V DC or less (between output and + V) *Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) *Residual voltage: 2 V or less (source current at 50 mA) 1 V or less (source current at 16 mA) Switchable either Liquid-absent-ON or Liquid-present-ON Incorporated 30 s or less 20 s or less 80 s or less Orange LED (lights up with absent liquid) Power supply reverse polarity protection , Output reverse polarity protection IP40 (IEC) -25 to +55 C -13 to +131 F (No dew condensation or icing allowed), Storage: -30 to +80 C -22 to +176 F 35 to 85 % RH, Storage: 35 to 85 % RH Fluorescent light: 1,000 x at the light-receiving face 1,000 V AC for between one min. between all supply terminals connected together and enclosure 20 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each 100 m/s2 acceleration in X, Y, and Z directions three times each Infrared LED(Peak emission wavelength: 855 nm 0.034 mil, non-modulated) Enclosure: PBT, Tube holder: Polyamide, Indicator: Polycarbonate 0.09 mm2 4-core cabtyre cable 1 m 3.280 ft Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. 0.5N*m or less Net weight: 15 g approx., Gross weight: 25 g approx. 14.8 0.583 Environmental resistance Output operation Short-circuit protection Response time When detecting bubble (Note 5) When detecting liquid Operation indicator Protection circuits Protection Ambient temperature (Note 6) Ambient humidity Ambient illuminance Voltage withstandability Insulation resistance for o4 mm o0.156 in tube BE-A401 BE-A401P 20 0.787 Output (Incorporated with 2 outputs) for o3 mm o0.125 in tube BE-A301 BE-A301P 2 0.079 Regulatory compliance Detectable air gap (Note 2) Sensing object Applicable tube dia. Outer dia. (Note 4) Inner dia. Applicable tube type (Note 4) Supply voltage Current consumption for o2 mm o0.078 in tube BE-A201 BE-A201P 3.5 0.138 Item Model No. SPECIFICATIONS Operation indicator o5.2 (Orange) o0.205 3 0.118 USA customers : usa-bmpj@ml.jp.panasonic.com EURO customers : euro-bmpj@ml.jp.panasonic.com Panasonic Corporation Industrial Device Business Division 1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan Specifications are subject to change without notice.