189
G5LBG5LB
400-mW Models
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
600-mW Models
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
■Contact Ratings
Note: P level: λ60 = 0.1 x 10–6 operations
■Approved Standards
UL325, UL873 (File No. E41643 Vol. 11 Sec. 6) and CSA C22.2 No. 14 (File No. LR31928)
EN61810-1 (2nd Ed) and EN60255-25 (VDE Reg. No. A662)
■Characteristics
∗ G5LB-1
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 36 VDC 48 VDC
Rated current 136.4 mA 80.0 mA 67.8 mA 45.7 mA 32.8 mA 17.0 mA 11.3 mA 8.5 mA
Coil resistance 22.0 Ω62.5 Ω88.5 Ω196.9 Ω366.0 Ω1,407.7 Ω3,196.8 Ω5,638.0 Ω
Must operate voltage 75% of rated voltage (max.)
Must release voltage 10% of rated voltage (min.)
Max. voltage 130% of rated voltage at 85°C, 170% of rated voltage at 23°C
Power consumption Approx. 400 mW
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 36 VDC 48 VDC
Rated current 200.2 mA 120.0 mA 100.7 mA 66.8 mA 50.4mA 25.3 mA 16.6 mA 12.6 mA
Coil resistance 15.0 Ω41.7 Ω59.6 Ω134.8 Ω237.9 Ω947.6 Ω2,164.8 Ω3,800.0 Ω
Must operate voltage 75% of rated voltage (max.)
Must release voltage 10% of rated voltage (min.)
Max. voltage 130% of rated voltage at 85°C, 170% of rated voltage at 23°C
Power consumption Approx. 600 mW
Load Resistive load (cos φ=1)
Rated load 10 A at 120 VAC, 8 A at 30 VDC, 10 A at 250 VAC
Rated carry current 10 A
Max. switching voltage 250 VAC, 125 VDC (30 VDC when UL/CSA standard is applied)
Max. switching current AC: 10 A, DC: 8 A
Max. switching power 1,200 VA, 240 W, 2,500 VA
Failure rate (reference value) 100 mA at 5 VDC
Model Coil rating Contact rating
G5LB 3 to 48 VDC 10 A, 250 VAC (general use, 100,000 cycles)
10 A, 30 VDC (resistive load, 100,000 cycles)
Model Coil rating Contact rating
G5LB 3, 5, 6, 9, 12, 24, 36, and 48 VDC 10 A 30 VDC (resistive load, 50,000 cycles)
NO and Sealed: 10 A 250 VAC (general use, 25,000 cycles at 85°C)
NO and Vent Hole: 10 A 250 VAC (general use, 50,000 cycles at 85°C)
NC and Vent Hole: 10 A 250 VAC (general use, 25,000 cycles at 85°C)
Contact resistance 100 mΩ max.
Operate time 10 ms max.
Release time 5 ms max.
Max. switching frequency Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 750 VAC, 50/60 Hz for 1 min. between contacts of same polarity
2,000 VAC, 50/60 Hz for 1 min. between coil and contacts
Impulse withstand voltage 4,500 V between coil and contacts, 1.2 × 50 µs
Vibration resistance Destruction: 10 to 55 to 10 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 to 10 Hz, 1.5-mm double amplitude
Shock resistance Destruction: 1,000 m/s2 (approx. 100 G)
Malfunction: 100 m/s2 (approx. 10 G)
Endurance Mechanical: 10,000,000 operations min. (at 18,000 operations/hr)
Electrical: ∗100,000 operations min. (at 1,800 operations/hr, 10 A, 120 VAC)
Ambient temperature Operating: −40°C to 85°C
Ambient humidity Operating: 35% to 85%
Weight Approx.: 10 g