1.5A 3-Terminal Adjustable Voltage Regulator
10
While the SG117 is stable with no output capacitor, for improved AC transient response and to prevent the
possibility of oscillation due to an unknown reactive load, a 1μF capacitor is also recommended at the output.
Because of their low impedance at high frequencies, the best type of capacitor to use is solid tantalum; ceramic
capacitors may also be used. When bypass capacitors are used, it may be necessary to provide external protection
diodes to prevent this external large capacitance from discharging through internal low current paths, which may
damage the device. Although the duration of any surge current is short, there may be sufficient energy to damage
the regulator. This is particularly true of the large capacitance on the ADJ pin when output voltages are higher than
25V. Such a capacitor could discharge into the ADJ pin when either the input or output is shorted. See figure below.
Figure 20 · Use of Protection Diodes
Load Regulation
Because the SG117A is a three-terminal device, it is not possible to provide true remote load sensing. Load
regulation will be limited by the resistance of the wire connecting the regulator to the load. From the data sheet
specification, regulation is measured at the bottom of the package. Negative side sensing is a true Kelvin connection,
with the bottom of the output divider returned to the negative side of the load. Although it may not be immediately
obvious, best load regulation is obtained when the top of the divider is connected directly to the case, not to the load.
This is illustrated in (Connections for Best Load Regulation). If R1 were connected to the load, the effective
resistance between the regulator and the load would be:
Resistance Line ParasiticR,
R
RR
RP
1
12
P
Connected as shown, RP is not multiplied by the divider ratio. RP is about 0.004Ω per foot using 16 gauge wire.
This translates to 4mV/ft. at 1A load current, so it is important to keep the positive lead between regulator and load as
short as possible.
Figure 21 · Connections for Best Load Regulation
SG117A OUT
ADJ
IN VOUT
R1
R2
D2
1N4002
C1
1 µF
D1 1N4002
C2
10µF
Note: D1 protects against C1
D2 protects against C2